The relationship between initial implant stability quotient values and bone -to-implant contact ratio in the rabbit tibia

  • Park, In-Phill;Kim, Seong-Kyun;Lee, Shin-Jae;Lee, Joo-Hee
    • The Journal of Advanced Prosthodontics
    • /
    • 제3권2호
    • /
    • pp.76-80
    • /
    • 2011
  • PURPOSE. Implant stability quotient (ISQ) values have been supposed to predict implant stability. However, the relationship between ISQ values and bone-to-implant contact ratio (BIC%) which is one of the predictors of implant stability is still unclear. The aim of the present study was to evaluate initial ISQ values in relation to BIC% using rabbit model. MATERIALS AND METHODS. Four New Zealand white rabbits received a total of 16 implants in their tibia. Immediately after implant placement ISQ values were assessed. The measurements were repeated at the time of sacrifice of the rabbits after 4 weeks. Peri-implant bone regeneration was assessed histomorphometrically by measuring BIC% and bone volume to total volume values (bone volume %). The relationships between ISQ values and the histomorphometric output were assessed, and then, the osseointegration prediction model via the initial ISQ values was processed. RESULTS. Initial ISQ values showed significant correlation with the BIC%. The bone volume % did not show any significant association with the ISQ values. CONCLUSION. In the limitation of this study, resonance frequency analysis is a useful clinical method to predict the BIC% values and examine the implant stability.

Effect of bone quality and implant surgical technique on implant stability quotient (ISQ) value

  • Yoon, Hong-Gi;Heo, Seong-Joo;Koak, Jai-Young;Kim, Seong-Kyun;Lee, Su-Young
    • The Journal of Advanced Prosthodontics
    • /
    • 제3권1호
    • /
    • pp.10-15
    • /
    • 2011
  • PURPOSE. This study investigated the influence of bone quality and surgical technique on the implant stability quotient (ISQ) value. In addition, the influence of interfacial bone quality, directly surrounding the implant fixture, on the resonance frequency of the structure was also evaluated by the finite element analysis. MATERIALS AND METHODS. Two different types of bone (type 1 and type 2) were extracted and trimmed from pig rib bone. In each type of bone, the same implants were installed in three different ways: (1) Compaction, (2) Self-tapping, and (3) Tapping. The ISQ value was measured and analyzed to evaluate the influence of bone quality and surgical technique on the implant primary stability. For finite element analysis, a three dimensional implant fixture-bone structure was designed and the fundamental resonance frequency of the structure was measured with three different density of interfacial bone surrounding the implant fixture. RESULTS. In each group, the ISQ values were higher in type 1 bone than those in type 2 bone. Among three different insertion methods, the Tapping group showed the lowest ISQ value in both type 1 and type 2 bones. In both bone types, the Compaction groups showed slightly higher mean ISQ values than the Self-tapping groups, but the differences were not statistically significant. Increased interfacial bone density raised the resonance frequency value in the finite element analysis. CONCLUSION. Both bone quality and surgical technique have influence on the implant primary stability, and resonance frequency has a positive relation with the density of implant fixture-surrounding bone.

The influence of bone graft procedures on primary stability and bone change of implants placed in fresh extraction sockets

  • Jun, Sang Ho;Park, Chang-Joo;Hwang, Suk-Hyun;Lee, Youn Ki;Zhou, Cong;Jang, Hyon-Seok;Ryu, Jae-Jun
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제40권
    • /
    • pp.8.1-8.6
    • /
    • 2018
  • Background: This study was to evaluate the effect of bone graft procedure on the primary stability of implants installed in fresh sockets and assess the vertical alteration of peri-implant bone radiographically. Methods: Twenty-three implants were inserted in 18 patients immediately after tooth extraction. The horizontal gap between the implant and bony walls of the extraction socket was grafted with xenografts. The implant stability before and after graft procedure was measured by Osstell Mentor as implant stability quotient before bone graft (ISQ bbg) and implant stability quotient after bone graft (ISQ abg). Peri-apical radiographs were taken to measure peri-implant bone change immediately after implant surgery and 12 months after implant placement. Data were analyzed by independent t test; the relationships between stability parameters (insertion torque value (ITV), ISQ abg, and ISQ bbg) and peri-implant bone changes were analyzed according to Pearson correlation coefficients. Results: The increase of ISQ in low primary stability group (LPSG) was 6.87 ± 3.62, which was significantly higher than the increase in high primary stability group (HPSG). A significant correlation between ITV and ISQ bbg (R = 0.606, P = 0.002) was found; however, age and peri-implant bone change were not found significantly related to implant stability parameters. It was presented that there were no significant peri-implant bone changes at 1 year after bone graft surgery. Conclusions: Bone graft procedure is beneficial for increasing the primary stability of immediately placed implants, especially when the ISQ of implants is below 65 and that bone grafts have some effects on peri-implant bone maintenance.

임플랜트 고정체의 형태가 임플랜트 초기안정성에 미치는 영향 (INFLUENCE OF IMPLANT FIXTURE DESIGN ON IMPLANT PRIMARY STABILITY)

  • 오갑용;박성화;김석규
    • 대한치과보철학회지
    • /
    • 제45권1호
    • /
    • pp.98-106
    • /
    • 2007
  • Statement of problem: Current tendencies of the implant macrodesign are tapered shapes for improved primary stability, but there are lack of studies regarding the relationship between the implant macrodesign and primary stability. Purpose: The purpose is to investigate the effect of implant macrodesign on the implant primary stability by way of resonance frequency analysis in the bovine rib bones with different kinds of quality. Material and method: Fifty implants of 6 different kinds from two Korean implant systems were used for the test. Bovine rib bones were cut into one hundred pieces with the length of 5 cm. Among them forty pieces of rib bones with similar qualities were again selected. For the experimental group 1, the thickness of cortical part was measured and 20 pieces of rib bones with the mean thickness of 1.0mm were selected for implant placement. For the experimental group 2, the cortical parts of the remaining 20 pieces of rib bones were totally removed and then implants were placed on the pure cancellous bone according to the surgical manual. After placement of all implants, the implant stability quotient(ISQ) was measured by three times, and its statistical analysis was done. Results: There are statistically significant differences in ISQ values among 4 different kinds of Avana system implants in the experimental group 2. For the experimental group 1, Avana system implants showed significantly different ISQ values, but when differences in the thickness of cortical parts were statistically considered, did not show any significant differences in ISQ values. Among Oneplant system implants, there are no significant differences in ISQ values for the experimental group 2 as well as for the experimental group 1. Conclusion: Within the limits of this study, bone quality and implant design have some influences on the primary stability of implants. Especially in the bone of poor quality, tapered shape of implants are more favorable for the primary stability of implants.

$Periotest^(R)$ Value와 Implant Stability Quotient에 영향을 미치는 요소 (THE INFLUENCING FACTORS OF $PERIOTEST^(R)$ VALUE AND IMPLANT STABILITY QUOTIENT)

  • 이영아;차인호;이호용;한동후
    • 대한치과보철학회지
    • /
    • 제44권1호
    • /
    • pp.40-50
    • /
    • 2006
  • Statement of problem: $Periotest^(R)\;and\;Osstell^{TM}$ were known as the most objective and quantitative mobility tests available for evaluating stability of implant in vivo. Although a correlation between PTV widely used and ISQ recently introduced exist, a PTV was corresponded to various ISQ. A correct evaluation of implant stability could be obtained only after one has a thorough understanding of the limitations of devices and factors that affect measurements. Purpose: The purpose of this study was to investigate the causes of variables in the values obtained with these two tests. Material and method: A total of 333 implants 134 $Br{\aa}nemark$, 5 Silhouette and 194 ITI implants were investigated. Result: 1. There was a correlation between PTV and ISQ (Spearman correlation =0.39, p<0.0001) 2. The factors that affected ISQ were diameter of implant future, location of implant and implant system (submerged type vs non-submerged type). 3. The factors that affected W were dimeter of implant future, location of implant, and elapsed time after implant placement. 4. There was no significant difference between different surface treatments of RBM, smooth surface and ti-unite on PTY and ISQ. 5. In radiographic finding, no saucerization or bone resorption has been detected in implants with ISQ values that were above the average level of each PTV. These higher values had higher bone densities around the implant fixture. Saucerization was observed in the most impants with ISQ values that were below the average level of each PTV. Conclusion: There was a correlation between ISQ and PTV. However, each measuring methods had factors influencing the measured values. PTV were less sensitive to marginal bone resorption and influenced with the striking point on an implant to the level of bone. With ISQ, the height of implant from bone level to transducer should be considered.

테이퍼드 직선형 SLA 임플란트의 안정성 평가 (Evaluation of the stability of sandblasted, large-grit, acid-etched implants with tapered straight body design)

  • 김용건;이규복
    • 구강회복응용과학지
    • /
    • 제34권2호
    • /
    • pp.80-88
    • /
    • 2018
  • 목적: 임플란트 표면의 특성과 임플란트 디자인은 성공적인 초기 고정을 얻는데 중요한 변수이다. 이 연구의 목적은 치유기간 동안 테이퍼드 직선형 디자인을 가진 SLA (Sandblasted and Acid-etched) 임플란트의 ISQ (Implant Stability Quotient) 값을 측정하고 임플란트의 안정성에 미치는 영향을 평가하는 것이다. 연구 재료 및 방법: 임플란트의 안정성을 측정하기 위하여 26명의 환자(여자 13명, 남자 13명)의 44개 임플란트에 대한 자기공명주파수분석(Resonance Frequency Analysis)을 실시하였다. 골질 및 골량에 대한 임상적 평가는 Lekholm & Zarb (1985)의 기준에 따라 시행하였다. 시간경과에 따른 임플란트 안정성변화(총 ISQ 값)를 고정체 식립 시 그리고 12주후 치유지대주 연결 시 측정하고 RFA와 식립토크, RFA와 골질, RFA와 상, 하악골 사이의 상관관계를 평가하였다. 결과: 임플란트의 평균 ISQ값은 임플란트 식립 당시(기준선) $69.4{\pm}10.2$, 치유지대주연결에서(두번째수술) $81.4{\pm}6.9$였다(P < 0.05). RFA와 골질, RFA와 상하악골 사이에 유의한 차이가 있었다(P < 0.05). RFA와 식립토크, 식립부위, 고정체 직경, 임플란트 길이 사이에는 유의한 차이가 없었다(P > 0.05). 결론: 본 연구의 제한된 범위내에서 테이퍼드 직선형 디자인을 가진 SLA 임플란트의 ISQ값은 고정체 식립시와 치유지대주 연결 시 모두 높은 값을 보였다. 따라서 테이퍼드 직선형 디자인을 가진 SLA 임플란트는 초기안정성 및 2차 안정성을 향상시킬 수 있으며, 즉시 또는 초기하중을 적용할 수 있을것으로 사료된다.

A STUDY ON THE CORRELATION BETWEEN IMPLANT STABILITY VALUES AND INITIAL INSERTION TORQUE

  • Lee Jong-Hyuk;Yang Jae-Ho
    • 대한치과보철학회지
    • /
    • 제44권3호
    • /
    • pp.314-324
    • /
    • 2006
  • Statement of problem. Osseointegration is important mechanism of dental implant but it is not easy to evaluate. Indirect measurement is non-invasive and clinically applicable but they need more study about correlation between indirect values and degree of osseointegration. Purpose. The aims of this study were to evaluate the coefficient of correlation between indirect measurement and direct measurement under different healing time, and assessment of effect of initial insertion torque to the implant stability. Material and Methods. 20 rabbits received 3 implants on each side of tibia. Three kinds of implants (machined surface implant, Sandblasted with Large grit and Acid etched implant, Resorbable Blast Media treated implant) were used. During the surgery implant insertion torque were measured with $Osseocare^{TM}$. After the 1, 4, 8, 12 weeks of healing time, animals were sacrificed and stability values (Implant Stability Quotient with $Osstell^{TM}$, removal torque with torque gauge) were measured. Results. The Bone quality of rabbit tibia was classified into 2 groups according to the insertion torque. Resonance frequency analysis (ISQ) and removal torque showed positive correlation until $4^{th}$ week (r=0.555, p=0.040). After $8^{th}$ week (r=0.011, p=0.970) the correlation became weak and it turned negative at $12^{th}$ week (r=-0.074, p=0.801). Insertion torque and ISQ showed changing correlation upon the healing time ($1^{st}$ week: r=0.301, p=0.033, $4^{th}$ week: r=-0.429, p=0.018, $8^{th}$ week: r=0.032, p=0.865, $12^{th}$ week: r=-0.398, p=0.029). Insertion torque and removal torque has positive correlation but it was not statistically significant ($1^{st}$ week: r=0.410, p=0.129, $4^{th}$ week: r=0.156, p=0.578, $8^{th}$ week: r=0.236, p=0.398, $12^{th}$ week: r=0.260, p=0.350). Conclusion. In this study, bone quality may affect the degree of osseointegration positively during healing time and correlation between ISQ and degree of osseointegration can be different according to the healing time and bone quality.

A clinical study of alveolar bone quality using the fractal dimension and the implant stability quotient

  • Lee, Dae-Hyun;Ku, Young;Rhyu, In-Chul;Hong, Jeong-Ug;Lee, Cheol-Woo;Heo, Min-Suk;Huh, Kyung-Hoe
    • Journal of Periodontal and Implant Science
    • /
    • 제40권1호
    • /
    • pp.19-24
    • /
    • 2010
  • Purpose: It has been suggested that primary implant stability plays an essential role in successful osseointegration. Resonance frequency analysis (RFA) is widely used to measure the initial stability of implants because it provides superior reproducibility and non-invasiveness. The purpose of this study is to investigate whether the fractal dimension from the panoramic radiograph is related to the primary stability of the implant as represented by RFA. Methods: This study included 22 patients who underwent dental implant installation at the Department of Periodontology of Seoul National University Dental Hospital. Morphometric analysis and fractal analysis of the bone trabecular pattern were performed using panoramic radiographs, and the implant stability quotient (ISQ) values were measured after implant installation using RFA. The radiographs of 52 implant sites were analyzed, and the ISQ values were compared with the results from the morphometric analysis and fractal analysis. Results: The Pearson correlation showed a linear correlation between the ISQ values of RFA and the parameters of morphometric analysis but not of statistical significance. The fractal dimension had a linear correlation that was statistically significant. The correlation was more pronounced in the mandible. Conclusions: In conclusion, we suggest that the fractal dimension acquired from the panoramic radiograph may be a useful predictor of the initial stability of dental implants.

The reliability of Anycheck device related to healing abutment diameter

  • Lee, Dong-Hoon;Shin, Yo-Han;Park, Jin-Hong;Shim, Ji-Suk;Shin, Sang-Wan;Lee, Jeong-Yol
    • The Journal of Advanced Prosthodontics
    • /
    • 제12권2호
    • /
    • pp.83-88
    • /
    • 2020
  • PURPOSE. The purpose of this in vitro study was to examine the reliability of the Anycheck device and the effect of the healing abutment diameter on the Anycheck values (implant stability test, IST). MATERIALS AND METHODS. Thirty implants were placed into three artificial bone blocks with 10 Ncm, 15 Ncm, and 35 Ncm insertion torque value (ITV), respectively (n = 10). (1) The implant stability was measured with three different kinds of devices (Periotest M, Osstell ISQ Mentor, and Anycheck). (2) Five different diameters (4.0, 4.5, 4.8, 5.5, and 6.0 mm) of healing abutments of the same height were connected to the implants and the implant stability was measured four times in different directions with Anycheck. The measured mean values were statistically analyzed. RESULTS. The correlation coefficient between the mean implant stability quotient (ISQ) and IST value was 0.981 (P<.01) and the correlation coefficient between the meant periotest value (PTV) and IST value was -0.931 (P<.01). There were no statistically significant differences among the IST values with different healing abutment diameters. CONCLUSION. There was a strong correlation between the Periotest M and Anycheck values and between the ISQ and IST. The diameter of the healing abutment had no effect on the Anycheck values.

연질 골에서 두 종류의 테이퍼 형태 임플란트의 초기 안정성에 관한 실험실적 연구 (In Vitro Study on the Initial Stability of Two Tapered Dental Implant Systems in Poor Bone Quality)

  • 김덕래;김명주;권호범;이석형;임영준
    • 구강회복응용과학지
    • /
    • 제25권4호
    • /
    • pp.391-401
    • /
    • 2009
  • 임플란트의 성공은 식립 후의 초기 안정성 (Initial stability)의 결과가 중요한 영향을 준다. 이 연구의 목적은 연질 골에서 두 종류의 테이퍼 형태 임플란트가 임플란트의 디자인과 self-tapping blade의 유무에 따라서 초기 안정성에 주는 영향을 알아보는 것이다. Self-tapping blade를 가지고 있는 것과 가지고 있지 않은 두 종류의 테이퍼 형태 임플란트가 사용되었다. Solid Rigid Polyurethane Form으로 연질 골 상태인 D4 골 모형을 재현하였다. 임플란트 고정체를 식립하면서 초기 안정성 값을 기록하고, 식립 직후 implant stability quotient (ISQ)을 측정하여 Resonance frequency Analysis (RFA)를 평가하였다. 마지막으로 임플란트가 식립된 모형골을 만능 시험기에 부착하여 장축 방향으로의 pull-out force를 측정하였다. 초기 안정성 값과 최대 pull-out torque 값은 non self-tapping implants가 self-tapping group에 비하여 통계학적으로 유의하게 큰 평균값을 나타냈다 (P = 0.008). 공진 주파수 분석 결과인 ISQ 값은 거의 비슷한 평균값을 보였으면 통계학적으로 차이가 없었다. 각 임플란트 시스템에서 식립 토크와 pull-out 최대 토크 그리고 공진 주파수 간에는 상관관계를 나타내지 않았다. Non self-tapping 임플란트의 높은 식립 토크는 임상적으로 우수한 초기 안정성을 의미한다. 결론적으로 연질 골에서 self-tapping blade가 없는 임플란트가 있는 것 보다 더 우수한 초기 안정성을 보였다.