Limitation of Nitrogen ion Implantation and Ionplating Techniques Applied for Improvement of Wear Resistance of Metallic Implant Materials (금속 임플란트 소재의 내마모성 향상을 위하여 적용되는 질소 이온주입 및 이온도금법의 한계)

  • 김철생
    • Journal of Biomedical Engineering Research
    • /
    • v.25 no.2
    • /
    • pp.157-163
    • /
    • 2004
  • Nitrogen ion implantation and ion plating techniques were applied for improvement of the wear resistance of metallic implant materials. In this work, the wear dissolution behaviour of a nitrogen ion implanted super stainless steel (S.S.S, 22Cr-20Ni-6Mo-0.25N) was compared with those of S.S.S, 316L SS and TiN coated 316L SS. The amounts of Cr and Ni ions worn-out from the specimens were Investigated using an electrothermal atomic absorption spectrometry. Furthermore, the Ti(Grade 2) disks were coated with TiN, ZrN and TiCN by use of low temperature arc vapor deposition and the wear resistance of the coating layers was compared with that of titanium. The chemical compositions of the nitrogen ion implanted and nitride coated layers were examined with a scanting auger electron spectroscopy. It wat observed that the metal ions released from the nitrogen ion implanted S.S.S surface were significantly reduced. From the results obtained, it was shown that the nitrogen ion implanted zone obtained with 100 KeV ion energy was easily removed within 200,000 revolutions from a wear dissolution testing under a similar load condition when applied to artificial hip joint. The remarkable improvement in wear resistance weir confirmed by the nitrides coated Ti materials and the wear properties differ greatly according to the chemical composition of the coating layers. for specimens with the same coating thickness of about 3$\mu\textrm{m}$, TiCN coated Ti showed the highest wear resistance. However, after removing the coating layers, the wear rates of all nitrides coated Ti reverted to their normal rates of below 10,000 revolutions from Ti-disk-on-disk wear testing under the same load condition. From the results obtained, it is suggested that the insufficient depth of the 100 Kel N$\^$+/ ion implanted zone and of the nitrides coated layers of 3$\mu\textrm{m}$ are subject to restriction when used as frictional parts of load bearing implants.

Reproducibility of Applicator Position with High dose rate brachytherapy in uterine cervical cancer (자궁경부암 환자의 근접치료시 재현성 평가)

  • Kim Jong-Hwa;Son Jung-Hae;Jung Chil;Kim Mi-Hwa
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.15 no.1
    • /
    • pp.29-33
    • /
    • 2003
  • I. Purpose Brachytherapy is the main component in treatment of patients with uterine cervical cancer. The reproducibility of applicator position in the same patient at repeated treatments was very important for accurate dose delivery. It was aimed to evaluate the change of applicator location between each high dose rate(HDR) brachytherapy insertion in the patients with uterine cervical cancer. II. Materials and Methods From January 1999 to October 2001, total 52 patients were treated with external beam radiotherapy and HDR brachytherapy (Microselectron, Nucletron). During six to seven times of brachytherapy, all patients had three treatment plans. From the orthogonal radiographs, we measured the following variables; height from upper border of pubic bone to os (HPO), distance from sacral promontory to tip of tandem (DST), distance from coccyx to os (DCO), distance from tip of right ovoid to os (DRO), distance from tip of left ovoid to os (DLO), and distance from center of the first tandem source to ovoid (DTO). To evaluate the reproducibility of applicator position, it was calculated the standard deviation of differences between three insertions for the 7 parameters in each patient. III. Results The ranges of standard deviations of interfractional differences for the variables were as follows. 1)HPO : $0{\sim}0.79cm$ 2)DST : $0{\sim}0.9cm$ 3)DCO : $0.06{\sim}0.76cm$ 4)DRO : $0{\sim}0.53cm$ 5)DLO : $0{\sim}0.45cm$ 6) DTO $0{\sim}0.36cm$ IV. Conclusions There was some change in applicator position on repeated implants in our study. But variation of the interfractional differences was minimal; in all parameters, there were less than 1 cm. We are continued to try for reducing the geometric variation between each procedure.

  • PDF

Patterns of Pulsatile and Surge Modes of Follicle-Stimulating Hormone Treated with Different Progesterone Levels in Ovariectomized Goats (난소제거된 Shiba 염소에서 다른 농도의 Progesterone 처치에 의한 FSH Surge 및 Pulse 분비에 미치는 영향)

  • Kim, Seung-Joon;Tanaka, Tomomi;Kamomae, Hideo
    • Journal of Veterinary Clinics
    • /
    • v.28 no.2
    • /
    • pp.225-231
    • /
    • 2011
  • The objective of the present study was to determine the progesterone levels that effects on the pulsatile and surge modes of FSH secretion. In previous studies we have shown that LH surge occurred in the follicular levels of progesterone, whereas there was no surge mode secretion of LH in either the sub luteal or luteal levels of progesterone. LH pulsatile frequencies were high in two groups such as follicular level and sub luteal level. But in the luteal level of progesterone the pulsatile pattern of LH were strongly suppressed. Namely, sub luteal levels of progesterone, around 1 ng/ml, completely suppressed the LH surge but did not affect the pulsatile frequency of LH secretion. Because of this we hypothesized that the two secretory patterns of FSH are similar to that of LH. Long-term ovariectomized Shiba goats that had received implants of estradiol capsules and three different progesterone silastic packet inducing follicular, subluteal and luteal levels of progesterone were divided into three groups such as non-P, low-P and high-P group. Blood samples were collected daily throughout the experiment for the analysis of gonadal steroid hormone levels and at 10-min intervals for 8 h on Days 0, 3, and 7 (Day 0: just before progesterone treatment) for analysis of the pulsatile frequency of FSH secretion. Then estradiol was infused into the jugular vein of all animals at a rate of 3 ${\mu}/h$ for 16 h on Day 8 to determine whether an FSH surge was induced. Blood samples were collected every 2 h from 4 h before the start of the estradiol infusion until 48 h after the start of the infusion. In each group, the mean ${\pm}$ SEM concentration after progesterone implant treatment was 3.3 ${\pm}$ 0.1 ng/ml for the high P group, 1.1 ${\pm}$ 0.1 ng/ml for the low P group, and < 0.1 ng/ml for the non-P group, concentrations similar to the luteal levels, subluteal levels, and follicular phase levels of the normal estrous cycle, respectively. The FSH pulse frequency was maintained highly in all groups on Day 0, Day 3 and Day 7. An FSH surge was induced in all 4 cases of the Non-P group. In the High P and Low P groups, the plasma concentrations of FSH remained low until 48 h after the start of estradiol infusion, and no occurrence of FSH surge was found in any of the animals. The results of this study not only confirm that the pulsatile patterns of FSH were not inhibited strongly relative to LH, they also suggest that some other mechanism and factor may be controlling the FSH secretion.

Comparison of Patency and Viability in Fresh and Cryopreserved Arterial and Venous Allograft Conduits in Dogs (개에서 동맥과 정맥 동종 이식편의 냉장, 보존 방법에 따른 개존율 및 생육성에 관한 연구)

  • Song, Hyun;Kang, Shin-Kwang;Ryu, Yang-Gi;Kim, Yong-Jin
    • Journal of Chest Surgery
    • /
    • v.41 no.2
    • /
    • pp.149-159
    • /
    • 2008
  • Background: With increasing coronary bypass and peripheral vascular surgeries, the demand for homologous vascular or synthetic conduits has continued to grow, but wide-spread application has been limited by dismal patency rates. Although cryopreserved allograft valves may provide a suitable alternative, current viability or patency of implanted allograft vascular conduits has been unsatisfactory. Material and Method: We serially analyzed the outcomes of canine femoral artery and saphenous vein allograft implants after storage in either $4^{\circ}C\;or\;-170^{\circ}C$. Result: There were no differences in graft flow rate (patency) (p=0.264), rate of thrombosis (p=0.264), presence of endothelium (p=0.587), or immunohistochemical staining for thrombomodulin (p=0.657) were detected between grafts stored in $4^{\circ}C\;and\;-170^{\circ}C$. Greater flow occurred in the arterial grafts versus the venous grafts (p=0.030), irrespective of the preservation method, with a significantly lower incidence of thrombosis (p=0.030) in arterial allografts. There was a correlation coefficient of -0.654 between thrombosis and positive immunohistochemical staining for thrombomodulin (p=0.006) and a correlation coefficient of 0.520 (p=0.0049) between the endothelial presence and positive immunohistochemical staining for thrombomodulin. The relationship between the presence of endothelium and thrombomodulin expression failed to show any correlation within the first 2 weeks (p=0.306). However, a strong correlation was seen after 1 month (p=0.0008). Conclusion: Tissue storage in either $4^{\circ}C\;or\;-170^{\circ}C$ in 10% DMSO/RPMI-1640 preservation solution preserved grafts equally well. In terms of thrombosis and graft patency, arterial grafts were superior to venous grafts. Considering the poor correlation between thrombomodulin expression and the presence of an endothelium in the implanted graft within the first two weeks, grafts in this period would not be thromboresistant.

Effects of Gonadal Steroid Hormones on Growth Efficiency, Carcass Characteristics and Circulating Concentrations of Insulin-like Growth Factor(IGF)-I and LGF-binding Protein-3 in Finishing Barrows (거세비육돈에서 성선스테로이드호르몬이 성장효율, 도체 특성 및 혈중 Insulin-like Growth Factor(IGF)-I 및 IGF-Binding Protein-3 농도에 미치는 영향)

  • Lee C.Y.;Ha S.H.;Lee H.P.;Baik K.H.;Jin S.K.;Sohn S.H.;Park M.J.
    • Proceedings of the KSAR Conference
    • /
    • 2005.06a
    • /
    • pp.47-54
    • /
    • 2005
  • In boars, unlike the cases in males of other species, gonadal hormones suppress voluntary feed intake. for this reason, barrows, compared with gilts or boars, eat too much feed resulting in excessive fat deposition. Two experiments were performed in the present study to investigate the effects of implantation of Revalor H[Experiment(Exp.) I: 140mg trenbolone acetate(a synthetic androgen) + 14mg estradiol-$17\beta(E_{2}\beta)$] and Compudose(Exp. II; 24mg $E_{2}\beta$) on growth efficiency, carcass characteristics and circulating concentrations of IGF-I and IGF-binding protein-3(IGFBP-3). In Exp. I, sixty-four cross-bred finishing barrows weighing approximately 60kg were randomly divided into eight pens under a 2[control vs Revalor implant] $\times$ 2(ad libitum vs $80\%$ ad libitum feeding) $\times$2[control($103\%$ NRC-recommended level) vs low-energy($87\%$ NRC recommendation) diet] arrangement of treatments. In Exp. II, effects of Compudose were studied using 80 finishing barrows(10 animals/pen). In both Exps., all the animals were slaughtered at 100- to 110-kg body weight. Both Revalor and Compudose implants caused a decrease in feed intake and backfat thickness without affecting major physicochemical characteristics of the carcass and an increase in circulating IGF-I concentration. Moreover, Revalor implant exhibited greater effects than restricted feeding, low-energy diet, or Compudose in these variables. In addition, Revalor implantation suppressed weight gain, but enhanced the feed efficiency without exhibiting any interaction with the diet or feeding. In summary, results suggest that 1) both androgen and estrogen suppress voluntary feed intake and backfat deposition and enhance IGF-I secretion and 2) these effects of the gonadal steroid hormones in growth are likely to be mediated, in part, by IGF-I in finishing barrows.

  • PDF

Axial wall thickness of zirconia abutment in anterior region (전치부 지르코니아 지대주의 축벽 두께)

  • Moon, Seung-Jin;Heo, Yu-Ri;Lee, Gyeong-Je;Kim, Hee-Jung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.53 no.4
    • /
    • pp.345-351
    • /
    • 2015
  • Purpose: The purpose of this study was to evaluate the proper axial thickness of zirconia abutment applied to implant in the anterior region. Materials and methods: Zirconia abutments were prepared at different axial wall thickness by processing pre-sintered zirconia blocks via CAD/CAM to obtain equal specimens. The abutments were each produced with a thickness of 0.5 mm (Group 1), 0.8 mm (Group 2), 1.2 mm (Group 3), or 1.5 mm (Group 4). The implant used in this study was a external connection type one (US, Osstem, Pussan, Korea) product and the zirconia abutment was prepared via replication of a cemented abutment. The crowns were prepared via CAM/CAM with a thickness of 1.5 mm and were cemented to the abutments using $RelyX^{TM}$ UniCem cement. A universal testing machine was used to apply load at 30 degrees and measure fracture strength of the zirconia abutment. Results: Fracture strength of the abutments for Group 1, Group 2, Group 3, and Group 4 were $236.00{\pm}67.55N$, $599.00{\pm}15.80N$, $588.20{\pm}33.18N$, and $97.83{\pm}98.13N$, respectively. Group 1 showed a significantly lower value, as compared to the other groups (independent Mann-Whitney U-test. P<.05). No significant differences were detected among Group 2, Group 3, and Group 4 (independent Mann-Whitney U-test. P>.05). Conclusion: Zirconia abutment requires optimal thickness for fracture resistance. Within the limitation of this study, > 0.8 mm thickness is recommended for zirconia abutment in anterior implants.

Effect of various abutment systems on the removal torque and the abutment settling in the conical connection implant systems (원추형 연결 임플란트에서 지대주 종류에 따른 나사풀림과 침하현상에 관한 연구)

  • Lee, Jin-Seon;Lee, Joon-Seok
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.50 no.2
    • /
    • pp.92-98
    • /
    • 2012
  • Purpose: The aim of this study was to evaluate the effects of different abutment materials on abutment screw loosening and settling-down effect in conical connection type implant system. Materials and methods: Three types of abutment, cementation, gold UCLA, and metal UCLA abutment were used. Two UCLA groups were fabricated in a similar pattern to cementation abutment. Type III gold alloy and Nickel-Chromium alloy was used for casting gold UCLA abutment and metal UCLA abutment, respectively. Fixture and abutment were tightened to 30 Ncm by using digital torque controller and re-tightening was conducted with same force after 10 minutes. Digital torque gauge was used to measure loosening torque and fixture/abutment length was measured by digital micrometer. Dynamic loads between 25 N and 250 N were applied with $0^{\circ}$ angle to the abutment axis. After loading, fixture/abutment length was re-measured and amount of settlement was calculated. Loosening torque value was also measured for comparison Results: All three groups showed significant differences of length when comparing before and after loading, but there was no significant difference of settling amount in all groups. Loosening torque values were significantly decreased when comparing before and after loading in all groups($P$<.05). However, there was no significant difference in loss of loosening torque values when compared to groups. Conclusion: In internal conical connection type implants, dynamic load affected on settlement and loosening torque of implant, but there was no differences between abutments materials. Likewise gold UCLA abutment, metal UCLA abutment might be able to withstand functional load.

Evaluation of reverse torque value of abutment screws on CAD/CAM custom-made implant abutments (CAD/CAM을 이용한 맞춤형 임플란트 지대주의 나사 풀림 토크 평가)

  • Lee, Chang-Jae;Yang, Sung-Eun;Kim, Seok-Gyu
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.50 no.2
    • /
    • pp.128-134
    • /
    • 2012
  • Purpose: The purpose of this study was to compare the screw joint stability between the CADCAM custom-made implant abutment and the prefabricated implant abutment by measuring the reverse torque value after cyclic loading. Materials and methods: Twelve screw type implants (Implantium, Dentium Co., Seoul, Korea) were embedded in aluminum cylinder with acrylic resin. The implant specimens were equally divided into 3 groups, and connected to the prefabricated titanium abutments (Implantium, Dentium Co., Seoul, Korea), CADCAM custom-made titanium abutments (Myplant, Raphabio Co., Seoul, Korea) and CADCAM custom-made zirconia abutments (Zirconia Myplant, Raphabio Co., Seoul, Korea). The CAD-CAM milled titanium crown (Raphabio Co., Seoul, Korea) was cemented on each implant abutment by resin cement. Before cyclic loading, each abutment screw was tightened to 30 Ncm and the reverse torque value was measured about 30 minutes later. After the crown specimen was subjected to the sinusoidal cyclic loading (30 to 120 N, 500,000 cycles, 2 Hz), postloading reverse torque value was measured and the reverse torque loss ratio was calculated. Kruskal-Wallis test was used for statistical analysis of the reverse torque loss ratio. Results: The CADCAM custom-made titanium abutments presented higher values in reverse torque loss ratio without statistically significant differences than the prefabricated titanium abutments ($P$>.05). Reverse torque loss ratio of the custom-made zirconia abutments was significantly higher compared to that of the prefabricated titanium abutments ($P$=.014). Conclusion: Within the limitation of the present $in-vitro$ study, it was concluded that there was no significant difference in screw joint stability between the CADCAM custom-made titanium abutments and the prefabricated titanium abutments. On the other hand, the CADCAM custom-made zirconia abutments showed lower screw joint stability than prefabricated titanium abutments.

Retention of CAD/CAM Metal Copings Cemented on Short Titanium Abutments with Different Cements (짧은 티타늄 지대주에 합착된 CAD/CAM 금속 코핑의 시멘트 종류에 따른 유지력 비교)

  • Kim, Hyo-Jung;Song, Eun-Young;Yoon, Ji-Young;Lee, Si-Ho;Lee, Yong-Keun;Oh, Nam-Sik
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.28 no.2
    • /
    • pp.119-126
    • /
    • 2012
  • State of problem: Cement-retained implant-supported prostheses are routinely used in dentistry. The use of high strength cements has become more popular with the increasing confidence in the stability of the implant-abutment screw connection and the high survival rates of osseointegrated implants. No clinical data on retention of metal copings using CAD/CAM. To evaluate retention of metal copings using CAD/CAM system bonded to short titanium abutment with four different cements and compare retentive strength of metal copings with sandblasting or without sandblasting before cementation. Forty titanium abutment blocks were fabricated and divided into 4 groups of 10 samples each. Forty metal copings with occlusal hole to allow for retention testing were fabricated using CAD/CAM technology. The four cements were Fujicem(Fuji, Japan), Maxcem Elite(Kerr, USA), Panavia F2.0(Kurarary, Japan) and Superbond C&B(Sunmedical, Japan). The copings were cemented on the titanium abutment according to manufacture's recommendation. All samples were stored for 24h at 37oC in 100% humidity and tested for retention using universal testing machine(Instron) at a crosshead speed of 1.0mm/min. Force at retentive failure was recorded in Newton. The mode of failure was also recorded. Means and standard deviations of loads at failure were analyzed using ANOVA and Paired t-test. Statistical significance was set at P<0.05. Panavia F2.0 provided significantly higher retentive strength than Fujicem, Maxcem Elite(P<0.05). Sandblasting significantly increased bond strength(P<0.05). The mode of failure was cement remaining principally on metal copings. Within the limitation of this study, Panavia F2.0 showed significantly stronger retentive strength than Fujicem, Maxcem Elite(p<0.05). The Ranking order of the cements to retain the copings was Panavia F2.0, Fujicem = Maxcem Elite. Sandblasting significantly increased bond strength(P<0.05). The retentive strength of metal copings on implant abutment were influenced by surface roughness and type of cements.

Three dimensional analysis of tooth movement using different sizes of NiTi wire on NiTi scissors-bite corrector (NiTi scissors-bite corrector의 와이어 굵기에 따른 3차원적 치아 이동 양상)

  • Jeon, Hyun-Ju;Park, Sun-Hyung;Jung, Sang-Hyuk;Chun, Youn-Sic
    • The korean journal of orthodontics
    • /
    • v.39 no.1
    • /
    • pp.43-53
    • /
    • 2009
  • Objective: The purpose of this study was to compare the difference in three dimensional tooth movement using three different wire sizes($0.018{\times}0.025-in,\;0.016{\times}0.022-in$ 0.016-in) on a NiTi scissors-bite corrector. Methods: Computed tomography(CT) images of the experimental model before and after tooth movement were taken and reconstructed into three dimensional models for superimposition. The direction and the amount of tooth movement were measured and analyzed statistically. Results: The lingual and intrusive movements of the crown of the maxillary second molar were increased as the size of the NiTi wire increased. The roots of the maxillary second metals moved buccally except for the 0.016-in group. The intrusive movement of the roots of the maxillary second molars was increased as the size of the NiTi wire increased. Due to the use of orthodontic mini-implants, anchorage loss was under 0.2 mm on average. Conclusions: The $0.018{\times}0.025-in$ NiTi wire was most effective in lingual and intrusive movement of the maxillary second molar which was in scissors-bite position. Indirect skeletal anchorage with a single orthodontic mini-implant was rigid enough to prevent anchorage loss.