• 제목/요약/키워드: Impression surface

검색결과 117건 처리시간 0.02초

TENSILE BOND STRENGTH BETWEEN ELASTOMERIC IMPRESSION MATERIALS AND TRAY RESINS DEPENDING ON THE THICKNESS OF THE TRAY ADHESIVE

  • Kim, Tae-Won;Moon, Hong-Seok;Lee, Keun-Woo;Chung, Moon-Kyu
    • 대한치과보철학회지
    • /
    • 제44권6호
    • /
    • pp.699-711
    • /
    • 2006
  • Statement of problem. Elastomeric impression materials have been widely used to obtain an accurate impression. However there have not been enough studies on the influence of the thickness of the tray adhesives on the bonding strength between the trays and the elastomeric impression materials. Purpose. In order to understand the relationship between the thickness of the tray adhesive and the tensile bond strength and to suggest the thickness at which the bonding strength is strongest, tensile bond strength related to the thickness of adhesives of 3 different elastomeric impression materials were tested. Materials and methods. 3 impression materials, $Permlastic^{(R)}$. Regular Set(Kerr Corp., Romulus, Michigan, U.S.A.), $Impregum^{TM}$ $Penta^{TM}$(3M ESPE, Seefeld, Germany), and Aquasil Ultra Monophase Regular Set Smart Wetting.(Dentsply Caulk, Milford, Delaware, U.S.A.), were used in this study, and tray adhesives from the same manufacturers of the impression materials were used, which were Rubber Base Adhesive, Polyether Adhesive, and Silfix, respectively. The tray specimens were prepared by autopolymerizing the tray material(Instant Tray Mix, Lang, Wheeling, Illinois, U.S.A.), and a PVC pipe was used to house the impression material. In group A, tray adhesives were applied in multiple thin layers of 1 to 5 and in group B, adhesives were applied only once, in the thickness equivalent to several applications. Lightness($L^*$) of the adhesion surface was measured with a spectrophotometer(CM-3500d, Konica Minolta, Sakai, Osaka, Japan). The tensile bond strength of the elastomeric impression material and the tray resin was measured with universal materials testing machines(Instron, Model 3366, Instron Corp, Nowood, Massachusetts, U.S.A.). A formula between the number of adhesive application layers and the lightness of the adhesion surface was deduced in group A, and the number of adhesive layers in group B was estimated by applying the lightness($L^*$) to the deduced formula. Results. 1. In group A, a statistically significant increase in tensile bond strength appeared when the number of application layers increased from 1 to 2 and from 4 to 5, and no significant difference was present between 2, 3, and 4 layers in Permlastic. In Impregum, the tensile bond strength was significantly increased when the number of adhesive layers increased from 1 to 3, but no significant difference after 3 layers. In Aquasil, the tensile bond strength significantly increased as the number of application layers increased up to 4 but showed no significant difference between 4 and 5. 2. In group B, the tensile bond strength was decreased when the thickness of the adhesive increased in Permlastic. Impregum showed an increased tensile bond strength when the thickness of the adhesive was increased. In Aquasil, the tensile bond strength increased as the number of adhesive application layers increased up to approximately 2.5 layers but it sharply decreased after approximately 4.5. Conclusion. From the study, the common idea that it is better to apply a thin and single coat of tray adhesive needs correction in more detailed ways, and instructions on some of the tray adhesives should be reconsidered since there were several cases in which the tensile bond strength increased according to the increase in the thickness of the adhesives.

Comparison of the accuracy of digitally fabricated polyurethane model and conventional gypsum model

  • Kim, So-Yeun;Lee, So-Hyoun;Cho, Seong-Keun;Jeong, Chang-Mo;Jeon, Young-Chan;Yun, Mi-Jung;Huh, Jung-Bo
    • The Journal of Advanced Prosthodontics
    • /
    • 제6권1호
    • /
    • pp.1-7
    • /
    • 2014
  • PURPOSE. The accuracy of a gypsum model (GM), which was taken using a conventional silicone impression technique, was compared with that of a polyurethane model (PM), which was taken using an iTero$^{TM}$ digital impression system. MATERIALS AND METHODS. The maxillary first molar artificial tooth was selected as the reference tooth. The GMs were fabricated through a silicone impression of a reference tooth, and PMs were fabricated by a digital impression (n=9, in each group). The reference tooth and experimental models were scanned using a 3 shape convince$^{TM}$ scan system. Each GM and PM image was superimposed on the registered reference model (RM) and 2D images were obtained. The discrepancies of the points registered on the superimposed images were measured and defined as GM-RM group and PM-RM group. Statistical analysis was performed using a Student's T-test (${\alpha}=0.05$). RESULTS. A comparison of the absolute value of the discrepancy revealed a significant difference between the two groups only at the occlusal surface. The GM group showed a smaller mean discrepancy than the PM group. Significant differences in the GM-RM group and PM-RM group were observed in the margins (point a and f), mesial mid-axial wall (point b) and occlusal surfaces (point c and d). CONCLUSION. Under the conditions examined, the digitally fabricated polyurethane model showed a tendency for a reduced size in the margin than the reference tooth. The conventional gypsum model showed a smaller discrepancy on the occlusal surface than the polyurethane model.

치과용 탄성 인상재를 기반으로 채득된 디지털 모형의 정확성 연구: 3차원 중첩 분석 (Accuracy of Digital Impression Made from Different Elastomeric Impression Materials: Three-Dimensional Superimpositional Analysis)

  • 김기백;정재관;김재홍
    • 치위생과학회지
    • /
    • 제14권2호
    • /
    • pp.94-100
    • /
    • 2014
  • 본 연구는 임상에서 널리 사용되고 있는 3종류의 탄성 인상재를 치과용 백색광 스캐너로 스캔하여 얻어진 데이터와 석고 지대치 모형과의 차이를 비교분석하였다. 인상재의 물성 차이가 3차원 디지털 모형의 정확성에 어떠한 영향을 미치는지 3차원 중첩 분석법을 통해 평가함으로써 다음과 같은 결과를 얻었다. 석고 지대치 모형과 3종류의 인상재를 토대로 채득된 디지털 모형의 차이를 비교한 결과, HB 그룹이 $9.80{\pm}1.52{\mu}m$ 로 가장 큰 차이를 보였으며, XLB 그룹이 $5.10{\pm}1.45{\mu}m$로 가장 작은 차이를 나타내었다. 음형의 인상체 간의 정확성에 있어서는 측정된 평균값이 통계적으로 유의한 차이를 보였다(p<0.05). Color difference map의 결과에서도 HB 그룹에 비해 XLB 그룹이 오차가 0에 가까운 연두색의 분포가 넓게 나타났기에, 더욱 안정적이며 정확한 디지털 모형 채득이 가능한 탄성 인상재라는 결론을 내릴 수 있다. 아직까지는 음형의 인상체 스캔방식은 표면의 혈흔이나 난반사, 중합 수축 등 좀 더 개선하고 보완해야 할 문제점들이 존재하기 때문에 널리 사용하진 않지만, 석고 모형과 비교하였을 때 전체적인 오차범위가 크지 않기에 임상적으로 허용될만한 수준으로 생각된다.

DL-alanine과 1,2-indanedione을 이용한 종이에 남은 족적의 증강 (Development of latent footwear impression on porous surfaces using DL-alanine solution and 1,2-indanedione solution)

  • 홍성욱;김은아;박미선;이은혜
    • 분석과학
    • /
    • 제30권6호
    • /
    • pp.303-311
    • /
    • 2017
  • 잠재지문 증강시약인 1,2-indandione (1,2-IND) 용액을 사용하여 종이에 유류된 족적의 형광을 얻는 방법을 연구하였다. 인쇄물이 출력된 A4 용지에 유류된 dry origin 및 wet origin 족적에 아미노산의 일종인 DL-alanine 용액과 아미노산 검출시약인 1,2-IND 용액을 뿌려서 DL-alanine-1,2-IND 이성분착물을 만들었다. 이 이성분착물은 족적에 있는 미량의 금속성분과 반응하여 광발광을 내는 삼성분착물을 형성함으로써 족적의 형광을 관찰할 수 있었다. 그러나 1,2-IND 용액 대신 5-methylthioninhydrin (5-MTN) 용액을 이용하면 처리 조건을 동일하게 유지해도 족적의 형광이 일정하게 관찰되지 않았다. DL-alanine 용액과 1,2-IND 용액으로 처리한 족적을 다양한 온도조건 (30, 40, $50^{\circ}C$)과 다양한 습도조건 (30, 40, 50, 60 % RH)에서 보관한 결과 온도와 습도가 높을수록 족적과 바탕면의 대조비가 감소하였다. DL-alanine 용액과 1,2-IND 용액으로 처리한 족적을 $30^{\circ}C$, 30 % RH에서 1 h 동안 보관하면 족적의 최적 형광을 얻을 수 있었다. 저자들이 개발한 방법의 감도를 black gelatin lifting, 2,2'-dipyridil 용액 처리 방법, 8-hydroxyquinoline 용액 처리방법의 감도와 비교하였다. 그 결과 저자가 개발한 방법의 감도는 gelatin lifting 방법보다는 떨어졌으나 2,2'-dipyridil 용액 혹은 8-hydroxyquinoline 용액 처리방법보다는 우수하였다.

고무 인상재의 크기 안정성 및 친수성에 관한 연구 (DIMENSIONAL STABILITY AND WETTABILITY OF RUBBER IMPRESSION MATERIALS)

  • 강충희;방몽숙
    • 대한치과보철학회지
    • /
    • 제30권2호
    • /
    • pp.233-245
    • /
    • 1992
  • The purpose of this study was to evaluate the demensioal stability and wettability of several rubber impression materials. Impressions were made from a metal master die machined to stimulate five full veneer crown preparations symmetrically placed in an arch form. Cast from impressions were measured about ; 1) intrapreparation distance 2) lower base diameter 3) length. For comparing materials were formed against a smooth surface. The advancing contact angle of a saturated aqueous solution of $CaSO_4$ on the impression materials was measured after 1 minute. Mean contact angle were calculated and results were analyzed. Results were as follows : 1. As the intrapreparation distance, hydrophilic addition-cured silicone had the smallest change and condensation-cured silicone had the largest one. 2. As the lower base diameter, traditional addition-cured silicone had the smallest change and polyether had the largest one. 3. As the height, traditional addition-cured silicone had the smallest change and polyether had the largest one. 4. As the contact angle, polyether had the smallest change and condensation-cured silicone had the largest one.

  • PDF

수종의 조직 양화재의 침수시간과 분액비에 따른 표면 거칠기의 변화 (Changes of the surface roughness depending on immersion time and powder/liquid ratio of various tissue conditioners)

  • 김경수;문홍석;심준성;정문규
    • 대한치과보철학회지
    • /
    • 제47권2호
    • /
    • pp.108-118
    • /
    • 2009
  • 연구목적: 1961년 Chase에 의해 처음 소개된 기능 인상법(functional impression technique)은 기존 의치에 이장된 조직 양화재(tissue conditioner)를 이용하여 실제 기능 운동 하에서 동적인 지지 조직의 인상과 기능적이며 생리적인 의치 변연부의 형태와 길이를 기록하는 술식이다. 조직 양화재가 기능 인상법의 재료로 사용되기 위해서는 체적 안정성, 미세부 재현성, 흐름성 등의 특성과 함께 치과용 석고와의 적합성(compatibility)을 고려하여야 한다. 하지만 기능 인상법 재료로 조직 양화재를 사용할 경우 구강내 환경 속에서 시간이 지남에 따라 석고 표면 거칠기에는 어떠한 영향을 미칠지 또한 그에 따라 석고 표면의 변화를 고려하여 어느 정도 기간 동안 구강 내에 유지하는 것이 좋을지에 대한 연구는 거의 없는 상황이다. 이에 본 연구는 조직 양화재를 기능 인상법의 재료로서 사용할 경우, 조직 양화재의 종류와 분액비, 침수시간이 치과용 석고 표면 거칠기에 어떠한 영향을 주는지 알아보고자 하였다. 연구 재료 및 방법: 임상적으로 많이 쓰이는 3종의 조직 양화재(Coe-Comfort, Visco-Gel, Soft-Liner)로 제조사에서 추천하는 분액비(P/L ratio)를 기준으로 표준 분액비에 따라 혼합한 군(R), 분말의 양을 20% 많이 혼합한 군(M), 분말의 양을 20% 적게 혼합한 군(L)으로 나누어 조직 양화재를 혼합하여 직경 20 mm, 두께 2 mm의 시편을 제작하였다. 각 조직 양화재 시편들을 다시 인공 타액 속의 침수시간(0시간, 1일, 3일, 5일, 7일)에 따라 5개의 군으로 나눈 뒤 인공 타액에 완전히 담구어 $37^{\circ}C$에서 보관하였다. 정해진 침수시간이 경과한 시편을 꺼내서 초경석고를 부어 석고 시편을 제작한 뒤 조직 양화재와 접해있던 석고 시편 표면의 거칠기를 접촉식 표면 조도기(Surfcoder SEF-30D, Kosaka laboratory Ltd., Tokyo, Japan)로 측정하여 다음과 같은 연구 결과를 얻었다. 결과 및 결론: 1. 조직 양화재로 부터 만들어진 석고 모형의 표면 거칠기에 주된 영향을 미치는 요인은 기능 인상을 채득하기 위해 구강 내에 조직 양화재를 위치시키는 기간이었고, 그 외에 조직 양화재의 종류와 분액비도 통계학적으로 유의한 영향을 미치는 요인이었다. 2. 3가지 P/L ratio 실험 조건 모두에서 Visco-Gel과 Soft-Liner 간에는 석고 모형의 표면 거칠기값이 침수시간이 변함에 따라 통계학적으로 유의성 있는 차이를 보이지 않았지만, Coe-Comfort의 경우에는 침수시간이 변함에 따라 Soft-Liner와 Visco-Gel보다 석고 모형의 표면 거칠기값이 통계학적으로 유의성 있게 더 큰 값을 보였다. 3. 3종의 실험 대상 조직 양화재 모두에서 R(recommended)와 M(more) group 간에는 석고 모형의 표면 거칠기값이 침수시간이 변함에 따라 통계학적으로 유의성 있는 차이를 보이지 않았지만, L(less) group의 경우에는 침수시간이 변함에 따라 R과 M group보다 석고 모형의 표면 거칠기값이 통계학적으로 유의성 있게 더 큰 값을 보였다. 이러한 연구 결과로부터 석고 모형의 표면 거칠기에는 구강 내에서의 시간이 가장 큰 영향을 나타내며, 조직 양화재의 종류와 분액비도 영향을 미칠 수 있기 때문에 술자가 기능 인상 채득 시에 적절한 구강 내 적용시간에 대해서 잘 이해하고 있고, 기능 인상에 적합한 조직 양화재를 선별할 수 있다면 조직 양화재를 이용하여 유용하게 기능 인상을 채득할 수 있을 것이다.

유지형태에 따른 치과 인상용 트레이의 유지력에 관한 연구 (Retentive Force of Dental Impression Tray According to Retention form)

  • 최민호;신동국;김민정;오상천;동진근
    • 구강회복응용과학지
    • /
    • 제20권1호
    • /
    • pp.43-50
    • /
    • 2004
  • This study was performed to measure the retentive force of dental impression tray according to retention form. The 9 resin beams($30{\times}60{\times}2.5mm$) were made of visible light-curing tray resin according to the surface texture, the size of hole and the number of rim. The resin block was fabricated in width 50mm, length 30mm, heght 40mm to maintain an even hydrocolloid impression material. The retentive force between the resin beam and hydrocolloid impression material was measured by Universal Testing Machine(Zwick Z020, Zwick Co., Germany). The results obtained in this study were as follows : 1. The retentive force of the resin beam with bilateral 4 rims, 2mm holes(9group) was highest(9.18kg), and the polishing resin beam(2group) was worst(4.85kg). 2. There was no significant difference between the polished the resin beam(2group) and the contrast resin beam(1group). 3. The retentive force of the rimmed resin beam was higher than the perforated resin beam. 4. The retentive force of the 2mm perforated resin beam(4group) was higher than the 3mm perforated resin beam(3group). 5. As increasing the number of rim increased the retentive force.

치과용 백색광 스캐너를 이용한 impression scanning의 반복 측정에 대한 안정성 평가 (Evaluation on the repeatability of dental white light scanner-based digital impression)

  • 전진훈;이경탁;김혜영;김지환;김웅철
    • 대한치과기공학회지
    • /
    • 제35권1호
    • /
    • pp.37-42
    • /
    • 2013
  • Purpose: The purpose of this study was to evaluate the repeatability of dental white light scanner. Methods: The impression(Zerosil, Dreve, Germany) were digitized in white light scanner(Identica, Medit, Korea) to create 3-dimensional surface-models. The distribution of the discrepancies between the number of points in the corresponding CRM models and the point clouds in the others were measured by a matching-software(PowerInspect 2012, Delcam Plc, UK). The discriptive statistics were used for statistical analysis(SPSS 20.0). Results: The measurement of repeatablity showed very good reliability. The mean(SD) discrepancy value on the white light scanner digital models was 8.7(0.67) ${\mu}m$, based on SD and absolute mean values. Conclusion: These in vitro studies showed that repeatability of dental white light scanner is high reliability. These results can be confirmed in further clinical studies.

DENTIN BONDING AGENTS들의 상아세관 밀봉 효과에 관한 연구 (STUDY ON DENTINAL TUBULES SEALING EFFECTS OF DENTIN BONDING AGENTS)

  • 권오택;박동수
    • Restorative Dentistry and Endodontics
    • /
    • 제18권2호
    • /
    • pp.483-496
    • /
    • 1993
  • Dentin hypersensitivity medicaments such as Gluma, Scotchbond 2, All-Bond 2, which are resin adhesives, were used to compare the sealing effects of dentinal tubule under mechanical stress. Topical application of above medicaments on the dentin surfaces of extracted teeth followed by artificial tooth brushing for 6 weeks was performed for the comparison. The following conclusions on the degree of dentinal tubule exposure versus time by were reached by using polyvinyl siloxane impression material for taking the impression, epoxy resin for the duplication and SEM for observing the surface. 1. SEM was used to compare the accuracy of the duplicated surface, but no differences were found when teeth samples and the duplicated surfaces were observed. 2. After comparing the degree of dentinal tubules exposure with varnish applied contrast group, resin adhesive materials showed much less exposure as time went by. 3. The results indicated that AU-Bond 2 adhesive, under mechanical stress, showed lesser exposure of dentinal tubules comparing with Gluma and Scotchbond 2 adhesives After the results were put together, it was demonstrated that resin replica method is an useful way to evaluate the treatment effects of the dentinal tubule hypersensitivity medicaments. Also, it was noticed that under mechanical stress, All-Bond 2, classified as fourth generation, illustrated the best dentinal tubules sealing effects.

  • PDF

유리섬유 보강재를 삽입한 하악 레진의치 인상면의 정밀성 평가 (Precision evaluation of impression surface of lower complete dentures reinforced with glass fiber)

  • 김동연;양천승;이광영;김지환
    • 대한치과기공학회지
    • /
    • 제42권1호
    • /
    • pp.27-33
    • /
    • 2020
  • Purpose: This study is to compare and analyze the precision of glass fiber resin dentures. Methods: A lower edentulous model was prepared. Ten study models were produced using Type IV stone. Ten wax lower resin dentures containing artificial teeth were prepared. The lower wax denture was buried with plaster and deflasking was performed to remove the wax. Five conventional lower resin dentures and five glass fiber lower resin dentures were produced. The scanning spray was coated on the impression surface and then scanned. Independent sample t-test were performed using statistical software. Results: In the color different map, which is a qualitative evaluation, the green area of the precision of the conventional lower resin denture occupied the whole. The glass fiber conventional resin dentures had many negative and positive area. In quantitative evaluation, the RMS of conventional lower resin was 89.83 ㎛ and that of fiberglass resin was 224.92 ㎛. The two groups showed statistically significant differences (p<0.05). Conclusion: Conventional lower resin dentures were superior in precision, and glass fiber resin dentures would have to improve the process.