CHANGES OF ABUTMENT SCREW AFTER REPEATED CLOSING AND OPENING

  • Kim Hee-Jung;Chung Chae-Heon;Oh Sang-Ho;Choi Han-Cheol
    • 대한치과보철학회지
    • /
    • 제42권6호
    • /
    • pp.628-640
    • /
    • 2004
  • Statement of problem. Wear as a result of repeated closing/opening cycles may decrease the friction coefficient of screw head, threads, and other mating components and, consequently, resistance to opening gradually decreases. It may cause screw loosening, which is one of the most common failures in implant prosthesis. Purpose. The purpose of this study is to evaluate the changes on the head and thread surface of the abutment screws after repeated closing and opening through the examination of tested screws in SEM(scanning electron microscope). Materials and methods. Five species of abutments were selected (3i-three, Avana-two) respectively by two pieces. The implant fixtures were perpendicularly mounted in liquid unsaturated polyesther(Epovia, Cray Valley Inc.) with dental surveyor. Each abutment was secured to the implant fixture by each abutment screw with recommended torque value using a digital torque controller. The abutment screws were repeatedly tightened and removed 20 times with a digital controller. FESEM (field emission scanning electron microscope, Netherland, Phillips co., model:XL 30 SFEG) was used to observe changes of each part caused by repeatedly closing/opening expeiment. First, the Photomicrographs of pre-test screws provided by each manufacturer were taken. The changes of each screw were investigated after every fifth closing and opening experiment with FESEM. Scaning electron microscope photomicrographs of each screw were taken four times. Results. As the number of closing and opening was increased, the wear or distortion of hexed or squared slot that contacted with the driver tip was more severely progressed. Wear or distortion of hexed slot was more severe than that of squared slot and it was more remarkable in the titanium screw than in the gold screw. All the tested screws showed that the width in the crest of their screw thread decreased gradually as the test was proceeded. Conclusions. Conclusively, we recommend the clinical use of gold screw, a periodic exchanges of abutment screws and avoiding repeated closing/opening unnecessarily. We also suggest a more careful manipulation of the abutment screw and screw-driver and using of abutment screw with an acute-angled slot design rather than an obtuse-angled one. Finally, it is suggested that the new slot design and the surface treatment for enduring wear or distortion should be devised.

AN EXPERIMENTAL STUDY OF NEWLY DESIGNED IMPLANT WITH RBM SURFACE IN THE RABBIT TIBIA : RESONANCE FREQUENCY ANALYSIS AND REMOVAL TORQUE STUDY

  • Won Mi-Kyoung;Park Chan-Jin;Chang Kyoung-Soo;Kim Chang-Whe;Kim Yung-Soo;Isa Zakiahbt Mohd;Ariffin Yusnidar Tajul
    • 대한치과보철학회지
    • /
    • 제41권6호
    • /
    • pp.720-731
    • /
    • 2003
  • Statement of problem. The importance of fixture design and surface treatment. Purpose. The clinical success of dental in plants is affected by many factors such like as degree of osseointegration, the effective load dispersion for the prostheses, and a lot of attempts have been made to overcome the difficulties. In this study, efforts were made to find the possibility of clinical acceptance of the dental implants of newly designed surface and resorbable blast media surcace. Materials and methods. In this study, two groups of custom-made, screw-shaped implants were prepared. The first with the consisting of Branemark clone design and the other with the new design. These implants were divided into four groups according to the kinds of surface treatment. Four implants($AVANA^{(R)}$, Osstem, Busan, Korea)of each group were installed in twenty rabbits. Group A was consisted of Branemark done implant left as machined, Group B with Branemark clone implants with RBM(Resorbable blast media) surface, Group C with newly designed implants left as machined and Group D with newly designed implants with RBM surface. One of the twenty rabbits died from inflammation and the observation was made for six weeks. Specimens from four groups were observed using scanning electron microscopy with 40, 100, 1000 magnification power and microsurface structures were measured by white-light scanning interferometry for three dimensional surface roughness measurements(Accura $2000^{(R)}$, Intek-Plus, Korea.). Removal torque was measured in 17 rabbits using digital torque gauge(MGT 12R, Mark-10 corp., NY, U.S.A.) immediately after the sacrifice and two rabbits were used for the histologic preparation(EXAKT $310^{(R)}$, Heraeus Kulzer, wehrheim, Germany) of specimens and observed under light microscope. Resonance frequency measurement($Osstell^{(R)}$) was taken with the 19 rabbits at the beginning of the implant fixation and immediately after the sacrifice. Results. Following results were taken from the experiment. 1. The surface of the RBM implants as seen with SEM had rough and irregular pattern with reticular formation compared to that of fumed specimens showing different surface topographies. 2. The newly designed implant with RBM surface had high removal torque value among four groups with no statistical significance. The average removal torque was $49.95{\pm}6.70Ncm$ in Group A, $51.15{\pm}4.40Ncm$ in Group B, $50.78{\pm}9.37Ncm$ in Group C, $51.09{\pm}4.69Ncm$ in Group D. 3. The RFA values were $70.8{\pm}4.3Hz$ in Group A, $71.8{\pm}3.1Hz$ in Group B, $70.9{\pm}2.5Hz$, $72.7{\pm}2.5Hz$ in Group D. Higher values were noted in the groups which had surface treatment compared to the untreated groups with no statistical significance. 4. The results from the histomorphometric evaluation showed a mean percentage of bone-to-implant contact of $45{\pm}0.5%$ in Group A, $55{\pm}3%$ in Group B, $49.5{\pm}0.5%$ in Group C, and $55{\pm}3%$ in Group D. Quite amount of newly formed bone were observed at the surface RBM-treated implants in bone marrow space.

시멘트의 종류 및 임플란트 지대주 높이가 지르코니아 수복물의 제거력에 미치는 영향 (Influence of varying cement types and abutment heights on pull-off force of zirconia restorations)

  • 정영준;김유리;정지혜;강내운;공현준
    • 구강회복응용과학지
    • /
    • 제40권2호
    • /
    • pp.64-71
    • /
    • 2024
  • 목적: 본 연구의 목적은 세 가지 높이를 가진 티타늄 베이스 임플란트 지대주에서 세 종류의 시멘트가 지르코니아 수복물에서 가지는 제거력을 비교하는 것이다. 연구 재료 및 방법:. 90개의 직경 4.0 mm 임플란트 아날로그가 레진 블록에 식립되었다. 이후 3 mm, 5 mm, 7 mm의 높이를 가지도록 임플란트 지대주를 30개씩 제작하였고, 각 지대주를 스캔하여 지르코니아 수복물 시편을 제작하였다. 임시 시멘트(TB), 반영구 시멘트(CI), 영구 시멘트(FC)를 각자 제조사의 지시에 따라 지대주에 접착하였다. 제작된 90개의 시편은 만능시험기에서 제거력을 시험하였으며, 모든 제거력은 부하량이 하락하기 직전 가장 높은 값에서 측정되었다. 통계 분석은 지대주의 높이, 시멘트의 종류에 대해 각각 Kruskal-Wallis test (P = 0.05) 후 Mann-Whitney U test (P = 0.0167)로 사후 검정 시행하였다. 결과: 임플란트 지대주의 높이에 상관없이 TB에 비해 FC의 제거력이 높았다. CI와 FC간에는 3 mm와 7 mm에서는 유의미한 차이가 있었으나 5 mm에서는 유의미한 차이가 없었다. TB와 CI간에는 5 mm에서만 유의미한 차이가 있었다. 결론: 시멘트의 종류는 지르코니아 수복물의 제거력에 유의미한 영향을 끼쳤으나, 임플란트 지대주의 높이는 유의미한 영향을 주지 않았다.

임플란트 식립 초기 의원성 동요가 최종 골결합에 미치는 영향 (The influence of iatrogenic mobilization in the initial stage of implant installation on final osteointegration)

  • 곽명배;조진현;이두형;이청희
    • 대한치과보철학회지
    • /
    • 제52권2호
    • /
    • pp.105-112
    • /
    • 2014
  • 연구 목적: 이 연구의 목적은 임플란트 식립 초기 수회의 의원성 동요가 최종 골결합에 미치는 영향을 확인하는 것이다. 연구 재료 및 방법: 순수한 티타늄(Grade IV) 으로 직경 3.75 mm, 길이 8 mm의 실험용 임플란트를 제작한 후, 하방 4 mm에 RBM 표면처리($MegaGen^{(R)}$: Ca-P)를 하였다. 임플란트의 하부만 골에 식립되었으며 비침하시켰다. 수술은 3.5 kg이상의 토끼의 좌우 경골의 단층 치밀골에 각각 2개씩 130개를 통상적인 방법으로 식립하였다(Female, New Zealand White). 비틀림 제거 간격에 따라, 다음과 같은 13개의 군으로 나누었다; Group I (1일), Group II (1일 + 2일), Group III (1일 + 2일 + 3일), Group IV (1일 + 2일 + 3일 + 4일), Group V (2일), Group VI (2일 + 4일), Group VII (2일 + 4일 + 6일), Group VIII (2일 + 4일 + 6일 + 8일), Group IX (4일), Group X (4일 + 7일), Group XI (4일 + 7일 + 10일), Group XII (4일 + 7일 + 10일 + 14일), 그리고 대조군. 대조군은 식립 후 8주의 치유기간을 준 후 최종 비틀림 제거력을 측정하였다(Mark-10, USA). 실험군은 각각의 조건에 맞추어 1회에서 4회에 걸쳐 비틀림 제거력을 측정하였다. 비틀림 제거력을 측정한 이후에 대체적으로 임플란트를 측정 전의 위치로 재위치시켰다. 모든 실험군에서 임플란트 식립 후 8주간의 치유기간을 준 다음 최종 비틀림 제거력을 측정하여 대조군, 각 실험군의 1, 2, 3, 4번째 비틀림 제거력과 비교하였다. 결과: 실험군 간에 최종 비틀림 제거력을 비교한 결과에서, XII군을 제외한 실험군의 비틀림 제거력은 대조군과 유의할만한 차이를 보이지는 않았다. 그리고 실험 I군과 II군의 값은 VI, VIII, X, XI, XII군의 값보다 유의하게 높게 나타났다. 그리고 III, IV, V군은 XI, XII군의 값보다 유의하게 높게 나타났다. 각 실험군간 비틀림 제거력 비교에서, 최종 비틀림 제거력은 VIII, X, XI, XII군을 제외한 모든 군에서 높게 나타났다. 결론: 충분한 치유기간이 주어진다면, 토끼에게 임플란트 식립 후 매우 이른 초기에 지대주에 가해지는 약간의 동요는 임플란트 골결합에 영향을 미치지 않았다.

두 종의 external hex implant의 변연골 흡수에 관한 연구 : 예비연구 (preliminary study) (Radiographic evaluation of marginal bone resorption around two types of external hex implants : preliminary study)

  • 이지은;허성주;곽재영;김성균;한종현
    • 대한치과보철학회지
    • /
    • 제46권2호
    • /
    • pp.169-174
    • /
    • 2008
  • 목적: 치과 임플랜트 주위의 변연골 변화는 임플랜트의 기능적인 유지 뿐만 아니라 심미적 성공을 위해서도 중요하다. 변연골의 유지를 위한 임플랜트 디자인이 연구되고 있다. 이번 예비 연구는 두 종류의 external hex implant 시스템에서 임플랜트의 상부 미세 나사산이 변연골 변화량에 미치는 영향을 평가하고자 한다. 재료 및 방법: 총 24명의 환자를 대상으로 $Br{{\aa}}nemark$ 임플랜트 식립군 (1군, 거친 표면 임플랜트, 20개)과 원플란트 임플랜트 식립군 (2군, 미세나사산을 가진 거친 표면 임플랜트, 20개)으로 분류하였다. 기준 시점 (임플랜트 부하)과 부하를 가한 1년 뒤 임상적, 방사선학적 검사를 시행하였다. UTHSCSA Image Tool을 이용하여 임플랜트-보철 경계부로부터 변연골 높이 변화량으로 계측하였다. 계측치는 SAS 프로그램을 이용하여 three-level ANCOVA로 통계처리 하였다. 결과: 기준 시점과 비교하여 1년 기능 후, 두 그룹 간의 변연골 소실 변화량에 있어서 통계학적으로 유의한 차이가 있었다 (P<0.05). 1군의 평균 변연골 높이 변화량은 $0.83{\pm}0.31mm$, 2군에 있어서는 $0.44{\pm}0.36mm$ 이었다. 미세나사산을 가진 거친 표면 임플랜트가 미세나 사산을 가지지 않은 거친 표면 임플랜트 보다 더 적은 변연골 소실 변화량을 보였다. 결론: 미세나사산을 가진 거친 표면 임플랜트가 기능적 부하 후 변연골 높이를 유지하는데 있어 더 유리한 디자인으로 보인다.

양극산화 임플란트 표면에 적용된 헤파린과 골형성단백질(rhBMP-2)이 치조골 증대에 미치는 효과: 방사선학적 평가 (Effect of immobilization of the recombinant human bone morphogenetic protein 2 (rhBMP-2) on anodized implants coated with heparin for improving alveolar ridge augmentation in beagle dogs: Radiographic observations)

  • 이소현;조재영;윤미정;전영찬;허중보;정창모
    • 대한치과보철학회지
    • /
    • 제51권4호
    • /
    • pp.307-314
    • /
    • 2013
  • 연구 목적: 본 연구는 골형성단백질의 서방출을 위해 헤파린과 골형성단백질 (rhBMP-2)을 화학적으로 고정시킨 양극산화 티타늄 임플란트가 골 결손부에서 임플란트 주변의 수직적 골증대에 미치는 효과를 방사선학적으로 평가하고자 시행되었다. 연구 재료 및 방법: Pure-Titanium을 사용하여 길이 7.0 mm, 직경 3.5 mm의 실험용 임플란트 18개를 제작하였다. 모든 임플란트를 양극산화처리 하였고, 플랫폼 하방 2.5 mm에 식립 기준선을 표시하였다. rhBMP-2가 코팅되지 않은 임플란트 집단을 대조군으로, dip and dry 방법으로 rhBMP-2를 물리적 흡착시킨 집단을 BMP군, 3,4-dihydroxyphenylalanine(DOPA)-heparin을 이식하고 rhBMP-2를 화학적으로 고정시킨 집단을 Hep-BMP군으로 설정하였다. 각군별6개씩의 임플란트를 3마리의 비글견 양측 하악에 한쪽에 3개씩 총 18개를 치조정 상방으로 2.5 mm 노출시켜 식립하였다. 식립 직후와 4주, 8주에 식립부위의 방사선학적 검사가 시행되었고, 각 시기별, 각 군별 임플란트의 근원심 변연골의 수직적 재생량에 대한 평균값과 표준편차를 얻었다. Kruskal-Wallis test와 Mann-Whitney U test를 이용하여 4주, 8주에서 대조군과 실험군들의 차이를 비교 분석하고, 유의 수준5%에서 통계적으로 검정하였다. 결과:방사선학적 관찰 결과 임플란트 근원심 변연골 재생량(평균값 ${\pm}$ 표준편차)은 4주에 대조군은 $0.09{\pm}0.22mm$, BMP군은 $1.02{\pm}0.72mm$, Hep-BMP군은 $1.29{\pm}0.51mm$ 였으며, 8주에서는 각각 $0.11{\pm}1.26mm$, $1.11{\pm}0.58mm$, $1.59{\pm}0.79mm$였다. 두 실험군 모두 4주와 8주에서 대조군과 비교 시 유의한 수직적 골증대를 나타냈으나(P<.05), Hep-BMP군과BMP군의 비교에서는 유의한 변연골 재생량 차이를 보이지 않았다(P>.05). 결론: 골형성단백질을 물리적으로 흡착시키거나 서방출 위해 헤파린을 이용하여 화학적으로 고정시킨 양극산화 임플란트 표면은 모두 골 결손부에서 임플란트 주변골의 수직적 증대에 효과적이었다. 그러나 방사선학적 관찰의 한계 내에서 골형성단백질의 이 두가지 적용방법간에는 수직적 골증대량에 유의한 차이가 없었다.