• Title/Summary/Keyword: Implant restorations

Search Result 159, Processing Time 0.023 seconds

Digital duplication of provisional prosthesis to fabricate definitive prosthesis for full mouth rehabilitation using double scan technique (잠정수복물의 최종수복물로의 디지털 복제를 통한 완전구강 회복 증례: Double scan technique)

  • Hong, Young-Tack;Koak, Jai-Young;Kim, Seong-Kyun;Heo, Seong-Joo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.59 no.1
    • /
    • pp.63-70
    • /
    • 2021
  • Using computer-aided design and manufacturing technique improve quality of treatment in many aspect. This case reports the complete mouth rehabilitation of a patient with amelogenesis imperfecta utilizing digital technology. Clinical examination revealed loss of mastication due to insufficient occlusal stop, missing teeth, interdental spacing due to microdontia, insufficient overbite, and etc. Full veneer crowns for teeth were selected, followed by a fixed partial denture and implant placement was done using CAD-CAM guide template with bone graft for partially edentulous space. Definitive restorations were duplicated by double scanning provisional restorations and successfully delivered to the patient. These full mouth rehabilitation procedures resulted in satisfactory outcomes for the patient functionally and aesthetically.

Implant success rates in full-arch rehabilitations supported by upright and tilted implants: a retrospective investigation with up to five years of follow-up

  • Francetti, Luca;Rodolfi, Andrea;Barbaro, Bruno;Taschieri, Silvio;Cavalli, Nicolo;Corbella, Stefano
    • Journal of Periodontal and Implant Science
    • /
    • v.45 no.6
    • /
    • pp.210-215
    • /
    • 2015
  • Purpose: The aim of this retrospective study was to investigate the cumulative success rate, the implant survival rate, and the occurrence of biological complications in implants supporting full-arch immediately loaded rehabilitations supported by upright and tilted implants. Methods: The clinical records and periapical radiographs of patients who attended follow-up visits were collected, and information was recorded regarding marginal bone loss resorption, the occurrence of peri-implant infectious diseases, and the implant survival rate. Implants were classified as successful or not successful according to two distinct classifications for implant success. Results: A total of 53 maxillary and mandibular restorations including 212 implants were analysed, of which 56 implants were studied over the full five-year follow-up period. After five years, the cumulative success rate was 76.04% according to the Misch classification and 56.34% according to the Albrektsson classification. The cumulative implant survival rate was 100%, although one implant was found to be affected by peri-implantitis at the second follow-up visit. Conclusions: The cumulative success rate of the implants dropped over time, corresponding to the progression of marginal bone resorption. The prevalence of peri-implantitis was very low, and the implant survival rate was not found to be related to the cumulative success rate.

Pontic site development with an implant submergence technique for unaesthetic implant in the anterior maxilla (상악 전치부 임플란트의 비심미성 개선을 위한 임플란트 침수(submergence)를 동반한 치조제 증대술)

  • Song, Yujeong;Lee, Ju-Youn
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.36 no.4
    • /
    • pp.289-295
    • /
    • 2020
  • Improving implant esthetics is very difficult, especially in cases where unaesthetic problems are related to implants in the maxillary anterior dentition. A 69-year old male patient was referred by a prosthodontist for periodic pus discharge and an unaesthetic implant prosthesis (maxillary right lateral incisor). The implant was placed too deeply and showed soft tissue volume deficiency and a long clinical crown. After a clinical and radiographic examination, implant submergence and alveolar ridge augmentation were performed to enhance the aesthetics instead of an explantation. The treatment plan was as follows: extraction the adjacent teeth with tooth mobility, secondary caries, and poor prognosis; placement an additional dental implant with hard and soft tissue grafting; fabrication a fixed bridge using implant abutments. A fixed esthetic prosthesis using implants was fabricated, and the patient was satisfied with the prosthesis. A ridge augmentation with implant submergence may be an alternative for solving the problems of unaesthetic implant restorations in the esthetic zone.

IN VITRO STUDY OF THE TENSILE BOND STRENGTH OF CEMENT-RETAINED SINGLE IMPLANT PROSTHESIS BY THE VARIOUS PROVISIONAL LUTING CEMENTS AND THE SURFACE TREATMENT OF ABUTMENTS

  • Lee, Hwa-Yeon;Lee, Ho-Sang
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.40 no.3
    • /
    • pp.296-305
    • /
    • 2002
  • The main disadvantage of cement-retained implant restorations is their difficulty in retrievability. Advocates of cemented implant restorations frequently state that retrievability of the restoration can be maintained if a provisional cement is used. The purpose of this study was to find the optimal properties of provisional luting cements and the surface treatment of abutments in single implant abutment system. 30 prefabricated implant abutments, height 8mm, diameter 6mm, 3-degree taper per side, with light chamfer margins were obtained. Three commercially available provisional luting agents which were all zinc oxide eugenol type ; Cavitec, TempBond and TempBond NE were evaluated. No cement served as the control. TempBond along with vaseline, a kind of petrolatum (2:1 ratio) was also evaluated. Ten out of thirty abutments were randomly selected and abutment surfaces were sandblasted with $50{\mu}m$ aluminum oxide. Another ten abutments were sandblasted with $250{\mu}m$ aluminum oxide. A vertical groove, 1 mm deep and 5mm long was cut in each twenty abutments. Ten of them were sandblasted with $50{\mu}m$ aluminum oxide. The full coverage casting crowns were cemented to the abutments with the designated provisional luting agent. Specimens were stored in distilled water at $37^{\circ}C$ for 24 hours. Each specimen was attached to a universal testing machine. A crosshead speed of 0.5mm/min was used to apply a tensile force to each specimen. Within the limitations of this in vitro study, the following conclusions were drawn: 1. Tensile bond strength of provisional luting cements in no surface treatment decreased with the sequence of TempBond NE, TempBond, Cavitec, TempBond with vaseline, no cement. 2. Tensile bond strength more increased by surface treatment. Sandblasting with $250{\mu}m$ aluminum oxide exhibited the highest tensile bond strength in the abutment cemented with TempBond NE and sandblasting with $50{\mu}m$ aluminum oxide exhibited the highest tensile bond strength in cemented with TempBond. 3. In the aspect of a groove formation, tensile bond strength significantly increased in TempBond with vaseline only and the others had no significant effect on tensile bond strength.

Accuracy of computer-aided template-guided oral implant placement: a prospective clinical study

  • Beretta, Mario;Poli, Pier Paolo;Maiorana, Carlo
    • Journal of Periodontal and Implant Science
    • /
    • v.44 no.4
    • /
    • pp.184-193
    • /
    • 2014
  • Purpose: The aim of the present study was to evaluate the in vivo accuracy of flapless, computer-aided implant placement by comparing the three-dimensional (3D) position of planned and placed implants through an analysis of linear and angular deviations. Methods: Implant position was virtually planned using 3D planning software based on the functional and aesthetic requirements of the final restorations. Computer-aided design/computer-assisted manufacture technology was used to transfer the virtual plan to the surgical environment. The 3D position of the planned and placed implants, in terms of the linear deviations of the implant head and apex and the angular deviations of the implant axis, was compared by overlapping the pre- and postoperative computed tomography scans using dedicated software. Results: The comparison of 14 implants showed a mean linear deviation of the implant head of 0.56 mm (standard deviation [SD], 0.23), a mean linear deviation of the implant apex of 0.64 mm (SD, 0.29), and a mean angular deviation of the long axis of $2.42^{\circ}$ (SD, 1.02). Conclusions: In the present study, computer-aided flapless implant surgery seemed to provide several advantages to the clinicians as compared to the standard procedure; however, linear and angular deviations are to be expected. Therefore, accurate presurgical planning taking into account anatomical limitations and prosthetic demands is mandatory to ensure a predictable treatment, without incurring possible intra- and postoperative complications.

Full mouth rehabilitation utilizing computer guided implant surgery and CAD/CAM (Computer guided implant surgery와 CAD/CAM을 활용한 전악 수복 증례)

  • Kim, Sungjin;Han, Jung-Suk;Kim, Sung-Hun;Yoon, Hyung-In;Yeo, In-Sung Luke
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.57 no.1
    • /
    • pp.57-65
    • /
    • 2019
  • Computer aided design and manufacturing and implant surgery using a guide template improve restoration-driven implant treatment procedures. This case utilized those digital technologies to make definitive prostheses for a patient. According to the work flow of digital dentistry, cone beam computed tomography established the treatment plan, which was followed to make the guide template for implant placement. The template guided the implants to be installed as planned. The customized abutments and surveyed fixed restorations were digitally designed and made. The metal framework of the removable partial denture was cast from resin pattern using an additive manufacturing technique, and the artificial resin teeth were replaced with the zirconia onlays for occlusal stability. These full mouth rehabilitation procedures provided functionally and aesthetically satisfactory results for the patient.

Comparison of the torque stability of Implant Torque Controllers

  • Kim, Dae-Gon;Cho, Lee-Ra;Park, Chan-Jin
    • Journal of Korean Dental Science
    • /
    • v.2 no.1
    • /
    • pp.19-27
    • /
    • 2009
  • Tightening of the screws in implant restorations should be accurate and precise. If applied torque is too low, screw loosening would be occurred. With too high torque, the screw fracture might take place. Various torque generating devices are developed and employed to apply a proper torque. The purpose of this investigation was to determine and compare the accuracy of the torque controllers. In this study, 4 types of torque controllers were used; electronic torque controller, torque limiting device, torque indicating device and contra angle torque driver. Digital torque gauge was employed to measure the de-torque value. Thirty cycles of tightening and loosening were done with each torque controller. All implant torque controllers have shown slight errors and deviations. The torque liming device exhibited the most accurate data. No significant difference was found among the mean de-torque values of the electronic torque controller, torque indicating device and contra angle torque driver. In the limitation of this study, it would be recommended that the implant torque controllers should be checked whether uniformed and precise torque can be generated and a measuring error should be corrected.

  • PDF

Consideration on the esthetic problems from implant cases (임플란트 증례에서 발생하는 심미적 문제점들에 관한 고찰)

  • Lee, Dong-Hyun
    • Journal of the Korean Academy of Esthetic Dentistry
    • /
    • v.24 no.1
    • /
    • pp.39-48
    • /
    • 2015
  • The critical factors affecting the esthetics of anterior implants can be summarized as following: 1) Correct positioning of implant fixture, 2) Enough amount of alveolar bone, 3) Optimum volume of soft tissue. The position of implant is probably the most important factor in obtaining esthetic treatment outcome. The 3-dimensional orientation of implant is determined by the position on the alveolar ridge and its direction. Clinicians often try to mimic natural teeth when fabricating restorations. During the course of esthetic diagnosis and treatment, however, one should not forget to consider the correlation between facial pattern, lips, gingiva, alveolar ridge, as well as remaining dentition. Since anterior region is biologically unfavorable when compared with posterior region, one minor discrepancy in positioning of implant can cause esthetically undesirable treatment outcome. If one understands the biological and prosthetic meaning of implant' s 3-dimensional position, he or she can achieve superior esthetic outcome in anterior region.

Study on osseointegration of a Korean Transitional implant system in beagle dog (성견에서 국산 임시 임플란트의 골 유착반응에 관한 연구)

  • Lee, Wook-Jae;Jung, Jong-Won;Kim, Yun-Sang;Pi, Sung-Hee;You, Hyung-Keun;Shin, Hyung-Shik
    • Journal of Periodontal and Implant Science
    • /
    • v.36 no.1
    • /
    • pp.253-263
    • /
    • 2006
  • Purpose: Recently, dental implant systems have been widely used for the treatment of the extraction site, but we have been confronted with many limitations in esthetics, phonetics and function. Transitional implants(TI) were developed as a method of providing fixed provisional restorations during conventional implant healing. Until now, little data have been provided on korean transitional implants. The purpose of this study is to evaluate the implant placement site histologically after 4 weeks and 8 weeks. Materials and Methods : Test group( IntermetzzoTM MEGAGEN, KOREA) and control group(Mini Drive Lock, Intra Rock, U.S.A.) were immediately placed in interseptal or interproximal bone of beagle dog after mandibular premolars extraction, and had a healing period with non-submerged state but without loading, Both TI surfaces were composed of rough surfaces. Results: In the test group, the average percentage of BIC were respectively 39.40%(SD7.35) after 4 weeks and 44.05%(16.76) after 8 weeks, and In the control group were 50.75%(1.48) and 59.40%(0.00). Discussion: We evaluated the initial ability of the osseointegration of TI through this study. Because TI is placed with a conventional implant simultaneously and loaded immediately, the ability of osseointegration is a very important factor for the success of TI during the initial healing phase. Conclusion: The results of the histological evaluation of these two groups were similar to those mentioned in other studies for osseointegration of implant.

Technical complications of cement-retained implant-supported single crowns and splinted crowns with zirconia frameworks (지르코니아 프레임워크를 이용한 시멘트 유지형 임플란트-지지 단일 크라운과 연결 크라운의 보철적 합병증)

  • You, Sang-Choon;Bae, Jung-Yoon
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.55 no.1
    • /
    • pp.26-31
    • /
    • 2017
  • Purpose: This study was to assess clinically the success rates and technical complications of cement-retained implant-supported single crowns and splinted crowns with zirconia frameworks. Materials and methods: 75 (single crowns: 51, splinted crowns: 24) cement-retained implant-supported single crowns and splinted crowns with zirconia frameworks which were restored in 67 patients were investigated for the evaluation of the success rates and technical complications. All restorations were cemented with temporary cement. Age, gender, restoration position, opposing teeth, restoration type were assessed as possible factors affecting technical complications. Results: During the mean observation period of 22.2 months, cumulative success rates of all restorations were 66.9 (73.2 - 60.6)%. Retention loss was found in 16 restorations (single crowns: 14, splinted crowns: 2), abutment screw loosening and veneer porcelain fracture were found in each 2 single crowns, respectively. According to a Kaplan-Meier survival analysis of single crowns and splinted crowns, the cumulative success rates were 58.9 (66.6 - 51.2)%, 87.5 (96.1 - 78.9)%, respectively. There was a statistically significant difference. The other possible factors did not have a significant effect on the technical complications. Conclusion: Retention loss was the most frequent technical complication. Abutment screw loosening and veneer porcelain fracture were found rarely in single crowns only. Age, gender, restoration position, and antagonist did not have significant effect on the technical complications. Splinted crowns had a higher success rate than single crowns.