Journal of Dental Rehabilitation and Applied Science
/
v.30
no.2
/
pp.138-144
/
2014
Purpose: This study examined the water sorption of commonly used dual-cure resin cements and compared the change in the micro-hardness among the cements. Materials and Methods: Five types of dual-cure resin cements (Maxcem, Duo-link, Panavia F, Variolink II, Rely X Unicem) were selected. Fifty specimens were classified into five groups containing ten specimens in each group. The water sorption of the five specimens in each group was evaluated after being immersed in distilled water (DDW) for seven days. The following results were obtained by comparing the specimens immersed in DDW with those not immersed in DDW. Results: 1. The water sorption of Maxcem showed the highest score, followed by Panavia F. These two cements were followed by Duo-link and Rely X Unicem. The water sorption of Variolink II showed the lowest score among the cements used in this study. 2. Among the specimens not immersed in DDW, the micro-hardness of Rely X Unicem showed the highest score followed by Panavia F and Variolink II. These cements were followed in order by Duo-link and Maxcem. 3. Among the specimens immersed in DDW, the microhardness of Rely X Unicem showed the highest score followed by Maxcem, Panavia F and Variolink II. Duo-link shoed the lowest score among the cements used in this study. 4. Maxcem, Duo-link, Panavia F and Rely X Unicem showed significant differences in micro-hardness due to water resorption but Variolink II was unaffected by immersion in water. Conclusion: Using the resin cement which has lower water sorption and higher micro-hardness is recommended.
The purpose of this study was to observe characteristic properties through the polarization curves and SEM images from 4 different types of amalgam obtained by using the potentiostats (Princeton EG & G) & SEM (Jeol/35), and to investigate the degree of corrosion on the oxidation peak of the each phase of amalgam. After each amalgam alloy and Hg was triturated as the direction of the manufacturer by means of the mechanical amalgamator (Shofu Co.), the triturated mass was inserted into the cylindrical metal mold which was 12mm in diameter and 10.0mm in height and was condensed by using routine manner. The specimen was removed from the mold and stored at room temperature for about 24 hours. The standard surface preparation was routinely carried out. Anodic polarization measurement was employed to confirm the corrosion behaviour of the amalgams in a 0.9% saline solution (P.H: 6.8-7.0) at $37^{\circ}C$. The initial rest potential (corrosion potential) was determined after 30 minutes of immersion of specimen in electrolyte, and the potential scan was begun at the point of 100mV cathodic from the corrosion potential. The scan rate was 0.17mV/sec. in the study to observe the degree of corrosion of each phase. SEI and EPMA images on the determined oxidation peaks of each amalgam were observed. The results were as follows: 1. In the four anodic polarization curves, low copper amalgams have three oxidation peaks and high copper amalgams have two oxidation peaks, -270mV, +26mV and +179mV(SEC) in the low copper lathe cut, and -300mV, +39mV and +163mV(SEC) in the low copper spherical. -4mV and +154mV(SEC) in the Dispersalloy, and +17mV and +180mV(SEC) in the Tytin as high copper amalgams. 2. ${\gamma}_2$ phase in the low copper amalgam and ${\eta}$ phase in the high copper amalgam were the most corrodible phases and Ag-Cu eutectic in high copper amalgam was the most slowly corroded phase. 3. Low copper amalgam was more susceptible in corrosion than high copper amalgam.
The purpose of this study was to observe characteristic properties through the polarization curves and EMPA images from 4 different types of amalgam obtained by using the potentiostats (EG & G PARC) & EPMA (Jeol JSM-35), to investigate the degree of corrosion of each phase of amalgam on the oxidation peak, and to identify corrosion products from the corroded amalgam by use of X-ray diffractometer(Rigaku). After each amlgam alloy and Hg were triturated as the direction of the manufacturer by means of the mechanical amalgamator(Shofu), the triturated mass was inserted into the cylindrical metal mold which was 12mm in diameter and 10mm in height and was condensed by means of routine manner. The specimen was removed from the mold and stored at room temperature for about 7 days. The standard surface preparation was routinely carried out. Anodic polarization measurement was employed to compare the corrosion behaviours of the amalgams in 0.9% saline solution(pH6.8~7.0) and artificial saliva (pH6.8~7.0) at $37^{\circ}C$. The open circuit potential was determined after 30 minutes' immersion of specimen in electrolyte and the potential scan was begun at the potential of 100mV cathodic from the corrosion potential. The scan rate was 1mV/sec and the surface area of amalgam exposed to the solution was 0.64$cm^2$ for each specimen. All the potentials reported are with respect to a saturated calomel electrode (SCE). EPMA images on the determined oxidation peaks of each amalgam in artificial saliva were observed. X-ray diffraction patterns of each sample were recorded before and after polarization in artificial saliva (Aristaloy, Caulk Spherical, Dispersalloy and Tytin: at +770mV, +585mV, +8.10m V and +680m V respectively) by use of a recording diffractometer. Nickel filtered Cu $K_{{\alpha}_1}$ radiation was used and sample was scanned at $4^{\circ}(2{\theta})/min.$ from $25^{\circ}$ to $80^{\circ}$. The following results were obtained. 1. Oxidation peak potential in artificial saliva shifted to more anodic direction than that in saline solution. 2. The corrosion potential of high copper amalgam was more anodic than the potential of low copper amalgam. 3. The current density was lower in artificial saliva than in saline solution. 4. One of the corrosion products, AgCl was identified by X-ray diffraction analysis. 5. ${\gamma}_2$ phase was the most susceptible to corrosion and e phase was stable in low copper amalgam and ${\eta}$' phase and Ag-Cu eutectic were susceptible to corrosion in high copper amalgam.
The purpose of this study was to evaluate the difference in the surface roughness after polishing and to evaluate the difference in color stability after immersion in a dye solution among four types of composite resin materials. Four light-polymerized composite resins(Shade A2) with different sized filler content(a nanofilled, a hybrid, a microfilled, a flowble) were used. Average surface roughness (Ra) was measured with a surface roughness tester (Surftest Formtracer) before and after polishing with aluminum oxide abrasive discs(Super-Snap). Color of specimens before and after staining with 2% methylene blue solution were measured using spectrophotometer(CM-3700d) with SCI geometries. The results of Ra and ${\Delta}E$ were analyzed by one-way analysis of variance(ANOVA), a Scheffe multiple comparison test and Student t-test(p=0.05). After polishing, Ra values were decreased regardless of type of composite resins. In surface roughness after polishing and color stability after staining, nanofilled composite resin was not different with other composite resins except flowable resins.
Park, Soo-Jin;Kim, Jong-Hak;Choi, Kil-Yeong;Joo, Hyeok-Jong;Jin, Fan-Long
Elastomers and Composites
/
v.40
no.3
/
pp.166-173
/
2005
Effect of thermal aging on the weight loss and water absorption of epoxy adhesives was investigated in the presence of three types of different hardeners, such as D-230, G-5022, and HN-2200. Thermal and mechanical properties of the cured epoxy resins were also studied througth the glass transition temperature and shear adhesion strength measurements. Weight losses of DGEBA/D-230 and DGEBA/HN- 2200 systems were not varied. However, the weight of DGEBA/G-5022 system was significantly decreased with increasing the thermal aging time. The water absorption of the specimens was increased as the thermal aging time increased except that using G-5022. DEGBA/HN-2200 system showed higher $T_g$ value than those of other systems, due to the formation of the fine three-dimensional network structure containing aliphatic ring. Shear adhesion strength of all systems was increased with increasing the thermal aging tine, which is attributed to increased degree of cure and fine three-dimensional network structure formation. And $T_g$ values and shear adhesion strength of all specimens exposed to water was decreased as the immersion time increased.
Background: Nucleolar organizer regions(NORs) are chromosomal segments encoding for ribosomal RNA and associated with argyrophilic nonhistone protein. Ribosomal RNA genes ultimately direct ribosome and protein synthesis, and it has been suggested the numbers of NORs detected in the cell may reflect nuclear and cellular activity. This study was performed to evaluate the applicability of AgNORs to the diagnosis of squamous cell carcinoma of the lung. Method: The one step silver methods(AgNORs) was used to stain NORs in the routinely processed, formalin fixed, paraffin embedded sections of 36 cases of squamous cell carcinoma of the lung obtained by surgical resection of primary tumor. In each specimen, 100 tumor cells and 100 normal cells adjacent to the tumor chosen at random were examined under an oil immersion lens at a magnification of ${\times}1000$. The mean number of AgNORs per nucleus was calculated for each specimen. Results: The mean number of AgNORs per nucleus(mAgNORs) of normal bronchial epithelium and squamous cell carcinoma of the lung was $1.74{\pm}0.25$ and $4.05{\pm}0.80$, respectively. The difference of mAgNOR between normal and tumor tissue was statistically significant(p<0.001). There was no statistical difference among tumors of different stages. The difference of mAgNOR between normal and tumor tissue was statistically significant in each TNM stage(p<0.05). Conclusion: Mean AgNOR count may be used as a useful marker for the differential diagnosis of benignancy and malignancy, and proliferative activity of the cell in squamous cell carcinoma of the lung. But there was no statistical difference in mean AgNOR count among tumors of different surgical stages. Further studies for the application of mAgNORs to the diagnosis of other histologic types and cytologic specimens of the lung cancer are needed.
Commercial tofu was cut and re-packed in a vacuum container, an airtight container and an open tofu tray in an effort to assess the effects of vacuum containers on the shelf life of leftover tofu. The re-packed tofu were stored at $5^{\circ}C$ and $25^{\circ}C$ for the enumeration of total bacteria and coliforms. We also measured changes in color, pH, and opacity. The vacuum retarded the bacterial growth under $10^5$ CFU/mL for up to 12 days at $5^{\circ}C$. The color of the tofu was unaffected by the container type at both storage temperatures, whereas the pH and opacity of the immersion solution were altered less profoundly by storage in the vacuum container at $5^{\circ}C$. However, we noted no significant differences in bacterial growths, pH, and opacity among container types at $25^{\circ}C$. The results of this study showed that the usage of vacuum containers may be a favorable method for the preservation of tofu under refrigerated conditions.
The steam generator tubes of nuclear power plants have various types of corrosion failures during the plant operation. The stress corrosion cracking which occurs on the outer surface of tube is called the secondary side stress corrosion cracking and mainly occurs in the expansion-transition area of tube. The causes are the concentration of impurities by the sludge pile-up related to the geometry of its region and the residual stress by tube expansion in the process of steam generator manufacturing. Especially the directionality and sizes of residual stresses are differed according to the tube expansion methods and the direction and the frequency of tube cracks depend on their characteristics. In bases on the plant experiences, it is notified that circumferential cracks of tubes expanded with explosive expansion method are dominantly occurred compared to those of tubes done with hydraulic expansion one. Therefore in this study, according to tube expansion methods frequencies and sizes of tube cracks with specific direction are compared by means of accelerated immersion test and also the crack morphology and the specific chemicals from water-chemistry environment are observed through the fracture surface examination.
Journal of the Korea Academia-Industrial cooperation Society
/
v.10
no.9
/
pp.2290-2299
/
2009
This study aims to analyze the importances of various SCM adoption factors suggested in precedent researches with AHP. SCM adoption factors were categorized by four types: organization factor, transaction factor, relation factor, and information factor. Each factor has sub-factors. Organization factor has five sub-factors: adoption strategy, support of CEO, maturity of information technology, development of assessment system, and innovation leadership. Transaction factor has three sub-factors: transaction period, delivery/quality,
and shared goal. Relation factor has five sub-factors: trust, collaboration, inter-dependence, conflict, and immersion. Information factor has three sub-factors: information quality, information share, and information exchange. There are sixteen sub-factors altogether. Analyzing the importances of SCM adoption factors with AHP, the importance of organization factor(.387) ranked the highest. Relation factor(.291), information factor(.167), and transaction factor(.155) followed. Putting the analysis results of primary hierarchy factors and
secondary hierarchy factors together, support of CEO(.169) ranked the highest and trust(.124), adoption strateg (.089), share goal(.081), information exchange(.069), collaboration(.064), and information share (.057) followed.
The purpose of this study is to investigate the effect of teaching style of liberal arts physical education professors to class satisfaction, Class flow and physical education attitude of liberal arts students. A study was conducted on a total of 221 liberal arts students. For the collected data, a confirmatory factor analysis and reliability analysis (Cronbach' α) for the measurement tool were performed using the SPSS 26.0 and Amos 21.0 programs. And correlation analysis and multiple regression analysis were performed. The liberal arts physical education Professor's teaching stlye affects the student's class satisfaction (educational satisfaction, environmental satisfaction, psychosocial satisfaction, physical satisfaction), and students' class flow (class immersion, purpose experience, consciousness agreement, challenge, control, Integration). In addition, it has various effects on the student's attitude toward physical education(relationships, physical activity, active participation, health and physical fitness, positive emotions). Efforts to strengthen the competence of liberal arts physical education professors will be needed to revitalize the liberal arts physical education.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.