• Title/Summary/Keyword: Improvement of energy performance

Search Result 1,087, Processing Time 0.035 seconds

Dynamic Design of Machine Tool Structure by Substructure Synthesis Method (부분구조 합성법을 이용한 공작기계 구조물의 동적설계)

  • 이원광
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.5 no.4
    • /
    • pp.82-89
    • /
    • 1996
  • In this study, to choose the drilling m/c with analysis model for dynamic design of machine tool strctures, are used substucture syntheis method for reduction to degrees of freedom of dynamic model and analysis evaluation of substructures The dynamic factors of substurctures are examined by substructure synthesis method. And that dynamic design of structures for energy balancing are performed. The computer program for calculated of the dynamic and energy distribution analysis was developed. Result of numerical analysis by developed program obtained to conclusion as following. The design of machine tool structures by dynamic avoid the resonances, and are known to considered based on the energy balancing. These methods can be used effectively for the performance evaluation, design modification and improvement of dynamic performance evaluation, design modification and improvement of dynamic performance of machine tools.

  • PDF

Analysis of Application Elements for improvement in the generated electric power performance of balcony BIPV System (발코니형 BIPV시스템의 발전성능 향상을 위한 적용요소기술 분석)

  • Kim Hyun-Il;Yu Gwon-Jong;Kang Gi-Hwan;So Jung-Hoon;Lee Kil-Song
    • Proceedings of the KIEE Conference
    • /
    • summer
    • /
    • pp.1483-1485
    • /
    • 2004
  • Photovoltaic(PV) technology is a popular part of building vocabulary. It can be used today on both existing and new buildings. Its use in the building envelope is very varied and open ways, such as roofing materials, facades, skylights and shading systems, for creative designers. So, to activate this systems demand appropriate sources of information, performance data of elements and design tools offering architects and designer. Therefore this paper describe application elements for BIPV system and then predict improvement in the generated electric power performance of balcony BIPV system.

  • PDF

A Study on the Improvement of Assessment Criteria for Housing Performance Indicator System and Green Building Certification Criteria (주택성능등급과 친환경건축물인증의 평가방법 비교를 통한 개선안 연구 -환경관련등급을 중심으로-)

  • Kim, Myoung-Shin;Hwang, Jae-Woo;Chun, Jung-Gil;Ha, Dae-Woong;Park, Kyung-Soon;Son, Won-Tug
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.9-14
    • /
    • 2009
  • A variety of Certification systems are initiated, as increased demands for housing quality of building & house owner. New building and apartment built in Seoul metropolitan should acquire Building Energy Rating System and Housing Performance Grade indication System, Green Building Certification System. Building Energy Rating System could be acquired through the certification from energy performance index of environment grade in Housing Performance Grade Indication. Between Housing Performance Grade Indication and Green Building Certification System, There are troublesome to acquire certification because a lot of assessment items are overlapped. At a result, the rational and efficient certification system should be initiated not only to avoid overlap among those certification systems and promote Green Building market share but also efficient certification system operation. We will discuss on assessment items between Housing Performance Grade Indication System and Green Building Certification System and release the improvement method those Certification Systems to avoid overlapping to assessment items.

  • PDF

A Fundamental Study on the Revision Direction of G-SEED for Green Remodeling Building (그린리모델링 건축물을 위한 녹색건축인증기준 개선방향에 대한 기초 연구)

  • Hyun, Eun-Mi;An, Kwang-Ho;Kim, Yong-Sik
    • KIEAE Journal
    • /
    • v.17 no.3
    • /
    • pp.51-58
    • /
    • 2017
  • Purpose: G-SEED's evaluation of existing buildings in Korea is an important point because the energy consumption and CO2 emissions of existing buildings are continuously increasing due to the aging of buildings over time. In 2016, the government has set up a 'Green Remodeling Certification Standard' in G-SEED in order to revitalize the green remodeling business of existing buildings. As a result, G-SEED is distinguished between buildings with green remodeling and buildings with general remodeling. Therefore, this study analyzed the system of the certification of the green remodeling building which is aimed at improving the performance of the building. Method: First, we analyze characteristics of the existing building certification standards of G-SEED(Korea), LEED(USA), and BREEAM(UK). Second, the evaluation criteria are based on the G-SEED Green Remodeling Certification, 2016, LEED for BD + C: New construction and major renovation v.4, BREEAM UK Non-Domestic Refurbishment and Fit-out 2014. Based on the analysis results, we propose the improvement direction of G-SEED Green Remodeling Certification Standard. Result: Existing buildings should be classified into 'existing building certification' for re-certification and 'green remodeling certification' accompanied by building performance improvement. In addition, building green buildings through performance improvement should include not only energy performance, but also creating a pleasant indoor environment and minimizing environmental impact. Finally, existing buildings have accumulated information on energy and resource use, and a performance improvement plan should be established based on this information.

Study on Application of Shaft Box type Balcony for Improvement of Ventilation Performance in Apartment (공동주택의 환기성능 개선을 위한 Shaft Box형 발코니의 적용성 검토)

  • Roh, Ji-Woong;Kim, Gon
    • KIEAE Journal
    • /
    • v.7 no.6
    • /
    • pp.3-8
    • /
    • 2007
  • Recently, because of the continuous rise of international oil price, energy saving is strongly demanding. So, Ecological technics of architecture such as use of natural energy have been actively explored in the field of building. In the method of utilizing natural energy, the key point is to saving energy effectively as not lowering the comfort of indoor environment, various systems investigated. Many papers about double skin facade system have been reported, it is announced broadly that the system is very effective in improvement of natural ventilation and indoor thermal environment, and also protecting outdoor sound. The shaft box facade is a special form of box window construction. It consists of a system of box windows with continuous vertical shafts that extend over a number of stories to create a stack effect. The facade layout consists of an alternation of box windows and vertical shaft segments. This research investigated the natural ventilation performance of shaft box type balcony which conform the shaft box type double skin to the exiting balcony construction. First, analyzed various types of exiting apartments, proto-type was decided. By using virtual environment Program, modeling the proto-type, compared the contribution of air temperature and the effect of outdoor air cooling. by this research, we confirmed that shaft box type balcony had many possibility for improvement of indoor environment.

Analysis of Energy Performance and Green Strategies in the Foreign High-Performance Buildings

  • Park, Doo-Yong;Kim, Chul-Ho;Lee, Seung-Eon;Yu, Ki-Hyung;Kim, Kang-Soo
    • KIEAE Journal
    • /
    • v.15 no.3
    • /
    • pp.21-28
    • /
    • 2015
  • Purpose: In this study, we analyzed the energy performance levels and high-performance technology trends through the case studies of foreign high-performance buildings. Method: Buildings built within 10 years were selected for the analysis of recent trends. we analyzed the buildings of U.S.A, Germany and Japan using LEED certified buildings, Passive House certified buildings and CASBEE certified buildings database for the case study of foreign high-performance buildings. A total of 20 high-performance buildings including 14 cases in U.S.A, 4 cases in Germany and 4 cases in Japan were selected. Annual energy consumption levels for 20 high-performance buildings were collected with the actual energy consumption data or data from simulation programs officially recognized by DOE. Annual energy consumption were compared with the energy performance standard of the office buildings in the CBECS database, ASHRAE Standard 90.1-2004 and Building Energy Efficiency Rating System in Korea. Result: The order of the green strategies applied in the main categories are Renewable Energy(63%), Indoor Environment Control(51%), Envelope Improvement(44%) and HVAC System & Control(28%). Specified strategies most widely used in the sub-categories are high-performance Insulation (70%), High Efficiency Heating, Cooling Source Equipment(85%), Photovoltaic&Solar Thermal(80%) and Daylighting(80%).

Economic Analysis Study on the R&D Effect of Performance Improvement of the Tri-generation Fuel Cell System (연료전지 삼중열병합 시스템의 성능개선 R&D 효과에 대한 경제성 분석 연구)

  • Ahn, Jong-Deuk;Lee, Kwan-Young;Seo, Seok-Ho
    • New & Renewable Energy
    • /
    • v.18 no.2
    • /
    • pp.26-39
    • /
    • 2022
  • Considering the recent substantial increase in national research and development (R&D) budgets in the energy sector there has been increased Interest in the effectiveness of government R&D investments. We conducted a case study to calculate the allowable scale and effectiveness of R&D investment by calculating the direct performance improvement effect resulting from R&D investment as an economic value. Using conditions that existed prior to R&D investments as a reference, five cases in which performance improved due to R&D investments were compared and analyzed. The government's financial investment is increasing rapidly in line with the establishment of the national hydrogen roadmap. R&D is needed to enhance the current low technology readiness level of hydrogen fuel cells compared to solar and wind energy fields. Therefore, an R&D project to improve the performance of the fuel cell system was selected as this case study's subject. Using the results in this study, the allowable level of investment in the task unit of national R&D projects could be calculated. Moreover, it is advisable to provide a standard for rational decision making for new R&D investments since it is possible to determine investment priorities among a large number of candidates.

Research on Lighting Performance Evaluation for Different Curvature Reflection Rate in Residential Space (주거공간 내 광선반 곡률 형태에 따른 채광성능평가 연구)

  • Oh, Sangwon;Lee, Heangwoo;Kim, Yongseong;Seo, Janghoo
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.27 no.6
    • /
    • pp.328-336
    • /
    • 2015
  • Currently, 22% of the total energy consumption of buildings in Korea is used for lighting. Light-shelves have garnered attention as a way to reduce consumption, but there are few studies on the types of curve and curvature, which limits the improvement of light-shelf performance and its design. This study constructed a test bed of actual residential types to evaluate the performance. Outcomes of light usage, according to variables of light-shelves, were used as indicators of performance evaluation. The results are as follows:1) Performance evaluation was conducted on flat-type light-shelves to verify performance of curvature-shelves, which are movable with a width of 200 mm, and the most ideal angle and specification per solar term are calculated. 2) The (-) shaped curvature contributed to a reduction in energy consumption and an improvement of evenness. 3) In case of light-shelves with (-) shaped curvature, an increased angle not exceeding $80^{\circ}$ of the arc contributed to an improvement of light penetration. 4) Appropriate specifications of curved light-shelves include movable types with widths of 200 mm, and angle ranges of $20^{\circ}{\sim}60^{\circ}$. 5) Light energy consumption of a movable light-shelf with curvature and width of 200 mm were reduced by 17% and 7.8% compared to a $0^{\circ}$ fixed and a movable light-shelf, respectively.

Viability of HVAC System for Energy Conservation in High Density Internal-load Dominated Buildings (고밀도 내부부하 중심 건물의 에너지 절약적 공조방식에 대한 연구)

  • Cho, Jin-Kyun;Jeong, Cha-Su;Kim, Byung-Seon
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.22 no.8
    • /
    • pp.530-537
    • /
    • 2010
  • With the advancement of technology, the density of IT equipment, heat load and power consumption continue to increase in high density internal-load dominated buildings as datacenters. To improve the HVAC system's energy performance and efficiency, there is a need to find methods of using outside air. Through cooling tower control that is based on outside wet-bulb temperature, the water-side economizer made it possible to achieve a maximum energy performance improvement of about 16.6% over the basic chilled water system, whereas the air-side economizer, through control based on outdoor air enthalpy, made it possible to achieve about 42.4% improvement.

Low-power Scheduling Framework for Heterogeneous Architecture under Performance Constraint

  • Li, Junke;Guo, Bing;Shen, Yan;Li, Deguang
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.14 no.5
    • /
    • pp.2003-2021
    • /
    • 2020
  • Today's computer systems are widely integrated with CPU and GPU to achieve considerable performance, but energy consumption of such system directly affects operational cost, maintainability and environmental problem, which has been aroused wide concern by researchers, computer architects, and developers. To cope with energy problem, we propose a task-scheduling framework to reduce energy under performance constraint by rationally allocating the tasks across the CPU and GPU. The framework first collects the estimated energy consumption of programs and performance information. Next, we use above information to formalize the scheduling problem as the 0-1 knapsack problem. Then, we elaborate our experiment on typical platform to verify proposed scheduling framework. The experimental results show that our proposed algorithm saves 14.97% energy compared with that of the time-oriented policy and yields 37.23% performance improvement than that of energy-oriented scheme on average.