• 제목/요약/키워드: Impedance prediction

검색결과 114건 처리시간 0.024초

Comparing the Whole Body Impedance of the Young and the Elderly using BIMS

  • Kim, J.H.;Kim, S.S.;Kim, S.H.;Baik, S.W.;Jeon, G.R.
    • 센서학회지
    • /
    • 제25권1호
    • /
    • pp.20-26
    • /
    • 2016
  • The bioelectrical impedance (BI) for the young and the elderly was measured using bioelectrical impedance spectroscopy (BIS). First, while applying a current of $600{\mu}A$ to the foot and hand, BI was measured at 50 frequencies ranging from 5 to 1000 kHz. The BI for young subjects was considerably lower than that for old subjects since young subjects have more lean mass (hydration). The prediction marker was 0.74 for young subjects and 0.78 for old subjects. Second, a Cole-Cole diagram was obtained for young subjects and old subjects, indicating the different characteristic frequencies. At 50 kHz, the average phase angle was $7.8^{\circ}$ for young subjects whereas that was $6.1^{\circ}$ for old subjects. Third, BIVA was analyzed for young subjects and old subjects. The vector length was 210.89 [${\Omega}/m$] for young subjects and 326.12 [${\Omega}/m$] for old subjects. At 50 kHz, the resistance (R/H) and the reactance ($X_C/H$) divided by height were 208.94 [${\Omega}/m$] and 28.68 [${\Omega}/m$] for young subject, and 324.33 [${\Omega}/m$] and 34.09 [${\Omega}/m$] for old subjects.

가속도 및 임피던스 신호를 이용한 PSC 거더교의 하이브리드 손상 모니터링 체계 (Hybrid Damage Monitoring Scheme of PSC Girder Bridges using Acceleration and Impedance Signature)

  • 김정태;박재형;홍동수;나원배
    • 대한토목학회논문집
    • /
    • 제28권1A호
    • /
    • pp.135-146
    • /
    • 2008
  • 본 논문에서는 가속도 및 임피던스 신호를 이용하여 프리스트레스트 콘크리트(PSC) 거더교에 적합한 하이브리드 손상 모니터링 체계를 제안하였다. PSC 거더교의 주된 손상유형으로 텐던의 긴장력 감소와 콘크리트 거더의 휨 강성 저하를 고려하였다. 제안된 하이브리드 체계는 손상경보, 손상분류 및 손상평가와 같이 크게 3단계로 구성하였다. 첫 번째 단계에서는 가속도 특성 변화를 모니터링하여 전역적인 손상의 발생을 경보한다. 두 번째 단계에서는 임피던스 특성 변화를 모니터링하여 손상유형이 긴장력 감소인지 휨 강성 저하인지를 분류한다. 세 번째 단계에서는 손상유형에 적합한 손상평가기법을 이용하여 손상의 위치와 크기를 평가한다. 손상유형이 휨 강성 저하인 경우에서는 모드형상기반 손상검색 기법을 적용하였고, 손상유형이 긴장력 감소인 경우에서는 고유진동수기반 긴장력 추정 기법을 적용하였다. 모형 PSC 거더 실험을 통해 제안된 하이브리드 손상모니터링 체계의 유용성을 평가하였다.

Application of VSI-EBG Structure to High-Speed Differential Signals for Wideband Suppression of Common-Mode Noise

  • Kim, Myunghoi;Kim, Sukjin;Bae, Bumhee;Cho, Jonghyun;Kim, Joungho;Kim, Jaehoon;Ahn, Do Seob
    • ETRI Journal
    • /
    • 제35권5호
    • /
    • pp.827-837
    • /
    • 2013
  • In this paper, we present wideband common-mode (CM) noise suppression using a vertical stepped impedance electromagnetic bandgap (VSI-EBG) structure for high-speed differential signals in multilayer printed circuit boards. This technique is an original design that enables us to apply the VSI-EBG structure to differential signals without sacrificing the differential characteristics. In addition, the analytical dispersion equations for the bandgap prediction of the CM propagation in the VSIEBG structure are extracted, and the closed-form expressions for the bandgap cutoff frequencies are derived. Based on the dispersion equations, the effects of the impedance ratio, the EBG patch length, and via inductances on the bandgap of the VSI-EBG structure for differential signals are thoroughly examined. The proposed dispersion equations are verified through agreement with the full-wave simulation results. It is experimentally demonstrated that the proposed VSI-EBG structure for differential signaling suppresses the CM noise in the wideband frequency range without degrading the differential characteristics.

전달행렬법에 의한 다중 다공판 흡음시스템의 흡음계수 예측 (Prediction of the Sound Absorption Coefficient for Multiple Perforated-Plate Sound Absorbing System by Transfer Matrix Method)

  • 허성춘;이동훈;권영필
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2001년도 추계학술대회논문집 II
    • /
    • pp.653-658
    • /
    • 2001
  • In this study, a new practical method of predicting the sound absorption coefficient for multiple perforated-plate sound absorbing system was developed using transfer matrix method. In order to validate the proposed method, the absorption coefficients calculated by transfer matrix method for single perforated plate were first compared with the absorption coefficients measured by SWR method according to different porosity, hole diameter, and thickness of the perforated plate. Based on the comparison results, transfer matrix method was further applied to double and triple perforated plates to evaluate the absorption coefficients. The experimental results showed that the absorption coefficients from transfer matrix method generally agreed well with the corresponding absorption coefficients from SWR method. However, due to the limitations of the impedance model used in this study, the measured values were differed with the calculated values for small porosity, hole diameter, and thickness in size of the perforated plate indicating the need of impedance model development for multiple perforated-plate sound absorbing system covering wide ranges of porosity, hole diameter, and thickness of the perforated plate.

  • PDF

차동 노이즈 분석을 위한 단상 인버터 고주파 회로 모델링 및 검증 (Single Phase Inverter High Frequency Circuit Modeling and Verification for Differential Mode Noise Analysis)

  • 신주현;생차야;김우중;차한주
    • 전력전자학회논문지
    • /
    • 제26권3호
    • /
    • pp.176-182
    • /
    • 2021
  • This research proposes a high-frequency circuit that can accurately predict the differential mode noise of single-phase inverters at the circuit design stage. Proposed single-phase inverter high frequency circuit in the work is a form in which harmonic impedance components are added to the basic single-phase inverter circuit configuration. For accurate noise prediction, parasitic components present in each part of the differential noise path were extracted. Impedance was extracted using a network analyzer and Q3D in the measurement range of 150 kHz to 30 MHz. A high-frequency circuit model was completed by applying the measured values. Simulations and experiments were conducted to confirm the validity of the high-frequency circuit. As a result, we were able to predict the resonance point of the differential mode voltage extracted as an experimental value with a high-frequency circuit model within an approximately 10% error. Through this outcome, we could verify that differential mode noise can be accurately predicted using the proposed model of the high-frequency circuit without a separate test bench for noise measurement.

발포 알루미늄 흡음재를 이용한 단순 폐공간의 내부 음장 변화에 관한 연구 (Sound Absorption Effects in a Rectangular Enclosure with the Foamed Aluminum Sheet Absorber)

  • 김상헌;손동구;오재응
    • 한국자동차공학회논문집
    • /
    • 제6권3호
    • /
    • pp.177-186
    • /
    • 1998
  • For the purpose of finding out the sound field characteristics in a cavity of a rectangular enclosure with foamed aluminum lining, analytical and experimental studies are performed with random noise input. Experimental method using two-microphone impedance tube measures the absorption coefficients and the impedances of simple sound absorbing materials. Measured acoustical parameters of the test samples are applied to the theoretical analysis to predict sound pressure field in the cavity. The sound absorp- tion effects from measurements are compared to prediction in both cases with and without foamed aluminum lining in the cavity of the rectangular enclosure.

  • PDF

공명기 분포에 따른 공명기 배열형 패널의 공명주파수 변화 (Resonance frequency shifts of Helmholtz resonator array panel brought by change in resonator arrangements)

  • 김상렬;김양한
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2005년도 추계 학술대회논문집(수송기계편)
    • /
    • pp.97-100
    • /
    • 2005
  • Precise prediction of resonance frequency has been the subject of numerous papers related to Helmholtz resonator design because of its high performance at the frequency. The resonance frequency is dependent upon not only the internal dimensions of resonator but also the external boundary conditions such as the existence of other resonators in Helmholtz resonator array panel. However, the latter effect, which changes the external end correction of resonator, has not been well studied. We propose a formula to calculate the radiation impedance (or external end correction) of Helmhoitz resonator array panel. Any distance between adjacent resonators and any angle of Incidence can be allowed in the method. Numerical examples show how and how much the distance affects the resonance frequency of the panel. It is also found that the maximum absorption of the panel varies with the resonator arrangement.

  • PDF

시변하는 간단한 유체기계의 덕트 내 음원 특성에 대한 해석적 연구 (On the in-duct acoustical source characteristics of a simplified time-varying fluid machine)

  • 이정권;장승호
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2001년도 추계학술대회논문집 I
    • /
    • pp.517-521
    • /
    • 2001
  • Measurement techniques for the in-duct source characteristics of fluid machines can be classified into direct method and load method, according to whether the technique employs an external acoustic source or not. It has been known that the two methods yield different results and the load method used to come up with a negative source resistance, in spite of the fact that a very accurate prediction of radiated noise can be obtained by using any result. This paper is focused to the effect of time-varying nature of fluid machines on the output result. For this purpose, a simplified fluid machine consisting of a reservoir, a valve and a pipe is considered as representing a typical linear, periodic, time-varying system and the measurement techniques are simulated by utilizing the Hill equation and its steady-state forced response. In the load method, the source impedance turns out being dependent on the valve impedance at the calculation frequency and the valve and load impedances at other frequencies as well.

  • PDF

한국 여대생의 체지방측정을 통한 측정기기들 간의 비교연구 (Comparison of Instruments for Estimating Body Composition in Korean Female College Student)

  • 장은재;조진남;황종현
    • 한국식품영양과학회지
    • /
    • 제26권3호
    • /
    • pp.514-520
    • /
    • 1997
  • The purpose of this study is to provide the reference data for estimating body composition and developing equations for prediction of percent body fat. This study was designed of two aspects: Comparison of percent body fat measurements between two operators. comparison of percent body fat measurements among four instruments. Percent body fat of college girls(n=71) aged 18-24 was measured by skinfold thickness, near-infratred interactance(Futrex-5000), and bioelectrical impedance analysis (TBF-105, Spectrum II). All measurements were duplicated & measured by two operators. The results are summarized as follows: Percent body fat observed from two operators had no significant difference. There was significant difference from four instruments. However, we found close relation between Skinfold thickness & TBF-105, Spectrum II & Near-infrared interactance. Four instruments have several assumptions and limitations. Therefore, many researches for developing new equations are required for Korean people.

  • PDF

표면 경계조건을 이용한 코러게이트 혼 안테나 특성 해석 (An analysis of characteristics of corrugated horn antenna using surface impedance condition)

  • 엄만석;박광량
    • 한국통신학회논문지
    • /
    • 제21권6호
    • /
    • pp.1587-1595
    • /
    • 1996
  • We obtained the predicted and measured results for the reflection coefficient and radiation pattern of Ka-band (20- GHz) corrugated horn, which is usually used for feeder of reflector antenna for satellite communication, using suface impedance condition. In order to predict the reture losses of corrugated horn, we analyzed propagation constant of hybrid mode in the corrugated waveguide and then obtained the total reflection coefficient using the circuti theory of multi-step transformer. We also got the radiation pattern of corrugated horn with small flare angle, considering the phase deviation and integrate transverse field on aperture. A test model of corrugated horn antenna for Ka-band designed using theory and program displayed performance and the results agree with the theoretical prediction.

  • PDF