DOI QR코드

DOI QR Code

A Fundamental Study on the Revision Direction of G-SEED for Green Remodeling Building

그린리모델링 건축물을 위한 녹색건축인증기준 개선방향에 대한 기초 연구

  • Hyun, Eun-Mi (Dept. of Architectural Engineering, Konkuk University) ;
  • An, Kwang-Ho (Dept. of Architectural Engineering, Konkuk University) ;
  • Kim, Yong-Sik (Dept. of Architectural Engineering, Konkuk University)
  • Received : 2017.04.13
  • Accepted : 2017.06.06
  • Published : 2017.06.30

Abstract

Purpose: G-SEED's evaluation of existing buildings in Korea is an important point because the energy consumption and CO2 emissions of existing buildings are continuously increasing due to the aging of buildings over time. In 2016, the government has set up a 'Green Remodeling Certification Standard' in G-SEED in order to revitalize the green remodeling business of existing buildings. As a result, G-SEED is distinguished between buildings with green remodeling and buildings with general remodeling. Therefore, this study analyzed the system of the certification of the green remodeling building which is aimed at improving the performance of the building. Method: First, we analyze characteristics of the existing building certification standards of G-SEED(Korea), LEED(USA), and BREEAM(UK). Second, the evaluation criteria are based on the G-SEED Green Remodeling Certification, 2016, LEED for BD + C: New construction and major renovation v.4, BREEAM UK Non-Domestic Refurbishment and Fit-out 2014. Based on the analysis results, we propose the improvement direction of G-SEED Green Remodeling Certification Standard. Result: Existing buildings should be classified into 'existing building certification' for re-certification and 'green remodeling certification' accompanied by building performance improvement. In addition, building green buildings through performance improvement should include not only energy performance, but also creating a pleasant indoor environment and minimizing environmental impact. Finally, existing buildings have accumulated information on energy and resource use, and a performance improvement plan should be established based on this information.

Keywords

References

  1. 민전식, 한미일 녹색건축인증제도 평가항목 비교연구, 공주대학교 대학원 석사학위논문, 2017 // (Min, Jun-Sik, "A Study on Comparison in Green Building Certification system of Korean, US, and Jpan", Graduate School of Kongju National University, 2017)
  2. 박지혜, 박상동, 이상홍, 태춘섭, "리모델링 건축물 활성화를 위한 녹색 건축 인증기준의 에너지 성능 평가기준 개선연구", 대한건축학회 춘계학술발표대회 논문집, 제34권 제1호, 2014 // (Park, Ji-Hye, Park, Sang-dong, Lee, Sang-Hong, Tae, Choon-Seob, "A Study on the Improvement of Energy Performance Assessment Criteria in G-SEED for Remodeling", Journal of AIK, Vol..34, No.1, 2014)
  3. 한국건설기술연구원 , "건물외피 시스템의 그린리모델링 최적화 기술 개발", 한국건설기술연구원, 2015 // (KICT, "Development of the Green Remodeling Technologies for Envelope Systems in Existing Buildings", KICT, 2015)
  4. BRE, BREEAM UK Refurbishment and Fit-out 2014 Non-domestic buildings Technical Manual, BRE, 2014
  5. USGBC, LEED Green Building Design and Construction Reference Guide, USGBC, 2014

Cited by

  1. Application of Green Remodeling to the Urban Renewal Project for Gyeongsangbuk-do Province vol.32, pp.3, 2017, https://doi.org/10.6107/jkha.2021.32.3.147