• Title/Summary/Keyword: Imaging method

Search Result 3,030, Processing Time 0.054 seconds

Magnetic Resonance Imaging of the Temporomandibular Joint (측두하악관절의 핵자기공명영상 촬영에 관한 연구)

  • Nah Kyung-Soo
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.29 no.2
    • /
    • pp.407-410
    • /
    • 1999
  • Purpose; To find out the best imaging parameters for the diagnosis of disc in MRI imaging. Materials and methods; The diagnostic quality of the disc among the Tl, PD and T2 images of same patients02 joints, 223 images) was compared by visual(I-IV grades) and gray level measurement (pre- and infra-discal area) method. Results; PD images showed best results with 43.7% of the images belonging to grade III (good) and with statistically significant higher difference of the gray levels at pre- and infra-discal areas. But there were no grade N (excellent) images. Conclusions; PD images are best method among Tl. PD and T2 images in diagnosing the disc but since there were no excellent images further imaging parameters should be studied for better images.

  • PDF

Characterizations of Two-step Matrix Application Procedures for Imaging Mass Spectrometry

  • Shimma, Shuichi
    • Mass Spectrometry Letters
    • /
    • v.6 no.1
    • /
    • pp.21-25
    • /
    • 2015
  • In this paper, I describe the importance of matrix spraying conditions in imaging mass spectrometry (IMS) to obtain successful imaging results. My developed matrix application methodology, which is a "two-step matrix application" sequentially combined with matrix sublimation and spraying matrix solution can provide high reproducibility and high ion yield compared with a conventional direct spraying method. However, insufficient IMS results were obtained occasionally despite the two-step method. Therefore, I wanted to characterize the methodology to continuously provide high quality data. According to my results, the sublimation time was not a strict parameter, and the most important step was the first spraying condition. This means that the extraction conditions from the tissue section and co-crystallization of the matrix were the most important factors.

Evaluation of Selective Saturation and Refocousing Pulses in Chemical Shift NMR Imaging

  • Shin, Yong-Jin;Park, Young-Sik
    • Journal of the Korean Magnetic Resonance Society
    • /
    • v.4 no.1
    • /
    • pp.64-73
    • /
    • 2000
  • There are several methods to achieve selective NMR image of differing chemical species with the three most popular methods of Dixon's, CHESS, and SECSI. A major problem common to all chemical shift imaging methods is the uniformity of the static magnetic field and distortions introduced when RF coils are loaded with a conducting specimen. Without magnetic field shimming, these methods cannot be used to acquire selectively image protons in fat and water which are separated by approximately 3.0ppm. Experiments with a phantom, with linewidths of 2.5 to 3.5ppm, were quantitatively evaluated for the three methods and a new chemical shift imaging method. In this study the new chemical shift imaging method (modified CHESS+SECSI technique) which included a selective saturation and refocusing pulse, was developed to determine the ratios of water and fat in different samples.

  • PDF

Triply-Encoded Hadamard Transform Imaging Spectrometer using the Grill Spectrometer (그릴 분광계를 사용하여 3중 부호화한 하다마드 변환 영상 분광계)

  • Kwak, Dae-Yun;Park, Jin-Bae;Park, Yeong-Jae
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.48 no.12
    • /
    • pp.1527-1536
    • /
    • 1999
  • In this paper, a triply-encoded Hadamard transform imaging spectrometer is proposed by applying the grill spectrometer to the Hadamard transform imaging spectrometer. The proposed system encodes the input radiation triply ; once through the input image mask and twice through the two masks in the grill spectrometer. We use an electro-optical mask in the grill spectrometer which is controlled by a left-cyclic simplex matrix. Then we modeled the system using $D^{-1}$ method. In this paper, the average mean square error associated with a recovered estimate is considered for performance evaluation. The relative performance is compared with those of the other conventional systems.

  • PDF

Reduction of Susceptibility Artifact in MR Gradient Echo Imaging (MR Gradient Echo 영상술에서 자화율에 의한 에러의 감소에 관한 연구)

  • Ro, Y.M.;Cho, Z.H.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1990 no.11
    • /
    • pp.19-23
    • /
    • 1990
  • A new technique for reducing the susceptibility artifact in gradient echo imaging which uses a tailored RF pulse is proposed. It is applied to the case of imaging where artifacts and distortions arise due to the high local magnetic field inhomogeneity i. e., the susceptibility. The signal loss and void phenomena due to susceptibility in a voxel are studied and a correction method using a tailored RF pulse is proposed. Applications of this method in imaging are given and experimental results obtained using an human volunteer with a 2.0 T KAIS NMR system are presented.

  • PDF

Design and Implementation of High-Resolution Integral Imaging Display System using Expanded Depth Image

  • Song, Min-Ho;Lim, Byung-Muk;Ryu, Ga-A;Ha, Jong-Sung;Yoo, Kwan-Hee
    • International Journal of Contents
    • /
    • v.14 no.3
    • /
    • pp.1-6
    • /
    • 2018
  • For 3D display applications, auto-stereoscopic display methods that can provide 3D images without glasses have been actively developed. This paper is concerned with developing a display system for elemental images of real space using integral imaging. Unlike the conventional method, which reduces a color image to the level as much as a generated depth image does, we have minimized original color image data loss by generating an enlarged depth image with interpolation methods. Our method was efficiently implemented by applying a GPU parallel processing technique with OpenCL to rapidly generate a large amount of elemental image data. We also obtained experimental results for displaying higher quality integral imaging rather than one generated by previous methods.

Distance Extraction by Means of Photon-Counting Passive Sensing Combined with Integral Imaging

  • Yeom, Seok-Won;Woo, Yong-Hyen;Baek, Won-Woo
    • Journal of the Optical Society of Korea
    • /
    • v.15 no.4
    • /
    • pp.357-361
    • /
    • 2011
  • Photon-counting sensing is a widely used technique for low-light-level imaging applications. This paper proposes a distance information extraction method with photon-counting passive sensing under low-lightlevel conditions. The photo-counting passive sensing combined with integral imaging generates a photon-limited elemental image array. Maximum-likelihood estimation (MLE) is used to reconstruct the photon-limited image at certain depth levels. The distance information is extracted at the depth level that minimizes the sum of the standard deviation of the corresponding photo-events in the elemental image array. Experimental and simulation results confirm that the proposed method can extract the distance information of the object under low-light-level conditions.

Hand motion estimation for interactive image composition (상호작용 영상합성을 위한 손의 움직임 추정)

  • Koo, Ddeo-Ol-Ra;Seo, Yung-Ho;Doo, Kyoung-Soo;Choi, Jong-Soo
    • Proceedings of the IEEK Conference
    • /
    • 2008.06a
    • /
    • pp.951-952
    • /
    • 2008
  • This paper proposes a new method for image composition which estimates the rotation angle of human hand and uses the reserved image in real-time camera images. First, we capture a background image and extract a interesting region by background subtraction. Next, we estimate the skin region from the interesting region and calculate the rotation angle of estimated skin region using PCA(Principal Components Analysis). Finally, we composite the reserved image for the calculated rotation angle in camera images. The proposed method can be applied to control the 3D avatar for marker-less augmented reality.

  • PDF

Incoherent imaging method for high-contrast cylindrical cavity by using frequency-averaged electric field intensity pttern (주파수평균된 전계전력패턴을 사용한 high-contrast 원기둥 공동의 incoherent 영상법)

  • 강진섭;라정웅
    • Journal of the Korean Institute of Telematics and Electronics D
    • /
    • v.35D no.2
    • /
    • pp.1-12
    • /
    • 1998
  • In this paper, an incoherent imaging of a high-contrast cylindrical cavity illuminated by the time-harmonic cylindrical wave is obtained ia the back-projections of he incoherent intensity patterns, which si acquired by averaging out the multi-frequency intensities of the total electric field scattered from this object in the cross-borehole measurement configuration. Multi-freuqncy effect is shown numerically and is intepreted analytically by the mutual coherence function defined in the is frequency domain. This imaging method is validated by imaging high-contrast cylindrical cavidities and the conditions to get better image are investigated.

  • PDF

Design of the Shimming Coils for MRI Magnet (MRI 마그네트용 보정코일 설계)

  • Bae, Jun-Han;Go, Rak-Gil;Jin, Hong-Beom;Sim, Gi-Deok;Gwon, Yeong-Gil;Ryu, Gang-Sik
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.50 no.12
    • /
    • pp.587-591
    • /
    • 2001
  • This paper describes the general and efficient design method of an axial and a radial shim coils to correct field impurities of various harmonic orders in the imaging volume of Magnetic Resonance Imaging magnet. Shim coils are optimized by BCLSF subroutine of IMSL, which is the well-known commercial package for optimization, aiming at maximizing the magnitude of the desired field component as well as minimizing other field components. In order to evaluate their effect, the developed method was applied to the MRI magnet constructed in KERI.

  • PDF