Proceedings of the Acoustical Society of Korea Conference (한국음향학회:학술대회논문집)
- 1994.06a
- /
- Pages.704-709
- /
- 1994
INSERTION LOSS MEASUREMENT OF SILENCERS BY DOUBLE PAIR MICROPHONE TECHNIQUE
- Jung, S.S. (Department of Physics, Hankuk University of Foreign Studies) ;
- Pu, Y.C. (Department of Physics, Hankuk University of Foreign Studies) ;
- Kim, M.G. (Department of Physics, Hankuk University of Foreign Studies)
- Published : 1994.06.01
Abstract
The insertion loss is the measured change in power flux at a specified receiver, when the acoustic transmission path between it and the source is modified by the insertion of silencer element. Such measurements have clear and valid physical meaning particularly if the source impedance remains while the transmission path is altered. When the invarient condition is satisfied, the insertion loss is given by the ratio of the acoustic pressure in upstream to that in downstream of the silencer, and that of the particle velocity. The measurement is consisted of using an adaptation of the two microphone method to obtain the complex amplitude of the sound in upstream tube as well as in downstream tube of the silencer. Examples of the data, reduced and presented in terms of the pressure ratio and particle speed ratio, are compared with the theoretical calculations.
Keywords