• Title/Summary/Keyword: Impedance ratio(K)

Search Result 372, Processing Time 0.024 seconds

High-Performance Dual-Circularly Polarized Reflector Antenna Feed

  • Lim, Joo-Young;Nyambayar, Jargalsaikhan;Yun, Je-Young;Kim, Dong-Hyun;Kim, Tae-Hyung;Ahn, Bierng-Chearl;Bang, Jae-Hoon
    • ETRI Journal
    • /
    • v.36 no.6
    • /
    • pp.889-893
    • /
    • 2014
  • This paper presents a high-performance dual-circularly polarized feed employing a dielectric-filled circular waveguide. Novel features are incorporated in the proposed feed, such as a dielectric rod radiator for high gain and good impedance matching; dual quarter-wave chokes for low axial ratio over wide angles and for low back radiation; an integrated septum polarizer; and two end-launch-type coaxial-to-waveguide transitions. The proposed feed shows excellent performance at 5.0 GHz to 5.2 GHz.

Humidity sensing properties of carbon nitride film according to fabrication conditions (제조 조건에 따른 질화탄소막의 습도 감지 특성)

  • Lee, Sung-Pil;Kim, Jung-Hoon;Lee, Hyo-Ung;Lee, Ji-Gong
    • Journal of Sensor Science and Technology
    • /
    • v.14 no.5
    • /
    • pp.343-349
    • /
    • 2005
  • Carbon nitride films were deposited on various substrates for humidity sensors with meshed electrode by reactive RF magnetron sputtering system. As the ratio of injected nitrogen was decreased, the sensitivity of sensor was increased. When the ratio of injected nitrogen was $50{\sim}70%$, the sample showed the best linearity. The sensor impedance changed from $95.4{\;}k{\Omega}$ to $2.1{\;}k{\Omega}$ in a relative humidity range of 5 % to 95 %. The humidity sensors based on silicon wafer revealed higher lineality and faster response than those of alumina or quartz substrates. The adsorption saturation time of the sample was about 80 sec, and its desorption time was about 90 sec.

On the Energy Conversion Efficiency of Piezoelectric Vibration Energy Harvesting Devices (압전 진동 에너지 수확 장치의 에너지 변환 효율에 대한 고찰)

  • Kim, Jae Eun
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.39 no.5
    • /
    • pp.499-505
    • /
    • 2015
  • To properly design and assess a piezoelectric vibration energy harvester, it is necessary to consider the application of an efficiency measure of energy conversion. The energy conversion efficiency is defined in this work as the ratio of the electrical output power to the mechanical input power for a piezoelectric vibration energy harvester with an impedance-matched load resistor. While previous research works employed the electrical output power for approximate impedance-matched load resistance, this work derives an efficiency measure considering optimally matched resistance. The modified efficiency measure is validated by comparing it with finite element analysis results for piezoelectric vibration energy harvesters with three different values of the electro-mechanical coupling coefficient. New findings on the characteristics of energy conversion and conversion efficiency are also provided for the two different impedance matching methods.

Effects of the Sheath on Determination of the Plasma Density of Microwave Probe

  • Kim, Dae-Woong;You, Shin-Jae;Na, Byung-Keun;You, Kwang-Ho;Kim, Jung-Hyung;Chang, Hong-Young
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.02a
    • /
    • pp.181-181
    • /
    • 2012
  • The microwave probe for measuring plasma density is widely used for its advantages: First, it is not affected by the reactive gas. Second, it can measure local plasma parameters such as plasma density, plasma potential and plasma temperature. Third, it is simple and robust. A cut-off probe is the one of the most promising microwave probe. Recently, Kim et al. reveals the physics of the cut-off probe but the effect of the sheath on the determination of the plasma density is not explained. In this presentation, for taking account of sheath effects on determination of plasma density from the cut-off peak, a simplified circuit modeling and an E/M simulation are conducted. The results show that occupation ratio of sheath volume between two tips of the cut-off probe and subsequence pressure condition mainly change position of the cut-off peak with respect to plasma frequency. Magnitude of relative voltage taken on the impedance of sheath and the impedance of bulk plasma can explain this effect. Furthermore, effects of gap size, tip radius, and tip length ware revealed based on above analysis.

  • PDF

Implantable Nerve Cuff Electrode with Conductive Polymer for Improving Recording Signal Quality at Peripheral Nerve (말초 신경 신호 기록의 효율성 개선을 위한 전도성 폴리머가 적용된 생체삽입형 커프형 신경전극)

  • Park, Sung Jin;Lee, Yi Jae;Yun, Kwang-Seok;Kang, Ji Yoon;Lee, Soo Hyun
    • Journal of Sensor Science and Technology
    • /
    • v.24 no.1
    • /
    • pp.22-28
    • /
    • 2015
  • This study demonstrates a polyimide nerve cuff electrode with a conductive polymer for improving recording signal quality at peripheral nerve. The nerve cuff electrodes with platinum (Pt), iridium oxide (IrOx), and poly(3,4-ethylenedioxythiophene): p-toluene sulfonate (PEDOT:pTS) were fabricated and investigated their electrical characteristics for improving recorded nerve signal quality. The fabricated nerve cuff electrodes with Pt, IrOx, and PEDOT:pTS were characterized their impedance and CDC by using electrochemical impedance spectroscopy (EIS) and cyclic voltammetry. The impedance of PEDOT:pTS measured at 1 kHz was $257{\Omega}$, which was extremely lower than the value of the nerve cuff electrodes with IrOx ($15897{\Omega}$) and Pt ($952{\Omega}$), respectively. Furthermore, the charge delivery capacity (CDC) of the nerve cuff electrode with PEDOT:pTS was dramatically increased to 62 times than the nerve cuff electrode with IrOx. In ex-vivo test using extracted sciatic nerve of spaque-dawley rat (SD rat), the PEDOT:pTS group exhibited higher signal-to-interference ratio than IrOx group. These results indicated that the nerve cuff electrode with PEDOT:pTS is promising for effective implantable nerve signal recording.

Relationship between the Body Fat Mass Measured by Bioelectrical Impedance Analysis(BIA) and Dual Energy X-ray Absorptiometry(DEXA), and by the Indices of Insulin Sensitivity (생체 임피던스 방법과 이중 방사선 흡수법으로 측정한 체지방량과 인슐린감수성 지표와의 연관성)

  • Lim, In Seok;Yun, Ki Wook
    • Clinical and Experimental Pediatrics
    • /
    • v.48 no.8
    • /
    • pp.857-864
    • /
    • 2005
  • Purpose : The objectives of this study was to evaluate the correlations between the indices of insulin sensitivity using fasting glucose and insulin level, and the body fat mass measured by bioelectrical impedance analysis(BIA) and dual energy X-ray absorptiometry(DEXA), and to determine the clinical usefulness of insulin sensitivity indices when obese children were followed up. Methods : In this study, 28 simple obese children and adolescents were included. Anthropometric data including body weight, height, obesity degree(OD), body mass index(BMI), and waist-to-hip ratio were collected and then body fat mass was measured by using BIA and DEXA. For metabolic data, 12 hour fasting serum glucose, insulin and lipid profiles were measured and indices for insulin sensitivity(G/I ratio, $log_{insulin}$, HOMA-IR, $log_{HOMA-IR}$, QUICKI) were calculated. Results : BMI had a higher correlation with insulin sensitivity indices than OD(G/I ratio, -0.463 vs -0.209; $log_{insulin}$, 0.417 vs 0.196; HOMA-IR, 0.301 vs 0.238; $log_{HOMA-IR}$, 0.403 vs 0.198; QUICKI, -0.451 vs -0.224). But OD had a higher correlation with body fat mass measured by BIA and DEXA than BMI(BIA, 0.612 vs 0.316; DEXA, 0.667 vs 0.512). The G/I ratio was correlated with body fat mass in BIA(r=-0.420, P<0.05) and DEXA(r=-0.512, P<0.01), percentage of body fat(percentage of fat) in BIA(r=-0.366, P<0.05) and DEXA(r=-0.449, P<0.01). HOMA-IR was only correlated with body fat mass in DEXA(r=0.341, P<0.05). Conclusion : This study revealed that G/I ratios had a statistically significant correlation with anthropometric obesity indices(OD and BMI) and also had a correlation with both body fat mass and percentage of fat. These results suggest that G/I ratios could be used as useful index when obese children and adolescence are followed up.

Properties of Three Kinds of Ferrite/Rubber Composite Microwave Absorbers with Various Composition Ratio (조성비에 따른 3종 페라이트/고무 복합형 전파흡수체의 특성)

  • Ryu, Young-Jun;Jun, Hong-Bae;Kim, Cheol-Han;SaGong, Geon
    • Proceedings of the KIEE Conference
    • /
    • 1999.07d
    • /
    • pp.1680-1682
    • /
    • 1999
  • In this study, three kinds of Mn-Zn ferrite/Ni-Zn ferrite/$Ni_2Y$ ferroxplana prepared by the coprecipitation method were compounded with the silicon rubber, and the ring-shaped specimens with various compositional ratio were made. The material constant of ferrite/rubber composite absorbers was obtained by the 2-port method. The material constants of the ferrite/rubber composite microwave absorber made of three kinds of ferrite with various compositional ratio were utilized in design the matching conditions (frequency and thickness) on the impedance matching map. We were able to predict the matching condition from the matching map. On all three kinds of ferrite/rubber composite microwave absorber with less than compositional ratio 60[wt.%] of ferroxplana, we have found that the reflection losses were over than 20[dB] at the S-Band $(2\sim4[GHz])$ and C-Band$(4\sim8[GHz])$.

  • PDF

Non-Destructive Detection of Hydride Blister in PHWR Pressure Tube Using an Ultrasonic Velocity Ratio Method

  • Cheong Yong-Moo;Lee Dong-Hoon;Kim Sang-Jae;Kim Young-Suk
    • Nuclear Engineering and Technology
    • /
    • v.35 no.5
    • /
    • pp.369-377
    • /
    • 2003
  • Since Zr-2.5Nb pressure tubes have a high risk for the formation of blisters during their operation in pressurized heavy water reactors, there has been a strong incentive to develop a method for the non-destructive detection of blisters grown on the tube surfaces. However, because there is little mismatch in acoustic impedance between the hydride blisters and zirconium matrix, it is not easy to distinguish the boundary between the blister and zirconium matrix with conventional ultrasonic methods. This study has focused on the development of a special ultrasonic method, so called ultrasonic velocity ratio method for a reliable detection of blisters formed on Zr-2.5Nb pressure tubes. Hydride blisters were grown on the outer surface of the Zr-2.5Nb pressure tube using a cold finger attached to a steady state thermal diffusion equipment. To maximize a difference in the ultrasonic velocity in hydride blisters and the zirconium matrix, the ultrasonic velocity ratio of longitudinal wave to shear wave, $V_L/V_S$, has been determined based on the flight time of the longitudinal echo and reflected shear echo from the outer surface of the tubes. The feasibility of the ultrasonic velocity ratio method is confirmed by comparing the contour plots reproduced by this method with those of the blisters grown on the Zr-2.5Nb pressure tubes.

Output Characteristics of Parallel or Serially Connected Helical Magneto-Cumulative Generators (병렬 또는 직렬로 결합한 나선형 자장압축발전기의 출력특성 분석)

  • Kuk Jeong-Hyeon;Lee Heung-Ho
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.53 no.11
    • /
    • pp.647-657
    • /
    • 2004
  • Helical magneto-cumulative generator(HMCG)s are very useful devices in suppling pulsed high current to inductance loads. To apply fast high voltage pulses to high impedance loads, high current outputs of HMCGs are required to be conditioned to higher voltages by using various pulse components such as opening/closing switches and pulse transformer. In this paper, stepping with the trends of requirements for ever-increasing energy in pulsed power applications coupling methods is investigated to obtain higher output energy by connecting several HMCGs in series or parallel way. The coil dimension of HMCGs used in series or parallel connections was 50 mm in diameter and 150 mm in length. The coil was fabricated by using enamel-coated copper wire of 1 mm in diameter. The highest energy amplification ratio and peak voltage of load were achieved from the serially connected four-barrel HMCG system. They were 68 and 34 kV, respectively, when the initial energy of 0.36 kJ was supplied into that system with the load of 0.4 μH. Within the tested range of inductance ratio, energy amplification ratio was found to be highly dependent on the inductance ratio of serial- and parallel-connected HMCG systems to load, which to be optimal around 500 was turned out. The experimental results showed that the output energy and voltage of load are controlled by connecting HMCGs in series or parallel.

Design of a Dual-Band Loop-Type Ground Antenna Using Lumped-Elements (집중 소자를 사용한 이중 대역 루프형 그라운드 안테나 설계)

  • Lee, Hyung-Jin;Liu, Yang;Lee, Jae-Seok;Kim, Hyung-Hoon;Kim, Hyeong-Dong
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.23 no.5
    • /
    • pp.551-558
    • /
    • 2012
  • This paper presents a dual band loop-type ground antenna using lumped-elements that control the impedance bandwidth and resonant frequency. The dual-band operation of the proposed antenna is realized by inserting an additional resonated loop feed structure into the reference ground antenna. As the proper value of the capacitor and the inductor are chosen, the impedance bandwidth of our antenna with voltage standing wave ratio(VSWR) equal to 3 is 85 MHz and 725 MHz at the 2.45 and 5.5 GHz frequency band, respectively. Its validity is demonstrated via both the computed and measured results. Good antenna patterns and efficiencies are achieved at the dual frequency bands, as well as the physically small antenna element size($10{\times}5mm^2$).