• Title/Summary/Keyword: Improvement of Water quality

Search Result 1,146, Processing Time 0.034 seconds

A Study on the Quality Improvement of Secondary Treatment Effluent Utilize the Natural Purification Method (자연정화공법을 이용한 2차 하수처리수의 수질 개선에 관한 연구)

  • Ahn, Tae Woong;Choi, I Song;Oh, Jong Min
    • Journal of Environmental Impact Assessment
    • /
    • v.18 no.2
    • /
    • pp.79-87
    • /
    • 2009
  • This study was performed for the application of porous concrete blocks and aquatic plants for the water purification in small urban stream. This study investigated the ability of water purification according to various environments, algae and aquatic plants. When the porous concrete was used as contact media, the average removal efficiencies of SS, BOD and COD were 85~95%, 50~60% and 65~75%, respectively. Also, when the porous concrete and aquatic plants was used the average removal efficiency of SS, BOD and COD were 90~95%, 60~70% and 70~80%, respectively. As the results, average removal efficiency of total nitrogen, at the condition of the porous concrete and aquatic plants, was about 40-50%, then, that of total phosphorus was about 60-70%.

A study on the flood control of the Mekong Delta (메콩강하구의 홍수조절)

  • 최병습
    • Proceedings of the Korean Society of Agricultural Engineers Conference
    • /
    • 1998.10a
    • /
    • pp.299-304
    • /
    • 1998
  • Flood control of the Mekong delta should be developed over time for rural as well as urban areas. The hydraulic modelling effort is aimed an investigating flow distribution and water level. For the flood control study the flood model made with the VRSAP program is used. Concerning future improvement of the models it is recommended to improve the quality of water level and discharge, extend the number of the measuring locations needed for input for the models, systematically review and analyze future measurement campaigns in order to obtain better understanding of the complex hydraulic aspects, verify and update the topographical data used to model the rivers and cannals, carry out detailed calibration and verification of the models on water levels, discharges etc.

  • PDF

Influence of Admixtures on Strengths and Freezing and Thawing Resistance of Cement Mortar for Precast Products (혼화재료가 공장제품용 시멘트 모르타르의 강도 및 동결융해 저항성에 미치는 영향)

  • 한천구;신병철;김기철;이상태
    • Journal of the Korea Concrete Institute
    • /
    • v.12 no.3
    • /
    • pp.11-19
    • /
    • 2000
  • It has been reported that few manufacturers of cement mortar for precast products use chemical and mineral admixture due to the absense of restrictions related to the application of admixture and the poor manufacturing facilities. Therefore, this paper is intended to contribute to the improvement of quality by investigating the properties of cement mortar for precast products using fly ash, blast furnace slag and AE water reducing agent. According to the test results. it was found that the cement mortar products using fly ash and AE water-reducing agent had better qualities than those of ordinary portland cement.

The Efficiency Improvement of Flocculation Facilities in Water Treatment Plants (정수장 응집설비의 효율증대 방안연구)

  • Jeon, Bok-Su;Lee, Eun-Woong;Lim, Su-Saemg;Choi, Jae-Young;Kim, Hong-Kwon
    • Proceedings of the KIEE Conference
    • /
    • 2000.07b
    • /
    • pp.952-954
    • /
    • 2000
  • In the cleaning-water treatment process, the flocculation machine is operated by the V.S motor when the coagulation-facility of the coagulation-process is operated. But after the flocculation machine is stopped by an instantaneous power failure, the transient takes place when the coagulation facility is re-started. To improve the transient state, we developed the reinforcement-circuit which had the function of soft-start and adapted to the field. As a result of this study, we reduced the damage of facilities and had the safety in maintaining the quality of water and improved the efficiency in the maintenance and the management.

  • PDF

A Study on the Improvement for Workability of Concrete with Belite Cement (4종(벨라이트)시멘트의유동성 향상에 대한 연구)

  • 하상운;구본창;김동석;하재담;이종열
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2000.04a
    • /
    • pp.247-250
    • /
    • 2000
  • As construction technology advances, most of concrete structures are becoming larger and taller. Therefore, high strength and high quality concrete is necessary for them. Nowadays, the proposal of using type IV(belite cement) is investigated to satisfy high flowing, low heat, and ho호 strength. In this study, the flow value and compressive strength of mortar were investigated according to usage of AE high range water reducer. And the slump flow value, falling time and heigth difference of concrete with beilte cement and ordinary cement were examined depending on water cement ratio, sand ratio and unit water weigth, and compressive strength to checked depending on age.

  • PDF

Detention Orifice Design for Non-point Source Management Using SWMM (SWMM을 이용한 비점오염원 관리 저류지의 오리피스 설계기법 연구)

  • Cho, SeonJu;Kim, Sangdan
    • Journal of Korean Society on Water Environment
    • /
    • v.28 no.5
    • /
    • pp.686-692
    • /
    • 2012
  • This study illustrates how to design and evaluate a non-point sources management detention pond using SWMM. In particular, special attention is given to the orifice design. In SWMM, orifice properties that need to be defined include its height above the bottom of the storage unit, its type, its geometry and its hydraulic properties. Among the various characteristics of orifice, the orifice hole size which is closely related to hydraulic retention time is focused in this study. Sensitivity analysis of orifice size in annual non-point sources reduction efficiency is carried out. In addition, a methodology which can be used to design a virtual junction in SWMM has been proposed to quantify water quality improvement triggered by the detention pond installation. As a result, it is recommended that a detention outlet should be designed to be about 2 to 3 days of hydraulic retention time.

The Analysis of Faults for the Excitation System of Generator (발전기 여자시스템의 에러 해석)

  • Ok, Yeon-Ho;Lee, Eun-Woong;Byun, Ill-Hwan;Paik, Doo-Hyun
    • Proceedings of the KIEE Conference
    • /
    • 2005.07b
    • /
    • pp.1047-1049
    • /
    • 2005
  • Hydraulic power plant is operated for peak load and frequently start-stop because of no continuous operation. So the fault can happen due to field voltage swing in the middle of starting or reactive power swing on the line. On this research, we want to analyze that this status influence on line and generator. we hope this research can contribute to the power quality improvement.

  • PDF

The improvement of the operating process of sewage treatment plants in the upstream area of dam by MASS FLOWmodelling (MASS FLOW 모델링을 통한 댐상류지역의 공공하수처리시설 공정개선방안)

  • Lee, Hyunseop;Lee, Jiwon;Gil, Kyungik
    • Journal of Wetlands Research
    • /
    • v.22 no.2
    • /
    • pp.130-138
    • /
    • 2020
  • As of 2017, the sewerage penetration rate of Seoul and metropolitan cities is more than 90%, and the number of domestic sewage treatment plants increased by 25% from 3,064 in 2010 to 4,072 in 2017. Among them, sewage treatment plant operated by SBR system is 585, which is 17% higher than 2010. In order to improve the water quality of the water source and improve the operation of the small sewage facilities, the improvement of the process was studied by applying the modelling to 49 facilities of the sewage treatment plant in Andong Imha dam area with more than 500㎥/day 3 places and 46 places less than 500㎥/day. As an improvement plan for modelling, candidate data were derived by reviewing operation data for 5 years. 49 facilities are operated by 12 types of operating processes. Among them, 1 place mort than 500㎥/day with SBR method and 9 facilities with less than 500㎥/day were selected by dividing 46 sites into 3 types. As a result of applying modelling to more than 500㎥/day, it was possible to improve the quality of discharged water through SRT control and it was found that applying model to sites of small scale treatment plants can improve the removal efficiency of TP by up to 14.4%. As a result, the data of this study could be used to improve and improve the operation of sewage treatment plants and RCSTP(Rural Community Sewage Tratment Plant).

A Study on Applicability of Air-lift Pump for Deep Seawater pumping (해양심층수 취수를 위한 기포펌프의 적용성 연구)

  • Shin P. K.;Kim H J.;Hong S. W.;Choin H S.
    • Proceedings of the Korea Committee for Ocean Resources and Engineering Conference
    • /
    • 2004.11a
    • /
    • pp.13-16
    • /
    • 2004
  • Deep sea water has mid temperature, abundant nutrients and minerals, and good tooter quality. For the purpose of drawing up deep sea water without pump pit construction, tile authors are considering to use air-lift pump. This report describes fundamental experimental investigation for air-lift pump characteristic and improvement in efficiency.

  • PDF

Effective Coastal Water Quality Management and Marine Environmental Impact Assessment (연안의 효율적 수질관리 방향과 해양환경영향평가)

  • Lee, Dae-In;Eom, Ki-Hyuk;Kim, Gui-Young;Hong, Sok-Jin;Lee, Won-Chan;Jang, Ju-Hyoung
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.14 no.1
    • /
    • pp.29-37
    • /
    • 2008
  • This study examined principles and techniques of efficient water quality management as well as total coastal pollutant loads and the relevant examples in the advanced countries from the viewpoints of water quality improvement and pollution control in coastal areas. The problems and improvements in an estimation of the current total pollutant loads were also pointed out. In addition, discussion was made on the relationship between total pollutant loads and environmental capacity as well as particulars requiring extensive examination on access to and study on water quality model used as prediction tool for marine environment. Furthermore, this study proposed details of and improvement plans for water quality control to be reflected and absorbed into systems and policies related to coastal water quality. In coastal areas, which are subject to total coastal pollutant loads, it is necessary to calculate pollutant loads reduction and allocation, to propose them in detail in statement in relations to new pollution sources for the corresponding projects or plans in environmental impact assessment and prior environmental review system. Also, in relations to regional plans for coastal management, the local government concerned must focus more on environmental management plan to implement data on pollution sources and pollutant loads flown into sea areas under basic jurisdiction, therefore it is required to actively respond to expansion and introduction of total coastal pollutant loads system in the future. Total coastal pollutant loads system must be expanded and executed by considering characteristics of sea area and changes in the environment of land. For pollution sources in land, the competent authorities in charge of coastal environment will need to initiatively administer supervision, monitoring activities and achieve integration and operation of the related laws by preparing legal bases for management system or adjusting the related laws.

  • PDF