• 제목/요약/키워드: Imaging condition

검색결과 662건 처리시간 0.034초

Research on the Applicability of Target-detection Methods for Land-based Hyperspectral Imaging

  • Qianghui Wang;Bing Zhou;Wenshen Hua;Jiaju Ying;Xun Liu;Lei Deng
    • Current Optics and Photonics
    • /
    • 제8권3호
    • /
    • pp.282-299
    • /
    • 2024
  • Target detection (TD) is a research hotspot in the field of hyperspectral imaging (HSI). Traditional TD methods often mine targets from HSIs under a single imaging condition, without considering the influence of imaging conditions. In fact, the spectra of ground objects in HSIs are uncertain and affected by the imaging conditions (weather, atmospheric, light, time, and other angle conditions including zenith angle). Hyperspectral data changes under different imaging conditions. Therefore, the detection result for a single imaging condition cannot accurately reflect the effectiveness of the detection method used. It is necessary to analyze the performance of various detection methods under different imaging conditions, to find a more applicable detection method. In this paper, we study the performance of TD methods under various land-based imaging conditions. We first summarize classical TD methods and evaluation methods. Then, the detection effects under various imaging conditions are analyzed. Finally, the concepts of the stability coefficient (SC) and effective area under the curve (EAUC) are proposed to comprehensively evaluate the applicability of detection methods under land-based imaging conditions, in terms of both detection accuracy and stability. This is conducive to our selection of detection methods with better applicability in land-based contexts, to improve detection accuracy and stability.

종양 모델 연구를 위한 소동물 $[^{18}F]$FDG PET 영상화 (Small Animal Small Animal $[^{18}F]$FDG PET Imaging for Tumor Model Study)

  • 우상근;김경민;천기정
    • Nuclear Medicine and Molecular Imaging
    • /
    • 제42권1호
    • /
    • pp.1-7
    • /
    • 2008
  • PET allows non-invasive, quantitative and repetitive imaging of biological function in living animals. Small animal PET imaging with $[^{18}F]$FDG has been successfully applied to investigation of metabolism, receptor-ligand interactions, gene expression, adoptive cell therapy and somatic gene therapy. Experimental condition of animal handling impacts on the biodistribution of $[^{18}F]$FDG in small animal study. The small animal PET and CT images were registered using the hardware fiducial markers and small animal contour point. Tumor imaging in small animal with small animal $[^{18}F]$FDG PET should be considered fasting, warming, and isoflurane anesthesia level. Registered imaging with small animal PET and CT image could be useful for the detection of tumor. Small animal experimental condition of animal handling and registration method will be of most importance for small lesion detection of metastases tumor model.

Hypostereoscopic condition in mobile stereoscopy

  • Lee, Kwang-Hoon;Kim, Dong-Wook;Kwon, Yong-Moo;Hur, Nam-Ho;Kim, Sung-Kyu
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2009년도 9th International Meeting on Information Display
    • /
    • pp.1103-1106
    • /
    • 2009
  • In this paper, we investigated the properties of hypostereoscopic condition in mobile circumstance and simulated the main factors to embody an effective presence to the reconstructed depth image, which are both the limited disparity for fusible stereo and the object space possible for quantifying.

  • PDF

Distortionless optimal stereoscopic image condition considering general viewing distance in the TV condition

  • Kim, Dong-Wook;Lee, Kwang-Ho;Chang, Eun-Young;Kim, Sung-Kyu
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2008년도 International Meeting on Information Display
    • /
    • pp.703-706
    • /
    • 2008
  • Large distortion is made by toed-in camera configuration in the TV condition that has short viewing distance, when the gaze position of a stereoscopic image coincides with that of real space. Therefore, in the TV condition, we confirmed that the proper camera configuration is the modified parallel configuration, and found distortionless optimal stereoscopic image condition using this camera configuration.

  • PDF

Transformations and Their Analysis from a RGBD Image to Elemental Image Array for 3D Integral Imaging and Coding

  • Yoo, Hoon
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • 제12권5호
    • /
    • pp.2273-2286
    • /
    • 2018
  • This paper describes transformations between elemental image arrays and a RGBD image for three-dimensional integral imaging and transmitting systems. Two transformations are introduced and analyzed in the proposed method. Normally, a RGBD image is utilized in efficient 3D data transmission although 3D imaging and display is restricted. Thus, a pixel-to-pixel mapping is required to obtain an elemental image array from a RGBD image. However, transformations and their analysis have little attention in computational integral imaging and transmission. Thus, in this paper, we introduce two different mapping methods that are called as the forward and backward mapping methods. Also, two mappings are analyzed and compared in terms of complexity and visual quality. In addition, a special condition, named as the hole-free condition in this paper, is proposed to understand the methods analytically. To verify our analysis, we carry out experiments for test images and the results indicate that the proposed methods and their analysis work in terms of the computational cost and visual quality.

적외선 열화상 카메라를 이용한 수전설비 온도분포해석 (The Analysis of Temperature Distribution Electric incoming Apparatus Using a Infrared Thermal Imaging System)

  • 정승천;임용배
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2004년도 하계학술대회 논문집 Vol.5 No.2
    • /
    • pp.1113-1116
    • /
    • 2004
  • This paper presents the method for analyzing surface temperature of Electric incoming Apparatus. For the experiment, the surface temperature of electric power apparatus was measured and analyzed by using a infrared thermal imaging system. Surface Discharges(SD) have very complex characteristics of discharge patterns, therefore it requires the development of precise analysis methods. recently, studies on infrared thermal imaging system are carried out to analyze temperature distribution of power equipments through condition diagnosis and to diagnose the degradation of power equipments. The changes in suface temperature was measured by using the infrared thermal imaging system under hot line condition. The system was set up based on the diagnostic method of the electric incoming apparatus.

  • PDF

Comparison of Gold Biosensor Combined with Light Microscope Imaging System with ELISA for Detecting Salmonella in Chicken after Exposure to Simulated Chilling Condition

  • Mi-Kyung Park
    • Journal of Microbiology and Biotechnology
    • /
    • 제33권2호
    • /
    • pp.228-234
    • /
    • 2023
  • In this study, the performance of a gold biosensor combined with light microscope imaging system (GB-LMIS) was comparatively evaluated against enzyme-linked immunosorbent assay (ELISA) for detecting Salmonella under simulated chilling condition. The optimum concentration of antiSalmonella polyclonal antibodies (pAbs) was determined to be 12.5 and 100 ㎍/ml for ELISA and GBLMIS, respectively. GB-LMIS exhibited a sufficient and competitive specificity toward three tested Salmonella among only. To mimic a real-world situation, chicken was inoculated with Salmonella cocktail and stored under chilling condition for 48 h. The overall growth of Salmonella under chilling condition was significantly lower than that under non-exposure to the chilling condition (p < 0.05). No significant differences in bacterial growth were observed between brain heart infusion and brilliant green broth during the enrichment period (p > 0.05). Finally, both GB-LMIS and ELISA were employed to detect Salmonella at every 2-h interval. GB-LMIS detected Salmonella with a competitive specificity by the direct observation of bacteria on the sensor using a charge-coupled device camera within a detection time of ~2.5 h. GB-LMIS is a feasible, novel, and rapid method for detecting Salmonella in poultry facilities.

Characteristics of integral imaging microscope using point light source array

  • Lim, Young-Tae;Park, Jae-Hyeung;Kwon, Ki-Chul;Kim, Nam
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2009년도 9th International Meeting on Information Display
    • /
    • pp.1354-1356
    • /
    • 2009
  • In this paper, we explained characteristics of integral imaging microscope using point light source. To display the bio-medical information, which is captured as a form of the elemental images, using autostereoscopic displays, the characteristics analysis of three-dimensional information is required. For integral imaging microscope using point light source array, the elemental image capturing configuration has to satisfy a specific condition. We explain the condition to capture the elemental images and show the experimental results.

  • PDF

Fascicular Involvement of the Median Nerve Trunk in the Upper Arm: Manifestation as Anterior Interosseous Nerve Syndrome With Unique Imaging Features

  • Jae Eun Park;Darryl B. Sneag;Yun Sun Choi;Sung Hoon Oh;SeongJu Choi
    • Korean Journal of Radiology
    • /
    • 제25권5호
    • /
    • pp.449-458
    • /
    • 2024
  • Selective fascicular involvement of the median nerve trunk above the elbow leading to anterior interosseous nerve (AIN) syndrome is a rare form of peripheral neuropathy. This condition has recently garnered increased attention within the medical community owing to advancements in imaging techniques and a growing number of reported cases. In this article, we explore the topographical anatomy of the median nerve trunk and the clinical features associated with AIN palsy. Our focus extends to unique manifestations captured through MRI and ultrasonography (US) studies, highlighting noteworthy findings, such as nerve fascicle swelling, incomplete constrictions, hourglass-like constrictions, and torsions, particularly in the posterior/posteromedial region of the median nerve. Surgical observations have further enhanced the understanding of this complex neuropathic condition. High-resolution MRI not only reveals denervation changes in the AIN and median nerve territories but also illuminates these alterations without the presence of compressing structures. The pivotal roles of high-resolution MRI and US in diagnosing this condition and guiding the formulation of an optimal treatment strategy are emphasized.

Compact Catadioptric Wide Imaging with Secondary Planar Mirror

  • Ko, Young-Jun;Yi, Soo-Yeong
    • Current Optics and Photonics
    • /
    • 제3권4호
    • /
    • pp.329-335
    • /
    • 2019
  • Wide FOV imaging systems are important for acquiring rich visual information. A conventional catadioptric imaging system deploys a camera in front of a curved mirror to acquire a wide FOV image. This is a cumbersome setup and causes unnecessary occlusions in the acquired image. In order to reduce both the burden of the camera deployment and the occlusions in the images, this study uses a secondary planar mirror in the catadioptric imaging system. A compact design of the catadioptric imaging system and a condition for the position of the secondary planar mirror to satisfy the central imaging are presented. The image acquisition model of the catadioptric imaging system with a secondary planar mirror is discussed based on the principles of geometric optics in this study. As a backward mapping, the acquired image is restored to a distortion-free image in the experiments.