• Title/Summary/Keyword: Implant-supported fixed dental prosthesis

Search Result 95, Processing Time 0.027 seconds

Implant supported over denture with O-ring abutment (O-ring abutment를 이용한 Implant over denture의 제작)

  • Lee, Sung-Uck;Lee, Jung-Hwan;Park, Hyo-Ryun
    • Journal of Technologic Dentistry
    • /
    • v.26 no.1
    • /
    • pp.209-216
    • /
    • 2004
  • The purpose of this study is to introduce how to make implant supported over denture with Oring. Many kinds of attachments have used to dental restorations. The application of attachment has widely increased implant fixed prosthesis and implant supported over denture. In order that implant supported over denture have properly retention, generally used O-ring, magnetic, bar attachment. O-ring give us an advantage that is required more minimum vertical dimension than bar-type and easily replace with new part. When we make these prosthesis using O-ring, Bar, Ball attachment, we should following procedures. Strong occlusion force leads to fracture of over denture because part of functional mechanism as implant abutment or attachment is spaced. Clips are regularly activated. O-ring and springs are changed every year. The pattern of resorption should be carefully monitored and compensated for by relining procedures. If the over denture appears to rest on the bar or the ball attachments, relining should be performed and clips/caps should be changed.

  • PDF

Implant-supported overdenture manufactured using CAD/CAM techniques to achieve horizontal path insertion between the primary and secondary structure: A clinical case report

  • Agustin-Panadero, Ruben;Penarrocha-Oltra, David;Gomar-Vercher, Sonia;Ferreiroa, Alberto;Penarrocha-Diago, Miguel
    • The Journal of Advanced Prosthodontics
    • /
    • v.7 no.3
    • /
    • pp.264-270
    • /
    • 2015
  • This report describes the case of an edentulous patient with an atrophic maxilla and severe class III malocclusion. Prosthetic rehabilitation was performed using CAD/CAM techniques for manufacturing an implant-supported overdenture with horizontal insertion. A vestibulo-lingual insertion overdenture is a precision prosthesis with a fixation system affording a good fit between the primary and secondary structure. Both structures exhibit passive horizontal adjustment. This treatment option requires the same number of implants as implant-supported fixed dentures. The horizontal assembly system prevents the prosthesis from loosening or moving in response to axial and non-axial forces. The technique was used to rehabilitate a patient presenting an atrophic upper maxilla, with the insertion of 8 implants. No complications were reported at follow-up 3, 6 and 12 months after fitting of the prosthesis. This system offers solutions to the clinical and laboratory complications associated with hybrid prostheses, concealing emergence of the chimneys and improving implant-prosthesis hygiene.

Prosthetic misfit of implant-supported prosthesis obtained by an alternative section method

  • Tiossi, Rodrigo;Falcao-Filho, Hilmo Barreto Leite;De Aguiar, Fabio Afranio Junior;Rodrigues, Renata Cristina Silveira;De Mattos, Maria da Gloria Chiarello;Ribeiro, Ricardo Faria
    • The Journal of Advanced Prosthodontics
    • /
    • v.4 no.2
    • /
    • pp.89-92
    • /
    • 2012
  • PURPOSE. Adequate passive-fitting of one-piece cast 3-element implant-supported frameworks is hard to achieve. This short communication aims to present an alternative method for section of one-piece cast frameworks and for casting implant-supported frameworks. MATERIALS AND METHODS. Three-unit implant-supported nickel-chromium (Ni-Cr) frameworks were tested for vertical misfit (n = 6). The frameworks were cast as one-piece (Group A) and later transversally sectioned through a diagonal axis (Group B) and compared to frameworks that were cast diagonally separated (Group C). All separated frameworks were laser welded. Only one side of the frameworks was screwed. RESULTS. The results on the tightened side were significantly lower in Group C ($6.43{\pm}3.24{\mu}m$) when compared to Groups A ($16.50{\pm}7.55{\mu}m$) and B ($16.27{\pm}1.71{\mu}m$) ($P$ <.05). On the opposite side, the diagonal section of the one-piece castings for laser welding showed significant improvement in the levels of misfit of the frameworks (Group A, $58.66{\pm}14.30{\mu}m$; Group B, $39.48{\pm}12.03{\mu}m$; Group C, $23.13{\pm}8.24{\mu}m$) ($P$ <.05). CONCLUSION. Casting diagonally sectioned frameworks lowers the misfit levels. Lower misfit levels for the frameworks can be achieved by diagonally sectioning one-piece frameworks.

Reconstruction of Disharmonious Upper Anterior Dentition by Implant Supported Fixed Prosthesis (임플란트 지지 고정성 보철물로 상악 전치부를 수복한 증례)

  • Oh, Sang-Chun;Chee, Young-Deok
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.24 no.2
    • /
    • pp.183-192
    • /
    • 2008
  • Modern dental reconstructions do not only aim at restoring the patient's mastication, but rather at improving general well-being and quality of life, especially in terms of esthetics. The media, the internet, advertising, and many other facts of society contribute to an increased cosmetic awareness. A 35-year-old male patient presented with as follows: 1) the porcelain fracture of ceramo-metal restoration on #11 and #23, 2) the inclination of incisal plane to horizontal reference plane, 3) the dental midline deviation to facial midline, and 4) the lack of symmetry on upper anterior dentition. The patient requested an aesthetic improvement using fixed prosthodontics including implant-supported restorations. In the upper anterior region, one of the goals of the conventional as well as implant prosthesis is to achieve restorations with the dental attractiveness and beauty in the respect of dental, dentofacial, and facial compositions. This case report presents geometrically improvement of dental esthetics using conventional and implant prosthesis with soft and hard tissue augmentation.

Finite element analysis in static and dynamic behaviors of dental prosthesis

  • Djebbar, N.;Serier, B.;Bouiadjra, B. Bachir
    • Structural Engineering and Mechanics
    • /
    • v.55 no.1
    • /
    • pp.65-78
    • /
    • 2015
  • In recent years, implants have gained growing importance in all areas of medicine. The success of the treatment depends on many factors affecting the bone-implant, implant-abutment and abutment-prosthesis interfaces. In this paper, static and dynamic behaviors of the dental prosthesis are investigated. Three-dimensional finite element models of dental prosthesis were constructed. Dynamic loads in 5 sec applied on occlusal surface. Therefore, FEA was selected for use in this study to examine the effect of the static and dynamic loads on the stress distribution for an implant-supported fixed partial denture and supporting bone tissue.

Considerations for the Survival of Complete Arch Implant-Supported Zirconia Restorations; Status of Antagonistic Arches and Stress Distribution on Frameworks: A Case Report

  • Choi, Jung-Yoo;Sim, Jae-Hyuk;Yeo, In-Sung Luke
    • Journal of Korean Dental Science
    • /
    • v.10 no.2
    • /
    • pp.74-81
    • /
    • 2017
  • This report describes two cases of complete arch implant-supported restorations. The first patient had seven dental implants in each arch with monolithic zirconia frameworks. At four weeks' follow-up, the one-piece maxillary framework was fractured, which was re-designed and re-fabricated using laser-sintered cobalt-chrome alloy. The second patient had four implants in the mandible only. A mandibular monolithic zirconia framework and a maxillary conventional complete denture were fabricated and delivered. At five years' follow-up, the patient reported no significant discomfort. Careful consideration and monitoring of the status of antagonistic arches and stress distribution on zirconia frameworks were suggested for complete arch implant-supported fixed restorations.

Full mouth rehabilitation of mandibular edentulous patient using implant hybrid prosthesis (하악 무치악 환자에서 임플란트 하이브리드 보철물을 이용한 전악 수복 증례)

  • Kim, Seong-Bin;Kim, Sung-Hoi;Park, Young-Bum;Moon, Hong-Suk
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.51 no.3
    • /
    • pp.214-220
    • /
    • 2013
  • Implant prosthodontics is beneficial for edentulous patients in enhancing the support, retention, stability, phonation and so on. Various types of prosthesis supported by implant, including implant retained- or supported- overdenture for the removable type and ceramo-metal and fixed prostheses with processed acrylic teeth for the fixed type, are frequently used. Treatment planning for the prosthesis with implant must be made after considering individual characteristics such as form of residual ridge, soft tissue, interocclusal relationship, economic status. Fixed prosthesis with processed acrylic teeth (also known as 'implant hybrid prosthesis' or 'bone anchored bridge') has the advantages of both removable and fixed prosthesis such as proper soft tissue profile, esthetic outcome, increased masticatory efficiency and psychological stability. The 73-years-old female patient came to the department of prosthodontics, Dental hospital of Yonsei University. She was diagnosed with Kennedy class I partial edentulism in the maxilla and complete edentulism in the mandible. This article reports a satisfactory clinical and esthetic outcome of full mouth rehabilitation using removable partial denture in the maxilla and implant hybrid prosthesis in the mandible.

Maxillary implant-supported fixed prosthesis engaged by distal-extension removable partial denture for 10 years: a case report (상악의 임플란트 고정성 보철물과 후방연장 국소의치를 이용하여 수복한 10년 경과 관찰 증례)

  • Ryu, Ri;Park, Yeon-Hee;Oh, Won-suk;Lee, Jung-Jin;Park, Ju-mi
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.36 no.2
    • /
    • pp.121-127
    • /
    • 2020
  • Prosthodontic decision and management should be considered the patient's aesthetic need for anterior teeth in maxillary edentulism. This case report describes 10-year clinical outcome of a maxillary edentulous patient was rehabilitated by means of an implant-supported fixed dental prosthesis (ISFDP) for the anterior region and a distal-extension removable partial denture (RPD) for the posterior region. The ISFDP was designed to splint 4 endosseous implants as one unit and engaged by the RPD. The edentulous mandible was restored by means of an implant-supported overdenture. Over the course, no major adverse event occurred other than wear, discoloration, and breakage of resin veneers and artificial teeth.

Removable Partial Denture Using Anterior Implant-Supported Fixed Prostheses for Edentulous Patients: A Case Report

  • Lee, You-Jin;Bae, Eun-Bin;Jeong, Chang-Mo;Lee, Jin-Ju;Kim, Ji-Young;Huh, Jung-Bo
    • Journal of Korean Dental Science
    • /
    • v.10 no.2
    • /
    • pp.87-95
    • /
    • 2017
  • This case study was to report the possible increase in the denture retention and psychological relief using the implant-supported fixed prostheses in a completely edentulous patient. The implants were placed in the anterior portion of the mandible in a patient who had completely edentulous state following the extraction of residual abutment teeth, and consequently a distal extension removable partial denture was fabricated. The patient's adaptation and satisfaction to the new prosthesis was monitored and confirmed in terms of masticatory function and esthetics, by restoring the oral condition similar to initial status before the residual teeth extraction. After 6 months, radiographic examination confirmed that both the abutment teeth and the implants were stable and well maintained. Considering the relatively short clinical follow-up period, however, continuous long-term monitoring was required.

Full mouth rehabilitation with fixed implant-supported prosthesis using temporary denture and double digital scanning technique: a case report (임시 의치와 이중 디지털 스캐닝 기법을 활용한 전악 고정성 임플란트 수복 증례)

  • Seok-Hyun Shin;Chan-Ik Park;Se-Ha Kang;Ji-Eun Moon;Min-Seok Oh;Chul-Min Park;Woo-Jin Jeon;Seong-Gu Han;Sun-Jae Kim;Su-Jin Choi
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.61 no.3
    • /
    • pp.245-256
    • /
    • 2023
  • When restoring with a dental digital system for implant-supported prosthesis, a double digital scanning technique is required: an intraoral scan of the three-dimensional implant location and intraoral scan after placement of temporary denture or provisional prosthesis. During the intraoral scan, the use of scan body as a stable landmark can improve the accuracy of digital impression and simplify laboratory process. In this case, a full-digital system was used to plan and fabricate a custom abutment, provisional prosthesis, and definitive prosthesis. After implant placement, the scan area of the intraoral scan body connected with implant and the intraoral scan body marked on the inside of temporary denture were superimposed. Out of the superimposed files, a custom abutment and provisional prosthesis were fabricated which match the vertical dimension of temporary denture, and definitive prosthesis was fabricated based on provisional prosthesis. We report this case because result has been functionally and esthetically satisfactory by using vertical dimension and central relation set during the fabrication of temporary denture to the definitive prosthesis.