• Title/Summary/Keyword: Impedance characteristics

Search Result 1,732, Processing Time 0.034 seconds

Studies on the Impedance-Hymidity Characteristics of $TiO_2$-$V_2O_5$ Humidity Sensor ($TiO_2$-$V_2O_5$ 습도감지소자의 감습특성에 관한 연구)

  • 박재환;박순자
    • Journal of the Korean Ceramic Society
    • /
    • v.27 no.4
    • /
    • pp.529-535
    • /
    • 1990
  • This paper describes the factors which control the impedance-relative humidity characteristics of the TiO2-V2O5 humidity sensor. To obtain the quantitative relationships between impedance and many manufacturing parameters such as V2O5mol%, the sintering time and temperature, various sets of samples are preared and tested. With changing relative hymidity from 20% to 80%, it is measrued that the corresponding capacitance and impedance from the semicircles which complex impedance plots make. As a result we found that the impedance-relative humidity characteristics are mainly controlled by the doping amount of V2O5 total pore volume and bulk resistence of the elements. We can assume the equivalent circuits of each samples and finally control the sintering time to get a linear humidity impedance response curve which plays an important role in device making. 4mol% V2O5-TiO2 specimen sintered at 90$0^{\circ}C$ for 10min. show liear log(Z) vs. RH characteristics and 10mol% V2O5-TiO2 specimen sintered at the same temp. for 20min. show linear (Z) vs. RH.

  • PDF

A Study on Improving Impedance Characteristics of Planar Monopole Antenna with Vertical Ground Plane (수직 접지면을 갖는 평판형 모노폴 안테나의 임피던스 특성 개선에 관한 연구)

  • Jung, Jin-Woo;Lee, Hyeon-Jin;Lim, Yeong-Seog
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.48 no.5
    • /
    • pp.54-63
    • /
    • 2011
  • This paper presents the improving impedance charactersitics of a planar monopole antenna with a vertical ground plane. For improving impedance characteristics, we used the effect of a vertical ground plane. To analyze the effect of vertical ground plane, we proposed the dipole antenna mode. the impedance characteristics of planar monopole antenna are improved by correlation between monopole antenna and vertical ground plane, based on each operating mode. Our analysis indicates can improve the impedance characteristics of varying planae monopole antennas.

A Design of Homopolar Generator System Considering Instability with Negative Characteristics Load (부성부하와의 발진을 고려한 단극발전기 시스템 설계)

  • Kim, In-Soo;Seong, Se-Jin
    • Proceedings of the KIPE Conference
    • /
    • 2008.06a
    • /
    • pp.449-451
    • /
    • 2008
  • This paper studies the instability between homopolar generator and constant power load with negative impedance characteristics, provides the design method of homopolar generator system which overcomes the instability. In case of magnitude and phase of impedance of source and load mismatch, control instability of source can occur. For the safety of phase of load impedance, the gain of P, I controller with sufficient phase margin is applied through analysis on the simulation model of generator system, and the gain limit of load impedance is ensured by limitation of the gain margin of generator system. The stability of power system can be increased by considering and analyzing the impedance of source and load.

  • PDF

Impedance Matching Characteristic Research Utilizing L-type Matching Network

  • Jun Gyu Ha;Bo Keun Kim;Dae Sik Junn
    • Journal of the Semiconductor & Display Technology
    • /
    • v.22 no.2
    • /
    • pp.64-71
    • /
    • 2023
  • If an impedance mismatch occurs between the source and load in a Radio Frequency transmission system, reflected power is generated. This results in incomplete power transmission and the generation of Reflected Power, which returns to the Radio Frequency generator. To minimize this Reflected Power, Impedance matching is performed. Fast and efficient Impedance matching, along with converging reflected power towards zero, is advantageous for achieving desired plasma characteristics in semiconductor processes. This paper explores Impedance matching by adjusting the Vacuum Variable Capacitor of an L-type Matching Module based on the trends observed in the voltage of the Phase Sensor and Electromotive Force voltage. After assessing the impedance matching characteristics, the findings are described.

  • PDF

Characteristics of Grounding Impedances of Carbon Compound Grounding Electrodes (탄소혼합물 접지전극의 접지임피던스의 특성)

  • Lee, Kang-Soo;Lee, Bok-Hee
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.25 no.5
    • /
    • pp.54-60
    • /
    • 2011
  • This paper presents characteristics of frequency-dependent grounding impedance and transient grounding impedance for the carbon compound grounding electrode used in the installation of computerized electronic equipment and lightning protection system. The frequency-dependent grounding impedances were measured by applying sinusoidal currents in the frequency range from 100 [Hz] to 10[MHz], and the transient grounding impedances were examined by subjecting the impulse current with the front-time between 1~80[${\mu}s$]. As a result, the ground resistance of the carbon compound grounding electrode is less than that of another type grounding electrodes. The transient grounding impedance is relatively low and the conventional grounding impedance is rather lower than the ground resistance. The frequency-dependent grounding impedance of the carbon compound grounding electrode is capacitive and the grounding impedance is decreased with increasing the frequency of injected currents. Therefore in the case that the carbon compound grounding electrode is jointly used with large-scaled grounding electrodes, it is possible to reduce the high frequency grounding impedance of the integrated grounding electrode system.

Impedance Characteristics of Blue Fluorescent OLED According to Elapsed Time (경과 시간에 따른 청색 형광 OLED의 Impedance 특성)

  • Kong, Do-Hoon;Yang, Jae-Woong;Ju, Sung-Hoo
    • Journal of the Korean institute of surface engineering
    • /
    • v.50 no.5
    • /
    • pp.405-410
    • /
    • 2017
  • In order to study current-voltage-luminance and impedance characteristics according to elapsed time, a blue fluorescent OLED was fabricated. The current density and luminance gradually decreased in accordance with elapsed time and did not emit light after 480 hours, and the threshold voltage increased as time elapsed. The Cole-Cole plot was a semicircular shape of a very large size at 2 V of the applied voltage below the threshold voltage, and the maximum value of the real number impedance did not change greatly from 9314.5 to $9902.2{\Omega}$ as time elapsed. Applied voltages 4, 6, and 8 V above the threshold voltage showed a large change in the real number impedance value at the semicircle end to 9,678.2, 9,826, $9,535.4{\Omega}$ according to the elapsed time from 2,222.5, 183.7, $48.2{\Omega}$ immediately after fabricating the device. By increasing the applied voltage beyond the threshold voltage just after device fabrication, the energy difference between the device and the organic layer was overcome and the current flowed, the maximum value of the real number impedance sharply decreased. As time passed, current did not flow through the element even at high applied voltage due to degradation of the element, and even when the applied voltage was higher than the threshold voltage, it showed an impedance value such as applied voltage equal to or less than the threshold voltage. As a result, it can be learned that the change in the impedance with elapsed time reflects the characteristics due to the degradation of the OLED and can predict the characteristics and lifetime of the OLED.

Effective Impulse Impedances of Deeply Driven Grounding Electrodes

  • Lee, Bok-Hee;Jeong, Dong-Cheol;Lee, Su-Bong;Chang, Keun-Chul
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • v.4C no.5
    • /
    • pp.207-214
    • /
    • 2004
  • This paper presents the characteristics of transient and effective impulse impedances for deeply driven grounding electrodes used in soil with high resistivity or in downtown areas. The laboratory test associated with the time domain performance of grounding piles subjected to a lightning stroke current has been carried out using an actual-sized model grounding system. The ground impedances of the deeply driven ground rods and grounding pile under impulse currents showed inductive characteristics, and the effective impulse ground impedance owing to the inductive component is higher than the power frequency ground impedance. Both power frequency ground impedance and effective impulse ground impedance decrease upon increasing the length of the model grounding electrodes. Furthermore, the effective impulse ground impedances of the deeply driven grounding electrodes are significantly amplified in impulse currents with a rapid rise time. The reduction of the power frequency ground impedance is decisive to improve the impulse impedance characteristics of grounding systems.

Impedance Characteristics of Fluorescent OLED with Device Structure (소자 구조에 따른 형광 OLED의 Impedance 특성)

  • Kong, Do-Hoon;Ju, Sung-Hoo
    • Korean Journal of Materials Research
    • /
    • v.28 no.1
    • /
    • pp.18-23
    • /
    • 2018
  • To study the impedance characteristics of a fluorescent OLED according to the device structure, we fabricated Device 1 using ITO / NPB / $Alq_3$ / Liq / Al, Device 2 using ITO / 2-TNATA / NPB / $Alq_3$ / Liq / Al, and Device 3 using ITO / 2-TNATA / NPB / SH-1:BD / $Alq_3$ / Liq / Al. The current density and luminance decreased with an increasing number of layers of the organic thin films in the order of Device 1, 2, 3, whereas the current efficiency increased. From the Cole-Cole plot at a driving voltage of 6 V, the maximum impedance values of Devices 1, 2, and 3 were respectively 51, 108, and $160{\Omega}$ just after device fabrication. An increase in the impedance maximum value is a phenomenon caused by the charge mobility and the resistance between interfaces. With the elapse of time after the device fabrication, the shape of the Cole-Cole plot changed to a form similar to 0 or a lower voltage due to the degradation of the device. As a result, we were able to see that an impedance change in an OLED reflects the characteristics of the degradation and the layer.

Grounding Characteristics Analysis of the Stainless-steel Plate Grounding Electrode for Distribution Poles (배전전주용 스테인리스강판 접지전극의 접지 특성분석)

  • Kim, Kyung-Chul;Lee, Kyu-Jin;Kim, Min-Sung;Jung, Ji-Won
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.8
    • /
    • pp.94-100
    • /
    • 2010
  • Grounding system insures a reference potential point for electric devices and also provides a low impedance path for fault currents or transient currents in the earth. The ground impedance as function of frequency is necessary for determining its performance since fault currents could contain a wide range of frequencies. In this paper, the grounding resistance, grounding impedance and transient grounding impedance are measured by using 3-point fall-of-potential method in order to analyse grounding characteristics of the stainless-steel plate grounding electrode. An equivalent transfer function model of the grounding impedance and transient grounding impedance are identified from the measured values by using ARMA method and evaluated by comparing conventional grounding impedances.

Impedance Characteristics of operate fluid about Frictional loss in seamless pipeline (SEAMLESS 관의 마찰손실에 따른 작동유체의 임피던스 특성)

  • 모양우;유영태;최병재
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 2001.10a
    • /
    • pp.304-310
    • /
    • 2001
  • Flow pulsation often causes vibration and noise in piping systems and therefore has been a troublesome concern for fluid system engineers. According to frequency increase in this paper under the influence wave form of velocity in springly flow and viscosity are drop coefficient of viscosity become increase so that impedance and resistance. The transient variations of flow rate are measured by a modified impedance tube method which is realized by virtue of the present analytical technique. At pipe line in order to eliminate vibration, confirm happened intermittently impedance characteristics. We make a test and frequency analysis and have to minimize obstructive component at hydraulic circuit.

  • PDF