Evaluation of fitness in implant screw as tightening torque in dental laboratory (기공실에서의 임플란트 토크값에 따른 적합도 평가)

  • Song, Young-Gyun
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.31 no.4
    • /
    • pp.310-315
    • /
    • 2015
  • Purpose: The purpose of this study was to measure the tightening torque for dental implant in dental laboratory and to analyze of the effects of different tightening torque. Materials and Methods: The tightening torque for dental implant in dental laboratory were measured by digital torque gauge. The length of abutment and analog were measured as tightening torque of manufacturer's instructions and the measured value. And the data were statically analyzed. Results: The mean tightening torque of implant screw in dental laboratory was $1.563{\pm}0.332Ncm$. The external type implant system of total length were showing no significant differences but the internal type implant system had difference significant (P < 0.05) when compared with tightening torque. Conclusion: The implant prosthesis should be made under manufacturer's instructions especially as tightening torque of screw. For the fidelity of implant prosthesis, dental technician should learn how to use the torque gauge.

Stability of implant screw joint (임플란트 나사의 안정성)

  • Chung, Chae-Heon;Kwak, Jong-Ha;Jang, Doo-IK
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.19 no.2
    • /
    • pp.125-137
    • /
    • 2003
  • The use of screw-retaind prosthesis on an osseointegrated implant is a popular treatment modality offering relative ease in the removal of the restoration. One of the complications associated with this modality is the loosening of the abutment and coping screws. Loosening of the screws results in patient dissatisfaction, frustration to the dentist and, if left untreated, component fracture. There are several factors which contribute to the loosening of implant components which can be controlled by the restorative dentist and lab technician. This article offers pratical solutions to minimize this clinical problem and describes the factors involved in maintaining a stable screw joint assembly. To avoid joint failure, adherence to specific clinical, as well as mechanical, parameters is critical. With respect to hardware, optimal tolerance and fit, minimal rotational play, best physical properties, a predictable interface, and optimal torque application are mandatory. In the clinical arena, optimal implant distribution; load in line with implant axis; optimal number, diameter, and length of implants; elimination of cantilevers; optimal prosthesis fit; and occlusal load control are equally important.

Repairment of abutment and abutment screw fracture in implant prosthesis: A case report (지대주 혹은 지대주 나사 파절이 발생한 임플란트 보철물에서 효과적인 수리 방법)

  • Kim, Jae Hoon;Yoo, Jin Joo;Kim, Man Yong;Yoon, Joon-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.57 no.1
    • /
    • pp.37-41
    • /
    • 2019
  • Dental implants are an effective and predictable treatment for restoration of missing teeth. However, as the use of implants increases, complications are also increasing. The mechanical complications are not only highly frequent, but also increasing as life span of an implant increases, thus, solutions should be prepared. In this report, we will present a case dealing with abutment fracture and abutment screw fracture which are the most common mechanical complication of the implant, focusing on preserving and reusing existing components by reconstructing only the damaged parts.

Long-term cumulative survival and mechanical complications of single-tooth Ankylos Implants: focus on the abutment neck fractures

  • Shim, Hye Won;Yang, Byoung-Eun
    • The Journal of Advanced Prosthodontics
    • /
    • v.7 no.6
    • /
    • pp.423-430
    • /
    • 2015
  • PURPOSE. To evaluate the cumulative survival rate (CSR) and mechanical complications of single-tooth $Ankylos^{(R)}$ implants. MATERIALS AND METHODS. This was a retrospective clinical study that analyzed 450 single $Ankylos^{(R)}$ implants installed in 275 patients between December 2005 and December 2012. The main outcomes were survival results CSR and implant failure) and mechanical complications (screw loosening, fracture, and cumulative fracture rate [CFR]). The main outcomes were analyzed according to age, sex, implant length or diameter, bone graft, arch, and position. RESULTS. The 8-year CSR was 96.9%. Thirteen (2.9%) implants failed because of early osseointegration failure in 3, marginal bone loss in 6, and abutment fracture in 4. Screw loosening occurred in 10 implants (2.2%), and 10 abutment fractures occurred. All abutment fractures were located in the neck, and concurrent screw fractures were observed. The CSR and rate of screw loosening did not differ significantly according to factors. The CFR was higher in middle-aged patients (5.3% vs 0.0% in younger and older patients); for teeth in a molar position (5.8% vs 0.0% for premolar or 1.1% for anterior position); and for larger-diameter implants (4.5% for 4.5 mm and 6.7% for 5.5 mm diameter vs 0.5% for 3.5 mm diameter) (all P<.05). CONCLUSION. The $Ankylos^{(R)}$ implant is suitable for single-tooth restoration in Koreans. However, relatively frequent abutment fractures (2.2%) were observed and some fractures resulted in implant failures. Middle-aged patients, the molar position, and a large implant diameter were associated with a high incidence of abutment fracture.

Analysis of the Bone-remodeling Process Considering Stimuli Delivery Cell Model (자극전달세포 모델을 고려한 골 재형성 해석)

  • Moon Hee-Wook;Kim Young-Eun
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.23 no.6 s.183
    • /
    • pp.180-186
    • /
    • 2006
  • To investigate the bone remodeling phenomenon around implant device, 3-D mathematical simulation model was developed. Strain energy density from the finite element method was chosen for the indicator for remodeling process. Recursive calculations continued until converged results between FEM and mathematical model. For a osteo-integration example, bone-remodeling process in a implanted tibia of beagle was adapted. Calculated results indicated that the bone densities around screw pitch were increased which indicates firm fixations between the bone and implant. Screw design parameters have an influence on initial stability of the implant rather than remodeling process.

A STUDY ON FITNESS OF SEVERAL DOMESTIC IMPLANT FIXTURE AND ABUTMENT SCREWS (국내제작 임프란트 고정체와 지대주 유지나사의 적합도에 대한 주사전자현미경적 비교연구)

  • Park Young-Sun;Vang Mong-Sook;Lee Seok-Hyung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.42 no.1
    • /
    • pp.94-109
    • /
    • 2004
  • Statement of problem : Several domestic dental implants have been developed since dental treatment being implants are increasing and popularized. However, they have not been used in domestic market like imported goods. Material and methods : This study was carried out to compare domestic and imported implants in aspect of fitness, dental implant fixture and abutment screw using scanning electron microscope. All experiments were performed under dry condition. Results : 1. Only in aspect of relation of dental implant fkxture and abutment screw, except only one group with point contact, good fitness was existed. 2. Home products must presevere in their efforts, so as excellent to fit.

Energy-dispersive X-ray spectroscopic investigation of a fractured non-submerged dental implant associated with abutment fracture

  • Truc Thi Hoang Nguyen;Mi Young Eo;Kezia Rachellea Mustakim;Mi Hyun Seo;Hoon Myoung;Soung Min Kim
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.49 no.1
    • /
    • pp.43-48
    • /
    • 2023
  • The biocompatibility and durability of implant fixtures are major concerns for dentists and patients. Mechanical complications of the implant include abutment screw loosening, screw fracture, loss of implant prostheses, and implant fracture. This case report aims to describe management of a case of fixture damage that occurred after screw fracture in a tissue level, internal connection implant and microscopic evaluation of the fractured fixture. A trephine bur was used to remove the fixture, and the socket was grafted using allogeneic bone material. The failed implant was examined by scanning electron microscopy (SEM) and energy dispersive X-ray spectroscopy (EDS), which revealed a fractured fixture with both normal and irregular bone patterns. The SEM and EDS results give an enlightenment of the failed fixture surface micromorphology with microfracture and contaminated chemical compositions. Noticeably, the significantly high level of gold (Au) on the implant surface and the trace amounts of Au and titanium (Ti) in the bone tissue were recorded, which might have resulted from instability and micro-movement of the implant-abutment connection over an extended period of time. Further study with larger number of patient and different types of implants is needed for further conclusion.

RETROSPECTIVE MULTICENTER STUDY OF CSM ENDOSSEOUS DENTAL IMPLANT

  • Park, Eun-Young
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.45 no.3
    • /
    • pp.321-328
    • /
    • 2007
  • Statement of problem. To work the economic limitation of dental implant usage, some types of domestic implant have been developing. But, there have been seldom reported about the clinical success rate of them as yet. Purpose. The aim of this retrospective multicenter study was to evaluate the performance of CSM implants(CSM company, Daegu, Korea). Material and methods. Thirty-five patients were rehabilitated with 150 CSM implants in this multicenter study. Results. The success rate was 96.2%. CSM Titanium fixtures can obtain slightly higher success rate when a cover screw was not used for implant installation than when used. However it doesn't show significant difference(p=.7615, Fisher's Exact test). Conclusion. This multicenter retrospective study demonstrated the efficacy of the CSM implant in the treatment of variety of clinical manifestation of tooth loss. And it can be assumed that whether a cover screw is used or not should no influence on the osseointegration.