• 제목/요약/키워드: Impedance frequency characteristics

검색결과 647건 처리시간 0.027초

주파수 특성을 고려한 송전선 보호용 적분근사거리계전 알고리즘의 최적 적분 계수 결정 (Optimal Solution of integral Coefficients in Distance Relaying Algorithm for T/L Protection considering Frequency Characteristics)

  • 조경래;홍준희;정병태;조정현;박종근
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1994년도 추계학술대회 논문집 학회본부
    • /
    • pp.42-44
    • /
    • 1994
  • This paper presents the method of estimating integral coefficients of new distance relaying algorithm for transmission line protection. The proposed method is based on the differential equation calculates impedance value by approximation of integral term of integro-differential equation which relate voltage with current. As a result, we can determine the integral coefficients in least square error sense in frequency domain and we take into consideration the analog filter characteristics and frequency domain characteristics of the system to be protected. The simulation results showed that these coefficients can be successfully used to obtain impedance value in distance relay.

  • PDF

배전전주용 스테인리스강판 접지전극의 접지 특성분석 (Grounding Characteristics Analysis of the Stainless-steel Plate Grounding Electrode for Distribution Poles)

  • 김경철;이규진;김민성;정지원
    • 조명전기설비학회논문지
    • /
    • 제24권8호
    • /
    • pp.94-100
    • /
    • 2010
  • 접지시스템은 전기설비의 기준 전위점을 확보할뿐만 아니라 낮은 대지저항으로 고장전류나 과도 전류를 흐르게 한다. 접지임피던스는 주파수에 대한 함수로 고장이나 과도전류가 넓은 범위의 주파수 성분을 포함하기 때문에 접지성능을 평가하는데 중요한 역할을 한다. 본 논문에서는 스테인리스강판 접지전극의 접지특성을 파악하기 위하여 3점 전위강하법으로 접지저항, 접지임피던스와 과도접지임피던스를 측정하였다. 측정된 데이터를 이용하여 접지임피던스와 과도접지임피던스의 등가 전달함수 모델은 ARMA 기법으로 모델링 되었고, 규약접지임피던스로 비교하여 평가하였다.

배전계통에 사용되는 봉형 접지전극의 접지 임피던스 특성 분석 (Ground Impedance Characteristics Analysis of a Rod Type Grounding Electrode used for Distribution Systems)

  • 김경철;진성은;이주홍;김유준;최종기;백남웅
    • 조명전기설비학회논문지
    • /
    • 제19권6호
    • /
    • pp.67-74
    • /
    • 2005
  • 접지 시스템은 전기설비의 기준 전위점을 확보할 뿐만 아니라, 대지에 낮은 저항으로 고장 전류를 흐르게 한다. 고장전류는 넓은 범위의 주파수를 포함하기 때문에 접지의 성능을 평가하기 위해선 주파수에 대한 함수로 접지임피던스에 대한 특성의 분석이 필요하다. 본 논문에서는 상용화된 접지봉(매직봉)의 접지임피던스를 0[Hz]에서 100[kHz] 범위까지 측정하였고, 접지임피던스를 회로 모델과 전달함수 모델로 구하여 측정된 값과 비교 검토하였다.

배전계통에 사용되는 동봉 접지전극의 접지 임피던스 특성 분석 (Ground Impedance Characteristics Analysis of a Copper Rod-type Grounding Electrode used for Electric Distribution Systems)

  • 김경철;이주홍;진성은;오정석;박상영;최종기;김유준
    • 조명전기설비학회논문지
    • /
    • 제19권6호
    • /
    • pp.46-51
    • /
    • 2005
  • 접지 시스템은 전기설비의 기준 전위점을 확보할 뿐만 아니라 대지에 낮은 저항으로 고장 전류를 흐르게 한다. 주파수에 대한 함수로 접지임피던스는 고장전류가 넓은 범위의 주파수를 포함하기 때문에 접지 성능을 평가하는데 필요하다. 동봉은 배전계통에서 가장 많이 쓰이는 접지 전극이다. 본 논문에서는 동봉의 접지임피던스를 주파수 60[Hz]에서 100[kHz] 범위까지 측정하였고, 접지임피던스를 회로 모델과 전달함수 모델로 구하여 측정된 값과 비교 검토하였다.

한반도 중부권 지각물질의 구조와 물성 연구(5) : Free impedance와 Step force법을 이용한 수진기의 특성측정 (Structure and Physical Properties of Earth Crust Material in the Middle of Korean Peninsula(5) : Characteristic Measurement of Geophone using Free Impedance and Step Force Method)

  • 유영준;송무영
    • 지질공학
    • /
    • 제4권2호
    • /
    • pp.207-218
    • /
    • 1994
  • 가동 코일형으로 수진기의 고유정수를 free impedance와 step force법에 의해 결정할 수 있다. 전자의 방법으로는 수진기의 고유주파수($f_o$)와 감쇠정수($h_o$)와 motinal impedance로 부터 관성질량(m) 등을, 후자의 방법으로는 감도(G)를 결정하는 것이 바람직하다. 특히 후자의 방법에 의한 측정에서 측정 시스템을 자체의 고유한 장적기에 의한 잠음발생 문제를 보정해야 한다. 이들의 수진기 고유정수로부터 주파수 특성분석, 즉 위상특성과 진폭특성을 분석한 결과, 고유주파수를 경계로하여 수진기가 가속도계와 변위계로 작용함을 알 수 있다.

  • PDF

Development of an Impedance Locus Model for a Protective Relay Dynamic Test with a Digital Simulator

  • Kim, Soo-Nam;Lee, Myoung-Soo;Lee, Jae-Gyu;Rhee, Sang-Bong;Kim, Kyu-Ho
    • Journal of Electrical Engineering and Technology
    • /
    • 제6권2호
    • /
    • pp.167-173
    • /
    • 2011
  • This paper presents a method for the development of the impedance locus to test the dynamic characteristics of protective relays. Specifically, using the proposed method, the impedance locus can comprise three impedance points, and the speed of impedance trajectory can be adjusted by frequency deviation. This paper is divided into two main sections. The first section deals with the configuration of impedance locus with voltage magnitude, total impedance magnitude, and impedance angle. The second section discusses the control of the locus speed with the means of the deviation between two frequencies. The proposed method is applied to two machine equivalent systems with offline simulation (i.e., PSCAD) and real-time simulation (i.e., real-time simulation environment) to demonstrate its effectiveness.

On DC-Side Impedance Frequency Characteristics Analysis and DC Voltage Ripple Prediction under Unbalanced Conditions for MMC-HVDC System Based on Maximum Modulation Index

  • Liu, Yiqi;Chen, Qichao;Li, Ningning;Xie, Bing;Wang, Jianze;Ji, Yanchao
    • Journal of Power Electronics
    • /
    • 제16권1호
    • /
    • pp.319-328
    • /
    • 2016
  • In this study, we first briefly introduce the effect of circulating current control on the modulation signal of a modular multilevel converter (MMC). The maximum modulation index is also theoretically derived. According to the optimal modulation index analysis and the model in the continuous domain, different DC-side output impedance equivalent models of MMC with/without compensating component are derived. The DC-side impedance of MMC inverter station can be regarded as a series xR + yL + zC branch in both cases. The compensating component of the maximum modulation index is also related to the DC equivalent impedance with circulating current control. The frequency characteristic of impedance for MMC, which is observed from its DC side, is analyzed. Finally, this study investigates the prediction of the DC voltage ripple transfer between two-terminal MMC high-voltage direct current systems under unbalanced conditions. The rationality and accuracy of the impedance model are verified through MATLAB/Simulink simulations and experimental results.

점탄성 재료의 동적 특성 측정에 관한 연구 (A Study on the Dynamic Test of Viscoelastic Material)

  • 최현;박건록;김두훈;이상조
    • 소음진동
    • /
    • 제7권6호
    • /
    • pp.937-943
    • /
    • 1997
  • Viscoelastic materials have the characteristics of elasticity and viscosity. Unlike the metals which show negligible damping characteristics, the damping characteristic of viscoelastic materials like rubber mounts is very important in the analysis of the dynamic system. So there has been a great interest in measuring the damping characteristics of the material can be measured. One is the resonant method which loss factor can be measured only in the resonant frequency. The other is the nonresonant method. In this paper, the test procedure and the physical meaning of the impedance method are introduced. The impedance test results, the loss factor by the impedance method, are compared to the results of the resonant method including some recommendations in the experimental setup.

  • PDF

영상면상의 직선형 안테나의 임피이던스 특성 (The Impedance Characteristics of Verical Antennas Over a Finite Image Plane)

  • 양인용;조성호
    • 대한전자공학회논문지
    • /
    • 제3권3호
    • /
    • pp.2-13
    • /
    • 1966
  • 유한영상면에 수직으로 세운 굵은 선형안테나 임피이던스특성이 해석되고 측정되었다. 측정에는 정방형과 도형도체영상면이 이용되었고 주파수는 고정시키고 안테나 길이를 변화시켰다. 급전점과 안테나간의 연결점에서 발생될 수 있고 단말현상에 대하여도 논하였다. 비교적 큰 정방형영상면상의 안테나 임피이던스 측정치와 이론치가 거의 일치한다. 또한 작은 도형영상면상의 안테나 임피이던스는 무한대영상면상의 굵은 안테나 임피이던스 특성과 비슷하다.

  • PDF

Application of Impedance Spectroscopy to Cement-Based Materials: Hydration of Calcium Phosphate Bone Cements

  • Kim, Sung-Moon;Hwang, Jin-Ha
    • 한국세라믹학회지
    • /
    • 제43권3호
    • /
    • pp.156-161
    • /
    • 2006
  • Impedance spectroscopy was applied to the initial hydration of calcium phosphate bone cements in order to investigate the electrical/dielectric properties. Hydration or equivalently setting was monitored as a function of the amount of water and initial powder characteristics. Higher amounts of water produced more open microstructures, leading to higher conductivity and enhanced dielectric constant. The effects of the initial characteristics in the powder were investigated using bone cement powder prepared with and without granulation. Granulated powder exhibited a significant change in resistance and produced a higher dielectric constant than those of conventional powder. Through a simplified modeling, the effects of thickness in reaction products and pore sizes were estimated by the frequency-dependent impedance measurements. Furthermore, impedance spectroscopy was proven to be a highly reliable tool for evaluating the continuous change in pore structure occurring in calcium phosphate bone cements.