• Title/Summary/Keyword: Impact level criteria

Search Result 180, Processing Time 0.024 seconds

Decision Making of Improvement Priority by Deterioration Risk Assessment of Water Supply Infrastructures (물공급시설의 노후 위험도 평가를 통한 개선 우선순위 결정)

  • Chae, Soo-Kwon;Lee, Dae-Jong;Kim, Ju-Hwan
    • Journal of Environmental Impact Assessment
    • /
    • v.18 no.6
    • /
    • pp.367-376
    • /
    • 2009
  • This paper proposes an application methodology of AHP(Analytic Hierarchy Process) based decision making theory for improvement priority by assessment of various risk factors affecting on deterioration of water supply systems, as major social infrastructure. AHP method is organized with three level of hierarchy which is introduced for multi-criteria decision making in this study. In the first level, assessment outputs are calculated by AHP for each affecting factor. In the second level, criteria are estimated by using assessment results with respect to structural and environmental factors. Consequently, ranking decision is performed in the third level. In order to present the effectiveness, a proposed method is compared with FCP(Fuzzy Composite Programming) for decision making. Since the results of the proposed method show better performance with consistent results, it can be applied as an efficient information for the determination for improvement priority of the study infrastructure.

Assessment on Stabilization of Open-dumping Landfill Gas - A Case Study of Salmi Landfill - (사용종료된 비위생매립지의 매립가스 안정화 평가 - 살미매립지 사례연구 -)

  • Hong, Sang-Pyo;Kim, Kwang-Yul
    • Journal of Environmental Impact Assessment
    • /
    • v.14 no.6
    • /
    • pp.365-375
    • /
    • 2005
  • For managing and utilizing a closed municipal solid waste landfill site in environmentally secure conditions, it is necessary to verify the stabilization level of landfill gas(LFG) and waste. For assessing LFG and waste stabilization of an open-dumping municipal solid waste landfill (Salmi Landfill) which is located at the vicinity of Chungju Reservoir which flows into Paldang Reservoir that has been used for Seoul Metropolitan water supplies, the history and the surrounding characteristics of the landfill site were surveyed. In this study, waste and LFG samples obtained from landfill site were physically and chemically analyzed, and then the analysis results were evaluated on the basis of 'The Criteria of Landfill Waste Stabilization(CLWS)' that were promulgated by Korean Ministry of Environment. Based on LFG composition of Salmi landfill, $CH_4$ was as high as 68%. In CLWS regulation, the stabilization criteria of $CH_4$ should be lower than 5%, and the criteria of C/N ratio should also be lower than 1/10. The result showed that C/N ratio of landfilled waste ranged 17.4~24.7. From this results, it was concluded that the LFG and C/N ratio stabilization level of this landfill based on the CLWS were still actively proceeding.

A Study of Rating Method Comparison for Heavy-weight Floor Impact Sound based on the Field Test Data in Apartment Houses (공동주택 중량바닥충격음 현장측정을 통한 차단성능 평가방법의 비교검토 연구)

  • Shin, Hoon;Back, Geon Jong;Kook, Chan;Song, Min Jeon;Kim, Sun Woo
    • KIEAE Journal
    • /
    • v.10 no.5
    • /
    • pp.187-194
    • /
    • 2010
  • Heavy-weight floor impact sound insulation performance criteria have been effective in Korea since the regulation which enforces the standard thickness of slabs in domestic apartment houses should be constructed by 180mm or 210mm was adopted. But every slab does not satisfy this criteria. So, review on existing floor impact sound insulation performance is needed to propose some basic materials for the revision of rating method. To achieve this goal, 63 field test data were checked and analyzed. The results of this study are as follows ; 1) The 210mm thickness slab has the characteristics of deeper level decrease above 120Hz frequency band than that of 180mm thickness slab's. 2) 27.5% of 180mm thickness slabs were satisfied the floor impact sound insulation performance criteria, whereas 65% of 210mm slabs do. 3) Among the main contribution frequency bands for the determination of single rating index, 63Hz was shown as the most contributive band in 210mm slabs. 4) In comparison of single rating index between bang machine test and ball test. there is a big difference between the two and this phenomenon is frequent in 210mm slab results. 5) Rating Methods for the analysis of cross-correlation between the amount of rating, the usefulness of the arithmetic mean could be secured.

Impact of nonphysician, technology-guided alert level selection on rates of appropriate trauma triage in the United States: a before and after study

  • Megan E. Harrigan;Pamela A. Boremski;Bryan R. Collier;Allison N. Tegge;Jacob R. Gillen
    • Journal of Trauma and Injury
    • /
    • v.36 no.3
    • /
    • pp.231-241
    • /
    • 2023
  • Purpose: Overtriage and undertriage rates are critical metrics in trauma, influenced by both trauma team activation (TTA) criteria and compliance with these criteria. Analysis of undertriaged patients at a level I trauma center revealed suboptimal compliance with existing criteria. This study assessed triage patterns after implementing compliance-focused process interventions. Methods: A physician-driven, free-text alert system was modified to a nonphysician, hospital dispatcher-guided system. The latter employed dropdown menus to maximize compliance with criteria. The preintervention period included patients who presented between May 12, 2020, and December 31, 2020. The postintervention period incorporated patients who presented from May 12, 2021, through December 31, 2021. We evaluated appropriate triage, overtriage, and undertriage using the Standardized Trauma Assessment Tool. Statistical analyses were conducted with an α level of 0.05. Results: The new system was associated with improved compliance with existing TTA criteria (from 70.3% to 79.3%, P=0.023) and decreased undertriage (from 6.0% to 3.2%, P=0.002) at the expense of increasing overtriage (from 46.6% to 57.4%, P<0.001), ultimately decreasing the appropriate triage rate (from 78.4% to 74.6%, P=0.007). Conclusions: This study assessed a workflow change designed to improve compliance with TTA criteria. Improved compliance decreased undertriage to below the target threshold of 5%, albeit at the expense of increased overtriage. The decrease in appropriate triage despite compliance improvements suggests that the current criteria at this institution are not adequately tailored to optimally balance the minimization of undertriage and overtriage. This finding underscores the importance of improved compliance in evaluating the efficacy of TTA criteria.

Assessment on Stabilization of Open-dumping Landfill Based on Leachate - A Case Study of Salmi Landfill - (침출수 특성 분석을 통한 사용종료 비위생매립지 안정화 평가 - 살미매립지 사례연구 -)

  • Hong, Sang-Pyo;Kim, Kwang-Yul
    • Journal of Environmental Impact Assessment
    • /
    • v.15 no.5
    • /
    • pp.299-308
    • /
    • 2006
  • To utilize a closed municipal solid waste landfill site in environmentally secure conditions, it is necessary to verify the stabilization level of landfill leachate. To assess leachate stabilization of an open-dumping municipal solid waste landfill site (Salmi Landfill) which is located at the vicinity of Chungju Reservoir which flows into Paldang Reservoir utilized as Seoul Metropolitan water supplies, the landfill history and surrounding characteristics of the landfill site were surveyed. In this investigation, waste, leachate, groundwater and surfacewater samples from this landfill were physically and chemically analyzed, and the analysis results were evaluated by 'The Criteria of Landfill Waste Stabilization (CLWS)', 'Discharge Criteria of Landfill Leachate', 'The Criteria of Domestic Use in Groundwater Quality', and 'The Criteria of Domestic Use in Surfacewater Quality' that promulgated by Korean Ministry of Environment. From the analysis results on the Salmi open-dumping landfill, C/N ratio was 18.9 and $BOD/COD_{Cr}$ ratios in leachate were higher than 1/10. Based on the CLWS, this results seemed to imply that the process of leachate stabilization at this landfill was still proceeding.

Scuba Diver's Use of Selection Criteria for Assessing Wetsuit Using FEA Model

  • Michaelson, Dawn;Kim, Dong-Eun;Ha, Young
    • International Journal of Costume and Fashion
    • /
    • v.18 no.2
    • /
    • pp.45-64
    • /
    • 2018
  • This study assessed scuba divers' wetsuit selection criteria based on the gender, age and scuba diving commitment level along with identifying currently owned and preferred wetsuit types. Lamb and Kallal's Functional, Expressive, and Aesthetic Consumer Needs (FEA) Model was the conceptual framework used for this study. Scuba diving has seen consistent growth, worldwide, it is necessary to investigate with wetsuit needs of this consumer group. A survey of 302 active scuba divers participated in the study. Total participants included 202 male and 100 female scuba divers. Divers stated fit was the most highly rated criteria with don/doff being most problematic. Female and older divers regarded functional performance criterion greatly(p<.05). Highly committed divers regarded the functional quality (p<.01) and aesthetic/expressive features (p<.05) of the wetsuit as important and owned more wetsuits(p<.01). Gender saw differences in required sizes ranges(p<.001) and style preferences(p<.05). Results suggest gender, age, and commitment levels all impact the wetsuit selection criteria of scuba divers.

A Study on the Quantification of Information Security Level (정보보안수준 계량화 연구)

  • Kim, Hyun-Soo
    • Asia pacific journal of information systems
    • /
    • v.9 no.4
    • /
    • pp.181-201
    • /
    • 1999
  • This study presents an information security level index and a quantification scheme. A comprehensive survey on previous researches in information security checklists has been performed. A candidate indicator list for information security level has been developed, Desirability of each indicator has been tested by 4 criteria, They are general validity, relative importance, probability of accident and impact of accident. 67 experts' opinion has been collected and analysed. The result shows that selected indicators are a very good candidate set for the determination of information security level. A factor analysis shows indicators are well structured. There exists strong correlation between validity and probability, validity and impact, and importance and probability. A quantification scheme of information security index has been developed by experts' judgement and statistical tests.

  • PDF

Criteria for multiple noises in residential buildings uslng combined rating system (공동주택 생활소음의 통합 평가등급 설정)

  • Ryu, Jong-Kwan;Lee, Pyoung-Jik;Jeon, Jin-Yong
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2005.05a
    • /
    • pp.367-371
    • /
    • 2005
  • Social noise survey on multiple residential noises such as nut impact, air-borne, bathroom, drainage and traffic noises was conducted to investigate major variables affecting the overall satisfaction for noise environment The effect of individual noise perception on the evaluation of the overall noise environment was investigated through a questionnaire survey on annoyance, disturbance and noise sensitivity. Auditory experiments was also undertaken to determine noise level according to the percent of satisfaction for individual noise source. As a result of survey, it was found that satisfaction for floor impact noise most greatly affects the overall satisfaction for noise environment and annoyance most greatly affects the satisfaction for individual noise sources. Result of auditory experiment showed that the noise level of floor impact noise by bang machine, airborne, drainage and traffic noise corresponding to 50% satisfaction is 44dB($L_{i,Fmax,AW}$) and 40dBA, respectively.

  • PDF

Noise Test of High-speed Train at 300km/h (경부고속철도 300km/h 주행시 소음 평가)

  • 나희승;김준엽
    • Proceedings of the KSR Conference
    • /
    • 2002.05a
    • /
    • pp.452-457
    • /
    • 2002
  • High speed railroad noise is one of the main causes of environmental impact. An estimate of the relevant noise levels is usually required in order to evaluate the noise barrier and the anti-noise trailer. This paper introduce the test procedure and the estimate for HST noise. The aim of this is to measure, by means of a test, the level of acoustic pressure present during the passing of a KTX(Korea Train Express), in order to satisfy the contractual requirements and the noise criteria. A number of measurements are carried out in order to estimate noise impact by HST along test track.

  • PDF

Evaluation of Track Impact Factor in the Conventional Line (기존선 궤도의 충격계수 산정에 관한 연구)

  • 엄주환;유영화;엄기영
    • Journal of the Korean Society for Railway
    • /
    • v.6 no.4
    • /
    • pp.239-245
    • /
    • 2003
  • In this paper, the track impact factor of conventional line was evaluated using the data for wheel load measured in field and the properties of current operating trains. The equation for track impact factor was presented through the statistical analysis of variational ratio in wheel load and compared with other design equations in domestic and foreign countries. A review on the safety of track system in conventional line was made from the relationship between the velocity and the corresponding impact factor. It was found that the impact factor from the proposed equation is a little less than the values from the equations adopted in both AREA and domestic railway, while it is same as the equation for continuous welded rail(CWR) in Japan. Therefore it could be said that the track satisfies a criteria for dynamic load caused by the train and the corresponding level of safety is guaranteed for dynamic load of the train