• Title/Summary/Keyword: Imaging analysis

Search Result 2,980, Processing Time 0.024 seconds

Brain Mapping Using Neuroimaging

  • Tae, Woo-Suk;Kang, Shin-Hyuk;Ham, Byung-Joo;Kim, Byung-Jo;Pyun, Sung-Bom
    • Applied Microscopy
    • /
    • v.46 no.4
    • /
    • pp.179-183
    • /
    • 2016
  • Mapping brain structural and functional connections through the whole brain is essential for understanding brain mechanisms and the physiological bases of brain diseases. Although region specific structural or functional deficits cause brain diseases, the changes of interregional connections could also be important factors of brain diseases. This review will introduce common neuroimaging modalities, including structural magnetic resonance imaging (MRI), functional MRI (fMRI), diffusion tensor imaging, and other recent neuroimaging analyses methods, such as voxel-based morphometry, cortical thickness analysis, local gyrification index, and shape analysis for structural imaging. Tract-Based Spatial Statistics, TRActs Constrained by UnderLying Anatomy for diffusion MRI, and independent component analysis for fMRI also will also be introduced.

Improved 3D Resolution Analysis of N-Ocular Imaging Systems with the Defocusing Effect of an Imaging Lens

  • Lee, Min-Chul;Inoue, Kotaro;Cho, Myungjin
    • Journal of information and communication convergence engineering
    • /
    • v.13 no.4
    • /
    • pp.270-274
    • /
    • 2015
  • In this paper, we propose an improved framework to analyze an N-ocular imaging system under fixed constrained resources such as the number of image sensors, the pixel size of image sensors, the distance between adjacent image sensors, the focal length of image sensors, and field of view of image sensors. This proposed framework takes into consideration, for the first time, the defocusing effect of the imaging lenses according to the object distance. Based on the proposed framework, the N-ocular imaging system such as integral imaging is analyzed in terms of depth resolution using two-point-source resolution analysis. By taking into consideration the defocusing effect of the imaging lenses using ray projection model, it is shown that an improved depth resolution can be obtained near the central depth plane as the number of cameras increases. To validate the proposed framework, Monte Carlo simulations are carried out and the results are analyzed.

Quantitative and qualitative analysis of autophagy flux using imaging

  • Kim, Suree;Choi, Soohee;Kang, Dongmin
    • BMB Reports
    • /
    • v.53 no.5
    • /
    • pp.241-247
    • /
    • 2020
  • As an intracellular degradation system, autophagy is an essential and defensive cellular program required for cell survival and cellular metabolic homeostasis in response to various stresses, such as nutrient deprivation and the accumulation of damaged organelles. In general, autophagy flux consists of four steps: (1) initiation (formation of phagophore), (2) maturation and completion of autophagosome, (3) fusion of autophagosomes with lysosomes (formation of autolysosome), and (4) degradation of intravesicular components within autolysosomes. The number of genes and reagents that modulate autophagy is increasing. Investigation of their effect on autophagy flux is critical to understanding the roles of autophagy in many physiological and pathological processes. In this review, we summarize and discuss ways to analyze autophagy flux quantitatively and qualitatively with the use of imaging tools. The suggested imaging method can help estimate whether each modulator is an inhibitor or a promoter of autophagy and elucidate the mode of action of specific genes and reagents on autophagy processes.

Positron emission tomography and magnetic resonance imaging

  • Yim, Min Su;Ryu, Eun Kyoung
    • Journal of Radiopharmaceuticals and Molecular Probes
    • /
    • v.2 no.1
    • /
    • pp.3-8
    • /
    • 2016
  • Molecular imaging technologies have been used to provide a new pathway for therapies and diagnosis of human disease. Especially, imaging probes have been much development in the molecular imaging field. Combining imaging probes for positron emission tomography (PET) and magnetic resonance imaging (MRI) have suggested the potential of multiple methods in living body. This review discusses the cancer or lymph node-targeting probes that are suitable for PET/MRI based diagnosis.

Review of Photoacoustic Imaging for Imaging-Guided Spinal Surgery

  • Han, Seung Hee
    • Neurospine
    • /
    • v.15 no.4
    • /
    • pp.306-322
    • /
    • 2018
  • This review introduces the current technique of photoacoustic imaging as it is applied in imaging-guided surgery (IGS), which provides the surgeon with image visualization and analysis capabilities during surgery. Numerous imaging techniques have been developed to help surgeons perform complex operations more safely and quickly. Although surgeons typically use these kinds of images to visualize targets hidden by bone and other tissues, it is nonetheless more difficult to perform surgery with static reference images (e.g., computed tomography scans and magnetic resonance images) of internal structures. Photoacoustic imaging could enable real-time visualization of regions of interest during surgery. Several researchers have shown that photoacoustic imaging has potential for the noninvasive diagnosis of various types of tissues, including bone. Previous studies of the surgical application of photoacoustic imaging have focused on cancer surgery, but photoacoustic imaging has also recently attracted interest for spinal surgery, because it could be useful for avoiding pedicle breaches and for choosing an appropriate starting point before drilling or pedicle probe insertion. This review describes the current instruments and clinical applications of photoacoustic imaging. Its primary objective is to provide a comprehensive overview of photoacoustic IGS in spinal surgery.

Improving Imaging Quality Assessment of Cabinet X-Ray Security Systems (캐비닛 엑스선 검색장비 이미지품질평가 고도화 방안 연구)

  • Yoon, Yeon Ah;Jung, Jin Hyeong;Kim, Yong Soo
    • Journal of Korean Society for Quality Management
    • /
    • v.49 no.1
    • /
    • pp.47-60
    • /
    • 2021
  • Purpose: This study proposes methods and procedures for evaluating imaging security systems quality of cabinet x-ray screening system to enhance performance certification technology. Also, conducted a comparative analysis of the literature of test-kit for imaging security quality evaluation. Methods: Comparative analysis of the test-kits and related documents for image quality assessment of cabinet x-ray screening equipment. This allows assessment items were selected and the methods for each assessment item were proposed. In addition, the configuration method of the assessment team was established by applying the technology readiness assessment(TRA). Results: Four of the assessment items were selected when estimate image quality by a comparative analysis of literature. For each assessment item, the evaluation method and minimum level of availability were determined. Finally, this paper proposes an imaging quality assessment of cabinet X-ray imaging security systems. Conclusion: Development of imaging security systems evaluation procedures for cabinet X-ray screening systems can be help improve performance certification of aviation security equipment.

Contrast-enhanced US of the liver mass : Quantitative Analysis (초음파 조영제를 이용한 간종양의 유형별 소견 고찰)

  • Kim Yun-Min;Han Jung-Hwan;Kim Dong-Hwan;Park Won-Sik
    • Journal of The Korean Radiological Technologist Association
    • /
    • v.27 no.2
    • /
    • pp.148-156
    • /
    • 2001
  • Ⅰ. Purpose : To determine echo value and duration of contrast enhancement of liver mass on contrast-enhanced US with Levovist by quantitative analysis. Ⅱ. Materials and Methods : Twenty three patients with liver mass were prospectively evaluated with cont

  • PDF

Tricuspid Valve Imaging and Right Ventricular Function Analysis Using Cardiac CT and MRI

  • Yura Ahn;Hyun Jung Koo;Joon-Won Kang;Dong Hyun Yang
    • Korean Journal of Radiology
    • /
    • v.22 no.12
    • /
    • pp.1946-1963
    • /
    • 2021
  • Cardiac computed tomography (CT) and cardiac magnetic resonance imaging (CMR) can reveal the detailed anatomy and function of the tricuspid valve and right ventricle (RV). Quantification of tricuspid regurgitation (TR) and analysis of RV function have prognostic implications. With the recently available transcatheter treatment options for diseases of the tricuspid valve, evaluation of the tricuspid valve using CT and CMR has become important in terms of patient selection and procedural guidance. Moreover, CT enables post-procedural investigation of the causes of valve dysfunction, such as pannus or thrombus. This review describes the anatomy of the tricuspid valve and CT and CMR imaging protocols for right heart evaluation, including RV function and TR analyses. We also demonstrate the pre-procedural planning for transcatheter treatment of TR and imaging of postoperative complications using CT.

CBCT Imaging for Dental Implants (임상가를 위한 특집 2 - 임플란트시술을 위한 CBCT의 활용)

  • An, Seo-Young
    • The Journal of the Korean dental association
    • /
    • v.50 no.4
    • /
    • pp.189-195
    • /
    • 2012
  • Various imaging modalities have been used for dental implant assessment in the different stages of implant treatment. Basic imaging, such as panoramic and periapical radiographs, are generally useful and cost-effective but do not provide the cross-sectional visualization or interactive image analysis that can be obtained with more sophisticated imaging techniques, such as Cone-Beam Computed Tomography(CBCT) imaging. This article includes the applications of CBCT imaging and their diagnostic contribution to presurgical evaluation, treatment planning, and postoperative assessment of dental implants.

Practical Approach for the Clinical Use of Dopamine Transporter Imaging (도파민 운반체 영상의 임상이용을 위한 실제적 접근)

  • Kim, Jae-Seung
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.42 no.6
    • /
    • pp.425-434
    • /
    • 2008
  • Dopamine transporter imaging is useful in the diagnosis of Parkinson's disease and the most successful technique in the clinical use of neuroreceptor imaging. Recently, several radiopharmaceuticals including I-123 FP-CIT, Tc-99m TRODAT, and F-18 FP-CIT for dopamine transporter imaging have been approved for the routine clinical use in several European countries, Taiwan and Korea, respectively. This review summarized the practical issue for the routine clinical examination of dopamine transporter imaging.