• 제목/요약/키워드: Impulse Current

검색결과 370건 처리시간 0.027초

고속열차의 선두부 형상이 터널 입구압력파에 미치는 영향 (Effect of Train Nose Shape on the High-Speed railway Tunnel Entry Compression Wave)

  • 김희동;김태호;서태원
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 1998년도 창립기념 춘계학술대회 논문집
    • /
    • pp.596-603
    • /
    • 1998
  • The entry compression wave, which is generated at the entrance of the tunnel, is almost always associated with the pressure transients in the tunnel as well as the impulse noise at the exit of the tunnel. It is highly required to design the train nose shape that can minimize such undesirable phenomena. The objective of the current work is to investigate the effects of the train nose shape on the entry compression wave. Numerical computations were applied to one-dimensional unsteady compressible flow in high-speed railway train/tunnel systems. A various shape of train noses were tested for a wide range of train speeds. The results showed that the strength of the entry compression wave is not influenced by the train nose shape, but the time variation of pressure in the entry compression wavefront is strongly related to the train nose shape. The current method of the characteristics was able to represent a desirable nose shape for various train speeds. Optimum nose shape was found to considerably reduce the maximum pressure gradient of the entry compression wave.

  • PDF

디지털시대의 대형사고의 전기적 영향 고찰 (Electric power system effect investigation of large size digital signal accident thought in digital age)

  • 강태근
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2004년도 춘계학술대회 논문집
    • /
    • pp.575-580
    • /
    • 2004
  • The latest equipment automatic Intelligence of digital base done large size equipment appear in succession. That run by voltage electric current(mA, mV, ${\mu}A,\;{\mu}V$) that outline is microscopic of action of accuracy large size equipment of this digital base is bulk. Have received influence that is great in river electric field by installment that use computer. Most of domestic working voltage from service entrance extra-high voltage and working voltage of commercial frequency 60Hz working voltage 220V that use our country outside 1 country in interior of 22.900V for semiconductor use computer use digital installment of appliance as well as various smalls of digital base, middle, large size that safety is these fine voltage electric current that is not enough direct admonition hundred vast damage give can. Also, already act in surge circle and impulse transient phenomena such as several thousands, myriads, strong bit error more than billions time to digital fine electronic circuit by mistake use of using electric facility system of system electric power.

  • PDF

Microprocessor를 이용한 AC Current, AC Voltage의 계측 알고리즘에 관한 연구 (On the study of measurement algorithm using Microprocessor for AC Current and AC Voltage)

  • 서용원;연준상;양오
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 하계학술대회 논문집 D
    • /
    • pp.2106-2108
    • /
    • 2003
  • 단상 또는 3상의 AC 전원의 전류나 전압 또는 전력을 계측하기 위해 Analog Signal들을 Digital Signal로 변환하여 특정 Algorithm의 연산을 수행하여 결과를 얻는 과정을 Microprocessor를 이용하여 처리하는 방법은 산업현장이나 연구개발에서 흔히 사용하는 방법이다. 본 논문에서는 Microprocessor를 이용하여 보편화된 3가지의 계측 Algorithm인 DFT, True RMS, Summation Algorithm을 사용하여 동일 System에 3상 AC의 전류 부하를 일정 범위에서 가변 하여 인가시키면서 계측 값을 사용하여 Algorithm의 계측 결과의 오차율과 연산에 소요되는 시간과 외부 잡음인 Surge, Impulse, 정전기, 방파, 고조파에 대한 System의 처리 효율을 연구 하였다.

  • PDF

퓨즈가 내장된 엘보접속재의 설계 (Design of Fuse Mounted Elbow Connector)

  • 최경선;이철호;송일근;권태종;권영복;한명관
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2000년도 추계학술대회 논문집
    • /
    • pp.383-386
    • /
    • 2000
  • Fuse mounted elbow connector used for pad mounted transformer was designed and investigated. Requirements of electrical ratings such as partial discharge, ac withstand voltage and impulse voltage and material properties were proposed in accordance with IEEE 386 and pre-standard (PS) 147-219∼229 of KEPCO. The connector can be jointed with pad mounted transformer and current limiting fuse which is installed inside of the connector easily replaced with new one in the case of breakdown of the fuse. Electric field analysis was also introduced in other to verify the reliability of the design.

  • PDF

철근콘크리트 도상에서 AF 궤도회로 신호전류 저감방지대책에 관한 연구 (A Study on the Method of preventing from Reduction of AF Track Circuit Signal Current on a Ferroconcrete Roadbed)

  • 홍효식;유광균;노성찬
    • 한국철도학회논문집
    • /
    • 제13권5호
    • /
    • pp.500-503
    • /
    • 2010
  • 지금까지 궤도회로는 레일을 전기회로의 일부로 사용하여 열차의 위치 검지용으로만 사용하였으나 철도차량이 고속화 되면서, 지상신호의 한계를 극복하기 위하여 차상신호시스템의 사용이 일반화 되어가고 있다. 궤도회로의 전원은 직류나 고전압 임펄스를 사용하던 방식에서 가청주파수를 사용하는 고주파 교류궤도회로의 사용이 일반화 되고 있다. 철도도상도 환경과 궤도의 유지보수성 개선을 위하여 철근콘크리트 도상의 사용이 증대되고 있다. 철근 콘크리트 도상에서 고주파 교류궤도회로를 사용할 경우 도상의 내구성 향상을 위하여 사용되는 수많은 격자모양의 철근들로 인하여 전기적 절연에 의한 누설전류가 아닌 자기결합에 의한 손실로 인한 궤도정수의 변화를 초래할 수 있다. 본 논문은 철근콘크리트도상에서 AF(Audio Frequency)궤도회로를 사용하였을 경우 도상 철근에 의한 궤도회로신호의 영향과 손실을 시뮬레이션을 통하여 알아보고 이를 방지할 수 있는 방안을 제시하였다.

스플라인 기어부 결함의 와전류검사 신호처리에 관한 연구 (Study on Signal Processing in Eddy Current Testing for Defects in Spline Gear)

  • 이재호;박태성;박익근
    • 비파괴검사학회지
    • /
    • 제36권3호
    • /
    • pp.195-201
    • /
    • 2016
  • 금속성부품의 자동화 생산라인 상에서 결함검사는 통상 시스템 가격이 합리적이고 고속검사가 가능한 와전류검사(ECT, eddy current testing) 기법이 많이 사용된다. 이러한 금속성 피검사체 가운데 특별히 스플라인 샤프트(spline shaft)의 스플라인 기어부(spline gear)와 같이 표면이 고르지 못한 피검사 대상에 대하여 ECT검사를 적용할 경우 주파수 분포도가 유사하면서 동시에 상대적으로 큰 표면신호로 인해 센서로부터 획득한 원신호와 결함에 의해 발생한 신호를 분리해내기가 어렵다. 이러한 스플라인 기어부의 결함신호 검출을 용이하게 하기 위해서는 주변 잡음신호에서 결함신호만을 구분해낼 수 있는 고차필터의 구현이 필수적이고 동시에 각 생산라인과 피검사체의 상황에 따라 필터의 통과대역을 조절할 수 있어야 한다. 이러한 통과대역 조절이 가능한 고차필터 구현을 위해 디지털 방식 중 하나인 IIR (infinite impulse filter) 필터에 의한 구현방안을 검토하고, 신호검출을 위해 시스템 레벨에서 설계요소들의 최적화를 통해 결함신호검출을 시도하였다.

중첩전압(직류+교류 60Hz)에서 산화아연 피뢰기 소자의 누설전류 특성 (The characteristic of leakage current in ZnO surge arrestor elements with mixed direct and 60Hz voltage)

  • 이복희;박건영;강성만;최휘성;오성균
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 추계학술대회 논문집 전기물성,응용부문
    • /
    • pp.186-188
    • /
    • 2003
  • The ZnO surge arrester is the protective device for limiting surge voltages on equipment by diverting surge current and returning the device to its original status. The occurrence of overvoltage appears in any phase to AC power supply system and it appears in mixing AC and impulse voltages, moreover because HVDC power supply system uses converter in semiconductor, it makes mixed DC and high harmonics voltages. In this study, the various mixed AC and DC voltages was made for investigating the degradation effect of ZnO arrester according to mixed voltage. As a result, the increase of DC component to mixed voltages causes the increase of resistive component of total leakage current to ZnO block. In changing V-I curve for mixed voltages, the cross-over point acts a factor as making the proper capacitor size of an equivalent circuit for ZnO block.

  • PDF

계면활성제가 첨가된 염수용액에 따른 폴리머 애자의 트래킹 성능 평가 (Tracking Performance Test of Polymer Insulator with Salt Solution which is added Surface Active Agent)

  • 조한구;한동희;이운용;임기조;최인혁
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2004년도 하계학술대회 논문집 Vol.5 No.2
    • /
    • pp.1121-1124
    • /
    • 2004
  • Aging test to estimate life property of polymer insulator is executed through several international standard such as IEC 61109 and CEA tracking wheel test, but is not getting clear conclusion yet. There are two methods in the diagnosis method of polymer insulator such as off-line and on-line. The diagnosis methods in off-line are external condition analysis by the eye, contaminant analysis on surface, surface analysis, pollution withstand voltage test, power frequency flashover voltage test, lightning impulse flashover test, tensile fracture load test and flexural load test. The diagnosis methods in off-line most are the method for virgin and last aged sample. However, the diagnosis method in on-line is method that can be evaluate sample state as progressing continuously aging test in beginning, The diagnosis method in on-line is arranged as following: leakage current measurement, electric field, surface state investigation, thermal image, emitting light measurement and then so. In this paper, the tracking performance of polymer insulator with salt solution which is added surface active agent. The diagnosis of insulator sample has been analyzed by leakage current and visual examination.

  • PDF

극저온 헬륨가스의 절연파괴 및 연면방전 특성 (Electrical Breakdown and Flashover Characteristics of Gaseous Helium at Cryogenic Temperature)

  • 곽동순
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제14권3호
    • /
    • pp.38-42
    • /
    • 2012
  • Fixtures such as bushings in terminations of high temperature superconducting(HTS) power cable systems are subjected to high voltages, which have to transition from ambient to cryogenic temperatures. As such it is imperative to ensure the integrity of the dielectrics under all operating conditions, including thermal aspects brought about by the passage of current. Gaseous helium(GHe) at high pressure is regarded as a potential coolant for superconducting cables. The dielectric aspects of cryogenic helium gas are both complex and demanding. In this experimental study we looked at the interface between a smooth epoxy surface and high pressure helium gas in a homogeneous electric field. The alternating current(AC) flashover voltages of epoxy samples are presented. The results have been analyzed by using Weibull statistics. In addition to the behavior of the epoxy in gaseous helium as a function of pressure and temperature we also present data of the characteristics of the epoxy in mineral oil and in liquid nitrogen($LN_2$). The breakdown characteristics of a uniform field gap in gaseous helium as a function of pressure and temperature under AC, direct current(DC) and lightning impulse voltages are also given. Electric field calculations have been made for one of the experimental geometries in an attempt to explain some of the anomalies in the experimental results.

ZnO 나노분말로 제조한 Bi계 바리스터의 써지내량 특성 (Characteristics on the Surge Capability of Bi-based Varistor Fabricated with ZnO Nano-powder)

  • 왕민성;박춘배
    • 한국전기전자재료학회논문지
    • /
    • 제19권9호
    • /
    • pp.862-867
    • /
    • 2006
  • Bi-based nano-varistors and micro-varistors fabricated with each ZnO nano-powder and micro-powder were studied about characteristics on the surge capability in this study. ZnO nano-varistors were sintered in air at $1050^{\circ}C$ for 2 hr. The voltage-current and residual voltage properties of ZnO nano-varistor were compared with their of ZnO micrio-varistor. As a result of these properties, our ZnO nano-varistor has about 3 times at operating voltage as compared with conventional ZnO varistor fabricated with micro-powder and the residual voltage was 8.06 kV at nominal discharge current 101kA in the lighting impulse current test. And then the residual voltage rate 1.72 of our nano-varistor has had better performance than the 1.79 of micro-varistor because ZnO nano-varistor has shown much quick response property because of increasing effective cross-section area. Also, to analysis surge capability took thermal images for pyrexia temperature distribution with each of the varistors after operating varistors. Nano-varistor doesn't have shown local overheating and can confirm accurate temperature grade on the surface of its.