Imaging Feature of Radiation Induced Lung Disease (방사선 폐손상의 방사선학적 소견)

  • Lee, Jae Gyo;Rho, Byeung Hak;Chang, Jae Chun;Kim, Myung Se
    • Journal of Yeungnam Medical Science
    • /
    • v.17 no.2
    • /
    • pp.146-154
    • /
    • 2000
  • Background and Purpose: Radioopaque lesions are commonly seen in patients who received thoracic radiotherapy for various kinds of thoracic neoplasm, But therir exact diagnos are sometimes uncertain. Patients and Methods: We examined simple chest radiograph and computed tomogram(CT) of 69 patients who received thoracic radiotherapy for lung cancer and were follow up at least 6 months in Yeungnam University Medical Center. Results: Of the 69 patients. thirty-eight patients showed radioopaque lesions in their chest radiographs except radiation fibrosis; radiation pneumonitis was witnessed in 24 patients. infectious pneumonia in 8 patients, and recurrence in 6 patients. In radiation pneumonitis patients, the pneumonitis occurred usually between 50 to 130 days after receiving radiation therapy, and interval between pneumonitis and fibrosis is 21 to 104 days. Simple chest radiographs of radiation pneumonitis(24 patients) represented ground glass opacities or consolidation in 4 cases(type I, 17%), reticular of reticulonodular opacities in 10 cases(type II, 42%), irregular patchy consolidations in 2 cases( type III, 8%), and consolidation with fibrosis in 8 cases(type IV, 33%), CT represent ground glass opacities or consolidation in 5 cases(type I, 29%), irregular nodular opacities in 3 cases(type II, 19%), irregular opacity beyond radiation fields in 3 cases(type III, 18%), and consolidation with fibrosis in 6 cased(type IV, 35%). The CT of four patients who represented type II on simple chest radiographs reveal type I and III, and CT of two patients with clinical symptoms who had no abnormal finding on simple radiograph revealed type I. Conclusions: In conclusion, computed tomogram is superior to the simple radiograph when trying to understand the pathologic process of radiation pneumonitis and provide confidence in the diagnosis of radiation induced lung disease.

  • PDF

A study for detection of melt flow zone about polyethylene butt fusion joints (폴리에틸렌 배관 버트융착부 열용융거리 측정에 대한 연구)

  • Kil, Seonghee;Kim, Younggu;Jo, NYoungdo;Lee, Yeonjae
    • Journal of Energy Engineering
    • /
    • v.25 no.4
    • /
    • pp.103-109
    • /
    • 2016
  • Polyethylene pipes has useful benefits which are anti-corrosive and flexible material, so it is used to gas pipes but also class 3 water pipes of nuclear power plant, process pipes of petrochemical plant and chemical plant. So the usage of polyethylene pipes is widely increased. But it has been limited for the usage of polyethylene, because it can not be directly detected to fusion joints by using non destructive evaluation. Polyethylene pipes are connected by two methods, one is butt fusion and the other is electrofusion. Butt fusion is widely used to connecting the pipes. It is proposed to method for determining the reliability of joints in this study that is detection of the melt flow zone at fusion joints. In this study, middle density polyethylene is used, outside diameter of the test specimen is 225mm and thickness is 20.5mm. Speed of ultrasonic of this test specimen is 2,200m/s. Test specimens were fabricated by varying the heating time which means from 0% to 130% applying time through heating plate to polyethylene for detecting melt flow zone. Also 4 additional test specimens were made, one was made that not scrapping attached surface of pipes but applying 100% of the proper heating time and the others were made to include of soil, gravel and vinly tape paper at fusion joints, that were also applied 100% of proper heating time. Ultrasonic testing to measure the melt flow zone of 20 test specimens was conducted by using 3.5MHz and 5.0MHz ultrasonic probes and melt flow zone measuring was conducted to three times at different point to one specimen. To differentiate the melt flow zone signal, post image processing was equally conducted to all test results and image levels, contrast, sharpen, threshold were adopted to all teat results and the test results were displayed gray scale. From the results, for the shorter heating times the reflection area of multiple echo have been increased, so the data was obtained from the position where it can be eliminated as much as possible. At 80% of proper heating time(168 sec.), the signal of melt flow zone was obtained clearly, so measuring could be conducted. From 7% of proper heating time(15 sec.) to shorter heating times. we could not obtain the signal because test specimen was not fused. From the result, we can verify that measuring of melt flow zone by using phased array ultrasonic imaging method is possible. And we can verify to complete and incomplete butt fusion by measuring the melt flow zone.

The Application of Dynamic Acquisition with Motion Correction for Static Image (동적 영상 획득 방식을 이용한 정적 영상의 움직임 보정)

  • Yoon, Seok-Hwan;Seung, Jong-Min;Kim, Kye-Hwan;Kim, Jae-Il;Lee, Hyung-Jin;Kim, Jin-Eui;Kim, Hyun-Joo
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.1
    • /
    • pp.46-53
    • /
    • 2010
  • Purpose: The static image of nuclear medicine study should be acquired without a motion, however, it is difficult to acquire static image without movement for the serious patients, advanced aged patients. These movements cause decreases in reliability for quantitative and qualitative analysis, therefore re-examination was inevitable in the some cases. Consequently, in order to improve the problem of motion artifacts, the authors substituted the dynamic acquisition technique for the static acquisition, using motion correction. Materials and Methods: A capillary tube and IEC body phantom were used. First, the static image was acquired for 60 seconds while the dynamic images were acquired with a protocol, 2 sec/frame${\times}$30 frames, under the same parameter and the frames were summed up into one image afterwards. Also, minimal motion and excessive motion were applied during the another dynamic acquisition and the coordinate correction was applied towards X and Y axis on the frames where the motion artifact occurred. But the severe blurred images were deleted. Finally, the resolution and counts were compared between the static image and the summed dynamic images which before and after applying motion correction, and the signal of frequency was analysed after frequency spatial domain was transformed into 2D FFT. Supplementary examination, the blind test was performed by the nuclear medicine department staff. Results: First, the resolution in the static image and summed dynamic image without motion were 8.32 mm, 8.37 mm on X-axis and 8.30 mm, 8.42 mm on Y-axis, respectively. The counts were 484 kcounts, 485 kcounts each, so there was nearly no difference. Secondly, the resolution in the image with minimal motion applying motion correction was 8.66 mm on X-axis, 8.85 mm on Y-axis and had 469 kcounts while the image without motion correction was 21.81 mm, 24.02 mm and 469 kcounts in order. So, this shows the image with minimal motion applying motion correction has similar resolution with the static image. Lastly, the resolution in the images with excessive motion applying motion correction were 9.09 mm on X-axis, 8.83 mm on Y-axis and had 469 kcounts while the image without motion correction was 47.35 mm, 40.46 mm and 255 kcounts in order. Although there was difference in counts because of deletion of blurred frames, we could get similar resolution. And when the image was transformed into frequency, the high frequency was decreased by the movement. However, the frequency was improved again after motion correction. In the blind test, there was no difference between the image applying motion correction and the static image without motion. Conclusion: There was no significant difference between the static image and the summed dynamic image. This technique can be applied to patients who may have difficulty remaining still during the imaging process, so that the quality of image can be improved as well as the reliance for analysis of quantity. Moreover, the re-examination rate will be considerably decreased. However, there is a limit of motion correction, more time will be required to successfully image the patients applying motion correction. Also, the decrease of total counts due to deletion of the severe blurred images should be calculated and the proper number of frames should be acquired.

  • PDF

The significance of corpus callosal size in the estimation of neurologically abnormal infants (신경학적인 결함이 있었던 영아의 예후 판단에서 뇌량 크기의 중요성)

  • Yu, Seung Taek;Lee, Chang Woo
    • Clinical and Experimental Pediatrics
    • /
    • v.51 no.11
    • /
    • pp.1205-1210
    • /
    • 2008
  • Purpose : The development of the corpus callosum occupies the entire period of cerebral formation. The myelination pattern on magnetic resonance imaging (MRI) is very useful to evaluate neurologic development and to predict neurologic outcome in high risk infants. The thickness of the corpus callosum is believed to depend on the myelination process. It is possible to calculate the length and thickness of the corpus callosum on MRI. Thus, we can quantitatively evaluate the development of the corpus callosum. We investigated the clinical significance of measuring various portions of the corpus callosum in neonate with neurologic disorders such as hypoxic brain damage and seizure disorder. Methods : Forty-two neonates were evaluated by brain MRI. We measured the size of the genu, body, transitional zone, splenium, and length of the corpus callosum. Each measurement was divided by the total length of the corpus callosum to obtain its corrected size. The ratio of corpus callosal length and the anteroposterior diameter of the brain was also measured. Results : There was no statistical significance in the sample size of each part of the corpus callosum. However, the corrected size or the ratio of body of the corpus callosum correlated with periventricular leukomalacia and hypoxic ischemic encephalopathy. Conclusion : The abnormal size of the corpus callosum showed a good correlation with periventricular leukomalacia and hypoxic ischemic encephalopathy in neonates. We can predict clinical neurological problems by estimation of the corpus callosum in the neonatal period.

Cystic Diseases of the Kidney in Children (소아의 낭포성 신질환)

  • Lee Ji-Suk;Rho Kwang-Sik;Kim Ji-Hong;Lee Jae-Seung;Kim Pyung-Kil
    • Childhood Kidney Diseases
    • /
    • v.1 no.2
    • /
    • pp.144-150
    • /
    • 1997
  • Purpose : The kidney is one of the most common sites of cyst formation. Cystic diseases of the kidney are a diverse group of clinicopathologic entities and variable prognosis. They span a wide range of both age of presentation and severity of the renal disease. And many of them are systemic disorders, sharing similar process of cyst formation in other organs. Recently, development of imaging studies has been contributing widely to the diagnosis of the diseases. Treatment, however, is not established satisfactorily. We performed this study to evaluate the occurrence and treatment of cystic diseases of the kidney. Methods : We reviewed retrospectively the medical records of 44 patients with cystic diseases of the kidney in the Department of Pediatrics, during last 11 years. Results : In the 44 patients with cystic diseases of the kidney, 31 patients(71%) had multicystic dysplastic kidney and 11(35%) of them received nephrectomy due to differentiation from neoplasms or severe abdominal distension. Seven patients(16%) had polycystic kidney disease, and all of them were infantile type. Five patients(11%) were diagnosed as having a simple renal cysts. Progression to renal failure was noted in none of the cases. In 14(32%) out of total 44 patients, the diagnosis was made in neonatal or infantile pelted. Conclusion : The incidence of cystic diseases of the kidney appeared very low, but further investigation on their pathogenesis, classification, and indication of treatment is needed.

  • PDF

Optimization of Subtraction Brain Perfusion SPECT with Basal/Acetazolamide Consecutive Acquisition (기저/아세타졸아미드 부하 연속 촬영 뇌관류 SPECT 최적화)

  • Lee, Dong-Soo;Lee, Tae-Hoon;Kim, Kyeong-Min;Chung, June-Key;Lee, Myung-Chul;Koh, Chang-Soon
    • The Korean Journal of Nuclear Medicine
    • /
    • v.31 no.3
    • /
    • pp.330-338
    • /
    • 1997
  • This study investigated the method to adjust acquisition time(a) and injection dose (i) to make the best basal and subtraction images in consecutive SPECT. Image quality was assumed to be mainly affected by signal to noise ratio(S/N). Basal image was subtracted from the second image consecutively acquired at the same position. We calculated S/N ratio in basal SPECT images($S_1/N_1$) and subtraction SPECT images(Ss/Ns) to find a(time) and i(dose) to maximize S/N of both images at the same time. From phantom images, we drew the relation of image counts and a(time) and i(dose) in our system using fanbeam-high-resolution collimated triple head SPECT. Noise by imaging process depended on Poisson distribution. We took maximum tolerable duration of consecutive acquisition as 30 minutes and maximum injectible dose as 1,850MBq(50 mCi)(sum of two injections) per study. Counts of second-acquired image($S_2$), counts($S_s$) and noise($N_s$) of subtraction SPECT were as follows. $C_1$ was the coefficient of measurement with our system. $$S_2=S_1{\cdot}(\frac{30-a}{a})+background{\cdot}(1-\frac{30-a}{a})+C_1{\cdot}(30-a){\cdot}{\epsilon}{\cdot}(50-i)$$ $$Ss=S_2-\{S_1{\cdot}(\frac{30-a}{a})+background{\cdot}(1-\frac{(30-a)}{a})\}$$ $$Ns={\sqrt{N_2^2+N_1^2{\cdot}\frac{(30-a)^2}{a^2}}={\sqrt{S_2+S_1{\cdot}\frac{(30-a)^2}{a^2}}$$ In case of rest/acetazolamide study, effect(${\epsilon}$) of acetazolamide to increase global brain uptake of Tc-99m-HMPAO could be 1.5 or less. Varying ${\epsilon}$ from 1 to 1.5, a(time) and i(dose) pair to maximize both $S_1/N_l$ and Ss/Ns was determined. 15 mCi/17 min and 35mCi/13min was the best a(time) and i(dose) pair for rest/acetazolamide study(when ${\epsilon}$ were 1.2) and came to be used for our clinical routine after this study. We developed simple method to maximize S/N ratios of basal and subtraction SPECT from consecutive acquisition. This method could be applied to ECD/HMPAO and brain activation studies as well as rest/acetazolamide studies.

  • PDF

True Orthoimage Generation from LiDAR Intensity Using Deep Learning (딥러닝에 의한 라이다 반사강도로부터 엄밀정사영상 생성)

  • Shin, Young Ha;Hyung, Sung Woong;Lee, Dong-Cheon
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.38 no.4
    • /
    • pp.363-373
    • /
    • 2020
  • During last decades numerous studies generating orthoimage have been carried out. Traditional methods require exterior orientation parameters of aerial images and precise 3D object modeling data and DTM (Digital Terrain Model) to detect and recover occlusion areas. Furthermore, it is challenging task to automate the complicated process. In this paper, we proposed a new concept of true orthoimage generation using DL (Deep Learning). DL is rapidly used in wide range of fields. In particular, GAN (Generative Adversarial Network) is one of the DL models for various tasks in imaging processing and computer vision. The generator tries to produce results similar to the real images, while discriminator judges fake and real images until the results are satisfied. Such mutually adversarial mechanism improves quality of the results. Experiments were performed using GAN-based Pix2Pix model by utilizing IR (Infrared) orthoimages, intensity from LiDAR data provided by the German Society for Photogrammetry, Remote Sensing and Geoinformation (DGPF) through the ISPRS (International Society for Photogrammetry and Remote Sensing). Two approaches were implemented: (1) One-step training with intensity data and high resolution orthoimages, (2) Recursive training with intensity data and color-coded low resolution intensity images for progressive enhancement of the results. Two methods provided similar quality based on FID (Fréchet Inception Distance) measures. However, if quality of the input data is close to the target image, better results could be obtained by increasing epoch. This paper is an early experimental study for feasibility of DL-based true orthoimage generation and further improvement would be necessary.

Baseline Survey Seismic Attribute Analysis for CO2 Monitoring on the Aquistore CCS Project, Canada (캐나다 아퀴스토어 CCS 프로젝트의 이산화탄소 모니터링을 위한 Baseline 탄성파 속성분석)

  • Cheong, Snons;Kim, Byoung-Yeop;Bae, Jaeyu
    • Economic and Environmental Geology
    • /
    • v.46 no.6
    • /
    • pp.485-494
    • /
    • 2013
  • $CO_2$ Monitoring, Mitigation and Verification (MMV) is the essential part in the Carbon Capture and Storage (CCS) project in order to assure the storage permanence economically and environmentally. In large-scale CCS projects in the world, the seismic time-lapse survey is a key technology for monitoring the behavior of injected $CO_2$. In this study, we developed a basic process procedure for 3-D seismic baseline data from the Aquistore project, Estevan, Canada. Major target formations of Aquistore CCS project are the Winnipeg and the Deadwood sandstone formations located between 1,800 and 1,900 ms in traveltime. The analysis of trace energy and similarity attributes of seismic data followed by spectral decomposition are carried out for the characterization of $CO_2$ injection zone. High trace energies are concentrated in the northern part of the survey area at 1,800 ms and in the southern part at 1,850 ms in traveltime. The sandstone dominant regions are well recognized with high reflectivity by the trace energy analysis. Similarity attributes show two structural discontinuities trending the NW-SE direction at the target depth. Spectral decomposition of 5, 20 and 40 Hz frequency contents discriminated the successive E-W depositional events at the center of the research area. Additional noise rejection and stratigraphic interpretation on the baseline data followed by applying appropriate imaging technique will be helpful to investigate the differences between baseline data and multi-vintage monitor data.

Space Development and Law in Asia (아시아의 우주개발과 우주법)

  • Cho, Hong-Je
    • The Korean Journal of Air & Space Law and Policy
    • /
    • v.28 no.2
    • /
    • pp.349-384
    • /
    • 2013
  • The Sputnik 1 launching in 1957 made the world recognize the necessity of international regulations on space development and activities in outer space. The United Nations established COPUOS the very next year, and adopted the mandate to examine legal issues concerning the peaceful uses of outer space. At the time, the military sector of the U.S.A. and the Soviet Union were in charge of the space development and they were not welcomed to discuss the prohibition of the military uses of outer space at the legal section in the COPUOS. Although both countries had common interests in securing the freedom of military uses in outer space. As the social and economic benefits derived from space activities have become more apparent, civil expenditures on space activities have continued to increase in several countries. Virtually all new spacefaring states explicitly place a priority on space-based applications to support social and economic development. Such space applications as satellite navigation and Earth imaging are core elements of almost every existing civil space program. Likewise, Moon exploration continues to be a priority for such established spacefaring states as China, Russia, India, and Japan. Recently, Companies that manufacture satellites and ground equipment have also seen significant growth. On 25 February 2012 China successfully launched the eleventh satellite for its indigenous global navigation and positioning satellite system, Beidou. Civil space activities began to grow in China when they were allocated to the China Great Wall Industry Corporation in 1986. China Aerospace Corporation was established in 1993, followed by the development of the China National Space Administration. In Japan civil space was initially coordinated by the National Space Activities Council formed in 1960. Most of the work was performed by the Institute of Space and Aeronautical Science of the University of Tokyo, the National Aerospace Laboratory, and, most importantly, the National Space Development Agency. In 2003 all this work was assumed by the Japanese Aerospace Exploration Agency(JAXA). Japan eases restrictions on military space development. On 20 June 2012 Japan passed the Partial Revision of the Cabinet Establishment Act, which restructured the authority to regulate Japanese space policy and budget, including the governance of the JAXA. Under this legislation, the Space Activities Commission of the Ministry of Education, Culture, Sports, Science, and Technology, which was responsible for the development of Japanese space program, will be abolished. Regulation of space policy and budget will be handed over to the Space Strategy Headquarter formed under the Prime Minister's Cabinet. Space Strategy will be supported by a Consultative Policy Commission as an academics and independent observers. By revoking Article 4 (Objectives of the Agency) of a law that previously governed JAXA and mandated the development of space programs for "peaceful purposes only," the new legislation demonstrates consistency with Article 2 of the 2008 Basic Space Law. In conformity with the principles laid down in the 1967 Outer Space Treaty JAXA is now free to pursue the non-aggressive military use of space. New legislation is the culmination of a decade-long process that sought ways to "leverage Japan's space development programs and technologies for security purposes, to bolster the nation's defenses in the face of increased tensions in East Asia." In this connection it would also be very important and necessary to create an Asian Space Agency(ASA) for strengthening cooperation within the Asian space community towards joint undertakings.

  • PDF

Assessment of Attenuation Correction Techniques with a $^{137}Cs$ Point Source ($^{137}Cs$ 점선원을 이용한 감쇠 보정기법들의 평가)

  • Bong, Jung-Kyun;Kim, Hee-Joung;Son, Hye-Kyoung;Park, Yun-Young;Park, Hae-Joung;Yun, Mi-Jin;Lee, Jong-Doo;Jung, Hae-Jo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.39 no.1
    • /
    • pp.57-68
    • /
    • 2005
  • Purpose: The objective of this study was to assess attenuation correction algorithms with the $^{137}Cs$ point source for the brain positron omission tomography (PET) imaging process. Materials & Methods: Four different types of phantoms were used in this study for testing various types of the attenuation correction techniques. Transmission data of a $^{137}Cs$ point source were acquired after infusing the emission source into phantoms and then the emission data were subsequently acquired in 3D acquisition mode. Scatter corrections were performed with a background tail-fitting algorithm. Emission data were then reconstructed using iterative reconstruction method with a measured (MAC), elliptical (ELAC), segmented (SAC) and remapping (RAC) attenuation correction, respectively. Reconstructed images were then both qualitatively and quantitatively assessed. In addition, reconstructed images of a normal subject were assessed by nuclear medicine physicians. Subtracted images were also compared. Results: ELEC, SAC, and RAC provided a uniform phantom image with less noise for a cylindrical phantom. In contrast, a decrease in intensity at the central portion of the attenuation map was noticed at the result of the MAC. Reconstructed images of Jaszack and Hoffan phantoms presented better quality with RAC and SAC. The attenuation of a skull on images of the normal subject was clearly noticed and the attenuation correction without considering the attenuation of the skull resulted in artificial defects on images of the brain. Conclusion: the complicated and improved attenuation correction methods were needed to obtain the better accuracy of the quantitative brain PET images.