• 제목/요약/키워드: Impulse Current

Search Result 370, Processing Time 0.032 seconds

Characteristics of lightning impulse pre-breakdown discharge in $SF_6\;and\;SF_6/CO_2$ mixtures ($SF_6$$SF_6/CO_2$ 혼합기체 중에서의 뇌임펄스 전구방전의 특성)

  • Lee, Bok-Hee;Oh, Sung-Kyun;Baek, Young-Hwan
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2005.05a
    • /
    • pp.57-60
    • /
    • 2005
  • This paper describes the experimental results of the pre-breakdown phenomena in $SF_6/CO_2$ mixtures under non-uniform electric fields caused by positive and negative lightning negative voltages. $SF_6/CO_2$ mixtures have an advantage of an environmental aspect and cost reduction, and safety aspects. In order to analyze the pre-breakdown processes in $SF_6/CO_2$ mixtures stressed by impulse voltages, pre-breakdown current and luminous signals were measured by a shunt and a photo-multiplier tube, respectively. Dielectric strengthes of $SF_6/CO_2$ mixtures were investigated. Additionally, characteristics of discharge channels were observed by high speed cameras and the physical properties were discussed. The pre-breakdown propagates with a stepwise process. The in to breakdown from the corona onset point in positive polarity was shorter than that in negative polarity. The time intervals of positive leaders are shorter than those of negative leaders, and the path of positive leader channel is zigzag.

  • PDF

Statistical study of phase reversal locations on the SC-associated preliminary impulse

  • Sung, Suk-Kyung;Kim, Khan-Hyuk;Cho, Kyung-Suk
    • Bulletin of the Korean Space Science Society
    • /
    • 2008.10a
    • /
    • pp.30.3-30.3
    • /
    • 2008
  • In this study, we investigate the magnetic latitude of phase reversal on the sudden commencement (SC)-associated preliminary impulse with 267 SC events using the ground magnetometer data of the IMAGE from 1997 to 2005. During SC event, geomagnetic fields are affected by various currents flowing in the magnetosphere and/or ionosphere. In particular, high-latitude geomagnetic field variations are significantly dominated by the change of SC-associated field aligned current (FAC). Until now, however, there are few studies to examine where the location of the FAC in the ionosphere is and what determines the location of the FAC. The location of the SC-associated FAC can be examined by using magnetometer data obtained from high-latitude stations distributed along the same magnetic meridian. The phase reversal locations are concentrated two regions, ~62 deg (L~4.5) and ~70 deg (L~8.5) in magnetic latitude. If FAC is a result of a mode conversion from fast mode to Alfven mode, then the FAC location could be determine by the duration time of the input energy. When we use the rise time, dT, as the input energy, there is no relationship between dT and the location where the first pulse of SC is reversed. We consider other factors such as local time and solar wind condition.

  • PDF

The Analysis of Structural Relationships among Public Technology Transfer, Technological Performance, and R&D Productivity (공공기술 이전, 기술적 성과, 연구개발 생산성 간의 구조적 관계 분석)

  • Jeon, Jieun;Kwon, Sang Jib
    • Knowledge Management Research
    • /
    • v.19 no.2
    • /
    • pp.1-19
    • /
    • 2018
  • This study aims to identify the causal relationship among public technology transfer, technological performance, and research and development (R&D) productivity. Using the impulse-response function(IRF) of a panel vector autoregressive model (panel VAR), this study suggests the results of how long the factors such as technological performance (patent), public technology transfer, and R&D productivity takes and lasts if a one-unit shock of standard deviation occurs. As a result, first, the increase of public technology transfer activities has no power to increase the technology performance but improve the R&D productivity. If the public institute increases its technology transfer activities by one unit, the R&D productivity will increase within five years. Second, the impact of increasing technological performance on improvement of public technology transfer and R&D productivity is an insignificant. Third, the effect of R&D productivity on the public technology transfer creates a substantial reaction after a current time. Considering the structural relationships among public technology transfer, technological performance, and R&D productivity, if policy makers intend to construct the active R&D circumstance, technology suppliers should be motivated to run the active R&D mechanism because they achieve gains.

Electrochemical hydrothermal treatment on Pure Titanium by the method of Cathodic reduction (음극환원법에 의한 Pure Ti의 전기화학적 열수처리)

  • Song, Jae-Joo;Kim, Kyeong-Seon
    • Journal of Korean society of Dental Hygiene
    • /
    • v.7 no.4
    • /
    • pp.471-479
    • /
    • 2007
  • The purpose of this study was to examine the optimum condition of impulse during the anodic spark oxidation applying pulse current as well as to find the excellent condition for HA precipitation the after electrochemical hydrothermal treatment by cathode reduction method. After anodic spark oxidation, the anodized specimen and the Pt plate connected cathode and anode, respectively. Hydrothermal treatment performed at 90, 120, $150^{\circ}C$ for 2 hours in the electrolyte containing $K_2HPO_4$, $CaCl_2{\cdot}2H_2O$, Tris(Hydroxymethyl)-$(CH_2OH)_3\;CNH_2$(Aminomethane), and NaCl. The optimum impulse voltage for anodic spark oxidation was 350V. The optimum pulse cycle measured at 10 mS. The HA crystals precipitated excellently by cathode reduction at $150^{\circ}C$ for 2 hours. The phases of anatase, rutile, and HA coating on the surface of modified titanium surface immersed in Hanks' solution for 3weeks were detected by XRD measurement and the intensity of HA crystal phase has increased by temperature and time of hydrothermal treatment. According to the our experiments, we found that Pure Ti will be good materials of bioactivity and biocompatibility.

  • PDF

Numerical Study on High-Speed railway Tunnel Entrance Hood (고속철도 터널 입구후드에 관한 수치해석적 연구)

  • 김희동;김동현
    • Proceedings of the KSR Conference
    • /
    • 1998.05a
    • /
    • pp.604-611
    • /
    • 1998
  • High-speed railway trains entering and leaving tunnels generate finite amplitude pressure wave which propagate back and forth along the tunnels, reflecting at the open ends of the tunnels and at other discontinuities such as ventilation shafts and the train themselves. In present day railways, the magnitudes of the pressure waves are much too small to cause structual damage, but they are a serious potential source of aural discomport for passengers on unsealed trains. Almost always do the pressure waves propagating along the tunnels lead to a hazardous impulse noise near the exit portal of the tunnel. In order to alleviate such undesirable phenomena, some control strategies have been applied to the compression wave propagating inside the tunnel. The objective of the current work is to investigate the effect of tunnel entrance hoods on the entry compression wave at the vicinity of the tunnel entrance. Three types of entrance hoods were tested by the numerical method using the characteristics of method for a wide range of train speeds. The results show that the maximum pressure gradient of compression wave can be considerably reduced by the tunnel entrance hood. Desirable hood shape for reduction of the pressure transients and impulse noise was found to be of abrupt type hood with its cross-sectional area 2.5times the tunnel area.

  • PDF

Electrical Insulation Characteristics of HTS SMES (고온초전도 SMES의 절연특성)

  • Cheon Hyeon-Gweon;Choi Jae-Hyeong;Kwag Dong-Soon;Kim Hae-Jong;Seong Ki-Chul;Yun Mun-Soo;Kim Sang-Hyun
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.19 no.6
    • /
    • pp.574-578
    • /
    • 2006
  • Toward the practical applications, on operation of conduction-cooled HTS SMES at temperatures well below 77 K should be investigated, in order to take advantage of a greater critical current density of HTS and considerably reduce the size and weight of the system. Recently, research and development concerning application of the conduction-cooled HTS SMES that is easily movement are actively progressing in Korea. Electrical insulation under cryogenic temperature is a key and an important element in the application of this apparatus. Using multi wrapped copper by Polyimide film for HTS SMES, the breakdown characteristics of models for turn-to-turn, that is surface contact model, were investigated under ac and impulse voltage at 77 K. A material that is Polyimide film (Kapton) 0.025 mm thickness is used for multi wrapping of the electrode. Statistical analysis of the results using Weibull distribution to examine the wrapping number effects on breakdown voltage under at and impulse voltage in $LN_2$ was carried.

Characteristics of lightning impulse preliminary breakdown discharge under non-uniform electric field in $SF_6/CO_2$ mixtures (불평등전장에서 $SF_6/CO_2$ 혼합기체의 뇌임펄스 전구방전특성)

  • Lee, B.H.;Oh, S.K.;Baek, Y.H.;Ahn, C.H.;Jeon, D.K.
    • Proceedings of the KIEE Conference
    • /
    • 2005.07c
    • /
    • pp.2140-2142
    • /
    • 2005
  • This paper presents the experimental results on the preliminary breakdown characteristics under a highly non-uniform electric field in $SF_6/CO_2$ gas mixtures. The impulse preliminary breakdown developments are investigated by the measurements of corona current and light emission images. As a result, the preliminary breakdown development mechanisms for both positive and negative polarities are same. The first streamer corona is initiated at the tip of needle electrode, and the leaders develop with a stepwise propagation and bridge the test gap. The pause time of leader pulses in the positive polarity is significantly shorter than that in the negative polarity. Also, the time interval between the first streamer corona onset and breakdown in the negative polarity was much longer than that in the positive polarity The discharge channel paths in the positive polarity were zigzag. On the other hands, the leader channel in the negative polarity was thicker than that in the positive polarity.

  • PDF

DC and Impulse Insulation Characteristics of PPLP for HTS DC Cable (고온초전도 직류 케이블용 절연재료인 PPLP의 직류 및 임펄스 절연 특성)

  • Kim, Woo-Jin;Pang, Man-Sik;Kim, Hae-Jong;Cho, Jeon-Wook;Kim, Sang-Hyun
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.26 no.7
    • /
    • pp.545-549
    • /
    • 2013
  • To realize the high-Tc superconducting (HTS) DC cable system, it is important to study not only high current capacity and low loss of conductor but also optimum electrical insulation at cryogenic temperature. A model HTS DC cable system consists of a HTS conductor, semi-conductor, cooling system and insulating materials. Polypropylene laminated paper (PPLP) has been widely adopted as insulating material for HTS machines. However, the fundamental insulation characteristics of PPLP for the development of HTS DC cable have not been revealed satisfactorily until now. In this paper, we will discuss mainly on the breakdown characteristics of 3 sheets PPLP in liquid nitrogen ($LN_2$). The characteristics of the diameter, location of butt-gap, distance between butt-gap length, pressure effect, polarity effect under DC and impulse voltage were studied. Also, the DC polarity reversal breakdown voltage of mini-model cable was measured in $LN_2$ under 0.4 MPa.

Trend in the Developments of Liquid Rocket Engine In Russia and Ukraine (러시아와 우크라이나의 액체로켓엔진 개발 동향)

  • Kim, C.W.;Cho, W.K.;Park, S.Y.;Seol, W.S.
    • Current Industrial and Technological Trends in Aerospace
    • /
    • v.8 no.2
    • /
    • pp.86-97
    • /
    • 2010
  • This paper treats with the history and current trends in the developments of liquid-propellant rocket engine in Russia and Ukraine which are among world leaders in the technology of liquid rocket engine(LRE). In 1960s formerly the Soviet Union accepted the closed cycle engine for increasing the pressure in the combustion chamber and specific impulse to the maximum. However, since financially difficult times after 1990, they have decreased the cost for the development of new rocket engines. It was achieved by using existing units for new developed engines and minimizing the total number of engines and tests through the reasonable planning in the process for the experimental improvement of LRE. In addition, nowadays international cooperation in supplying LRE for commercial rocket and development of next generation LRE, such as 3 components engines and mathane engines, are proceeding.

  • PDF

A Study on Investigation Method of the Electric Fire Scene Caused by Lightning (낙뢰로 인한 전기화재의 현장조사기법 연구)

  • Song, Jae-Yong;Sa, Seung-Hun;Nam, Jung-Woo;Kim, Jin-Pyo;Park, Nam-Kyu
    • Fire Science and Engineering
    • /
    • v.25 no.1
    • /
    • pp.50-56
    • /
    • 2011
  • In recently years, occurrences of lightning return strokes have been increased by global worming effect and intensity of lightning impulse voltage and current accompanied by lightning discharges has being strengthening. In Korea, 560 thousand lightning discharges happened in 200S. According to the increasing frequencies of lightning, human deaths and damages to the structure have been increased steadily. Electric fire caused by lightning return strokes due to the breakdown between power line and ground line from the ground potential rise on a process of the lightning impulse current through to the ground. The damages of lightning were occurring at same time in the neighboring areas of the lightning point. In order to protect from the lightning stroke, we made a suggestion to use protection devices and equipotential bonding at the dangerous areas. The analysis results of electric fires caused by lightning would be utilized to investigate and to find accurate fire cause in the fire scenes.