• Title/Summary/Keyword: Imaging Module

Search Result 130, Processing Time 0.03 seconds

The Development of Infrared Thermal Imaging Safety Diagnosis System Using Pearson's Correlation Coefficient (피어슨 상관계수를 이용한 적외선 열화상 안전 진단 시스템 개발)

  • Jung, Jong-Moon;Park, Sung-Hun;Lee, Yong-Sik;Gim, Jae-Hyeon
    • Journal of the Korean Solar Energy Society
    • /
    • v.39 no.6
    • /
    • pp.55-65
    • /
    • 2019
  • With the rapid development of the national industry, the importance of electrical safety was recognized because of a lot of new electrical equipment are installing and the electrical accidents have been occurring annually. Today, the electrical equipments is inspect by using the portable Infrared thermal imaging camera. but the most negative element of using the camera is inspected for only state of heating, the reliable diagnosis is depended with inspector's knowledge, and real-time monitoring is impossible. This paper present the infrared thermal imaging safety diagnosis system. This system is able to monitor in real time, predict the state of fault, and diagnose the state with analysis of thermal and power data. The system consists of a main processor, an infrared camera module, the power data acquisition board, and a server. The diagnostic algorithm is based on a mathematical model designed by analyzing the Pearson's Correlation Coefficient between temperature and power data. To test the prediction algorithm, the simulations were performed by damaging the terminals or cables on the switchboard to generate a large amount of heat. Utilizing these simulations, the developed prediction algorithm was verified.

Multi-Channel Data Link Module Design for High Speed Image Data Transmission from Spaceborne SAR (위성 영상 레이다의 고속자료 전송을 위한 멀티 채널 데이터 전송 모듈 설계와 성능 특징)

  • Kwag, Young-Kil
    • Journal of Advanced Navigation Technology
    • /
    • v.5 no.2
    • /
    • pp.149-157
    • /
    • 2001
  • A high speed data link capability is one of the critical factors in determining the performance of the spaceborne SAR system with high resolution. It is due to the strict requirement for the real-time data transmission from a series of massive raw image data of spaceborne SAR to the ground station in a limited time of mission. In this paper, based on the data link model characterized by the spaceborne small SAR system, the high rate multi-channel data link module is designed including link storage, link processor, transmitter, and wide-angle antenna. The design results are presented with the performance analysis on the data link budget as well as the multi-mode data rate in association with the SAR imaging mode of operation from high resolution to the wide swath.

  • PDF

Header Data Interpreting S/W Design for MSC(Multi-Spectral Camera) image data

  • Kong Jong-Pil;Heo Haeng-Pal;Kim YoungSun;Park Jong-Euk;Youn Heong-Sik
    • Proceedings of the KSRS Conference
    • /
    • 2004.10a
    • /
    • pp.436-439
    • /
    • 2004
  • Output data streams of the MSC contain flags, Headers and image data according to the established protocols and data formats. Especially the Header added to each data lines contain information of a line sync, a line counter and, ancillary data which consist of ancillary identification bit and one ancillary data byte. This information is used by ground station to calculate the geographic coordinates of the image and get the on-board time and several EOS(Electro-Optical Subsystem) parameters used at the time of imaging. Therefore, the EGSE(Electrical Ground Supporting Equipment) that is used for testing MSC has to have functions of interpreting and displaying this Header information correctly following the protocols. This paper describes the design of the header data processing module which is in EOS­EGSE. This module provides users with various test functions such as header validation, ancillary block validation, line-counter and In-line counter validation checks which allow convenient and fast test on imagery data.

  • PDF

Boundary and Reverse Attention Module for Lung Nodule Segmentation in CT Images (CT 영상에서 폐 결절 분할을 위한 경계 및 역 어텐션 기법)

  • Hwang, Gyeongyeon;Ji, Yewon;Yoon, Hakyoung;Lee, Sang Jun
    • IEMEK Journal of Embedded Systems and Applications
    • /
    • v.17 no.5
    • /
    • pp.265-272
    • /
    • 2022
  • As the risk of lung cancer has increased, early-stage detection and treatment of cancers have received a lot of attention. Among various medical imaging approaches, computer tomography (CT) has been widely utilized to examine the size and growth rate of lung nodules. However, the process of manual examination is a time-consuming task, and it causes physical and mental fatigue for medical professionals. Recently, many computer-aided diagnostic methods have been proposed to reduce the workload of medical professionals. In recent studies, encoder-decoder architectures have shown reliable performances in medical image segmentation, and it is adopted to predict lesion candidates. However, localizing nodules in lung CT images is a challenging problem due to the extremely small sizes and unstructured shapes of nodules. To solve these problems, we utilize atrous spatial pyramid pooling (ASPP) to minimize the loss of information for a general U-Net baseline model to extract rich representations from various receptive fields. Moreover, we propose mixed-up attention mechanism of reverse, boundary and convolutional block attention module (CBAM) to improve the accuracy of segmentation small scale of various shapes. The performance of the proposed model is compared with several previous attention mechanisms on the LIDC-IDRI dataset, and experimental results demonstrate that reverse, boundary, and CBAM (RB-CBAM) are effective in the segmentation of small nodules.

Automatic Detection of Malfunctioning Photovoltaic Modules Using Unmanned Aerial Vehicle Thermal Infrared Images

  • Kim, Dusik;Youn, Junhee;Kim, Changyoon
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.34 no.6
    • /
    • pp.619-627
    • /
    • 2016
  • Cells of a PV (photovoltaic) module can suffer defects due to various causes resulting in a loss of power output. As a malfunctioning cell has a higher temperature than adjacent normal cells, it can be easily detected with a thermal infrared sensor. A conventional method of PV cell inspection is to use a hand-held infrared sensor for visual inspection. The main disadvantages of this method, when applied to a large-scale PV power plant, are that it is time-consuming and costly. This paper presents an algorithm for automatically detecting defective PV panels using images captured with a thermal imaging camera from an UAV (unmanned aerial vehicle). The proposed algorithm uses statistical analysis of thermal intensity (surface temperature) characteristics of each PV module to verify the mean intensity and standard deviation of each panel as parameters for fault diagnosis. One of the characteristics of thermal infrared imaging is that the larger the distance between sensor and target, the lower the measured temperature of the object. Consequently, a global detection rule using the mean intensity of all panels in the fault detection algorithm is not applicable. Therefore, a local detection rule was applied to automatically detect defective panels using the mean intensity and standard deviation range of each panel by array. The performance of the proposed algorithm was tested on three sample images; this verified a detection accuracy of defective panels of 97% or higher. In addition, as the proposed algorithm can adjust the range of threshold values for judging malfunction at the array level, the local detection rule is considered better suited for highly sensitive fault detection compared to a global detection rule. In this study, we used a panel area extraction method that we previously developed; fault detection accuracy would be improved if panel area extraction from images was more precise. Furthermore, the proposed algorithm contributes to the development of a maintenance and repair system for large-scale PV power plants, in combination with a geo-referencing algorithm for accurate determination of panel locations using sensor-based orientation parameters and photogrammetry from ground control points.

Design of DICOM Standard Interface Module for Medical Image Standardization (의료영상 표준화를 위한 DICOM 표준 인터페이스 모듈 설계)

  • Kim, Sung-Hyun;Jeon, Jae-Hwan;Kim, Gwan-Hyung;Kang, Sung-In;Oh, Am-Suk
    • Proceedings of the Korean Society of Computer Information Conference
    • /
    • 2010.07a
    • /
    • pp.221-224
    • /
    • 2010
  • PACS(Picture Archiving Communication System)를 바탕으로 하는 DICOM(Digital Imaging and Communications in Medicine)은 주요 의료영상장비들 사이에 데이터와 영상을 효율적으로 교환하고 전송할 수 있도록 마련한 표준안으로 현재 대부분의 최신형 의료영상장비(CT, MR, DSA, CR(Computed Radiology), 초음파검사, 핵의학검사, 내시경검사, 조직병리검사, 등)들은 의료 영상 분야의 국제 표준인 DICOM 표준방식에 의해 영상을 제공하고 있다. 최근 이러한 의료영상장비들은 독립적으로 사용하기보다는 의료수술 모니터링 장비 등의 비 의학영상장비와 서로 연계하여 사용하는 경우가 많아졌다. 그러나 이러한 의료수술 모니터링 장비들은 DICOM 표준 데이터를 고려하지 못하므로 PACS를 통한 데이터 연계에 어려움이 있다. 따라서 본 논문에서는 표준 DICOM 포맷과 의료수술 모니터링 장비의 데이터 구조를 분석하여 non-DICOM 의료수술 모니터링 장비의 PACS 연동을 위한 방안을 제안하였다.

  • PDF

Research on Fourth Harmonic Mixer at W Band in the Imaging System

  • Xiang, Bo;Dou, Wenbin;He, Minmin;Wang, Zongxin
    • Journal of electromagnetic engineering and science
    • /
    • v.10 no.4
    • /
    • pp.316-321
    • /
    • 2010
  • This paper presents a novel fourth harmonic mixer with new structure. The traditional 3-ports fourth harmonic mixer and the novel fourth harmonic mixer are designed by ADS, HFSS and CST simulator. The mixers have been fabricated and tested. The size of the traditional 3-ports fourth harmonic mixer is $12{\times}15$ mm, and the best conversion loss is 18.7 dB according to the measurement. Since the traditional 3-port mixer size is too large to be ranked, we design a novel fourth harmonic mixer for imaging system. The width of the mixing module in the novel fourth harmonic mixer is only 3.65 mm, and this size is fully capable to meet the mixer unit space which is not greater than 5 mm. The simulation result shows that the mixer has good performance, and the experiment result shows that the best conversion loss of the novel fourth harmonic mixer is 16.3 dB at RF signal of 91.3 GHz.

Investigation of an Infrared Temperature Measurement System for Thermal Safety Verification of Plasma Skin Treatment Devices

  • Choi, Jong-ryul;Kim, Wookeun;Kang, Bongkeun;Song, Tae-Ha;Baek, Hee Gyu;Han, Yeong Gil;Park, Jungmoon;Seo, Soowon
    • Current Optics and Photonics
    • /
    • v.1 no.5
    • /
    • pp.500-504
    • /
    • 2017
  • In this paper, we developed a temperature measurement system based on an infrared temperature imaging module for thermal safety verification of a plasma skin treatment device (PSTD). We tested a pilot product of the low-temperature PSTD using the system, and the temperature increase of each plasma torch was well-monitored in real-time. Additionally, through the approximation of the temperature increase of the plasma torches, a certain limitation of the plasma treatment time on skin was established with the International Electrotechnical Commission (IEC) guideline. We determined an appropriate plasma treatment time ($T_{Safe}$ < 24 minutes) using the configured temperature measurement system. We believe that the temperature measurement system has a potential to be employed for testing thermal safety and suitability of various medical devices and industrial instruments.

AN OPTICAL FIBER FEED LITTROW-MOUNTED SPECTROMETER (광섬유 피드 리트로마운트형 분광계)

  • Bae, J.H.;Song, J.W.;Yoon, T.S.
    • Publications of The Korean Astronomical Society
    • /
    • v.27 no.3
    • /
    • pp.87-93
    • /
    • 2012
  • A low-dispersion fiber feed Littrow-mounted grating spectrometer for education was designed and fabricated. The dispersion element is a reflective type blazed grating Edmundoptics NT 46-075 (spatial frequency 600 lines/mm, dimension $30mm{\times}30mm$, blazed angle 8.6 degree). The optical fiber coupler module for optical guiding from telescope to spectrometer is composed of a multi-mode FC connector - FC connector optical fiber patch cord (core/cladding diameter $50{\mu}m/125{\mu}m$) and two 1.25" throw-tube couplers. The lens for collimating and imaging is a general purpose focal length 50 mm camera lens (f/1.8). The device for optical path control is a rectangular prism (size $25mm{\times}25mm$). The imaging camera sensor is a Meade DSI Pro 2 CCD sensor (black and white, $752{\times}582$ pixels and pixel size $8.3{\mu}m{\times}8.6{\mu}m$). Softwares for data logging and analysis consist of Meade Autostar Suite, NIH imagej and Vernier Logger Pro 3. The wavelength coverage range of the spectrometer is 205 nm at central wavelength 550 nm. The wavelength resolution is 1.7 nm.

Automated radiosynthesis for the routine production of [18F]FPEB for imaging metabotropic glutamate receptor 5 (mGluRS)

  • Kyung Rok Nam;Sang Jin Han;Kyo Chul Lee;Jae Yong Choi
    • Journal of Radiopharmaceuticals and Molecular Probes
    • /
    • v.8 no.1
    • /
    • pp.3-8
    • /
    • 2022
  • Alteration of the mGluR5 density is closely related to various brain diseases including schizophrenia, depression, Parkinson's disease, and Alzheimer's disease. Therefore, mGluR5 is considered as a valuable imaging biomarker for brain disease and many radiopharmaceuticals have been developed so far. Among them, [18F]FPEB has favorable pharmacokinetic characteristics, and this is the most frequently used radiopharmaceutical for preclinical and clinical studies. In the present study, we want to introduce the optimized radiosynthetic method for the routine production of [18F]FPEB using a GE TRACERlabTM FXFN pro module. In addition, the entire process was monitored with a webcam to solve the problems arising from the synthetic process. As a result, [18F]FPEB was prepared by nucleophilic substitution from its nitro- precursor at 120℃ for 20 min in dimethyl sulfoxide. Radiochemical yield was 13.7 ± 5.1% (decay-corrected, n = 91) with the molar activity of 84 ± 17 GBq/µmol at the end of synthesis. The radiochemical purity was determined to be above 96%. The manufactured [18F]FPEB injection for quality controls were carried out in accordance with an KIRAMS approved protocol, as per ICH and USP guidelines.