• 제목/요약/키워드: Implant fracture

검색결과 318건 처리시간 0.027초

Biomechanical Comparative Study for Osteosynthesis of Pauwels Type III Femoral Neck Fractures: Conventional Devices versus Novel Fixed Angle Devices

  • Dae-Hyun Park;Young-Chae Seo;Yong-Uk Kwon;Soo-Hwan Jung;Seung-Jin Yoo
    • Hip & pelvis
    • /
    • 제34권1호
    • /
    • pp.35-44
    • /
    • 2022
  • Purpose: Osteosynthesis has been recommended for treatment of Pauwels type III femoral neck fractures in young patients. However, no implant of choice has been reported so far. This study was conducted in order to compare the fixation stability of two conventional fixation methods with three different novel fixed angle devices in this type of fracture. Materials and Methods: A total of 25 composite femurs (4th Generation Saw bone; Pacific Research Laboratories, USA) corresponding to human bone were used. Pauwels type III fracture type was uniformly reproduced. Specimens were fixed with a cannulated screw, cannulated screw with cable, and Intertan nail, dynamic hip screw, and IKEY nail. Measurement of failure loads and the rotational change of the femoral head fragment was performed for evaluation of fixation stability. Results: All implants were compared with cannulated screw and dynmaic hip screw. No meaningful improvement was observed for the cannulated screw with cable compared with the cannulated screw and dynamic hip screw. Meaningful improvement in load-to-failure and y-rotation and z-rotation was observed for both the Intertan nail and IKEY nail compared with the cannulated screw. However, compared with the dynamic hip screw, only the IKEY nail showed improvement in the same profile but the Intertan nail did not. Conclusion: Among novel fixed angle devices, meaningful improvement was observed for the IKEY nail compared with conventional implants. Strengths of this implant include biomechanical stability and simplicity of surgical technique, indicating that it may be another good option for osteosynthesis of Pauwels type III femoral neck fractures.

임플란트와 상부구조물 사이의 micromotion에 관한 연구 (A study on the micromotion between the dental implant and superstructure)

  • 김지혜;송광엽;장태엽;박주미
    • 구강회복응용과학지
    • /
    • 제19권1호
    • /
    • pp.17-25
    • /
    • 2003
  • Treatment with implants of single tooth missing cases is both functional and esthetic. Although the success rate of single-tooth implant treatments is increasing, sometimes it makes some problems. Problems with single-tooth implant treatments include soft tissue complications, abutment screw fracture, and most commonly, abutment screw loosening, and these involve the instability of the dental implant-superstructure interface. This study investigated and compared dental implant screw joint micromotion of various implant system with external connection or internal connection when tested under simulated clinical loading, Six groups (N=5) were assessed: (1) Branemark AurAdapt (Nobel Biocare, Goteborg, Sweden), (2) Branemark EsthetiCone (Nobel Biocare, Goteborg, Sweden), (3) Neoplant Conical (Neobiotec, Korea), (4) Neoplant UCLA (Neobiotec, Korea), (5) Neoplant 5.5mm Solid (Neobiotec, Korea), and (6) ITI SynOcta (Institute Straumann, Waldenburg, Switzerland). Six identical frameworks were fabricated. Abutment screws were tightened to 32-35 Ncm and occlusal screw were tightened to 15-20 Ncm with an electronic torque controller. A mechanical testing machine applied a compressive cyclic load of 20kg at 10Hz to a contact point on each implant crown. Strain gauge recorded the micromotion of the screw joint interface once a second. Data were selected at 1, 500, 5,000, 10,000, 20,000, 30,000, 40,000 and 50,000 cycle and 2-way ANOVA test was performed to assess the statistical significance. The results of this study were as follows; The micromotion of the implant-superstructure in the interface increased gradually through 50,000 cycles for all implant systems. In the case of the micromotion according to cycle increase, Neoplant Conical and Neoplant UCLA system exhibited significantly increasing micromotion at the implant-superstructure interface (p<0.05), but others not significant. In the case of the micromotion of the implant-superstructure interface at 50,000 cycle, the largest micromotion were recorded in the Branemark EsthetiCone, sequently followed by Neoplant Conical, Neoplant UCLA, Branemark AurAdapt, ITI SynOcta and Neplant Solid. Internal connection system showed smaller micromotion than external connection system. Specially, Neoplant Solid with internal connection system exhibited significantly smaller micromotion than other implant systems except ITI SynOcta with same internal connection system (p<0.05). In the case of external connection, Branemark EsthetiCone and Neoplant Conical system with abutment showed significantly larger micromotion than Branemark AurAdapt without abutment (p<0.05).

치은연하 파절로 치조골 소실을 동반한 상악측절치에서 orthodontic extrusive remodeling후 임플란트 식립을 통한 심미수복: 증례보고 (ANTERIOR ESTHETIC IMPROVEMENT THROUGH ORTHODONTIC EXTRUSIVE REMODELING AND SINGLE-UNIT IMPLANTATION IN A FRACTURED UPPER LATERAL INCISOR WITH ALVEOLAR BONE LOSS: A CASE REPORT)

  • 황수연;손원준;한영철;배광식;백승호;이우철;금기연
    • Restorative Dentistry and Endodontics
    • /
    • 제33권1호
    • /
    • pp.39-44
    • /
    • 2008
  • 심미적으로 중요한 전치부에서 단일치아 임플란트를 이용한 보철수복은 임상의에게 새로운 도전과제중의 하나가 되었다. 그러나 전치부에서 single-unit implant는 식립할 부위의 치조골 상태가 양호해야 하는데 치은연하 파절로 인해 치아 주위에 골 손실이 있는 경우 immediate implant는 심미적으로 문제를 야기 할 수 있다. 따라서 본 증례는 "orthodontic extrusive remodeling"을 통해 파절치와 주위 조직을 교정적으로 정출시켜 임플란트 식립을 위한 연조직과 경조직을 증대시킨 후 임플란트 식립을 통해 상악측절치에서 성공적 인 심미수복을 이룬 증례에 관한 것이다.

치근파절로 변위된 상악 중절치의 디지털을 이용한 즉시 임플란트 식립 및 심미 수복 증례 (Digital immediate implantation and aesthetic immediate loading on maxillary incisor displaced due to root fracture: a case report)

  • 송지은;박송이;박찬;윤귀덕;임현필;박상원
    • 구강회복응용과학지
    • /
    • 제39권4호
    • /
    • pp.267-275
    • /
    • 2023
  • 디지털 자료를 이용한 진단 및 즉시 임플란트 식립, 그리고 보철 수복 방법은 전통적인 방법에 비하여 비교적 간단한 자료 채득을 통해 치료 과정을 간소화하고 정확도를 개선하며 데이터의 다양한 활용이 가능하다는 장점이 있다. 임플란트 즉시 식립 시 더 나은 심미적 결과를 얻기 위해서는 발치와의 치유 중에 임플란트 주변 연조직을 개선해야 한다. 이를 위하여 임시 보철물의 즉시 수복을 통해 출현윤곽의 형태를 적절하게 유도할 수 있으며, 향후 최종 수복시에 좋은 임상결과를 얻을 수 있어 환자 만족도가 높다. 본 증례는 상악 좌우 중절치에 외상 후 수평 치근파절이 발생함에 따라 심미성과 치조골 상태를 고려한 발치 후 임플란트 즉시 식립 및 부하를 계획하였다. 디지털 구강 스캐너를 이용한 인상 채득을 통해 외상 치아에 외력을 가하지 않으면서 보다 심미적인 보철물의 제작을 위한 디지털 진단 왁스업을 시행하였으며, 이를 토대로 이상적인 식립 위치를 결정하고 3D 프린팅 수술용 가이드를 이용한 임플란트 즉시 식립을 시행하였다. 식립 5일 후 임시 보철물을 수복하였으며, 3개월 동안 임시 보철물의 형태를 이용한 연조직 개선 및 형태 유도 과정을 거쳐 최종 지르코니아 보철물 수복하였다.

Long-term clinical and experimental/surface analytical studies of carbon/carbon maxillofacial implants

  • Szabo, Gyorgy;Barabas, Jozsef;Bogdan, Sandor;Nemeth, Zsolt;Sebok, Bela;Kiss, Gabor
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제37권
    • /
    • pp.34.1-34.14
    • /
    • 2015
  • Background: Over the past 30-40 years, various carbon implant materials have become more interesting, because they are well accepted by the biological environment. The traditional carbon-based polymers give rise to many complications. The polymer complication may be eliminated through carbon fibres bound by pyrocarbon (carbon/carbon). The aim of this study is to present the long-term clinical results of carbon/carbon implants, and the results of the scanning electron microscope and energy dispersive spectrometer investigation of an implant retrieved from the human body after 8 years. Methods: Mandibular reconstruction (8-10 years ago) was performed with pure (99.99 %) carbon implants in 16 patients (10 malignant tumours, 4 large cystic lesions and 2 augmentative processes). The long-term effect of the human body on the carbon/carbon implant was investigated by comparing the structure, the surface morphology and the composition of an implant retrieved after 8 years to a sterilized, but not implanted one. Results: Of the 16 patients, the implants had to be removed earlier in 5 patients because of the defect that arose on the oral mucosa above the carbon plates. During the long-term follow-up, plate fracture, loosening of the screws, infection or inflammations around the carbon/carbon implants were not observed. The thickness of the carbon fibres constituting the implants did not change during the 8-year period, the surface of the implant retrieved was covered with a thin surface layer not present on the unimplanted implant. The composition of this layer is identical to the composition of the underlying carbon fibres. Residual soft tissue penetrating the bulk material between the carbon fibre bunches was found on the retrieved implant indicating the importance of the surface morphology in tissue growth and adhering implants. Conclusions: The surface morphology and the structure were not changed after 8 years. The two main components of the implant retrieved from the human body are still carbon and oxygen, but the amount of oxygen is 3-4 times higher than on the surface of the reference implant, which can be attributed to the oxidative effect of the human body, consequently in the integration and biocompatibility of the implant. The clinical conclusion is that if the soft part cover is appropriate, the carbon implants are cosmetically and functionally more suitable than titanium plates.

임상에서 사용하고 있는 임플란트 토크조절기의 정확도와 적용에 관한 사용실태 (A study on accuracy and application of the implant torque controller used in dental clinic)

  • 주용훈;이진한
    • 대한치과보철학회지
    • /
    • 제49권3호
    • /
    • pp.197-205
    • /
    • 2011
  • 연구 목적: 임상에서 사용하고 있는 임플란트 토크조절기의 정확도를 평가하고, 사용방법에 있어서 적절하게 적용하고 있는지의 사용실태를 조사하였다. 연구 대상 및 방법: 대전, 충청지역의 개인 치과 의원을 방문하여 50명의 임상의와 진료실에서 사용하고 있는 50개의 임플란트 토크조절기를 연구 대상으로 하였다. 실험에 참가한 임상의의 임플란트 시술에 대한 정보를 얻기 위해 설문조사를 시행하였다. 설문조사 내용에는 임상경력과 임플란트 시술 경력, 임플란트 시술 도중 경험한 임플란트 나사의 파절과 풀림, 임플란트 토크조절기 사용법에 대한 교육 이수 여부, 토크조절기의 감염 관리 방법을 포함하였다. 또한 실험을 통하여 진료실에서 사용하고 있는 토크조절기의 정확도를 평가하였다. 임상의가 토크조절기를 사용하여 측정된 토크 값을 측정 한 후, 임플란트 토크조절기에 대한 교육 이수에 따른 측정된 토크 값의 평균을 독립 변수 T 검정법을 시행하여 95% 신뢰수준에서 유의성을 검증하였다. 결과: 임상의가 사용하는 토크조절기 자체의 정확도를 측정한 결과, 50개 토크조절기의 평균 오차율은 4.78%였다. 평가된 50개 토크 조절기 중 최대 오차율은 18.96%, 최소 오차율은 0.88% 였다. 임상의가 의도한 25 Ncm의 토크 값에 대해 실제 측정된 토크 값 평균은 $29.0{\pm}8.4$ Ncm 이었고, 30 Ncm의 토크 값에 대해 실제 측정된 토크 값 평균은 $34.3{\pm}9.1$ Ncm였다. 각각의 실험에서 임플란트 토크조절기에 대한 교육을 받은 실험 군과 받지 않은 실험 군 간에 평균 값에서 통계적으로 유의한 차이를 나타냈다. 결론: 임상가는 자신이 의도한 토크 값과 실제 임플란트 나사에 가해지는 토크 값에 차이가 발생할 수 있으므로, 자신이 사용하는 토크조절기의 정확한 사용방법을 숙지하여 일정하고 정확한 토크 값을 부여해야 한다. 또한 토크조절기가 일정하고 정확한 토크 값을 유지하도록 토크조절기를 유지, 관리하여야 나사의 파절이나 나사의 풀림의 문제를 최소화하는 임상적인 결과를 얻을 수 있을 것으로 사료된다.

유경나사를 이용한 견갑골 관절와 골절의 관절경적 정복 및 내고정 - 증례 보고 - (Arthroscopy Assisted Percutaneous Reduction and Screw Fixation of a Displaced Intra-articular Glenoid Fracture - A Case Report -)

  • 고상훈;전형민;신승명
    • Clinics in Shoulder and Elbow
    • /
    • 제13권1호
    • /
    • pp.127-131
    • /
    • 2010
  • 목적: 저자들은 관절와 골절의 치료에 있어 고식적인 관절 절개술이 아닌 관절경을 이용한 골절의 정복 및 내 고정한 증례를 보고 하고자 한다. 대상 및 방법: 66세의 남자로 좌측 견관절의 쇄골 골절 및 관절와의 전위된 횡 골절 및 견갑골 골절이 있는 환자였으며 관절경을 이용하여 골절을 정복하고 유경나사로 내 고정 하였다. 결과: 술 후 9개월 째 좌측 견관절의 운동 범위는 완전히 회복 되었으며 환자는 일상 생활에 불편감이 거의 없었다. 술 후 12개월째 전신 마취 하 내 고정물의 제거 술을 시행 하였다. 결론: 관절경을 이용한 수술은 고식적인 수술보다 적은 통증, 적은 출혈량, 술 후 입원기간의 단축 및 조기 관절 운동이 가능하다는 장점이 있었고 술 후 견관절 운동 범위에서도 우수한 결과를 보였으며 임상적 평가에서도 만족스러운 결과를 보였다.

Inlay법을 이용한 안와 내벽 골절의 교정 (Inlay Grafting for the Treatment of the Posterior Comminuted Fracture of Medial Orbital Wall)

  • 임종효;김태곤;이준호;김용하
    • 대한두개안면성형외과학회지
    • /
    • 제10권1호
    • /
    • pp.55-60
    • /
    • 2009
  • Purpose: For blowout fracture of the medial orbital wall, the goals of treatment are complete reduction of the herniated soft tissue and anatomic reconstruction of the wall without surgical complications. Surgeons frequently worry about damage to the optic nerve from the dissection, when the part over the posterior ethmoidal foramen was fractured. The authors performed small incision and inlay grafting for reconstruction of medial orbital wall fracture. Methods: Between January 2007 and April 2008, 15 out of 32 patients were included in an analysing the outcome of corrected medial orbital wall fracture. In 15 patients of posterior comminuted fracture of medial orbital wall, insertion of porous polyethylene($Medpor^{(R)}$ channel implant, Porex, USA) to ethmoidal sinus was performed in multiple layer, through the transconjunctival approach (inlay grafting). Results: In all cases, the orbital bone volume was reconstructed in its normal anatomical position. The associated ocular problems disappeared except for mild enophthalmos in 2 patients and there were no surgical complications associated with inlay grafting. Conclusion: The advantage of inlay grafting include anatomical reconstruction of the orbital wall; the avoidance of optic nerve injury; the simplicity of the procedure; and consequently, the absence of surgery-related complications. This technique is presented as one of the preferred treatments for posterior comminuted fracture of medial orbital wall.

Safety of Silastic Sheet for Orbital Wall Reconstruction

  • Moon, Seong June;Suh, Hyun Suk;Park, Bo Young;Kang, So Ra
    • Archives of Plastic Surgery
    • /
    • 제41권4호
    • /
    • pp.362-365
    • /
    • 2014
  • Background Many implants are being used for the reconstruction of orbital wall fractures. The effect of the choice of implant for the reconstruction of an orbital wall fracture on the surgical outcome is under debate. The purpose of this article is to compare the outcomes of orbital wall reconstruction of small orbital wall fractures on the basis of the implants used. Methods The authors conducted a retrospective study using electronic databases. Between March 2001 and December 2012, 461 patients with orbital wall fractures were included in this study. Among them, 431 patients in whom the fracture size was less than $300mm^2$ were analyzed. The fracture size was calculated using computed tomography scans of the orbit in the sagittal and coronal images. Cases in which the fracture size was less than $300mm^2$ were included in this study. Results One hundred and twenty-nine patients were treated with silastic sheets; 238 patients were treated with titanium meshes; and absorbable meshes were used in the case of 64 patients. Overall, 13 patients required revision, and the revision rate was 3.0%. The revision rate of the silastic sheet group was 5.4%. In the multivariable analysis, the revision rate of the group reconstructed with silastic sheets was highly statistically significant (P=0.043, odds ratio=3.65). However, other factors such as age, sex, fracture type, and fracture size were not significant. Conclusions Reconstruction of orbital wall fractures with silastic sheets may cause more complications than that with other materials such as titanium meshes and absorbable meshes.

치과용 임플란트 시스템의 기계적 가공오차에 관한 연구 (Machining Tolerance of Various Implant Systems and their Components)

  • 김형섭;권긍록;한중석
    • 구강회복응용과학지
    • /
    • 제24권1호
    • /
    • pp.57-65
    • /
    • 2008
  • 연구목적 : 본 연구에서는 rotational freedom을 측정할 수 있는 기구를 개발하여 시중에서 유통되고 있는 국산 임플란트 및 다양한 국적의 임플란트들의 기계적인 가공오차들을 측정하여 다양한 임플란트 시스템의 component간의 기계적인 안정성을 평가하고자 한다. 또한 본 연구에서는 더 나아가 최근에 임플란트 abutment로 각광을 받고 있는 각종 ceramic abutment의 절삭 가공오차에 관한 항목을 측정하여 임플란트 제조사 및 임상의들에게 올바른 정보를 제공하고자 한다. 연구재료 및 방법 : 국내에서 유통되는 외부연결구조의 외국산 임플란트 시스템(Nobel Biocare, Anthorgyr)과 국산 시스템(Neobiotec)과 내부연결구조의 임플란트 시스템(외국산:Nobel Biocare, Anthorgyr, Straumann, Frident Dentsply, 국산:Dentium) 별로 임플란트 fixture, abutment, analog를 서로 교차 연결하여 회전각도측정기(rotational angle measuring device)로 freedom of rotational angle을 측정하였다. 국산 외부연결구조의 지르코니아 abutment(ZirAce)를 외부연결구조의 임플란트 시스템(Neobiotec, Nobel Biocare, Anthorgyr)의 fixture와 analog와 교차연결하여 freedom of rotational angle을 측정하였다. 연구결과 : 국산 외부연결구조의 임플란트 시스템은 약 2.67도(fixture와 abutment 연결시), 내부연결구조의 임플란트는 약 4.3도(fixture와 abutment 연결시)의 rotational freedom을 보였다. 국산 지르코니아 abutment는 외국산 및 국산 외부연결구조 임플란트 시스템과 상관없이 3도 이하(fixture와 연결시)의 결과를 보였다. 결 론 : 시제품으로 제작된 디지털 회전각도측정기는 높은 분해능을 갖고 있었으며, 국산 임플란트의 기계적 가공오차는 외국산 임플란트와 거의 유사했다. 국산 세라믹 abutment의 기계적 가공오차는 fixture 제조회사별로 다르게 나타났지만 같은 회사의 절삭가공된 금속 abutment와 비교시 가공오차가 더 적었다.