• 제목/요약/키워드: Impedance tube method

검색결과 82건 처리시간 0.031초

Mciro-flown 속도센서를 이용한 흡음률 측정 (Sound Absorption Measurement by Using Micro-Flown Velocity Sensor)

  • 정성수;조문재;김용태
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2004년도 춘계학술대회논문집
    • /
    • pp.692-693
    • /
    • 2004
  • We introduce a new velocity sensor, micro-flown sensor, which was developed by H-E de Bree. The sound absorption coefficients of a fiber material with the conventional pressure microphones and the micro-flown sensors were measured and compared. The experimental results show that both sensors could be well applied to measure the sound absorption coefficient but the pressure sensor was rather stable than micro-flown sensor

  • PDF

신경회로망을 이용한 원전SG 세관 결함크기 예측 (Prediction of Defect Size of Steam Generator Tube in Nuclear Power Plant Using Neural Network)

  • 한기원;조남훈;이향범
    • 비파괴검사학회지
    • /
    • 제27권5호
    • /
    • pp.383-392
    • /
    • 2007
  • 본 논문에서는 신경회로망을 이용하여 원자력 발전소 증기발생기 세관의 결함 깊이와 폭을 예측하는 연구를 수행한다. 결함 크기 추정을 위하여 우선, I-In 형태, I-Out 형태, V-In 형태, V-Out 형태의 4가지 결함형상에 대한 와전류탐상시험(ECT) 신호를 생성한다. 특히, 유한요소법에 기반한 수치해석 기법을 이용하여 여러 가지 폭과 깊이를 갖는 결함 400개의 ECT 신호를 생성한다. 이와 같이 생성된 ECT 신호로부터, 결함 크기와 폭을 예측하기 위한 새로운 특징벡터를 추출하는데, 이 특징벡터에는 최대 임피던스 값을 갖는 점과 최대 임피던스값의 1/2의 값을 갖는 점 사이의 위상각이 포함된다. 추출된 특징벡터를 이용하여 결함의 크기를 예측하기 위해서 하나의 은닉층을 갖는 다층퍼셉트론을 이용하였다. 컴퓨터 모의실험 연구를 통하여 제안된 방법이 우수한 예측성능을 갖는다는 것을 보였다.

INSERTION LOSS MEASUREMENT OF SILENCERS BY DOUBLE PAIR MICROPHONE TECHNIQUE

  • Jung, S.S.;Pu, Y.C.;Kim, M.G.
    • 한국음향학회:학술대회논문집
    • /
    • 한국음향학회 1994년도 FIFTH WESTERN PACIFIC REGIONAL ACOUSTICS CONFERENCE SEOUL KOREA
    • /
    • pp.704-709
    • /
    • 1994
  • The insertion loss is the measured change in power flux at a specified receiver, when the acoustic transmission path between it and the source is modified by the insertion of silencer element. Such measurements have clear and valid physical meaning particularly if the source impedance remains while the transmission path is altered. When the invarient condition is satisfied, the insertion loss is given by the ratio of the acoustic pressure in upstream to that in downstream of the silencer, and that of the particle velocity. The measurement is consisted of using an adaptation of the two microphone method to obtain the complex amplitude of the sound in upstream tube as well as in downstream tube of the silencer. Examples of the data, reduced and presented in terms of the pressure ratio and particle speed ratio, are compared with the theoretical calculations.

  • PDF

그라파이트 인터칼레이션 컴파운드가 에폭시 복합재료의 흡·차음성에 미치는 영향 (Effect of Graphite Intercalation Compound on the Sound Absorption Coefficient and Sound Transmission Loss of Epoxy Composites)

  • 이병찬;박규대;최성규;김성룡
    • Composites Research
    • /
    • 제28권6호
    • /
    • pp.389-394
    • /
    • 2015
  • 팽창된 그라파이트 인터칼레이션 컴파운드에 에폭시 수지를 주입하여 제조한 복합재료의 흡 차음성을 연구하였다. 관내법을 이용하여 복합재료의 흡음률과 음향투과손실을 측정하였다. 주사전자현미경을 이용하여 에폭시 매트릭스 내부에 그라파이트 인터칼레이션 컴파운드가 무질서한 방향으로 균일하게 분산된 것을 확인하였다. 그라파이트 인터칼레이션 컴파운드 함량이 증가함에 따라 복합재료의 면밀도가 감소하였으며, epoxy/(GIC 20 wt%) 복합재료의 면밀도는 순수 에폭시에 비하여 56% 감소하였다. 500~1000 Hz 주파수 영역에서 복합재료의 흡음률은 순수 에폭시에 비해 3배 정도 증가하였다. 그라파이트 인터칼레이션 컴파운드의 함량이 증가함에 따라 복합재료에 포함된 기공의 비율이 증가하여 순수 에폭시에 비하여 복합재료의 음향투과손실이 감소하는 것으로 판단된다.

대형 스플리터 소음기 성능에 대한 3차원 수치해석적 연구 (Three-dimensional Numerical Study on Acoustic Performance of Large Splitter Silencers)

  • 백성현;이창헌;권대훈;이일재
    • 한국소음진동공학회논문집
    • /
    • 제27권2호
    • /
    • pp.139-147
    • /
    • 2017
  • Acoustic performance of splitter silencers was investigated by using 3-dimensional commercial software and experiments. Flow resistivity of sound absorbing material was indirectly estimated by using an impedance tube setup and a curve fitting method. In addition the acoustic impedance of perforated plate was determined by an empirical formulation. Such properties have been used as input parameters in the commercial software. The prediction for a splitter silencer with 1000 mm length was compared with the experimental result. The numerical method is then applied to identify the effects of number of splitters, length of splitters, absorptive material density, and porosity of a perforated plate on the performance of the splitter silencers. As the number and length of splitter increases, the acoustic performance significantly increases. Although the increase of density of absorptive material also increase the acoustic performance, a change in the density over a certain level hardly affect it. The increase of porosity will enhance the performance especially at higher frequencies.

Defect Shape Recovering by Parameter Estimation Arising in Eddy Current Testing

  • Kojima, Fumio
    • 비파괴검사학회지
    • /
    • 제23권6호
    • /
    • pp.622-634
    • /
    • 2003
  • This paper is concerned with a computational method for recovering a crack shape of steam generator tubes of nuclear plants. Problems on the shape identification are discussed arising in the characterization of a structural defect in a conductor using data of eddy current inspection. A surface defect on the generator tube ran be detected as a probe impedance trajectory by scanning a pancake type coil. First, a mathematical model of the inspection process is derived from the Maxwell's equation. Second, the input and output relation is given by the approximate model by virtue of the hybrid use of the finite element and boundary element method. In that model, the crack shape is characterized by the unknown coefficients of the B-spline function which approximates the crack shape geometry. Finally, a parameter estimation technique is proposed for recovering the crack shape using data from the probe coil. The computational experiments were successfully tested with the laboratory data.

3-ring 임피던스미터의 유체 전기 전도도 독립성에 대한 실험적 연구 (Experimental Study of Characteristics of Three-Ring Impedance Meter and Dependence of Characteristics on Electric Conductivity of Fluids)

  • 김종록;안예찬;김무환
    • 대한기계학회논문집B
    • /
    • 제34권11호
    • /
    • pp.1027-1033
    • /
    • 2010
  • 2상유동(기체-액체) 현상은 전자기발전, 원자력발전, 철강산업 등 유체 시스템에 자주 나타나는 현상으로, 2상유동을 파악하는 것은 유체 시스템의 안정성 및 성능을 위해 중요하다. 2상유동 특성 중 기공률은 압력강하와 열전달 성능을 결정하는 주요 인자로서 이를 측정하는 기술이 특히 중요하다. 유동의 임피던스를 측정하여 기공률을 산정하는 임피던스법은 전기적 특성을 이용하기 때문에 반응속도가 빨라 실시간 측정이 가능하며, 유동관 벽에 전극을 설치할 경우 유동 교란없이 측정할 수 있는 장점이 있다. Coney는 원형관에 적용할 수 있는 ring 임피던스미터를 이론적 연구하였다. 본 연구에서는 Coney가 이론적으로 제안하고 실험적으로 검증하지 못한 3-ring 임피던스미터의 유체 전기전도도에 대한 독립성을 실험적으로 검증하였다.

압전감쇠를 통한 압전단일패널의 전달 소음저감성능 (Transmitted Noise Reduction Performance of Piezoelectric Single Panel through Piezo-damping)

  • 이중근;김재환;김기선;이형식
    • 한국산학기술학회논문지
    • /
    • 제2권2호
    • /
    • pp.49-56
    • /
    • 2001
  • 저주파공진에서의 소음저감을 위한 압전단일패널에 대한 실험적 연구를 수행하였다. 압전단일패널은 압전재료를 평판 구조물에 부착하고, 션트회로를 압전재료에 연결한 구조물이다. 구조물의 저주파공진에서의 전달 소음저감을 위하여 압전감쇠를 이용하였다. 압전감쇠의 파라메터 튜닝은 제안한 새로운 방법을 적용하였다. 이 방법은 전기적 임피던스모델을 기초로 하여 공진회로에서 에너지 소산이 최대가 되도록 하는 방법으로 구조물에 부착된 압전재료에서 전기적 임피던스를 측정하여 시스템의 공진주파수 근처에서 등가 전기 회로를 구성하였다. 압전감쇠를 위한 공진션트 회로는 직렬로 연결된 저항과 인덕터로 구성되었으며, 저항과 인덕터는 회로에서 소산되는 에너지가 최대가 될 수 있는 값으로 최적설계 하였다. 압전단일패널의 전달 소음저감성능은 음향터널을 이용하여 실험을 수행하였다. 음향터널은 사각단면이며 소음 원으로 터널의 한 쪽 끝에 스피커가 설치되었다. 패널은 터널의 중앙에 설치하여 투과 음압을 측정하였다. 압전감쇠를 통하여, 공진주파수에서의 좋은 소음 저감을 얻었다. 압전감쇠를 이용한 압전단일패널은 간단하고 경계적인 측면에서 소음 저감을 위한 유망한 기술이다.

  • PDF

고밀도 폴리에스터 흡음재를 이용한 이중층 흡음시스템의 음향특성 및 흡음성능 향상 방안에 관한 연구 (A Study on the Acoustic Characteristics and Absorption Performance Improvement Method of Double Layered Sound Absorption System Using High Density Polyester Absorbing Materials)

  • 윤제원;장강석;조용성
    • 한국소음진동공학회논문집
    • /
    • 제26권3호
    • /
    • pp.331-339
    • /
    • 2016
  • To improve the acoustic performance of sound absorbing materials, the thickness of the material should be increased or the sound absorbing material having an irregular surface shape should be used. In this study, the acoustic characteristics and methods to improve the acoustic performance of a sound absorbing system equipped with double layered polyester sound absorbing materials were investigated. The numerical model was set up and the results obtained from the model were compared with the actual measurement data. And, strategies to improve the acoustic performance of sound absorbing systems with double layered sound absorbing materials made of polyester with different configuration were shown. So, this study is expected to be usefully used at sites that require high acoustic absorption performance with minimal installation thickness to reduce sounds reflection in narrow spaces such as interior of subway tunnels or in noise barriers installed adjacent to rails.

헬름홀쯔 공명기에서 외부로의 누출 (External Leakage on Helmholtz Resonators)

  • 이일재
    • 한국소음진동공학회논문집
    • /
    • 제23권8호
    • /
    • pp.752-758
    • /
    • 2013
  • The effect of external leakage on the acoustic performance of Helmholtz resonators is experimentally and numerically investigated. The transmission loss of the Helmholtz resonator with a circular perforated hole is measured by using an impedance tube setup. The experimental results are then compared with one-dimensional analytical and three-dimensional numerical results. As the size of the hole increases, the peak of the transmission loss shifts to higher frequency, especially for the holes on the cavity. While the transmission loss is almost independent of the location of the hole on the cavity, the impact of the hole location on the neck on the transmission loss is not negligible. The results show that one-dimensional analytical method can predict the overall trends, whereas three-dimensional numerical method is necessary for more accurate predictions.