• Title/Summary/Keyword: Impact echo

Search Result 111, Processing Time 0.027 seconds

충격반향시험에 의한 콘크리트 터널 라이닝 내부결함 및 두께 조사 (Inspection for Internal Flaw and Thickness of Concrete Tunnel Lining Using Impact Echo Test)

  • 김영근;이용호;정한중
    • 터널과지하공간
    • /
    • 제7권3호
    • /
    • pp.230-237
    • /
    • 1997
  • As concrete structure is getting old and decrepit, its inspection and diagnosis is getting important. Therefore, it is necessary to estimate the soundness of structure using non-destructive tests for effective repairs and maintenances. But, applications of non-destructive tests in tunnel have been used restrictively, due to accessibility only from one side in tunnel lining and presence of tunnel installations. Recently, the various non-destructive techniques have been studied. Especially, ground penetrating radar(GPR) and impact echo (IE) methods have been researched for tunnel inspection. In this study, the applicability of impact echo test in tunnel lining inspection has been investigated. This paper described the tunnel inspection for lining thickness and internal flaw using impact echo tests. Model tests were carried out using impact echo test systems on two concrete models, Model I is measuring for lining thickness, Model II is detecting for internal flaw. Also, the test were applied for lining inspections in a tunnel constructed by NATM. From the results of impact echo tests, we have concluded that impact echo test is a very useful and effective technique for inspecting the concrete tunnel linings.

  • PDF

Experimental Investigation of Impact-Echo Method for Concrete Slab Thickness Measurement

  • Popovics John S.;Cetrangolo Gonzalo P.;Jackson Nicole D.
    • 비파괴검사학회지
    • /
    • 제26권6호
    • /
    • pp.427-439
    • /
    • 2006
  • Accurate estimates of in place thickness of early age (3 to 28 days after casting) concrete pavements are needed, where a thickness accuracy of ${\pm}6mm$ is desired. The impact-echo method is a standardized non-destructive technique that has been applied for this task. However, the ability of impact-echo to achieve this precision goal is affected by Vp (measured) and ${\beta}$ (assumed) values that are applied in the computation. A deeper understanding of the effects of these parameters on the accuracy of impact-echo should allow the technique to be improved to meet the desired accuracy goal. In this paper, the results of experimental tests carried out on a range of concrete slabs are reported. Impact-echo thickness estimation errors caused by material property gradients and sensor type are identified. Correction factors to the standard analysis method are proposed to correct the identified errors and to increase the accuracy of the standard method. Results show that improved accuracy can be obtained in the field by applying these recommendations with the standard impact-echo method.

충격반향기법의 신뢰성 향상을 위한 탄성파 파동전파 특성의 연구 (Investigation of the Stress-Wave Propagation In Improve the Reliability of the Impact-Echo Method)

  • 조미라
    • 콘크리트학회논문집
    • /
    • 제14권2호
    • /
    • pp.266-274
    • /
    • 2002
  • 콘크리트 구조물 또는 조적식 구조물을 비파괴적으로 평가하는 충격반향시험은 타 기법과 비교하였을 때, 현장 적용면에서 탁월하게 우수하며, 그 신뢰성도 매우 높게 평가되고 있다 그러나 경우에 따라서 충격반향기법은 낮은 신뢰성을 나타내고 있다. 본 연구에서는 충격반향기법의 신뢰성을 수치해석에 의해 검토하였다. 유한요소해석 및 이론을 근거로 하는 동강성행렬법을 이용하여 균질한 강성구조 깊이에 따라 증가 또는 감소하는 전단강성구조, 샌드위치형 전단강성구조 등 대표적 유형의 전단강성구조를 가지는 콘크리트 터널벽체에 대해 충격반향실험의 수치 모사를 수행하였다. 이를 바탕으로 충격반향기법의 실험자료 분석 및 해석에 있어서 보다 신뢰성 있는 결과 도출을 위한 제언을 하였다.

저비용 음압센서를 이용한 콘크리트 구조물에서의 비접촉 Impact-Echo 기반 손상 탐지 (Non-contact Impact-Echo Based Detection of Damages in Concrete Slabs Using Low Cost Air Pressure Sensors)

  • 김정수;이창준;신성우
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제15권3호
    • /
    • pp.171-177
    • /
    • 2011
  • 본 논문에서는 비접촉식 충격-반향 기법을 이용한 콘크리트 구조물의 손상 탐지에 있어서 비용 효율성을 높이기 위한 다이나믹 마이크로폰의 적용 가능성에 대하여 알아보았다. 박리 손상이 인공적으로 모사된 콘크리트 슬래브 실험체에 대하여 비접촉 충격-반향 실험을 다이나믹 마이크로폰을 이용하여 수행하였으며 저비용 센서 시스템의 손상 탐지 성능을 분석하였다. 실험 결과 다이나믹 마이크로폰으로 의미있는 신호의 측정이 가능하며, 또한 콘크리트의 박리 손상도 고성능 음압 센서만큼 명확하게 검출 가능하다는 것을 알 수 있었다.

충격반향기법을 이용한 국도상 노후교량의 결함검사 (Flaw Detection of the Aged Bridge on National Roadway by Impact Echo Testing)

  • 유재열;김기봉;정영수;조성호
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1998년도 가을 학술발표대회 논문집(III)
    • /
    • pp.743-748
    • /
    • 1998
  • As nation's infrastructure is getting old, nondestructive evaluation of existing structures and construction quality control are getting important. In this thesis, flaw detection techniques of concrete members with asphalt using impact echo test were introduced. This techniques are based on stress wave propagation. In this field impact echo test, As load is gradually increased, frequency is increased. From this change of frequency through impact echo test, we can detect that the crack of bridge ascends and what the depth of crack is.

  • PDF

Accuracy Enhancement of Reflection Signals in Impact Echo Test

  • Lho, Byeong-Cheol
    • 콘크리트학회논문집
    • /
    • 제15권6호
    • /
    • pp.924-929
    • /
    • 2003
  • A majority of infrastructures has been deteriorated over time. Therefore, it is very important to verify the quality of construction, and the level of structural deterioration in existing structures, to ensure their safety and functionality. Many researchers have studied non-destructive testing (NDT) methods to identify structural problems in existing structures. The impact echo technique is one of the widely used NDT techniques. The impact echo technique has several inherent problems, including the difficulties in P-wave velocity evaluation due to inhomogeneous concrete properties, deterioration of evaluation accuracy where multiple reflection boundaries exist, and the influence of the receiver location in evaluating the thickness of the tested structures. Therefore, the objective of this paper is to propose an enhanced impact echo technique that can reduce the aforementioned problems and develop a Virtual Instrument for the application via a thickness evaluation technique which has same technical background to find deterioration in concrete structures. In the proposed impact echo technique, transfer function from dual channel system analysis is used, and coherence is improved to achieve reliable data. Also an averaged signal -ensemble- is used to achieve more reliable results. From the analysis of transfer function, the thickness is effectively identified.

토목공학 분야에서의 충격반향법의 응용 (Application of Impact Echo Method to Civil Engineering Fields)

  • 정연문;하희상
    • 지구물리와물리탐사
    • /
    • 제3권3호
    • /
    • pp.94-100
    • /
    • 2000
  • 금속 물체의 내부 상태를 조사하기 위하여 사용되고 있는 여러 가지 비파괴 조사법들은 콘크리트 재료의 불균질성으로 인하여 콘크리트 물체에의 적용에는 한계가 있다 충격반향법은 물성의 변화가 존재하는 경계면이나 결함 부위에서 반사되는 탄성파의 공진 주파수를 이용하는 비파괴 조사법으로서 콘크리트 구조물의 내부 상태를 파악하기 위하여 활용될 수 있다. 본 연구에서는 충격반향법의 현장 적용을 위한 자료획득 시스템을 구축하였고 여러 가지 조건하에서 현장 시험을 수행하였다. 콘크리트 구조물의 두께 및 결함, 공동 존재 여부, 옹벽 뒷채움 상태와 터널 라이닝의 두께 및 결함, 그리고 활주로의 포장 두께 및 결함등의 조사를 위하여 충격반향법을 적용하였다. $10\%$ 이하의 오차 범위내에서 결과를 제공함으로써 충격반향법의 토목분야에서의 활용 가능성이 입증되었다.

  • PDF

화해된 콘크리트의 잔존 강도 평가에 있어서 충격-반향 기법의 적용성 (Applicability of Impact-Echo Method for Assessment of Residual Strength of Fire-Damaged Concrete)

  • 신성우;김승용;김정수
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제17권5호
    • /
    • pp.105-112
    • /
    • 2013
  • 이 연구에서는 화해된 콘크리트의 잔존 강도 평가에 있어서 충격-반향 기법의 적용성을 알아보고자 하였다. 화해를 모사하기 위해 콘크리트 실험체에 대한 표준 화재 온도 가열 시험을 실시하고, 화해된 콘크리트 실험체에 대해 충격-반향 응답 실험 및 압축 강도 실험을 실시하였다. 화해된 콘크리트의 충격-반향 응답 특성과 압축 강도의 잔존 특성을 분석하였으며, 또한 충격-반향 응답으로부터 구한 초음파 속도와 잔존 압축 강도와의 상관관계를 분석하였다. 연구 결과 화해된 콘크리트의 초음파 속도를 충격-반향 기법으로 신뢰성 있게 계측할 수 있으며, 또한 잔존 강도 평가에 충격-반향 기법을 유효하게 적용 가능하다는 것을 알 수 있었다.

임팩에코 응답신호를 적용한 건설재료 비파괴 압축강도 산정 (Nondestructive Assessment of Compressive Strength of Construction Materials Using Impact-Echo Response Signal)

  • 손무락;김무준
    • 한국지반환경공학회 논문집
    • /
    • 제18권8호
    • /
    • pp.17-21
    • /
    • 2017
  • 본 논문은 암석 및 콘크리트 등의 건설재료의 비파괴 압축강도를 산정하기 위하여 재료타격 시 발생하는 임팩에코 응답신호를 모두 측정하고 이를 누적한 전체 사운드 신호에너지의 이용성에 관해 파악하고 그 결과를 제시하는 것이다. 본 연구에서는 이를 위해서 타격장치를 고안하였고 이를 이용하여 재료를 회전 자유낙하에 의해 초기 타격토록 하고 이후 반발작용에 의한 반복타격이 소멸될 때까지 발생할 수 있도록 하였다. 본 연구에서는 서로 다른 강도를 가지도록 배합된 콘크리트 시편에 대하여 실험을 실시하고 임팩에코 응답신호를 측정하였다. 시편별 산정된 전체 사운드 신호에너지는 직접압축강도시험을 통한 시편별 압축강도와 상호 비교하였다. 비교결과, 임팩에코 응답신호를 통해 산정된 전체 사운드 신호에너지는 시편의 직접압축강도와 직접적인 관계가 있다는 것을 확인하였으며, 이를 통해 암석 및 콘크리트 등의 건설재료의 압축강도는 재료타격 시 발생하는 임팩에코 응답신호로부터 산정된 전체 사운드 신호에너지를 이용하여 비파괴적으로 산정할 수 있음을 알 수 있었다.

Size Estimation of Concrete Structures Using the Impact Echo Method

  • Hong, Seong-Uk;Yoon, Sang-Ki;Lee, Yong-Taeg;Kim, Seung-Hun
    • Architectural research
    • /
    • 제22권1호
    • /
    • pp.23-31
    • /
    • 2020
  • This study aims to verify a method for accurately estimating the sizes of the column, slab, and beam members of concrete structures using the impact echo method, which is a nondestructive testing method. The concrete specimens are designed and fabricated with six single-layer frame specimens composed of columns, slabs, and beam members based on three strengths of 24, 30, and 40 MPa. To estimate the sizes of the members according to the member types of concrete structures, the experiment was performed using the impact echo method. As a result of estimating the sizes of the concrete column members using the impact echo method, the error rate is 2.9%. As a result of estimating the depth of the concrete beam members, the error rate is 9.7%. And, as a result of estimating the thickness of the concrete slab members, the error rate is 2.4%. These results confirmed that quality control of the members of concrete structures is possible by estimating their sizes using a non-destructive testing method.