• Title/Summary/Keyword: Impact damage characteristics

Search Result 294, Processing Time 0.025 seconds

Damage Characteristics of Korean Traditional Textiles by Acetaldehyde (아세트알데하이드에 의한 전통직물의 손상 특성)

  • Kim, Myoung Nam;Lim, Bo A;Lee, Sun Myung
    • Journal of Conservation Science
    • /
    • v.32 no.3
    • /
    • pp.321-331
    • /
    • 2016
  • Textiles damage caused by acetaldehyde($CH_3CHO$) is not clear as compared to other materials. Total 20 specimens were prepared using 4 different materials (silk, cotton, ramie, hemp) after dyed with 4 colors (undyed, red, yellow, blue, black). The specimens were exposed to $CH_3CHO$ gas in the test chamber. First, textile specimens' damage by differert concentration of acetaldehyde(0.1, 0.5, 1, 10, 100, 500, 1000 ppm) was tested. Second, accelerared damage to the textile specimens were tested according to the temperature and humidity conditions at the damage levels. Third, damage of deliberately degraded textile specimens were examined at the damage levels. After the exposure, optical, chemical, and physical evaluation was carried out. As a result, at 1000 ppm/day, the color difference of cotton_yellow has increased. At the condition of $25^{\circ}C-80%$, $30^{\circ}C-50%$, $30^{\circ}C-80%$, the color difference of yellow specimens has increased and grey scale rating has decreased. At $30^{\circ}C-80%$, acetate of cotton_undyed increased and the pH of silk_undyed decreased. In the case of deliberately degraded textile specimens, actetate concentration of black specimens increased. In conclusion, damage to the traditional fabric by acetaldehyde is not impact. However, it is expected that yellow specimens will be bleach and black specimens' actetate concentration will be increase.

The Verification of Breakage Possibility and Vibration Properties of Glass Insulators by the High-speed Railway Service (KTX 운행에 따른 가선설비 유리애자의 진동특성과 파손 가능성 검증)

  • Kim, Young-Seok;Shong, Kil-Mok;Jung, Jin-Su;Jeon, Yong-Joo
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.3
    • /
    • pp.566-572
    • /
    • 2009
  • This paper has studied breakage possibility of glass insulators by resonance and accelerated deterioration through the comparison of the natural vibration and on site vibration. The natural frequencies of the strut tube glass insulator was measured within a range of less than 1kHz. In the on site vibration, the largest frequency that was imposed on strut tube glass insulators was 80Hz with 1.13g of vertical vibration in the viaduct section, the largest vertical vibration (0.38g) was detected at 103Hz in the open route section. When site vibration and natural vibration of strut tube glass insulators were compared in terms of characteristics, the resonance frequency was not the same. In both the viaduct and open route sections, it seems that the impact by vertical vibration in strut tube glass insulators is large. It's very unlikely that glass insulators were damaged by fatigue accumulation of vibration since the possibility of damage by resonance was very low in consideration of the characteristics of natural vibration and site vibration of glass insulators. In addition, no damage was detected in the accelerated deterioration test.

Characteristics of Lightning Occurred over Jeju Island for 2004-2006 and an Effect of Lightning on Wind Turbine Generator System (2004-2006년에 발생한 제주지역의 낙뢰 특성 및 풍력발전기에 미치는 낙뢰의 영향)

  • Ko, Kyung-Nam;Kim, Kyoung-Bo;Huh, Jong-Chul
    • Journal of the Korean Solar Energy Society
    • /
    • v.28 no.1
    • /
    • pp.83-89
    • /
    • 2008
  • This paper presents the characteristics of lightning pver Jeju island and a case of emergency stop of a wind turbine due to lightning. Using the IMPACT ESP sensor to detect lightning, the data on lightning frequency, lightning strength, regional lightning event were obtained and analyzed in detail. The measurement period was for 3 years from 2004 to 2006. As a result, lightning occulted the most frequently in July and August. As for lightning strength, lightning with grades -4 to -6 and +3 to +5 occur ed more frequently. The eastern part of Jeju island had much more lightning frequency compared with the western part of it. Lightning with high grade occurred mainly in offshore site and the coastal region. Furthermore, the data on wind turbine stop caused by lightning was analyzed. Although wind turbine lightning damage was not much in this study, the investigation on lightning damage or lightning faults to a wind turbine should be conducted in Korea to increase availability of wind turbine.

A study on preventing the fall of skew and curved bridge decks by using rubber bearings

  • Ijima, Katsushi;Obiya, Hiroyuki;Aramaki, Gunji;Kawasaki, Noriaki
    • Structural Engineering and Mechanics
    • /
    • v.12 no.4
    • /
    • pp.347-362
    • /
    • 2001
  • The paper deals with preventing the collapse of by the means of supporting the bridges by rubber bearings and pedeck structures of skew and curved bridges during earthquakes, rmitting pounding between the decks and the abutments. Seismic response during pounding is characterized by various phenomena, such as the caging of bridge decks between abutments during an earthquake or decks popping out. These behaviors depend on only a small difference in seismic intensity. Regarding the global characteristics of a seismic response, smaller clearance between a deck and its abutments results in smaller impact damage of the abutments as well as lesser deformation of the rubber bearings. Similarly, smaller clearance between a deck and the side blocks results in smaller damage. The stiffnesses of the bearings and the stiffness ratio between them control the deck displacement. In short to medium length bridges, zero clearance between a deck and the abutments or the deck and the side blocks is the most effective way in preventing the deck from falling and limits the damage to the abutments or the side blocks.

Impact Damage Characteristics and Assessment of Insulators Due to Hitting Tester (타격시험기에 의한 애자 파손특성과 평가)

  • Shong, Kil-Mok;Kim, Jong-Min;Kim, Young-Seok;Jeon, Yong-Joo
    • Proceedings of the KIEE Conference
    • /
    • 2008.05a
    • /
    • pp.191-192
    • /
    • 2008
  • In this paper, we investigated on the characteristics and assessment of the insulators damaged by hitting tester(ST-100, Sharp-Eng, KOR). It made that an apparatus act on KS C 3801 for the damaged characteristics and assessment of insulators according to external scattering objects. There are selected 255mm glass insulators and 254mm porcelain insulators as the specimen. The hitting angles of the damaged insulator by pendulum weight are at $72^{\circ}$. At these points, velocity of pendulum weight is about 3.04m/sec and the force is 58.16N. At the hitting angle of 26 degrees, glass insulator is diffused the vibration within it but porcelain insulator is not. The inside vibrations of glass insulator and porcelain insulator are as like as two at the hitting angle of 53 degrees. The damaged glass insulator at the hitting angle of 72 degrees hardly is not diffused.

  • PDF

Vulnerability Assessment for a Complex Structure Using Vibration Response Induced by Impact Load (복합 구조물의 충격 응답 특성을 이용한 취약성 평가 모델 연구)

  • Park, Jeongwon;Koo, Man Hoi;Park, Junhong
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.38 no.10
    • /
    • pp.1125-1131
    • /
    • 2014
  • This work presents a vulnerability assessment procedure for a complex structure using vibration characteristics. The structural behavior of a three-dimensional framed structure subjected to impact forces was predicted using the spectral element method. The Timoshenko beam function was applied to simulate the impact wave propagations induced by a high-velocity projectile at relatively high frequencies. The interactions at the joints were analyzed for both flexural and longitudinal wave propagations. Simulations of the impact energy transfer through the entire structure were performed using the transient displacement and acceleration responses obtained from the frequency analysis. The kill probabilities of the crucial components for an operating system were calculated as a function of the predicted acceleration amplitudes according to the acceptable vibration levels. Following the proposed vulnerability assessment procedure, the vulnerable positions of a three-dimensional combat vehicle with high possibilities of damage generation of components by impact loading were identified from the estimated vibration responses.

Hypervelocity Impact Analysis Of Composite Plate For Space Shielding System (우주용 쉴딩 시스템에 적용할 복합재료 평판의 초고속 충돌 해석)

  • Son, Yu-Na;Moon, Jin-Bum;Lim, Gun;Kim, Chun-Gon
    • Composites Research
    • /
    • v.23 no.6
    • /
    • pp.14-18
    • /
    • 2010
  • Among the factors that threaten spacecraft, Micrometeoroid and Orbital Space Debris(MMOD) cause damage to spacecraft and impact velocity is about 8~70km/s. Nowadays, various Whipple Shield are studied and applied to protect spacecraft. As the materials used to Shielding System, aluminum is usually used but composite is also used increasingly. So this study compared characteristics of hypervelocity impact of Aluminum and composites through finite element analysis. The Projectile was a spherical shape using Aluminum 2017-T4, and aluminum plate was using Aluminum 6061-T6, CFRP plate was using T300/5208. Initial impact velocity of projectile was 1km/s. As a result, kinematic energy of projectile decreased to about 64J and about 63J for aluminum plate and CFRP plate, respectively after impact. Although both results is almost same about the absorption of impact energy, you can think the CFRP has good ballistic characteristic, because CFRP is lighter about 1.7 times compared with density of aluminum.

Evaluation of Residual Strength of CFRP Pressure Vessel After Low Velocity Impact (저속 충격 하중을 받은 탄소섬유강화 복합재 압력용기의 잔류강도 저하 평가)

  • Park, Jae-Beom;Kim, Dong-Ryun;Kim, Hyung-Geun;Hwang, Tae-Kyung
    • Composites Research
    • /
    • v.21 no.3
    • /
    • pp.9-17
    • /
    • 2008
  • In this paper, the low velocity impact characteristics of filament winding CFRP pressure vessel was investigated using numerical and experimental methods. The cylinder part of CFRP vessel was impacted using triangular shape impactor which simulated the sharp edge of dropping tools and impact response behavior of CFRP was reviewed. The mechanical behavior, such as deformation and stress distribution, were also predicted by explicit finite element method and the validity of the model was investigated. For the quantitative evaluation of the residual strength of the pressure vessel after impact, a series of the ring specimens was cut from the impacted vessel and its burst pressure was measured by hydraulic pressure hoop tension test. As the results, the relationship between the residual strength degradation and the impact energy was successively obtained and a useful methodology to evaluate quantitatively the impact damage tolerance of CFRP pressure vessel was established.

A Study on Solid Particle Erosion Characteristics of Surface Treated 12wt%Cr Steel for USC Power Plant (USC 화력발전소용 12wt%Cr강의 표면처리에 따른 고체입자침식특성에 관한 연구)

  • 엄기원;이선호;이의열
    • Proceedings of the KWS Conference
    • /
    • 2004.05a
    • /
    • pp.324-326
    • /
    • 2004
  • l2wt%Cr Steel has been applied on turbine bucket and nozzle partition material of power plant. Turbine bucket and nozzle get damaged by solid particle within steam, therefore they are protected by surface treatments such as ion nitriding, boriding and chrome carbide HVOF spray coating. In this study, solid particle erosion(SPE) characteristics after these surface treatments are examined at operating temperature 540$^{\circ}C$ and 590$^{\circ}C$ of fossil power plant and the mechanism of damage was studied. Erosion of 12wt%Cr steel is originated by micro cutting and that of boriding and chrome carbide HVOF spray is originated by these mechanism - repeating collision, crack initiation and propagation. As the results of SPE test at 540$^{\circ}C$ and 30$^{\circ}$ impact angle that is the most commonly occurred in power plant, Boriding had the best SPE -resistance property, Cr$_2$C$_3$-25(Ni20Cr) HVOF spayed and ion nitrided samples were also better than bare metals(l2wt%Cr Steels). At 590$^{\circ}C$ and 30$^{\circ}$ impact angle, Boriding had also the most superior characteristic and HVOF spay sample was better than bare metal.

  • PDF

Hygrothermal and Impact Damage Evaluation of CFRP Hat shaped sectional members with Stacking Angle Variation (적층각도 변화를 갖는 CFRP 모자형 단면부재의 열습 및 충격손상 평가)

  • Yang, Yong-Jun;Sim, Jae-Ki
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.19 no.6
    • /
    • pp.782-789
    • /
    • 2010
  • It is important to satisfy the requirements and standards for the protections of passengers in a car accident. There are lots of studies on the crushing energy absorption of a structure member in automobiles. In this paper, we have studied to investigate collapse characteristics and moisture absorption movements of CFRP( carbon fiber reinforced plastics) structure members when CFRP laminates are under the hygrothermal environment. In particular, the absorbed energy, mean collapse load and deformation mode were analyzed for CFRP members which absorbed most of the collision energy. Also, variation of stacking angle is important to increase the energy absorption capability. The purpose of this study is to evaluate the strength reduction and moisture absorption behavior of CFRP hat shaped member. Therefore we have made a impact collapse experiment to research into the difference of absorbed energy and deformation mode between moisture absorbed specimen and non-moisture absorbed. As a result, the effect of moisture absorption and impact loads of approximately 50% reduction in strength are shown.