• Title/Summary/Keyword: Imaging, Three Dimensional

Search Result 696, Processing Time 0.028 seconds

A Study on the Estimation of Calcaneal Width Using a Correlation of Calcaneal Length and Width (종골 길이와 너비의 상관관계를 이용한 종골 너비 추정에 관한 연구)

  • Chun, Dong-il;Hwang, Shu Chiang;Cho, Jae-ho;Choi, Sung-Woo;Kim, Yong Beom;Won, Sung Hun
    • Journal of Korean Foot and Ankle Society
    • /
    • v.21 no.2
    • /
    • pp.61-65
    • /
    • 2017
  • Purpose: The purpose of this study was to determine the correlation and ratio between the calcaneal length and width for predicting the width of calcaneus. Materials and Methods: A total of 190 feet (190 patients) were included based on computed tomography scans. The length of calcaneus (CL) was measured on the line connecting the center of a circle tangent to the cortical margin in the anterior and posterior parts of the calcaneus in a sagittal plane (W1, W2). The width of the calcaneus was defined as the horizontal line of each part (W1, W2, W3) on the same axial plane. The relationship between the measurement was determined through a correlation analysis. The reliability was assessed based on intraclass correlation coefficients. Results: The CL and widths of calcaneus (W1, W2, W3) had a good positive correlation (r=0.848 [W1/CL], r=0.738 [W2/CL], r=0.769 [W3/CL]; p<0.001). The mean CL and widths ratios were 0.33 (W1/CL), 0.37 (W2/CL), and 0.37 (W3/CL). Using these ratios to estimate the widths by multiplying each ratio by the measured calcaneal length, we found a difference between the estimated calcaneal widths and the actual measured calcaneal widths values was 0.25 mm, 0.43 mm, and 0.16 mm. All measurements showed good-to-excellent inter- and intraobserver reliability. Conclusion: This study analyzed the correlation and ratio between the length and width of the calcaneus. The results will help orthopedic surgeons fixate screws in a stable manner to prevent iatrogenic injuries to the medial neurovascular structures of the calcaneus.

Assessment of bone density changes following two-jaw surgery using multidetector computed tomography: A pilot study

  • Lee, Youngjoo;Park, Jae Hyun;Chang, Na-Young;Lee, Mi-Young;Kim, Bong Chul;Seo, Hye Young;Mangal, Utkarsh;Chae, Jong-Moon
    • The korean journal of orthodontics
    • /
    • v.50 no.3
    • /
    • pp.157-169
    • /
    • 2020
  • Objective: The aim of this retrospective study was to evaluate the pre- and postsurgical bone densities at alveolar and extra-alveolar sites following two-jaw orthognathic surgery. Methods: The sample consisted of 10 patients (mean age, 23.2 years; range, 18.0-27.8 years; 8 males, 2 females) who underwent two-jaw orthognathic surgery. A three-dimensional imaging program (Invivo 5) was used with multidetector computed tomography images taken pre- and postoperatively (obtained 32.3 ± 6.0 days before surgery and 5.8 ± 2.6 days after surgery, respectively) for the measurement of bone densities at the following sites: (1) alveolar bone in the maxilla and mandible, (2) extra-alveolar sites, such as the top of the head, menton (Me), condyle, and the fourth cervical vertebrae (C4). Results: When pre- and postsurgical bone densities were compared, an overall tendency of decrease in bone density was noted. Statistically significant reductions were observed in the densities of cancellous bone at several areas of the maxillary alveolar bone; cortical and cancellous bone in most areas of the mandibular alveolar bone; cortical bone in Me; and cancellous bone in C4. There was no statistically significant difference in bone density in relation to the depth of the alveolar bone. In a comparison of the bone densities between groups with and without genioplasty, there was almost no statistically significant difference. Conclusions: Accelerated tooth movement following orthognathic surgery may be confirmed with reduced bone density. In addition, this study could offer insights into bone metabolism changes following orthognathic surgery, providing direction for further investigations in this field.

Development and application of stent-based image guided navigation system for oral and maxillofacial surgery (구강외과 수술용 스텐트 기반 영상유도 수술 시스템의 개발)

  • Lee, Woo-Jin;Kim, Dae-Seung;Yi, Won-Jin;Lee, Sam-Sun;Choi, Soon-Chul;Heo, Min-Suk;Huh, Kyung-Hoe;Kim, Myung-Jin;Lee, Jee-Ho
    • Imaging Science in Dentistry
    • /
    • v.39 no.3
    • /
    • pp.149-156
    • /
    • 2009
  • Purpose : The purpose of this study was to develop a stent-based image guided surgery system and to apply it to oral and maxillofacial surgeries for anatomically complex sites. Materials and Methods : We devised a patient-specific stent for patient-to-image registration and navigation. Three-dimensional positions of the reference probe and the tool probe were tracked by an optical camera system and the relative position of the handpiece drill tip to the reference probe was monitored continuously on the monitor of a PC. Using 8 landmarks for measuring accuracy, the spatial discrepancy between CT image coordinate and physical coordinate was calculated for testing the normality. Results : The accuracy over 8 anatomical landmarks showed an overall mean of $0.56{\pm}0.16\;mm$. The developed system was applied to a surgery for a vertical alveolar bone augmentation in right mandibular posterior area and possible interior alveolar nerve injury case of an impacted third molar. The developed system provided continuous monitoring of invisible anatomical structures during operation and 3D information for operation sites. The clinical challenge showed sufficient accuracy and availability of anatomically complex operation sites. Conclusion : The developed system showed sufficient accuracy and availability in oral and maxillofacial surgeries for anatomically complex sites.

  • PDF

3D Precision Measurement of Scanning Moire Using Line Scan Camera (라인스캔 카메라를 이용한 3차원 정밀 측정)

  • Kim, Hyun-Ju;Yoon, Doo-Hyun;Kim, Hak-Il
    • Korean Journal of Optics and Photonics
    • /
    • v.19 no.5
    • /
    • pp.376-380
    • /
    • 2008
  • This paper presents the Projection Moire method using a line scan camera. The high resolution feature of a line scan camera makes it possible to scan an image quickly, thus enabling a much quicker 3D profile. This method uses a high resolution line scan camera making it possible to scan an image at high speed simultaneously measuring the 3D profile of a large FOV. When using a high resolution scan camera, a full FOV is scanned, thus requiring just one movement of a projection grating. As a result, the number of grating movements is reduced drastically. The end result is a faster and more accurate 3D measurement. Moving the grating too quickly causes vibration in the imaging system, which will normally be required to apply a stitching technique when using an area scan camera. However the technique is not required when using a line scan camera. Compared with the previous techniques, it has the advantages of simple hardware without moving mechanical parts - single exposure for obtaining three-dimensional information. A method using a high resolution line scan camera can be used in mass production to measure the bump height of wafers or the bump height of package substrates.

Experimental Observation of Instability of Supersonic Submerged Jets (수중초음속제트의 불안정성에 대한 실험적 고찰)

  • 정재권;이대훈;차홍석;박승오;권세진
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.6 no.2
    • /
    • pp.45-52
    • /
    • 2002
  • An experimental investigation on the structure and dynamic behavior of two dimensional over-expanded air jets exiting into water was carried out. The hish speed digital video imaging and static pressure distribution measurement were made to characterize the structure and time-dependant behavior of the jets. Mach number at the jet exit was 2.0 and was slightly less than the value predicted by the ideal nozzle calculation. Variance of jet spreading angle at different stagnation condition was measured as a function of mass flow rate. Periodic nature of the air jet distortion in water was observed and the frequency of the repetition was approximately 5-6 Hz for all cases tested. Three characteristic length scales were defined to characterize jet structure. $L_1$, maximum width of the plume when the periodic instability occurs, $L_2$, width of the jet where secondary reverse flow entrained jet flow and $L_3$, distance from the jet exit to the location where entrainment of the secondary reverse flow occurs. The ratio of $L_1$ and $L_2$ decreased with increasing stagnation pressure, i.e. mass flow rate. $L_3$ increased with increasing stagnation pressure. The temporal behavior of static pressure measurements also showed peak around frequency of 5, which corresponds the frequency obtained by visual measurements

Spectroscopic Comparison of Photo-oxidation of Outside and Inside of Hair by UVB Irradiation (자외선B 조사에 의한 모발 외부와 내부의 광산화에 관한 분광학적 비교)

  • Ha, Byung-Jo
    • Applied Chemistry for Engineering
    • /
    • v.31 no.2
    • /
    • pp.220-225
    • /
    • 2020
  • Hair is made of proteins containing various amino acids. Ultraviolet (UV) radiation is believed to be responsible for the most damaging effects of sunlight, and also plays an important role in hair aging. The purpose of this study was to investigate the changes in morphological and chemical structures after ultraviolet B (UVB) irradiation of human hair. The UVB-irradiated hair showed characteristic morphological and structural changes, compared to those of the normal hair. The result from a scanning electron microscope (SEM) equipped with an energy dispersive X-ray diffractometer (EDX) showed that the scale of UV-irradiated hair appeared to be rough and the amount of oxygen element was higher than that of the normal hair. Fluorescence and three dimensional (3D) topographical images were obtained by a confocal laser scanning microscope (CLSM). In 3D images, the green emission intensity of normal hair was much higher than that of fluorescing UVB-irradiated hair. The intensity of green emission reflects the intrinsic fluorescence of hair protein. Also, a fluorescent imaging method using fluorescamine reagent was used to identify the free amino groups resulting from a peptide bond breakage in UVB-irradiated hair. Strong blue fluorescence of UVB-irradiated hair, which indicates a very high level of amino groups, was observed by CLSM. Therefore, the fluorescamine as an extrinsic fluorescence could provide a useful tool to identify the peptide bond breakage in UVB-irradiated hair. Infrared image mapping was also employed to assess the cross-sections of normal and UVB-irradiated specimens to examine the oxidation of disulfide bonds. The degree of peak areas with strong absorbance for the disulfide mono-oxide was spread from the outside to the inside of hair. The spectroscopic techniques used alone, or in combination, launch new possibilities in the field of hair cosmetics.

Physicochemical properties of the materials used for the production of celadon maebyeong inlaid with cloud-and-crane designs and changes in their morphological properties by production stage (청자상감운학문매병 제작 재료의 물리화학적 특성 및 제작 단계별 형상학적 특성 변화)

  • Kim, Jihye;Ha, Jihyang;Han, Minsu
    • Conservation Science in Museum
    • /
    • v.25
    • /
    • pp.63-84
    • /
    • 2021
  • In order to investigate the diverse physicochemical changes that occurred in traditional Korean pottery during its production, including before and after firing, this study produced six replicas of a celadon maebyeong inlaid with cloud-and-crane designs, respectively corresponding to the process of shaping, carving, inlaying designs, first firing, glazing and second firing, respectively. It then conducted a scientific study of these six replicas and analyzed their images through high-resolution three-dimensional transmission imaging. The materials used for the replicas show different mineral phases and even colors depending on the components of each material. For example, black inlay with a high content of iron oxide (Fe2O3) shows dark colors and white inlay with a high alumina (Al2O3) content appears white. Physicochemical properties such as chromaticity and magnetic susceptibility and major components of the replicas were confirmed by the differences in the density in the computed tomography (CT) images. The characteristics of fired products such as fine structure, absorption ratio, apparent porosity, and other characteristics of the major mineral components were identified by the presence of pores and the formation of cracks inside the replicas in the image analysis.

Assessment of the Severity of Coronavirus Disease: Quantitative Computed Tomography Parameters versus Semiquantitative Visual Score

  • Xi Yin;Xiangde Min;Yan Nan;Zhaoyan Feng;Basen Li;Wei Cai;Xiaoqing Xi;Liang Wang
    • Korean Journal of Radiology
    • /
    • v.21 no.8
    • /
    • pp.998-1006
    • /
    • 2020
  • Objective: To compare the accuracies of quantitative computed tomography (CT) parameters and semiquantitative visual score in evaluating clinical classification of severity of coronavirus disease (COVID-19). Materials and Methods: We retrospectively enrolled 187 patients with COVID-19 treated at Tongji Hospital of Tongji Medical College from February 15, 2020, to February 29, 2020. Demographic data, imaging characteristics, and clinical data were collected, and based on the clinical classification of severity, patients were divided into groups 1 (mild) and 2 (severe/critical). A semiquantitative visual score was used to estimate the lesion extent. A three-dimensional slicer was used to precisely quantify the volume and CT value of the lung and lesions. Correlation coefficients of the quantitative CT parameters, semiquantitative visual score, and clinical classification were calculated using Spearman's correlation. A receiver operating characteristic curve was used to compare the accuracies of quantitative and semi-quantitative methods. Results: There were 59 patients in group 1 and 128 patients in group 2. The mean age and sex distribution of the two groups were not significantly different. The lesions were primarily located in the subpleural area. Compared to group 1, group 2 had larger values for all volume-dependent parameters (p < 0.001). The percentage of lesions had the strongest correlation with disease severity with a correlation coefficient of 0.495. In comparison, the correlation coefficient of semiquantitative score was 0.349. To classify the severity of COVID-19, area under the curve of the percentage of lesions was the highest (0.807; 95% confidence interval, 0.744-0.861: p < 0.001) and that of the quantitative CT parameters was significantly higher than that of the semiquantitative visual score (p = 0.001). Conclusion: The classification accuracy of quantitative CT parameters was significantly superior to that of semiquantitative visual score in terms of evaluating the severity of COVID-19.

Utility of Multidetector Computed Tomographic Angiography as an Alternative to Transesophageal Echocardiogram for Preoperative Transcatheter Mitral Valve Repair Planning

  • Craig Basman;Caroline Ong;Tikal Kansara;Zain Kassam;Caleb Wutawunashe;Jennifer Conroy;Arber Kodra;Biana Trost;Priti Mehla;Luigi Pirelli;Jacob Scheinerman;Varinder P Singh;Chad A Kliger
    • Journal of Cardiovascular Imaging
    • /
    • v.31 no.1
    • /
    • pp.18-23
    • /
    • 2023
  • BACKGROUND: Three-dimensional (3D) transesophageal echocardiogram (TEE) is the gold standard for the diagnosis of degenerative mitral regurgitation (dMR) and preoperative planning for transcatheter mitral valve repair (TMVr). TEE is an invasive modality requiring anesthesia and esophageal intubation. The severe acute respiratory syndrome coronavirus 2 pandemic has limited the number of elective invasive procedures. Multi-detector computed tomographic angiography (MDCT) provides high-resolution images and 3D reconstructions to assess complex mitral anatomy. We hypothesized that MDCT would reveal similar information to TEE relevant to TMVr, thus deferring the need for a preoperative TEE in certain situations like during a pandemic. METHODS: We retrospectively analyzed data on patients who underwent or were evaluated for TMVr for dMR with preoperative MDCT and TEE between 2017 and 2019. Two TEE and 2 MDCT readers, blinded to patient outcome, analyzed: leaflet pathology (flail, degenerative, mixed), leaflet location, mitral valve area (MVA), flail width/gap, anterior-posterior (AP) and commissural diameters, posterior leaflet length, leaflet thickness, presence of mitral valve cleft and degree of mitral annular calcification (MAC). RESULTS: A total of 22 (out of 87) patients had preoperative MDCT. MDCT correctly identified the leaflet pathology in 77% (17/22), flail leaflet in 91% (10/11), MAC degree in 91% (10/11) and the dysfunctional leaflet location in 95% (21/22) of patients. There were no differences in the measurements for MVA, flail width, commissural or AP diameter, posterior leaflet length, and leaflet thickness. MDCT overestimated the measurements of flail gap. CONCLUSIONS: For preoperative TMVr planning, MDCT provided similar measurements to TEE in our study.

CT-Based Radiomics Signature for Preoperative Prediction of Coagulative Necrosis in Clear Cell Renal Cell Carcinoma

  • Kai Xu;Lin Liu;Wenhui Li;Xiaoqing Sun;Tongxu Shen;Feng Pan;Yuqing Jiang;Yan Guo;Lei Ding;Mengchao Zhang
    • Korean Journal of Radiology
    • /
    • v.21 no.6
    • /
    • pp.670-683
    • /
    • 2020
  • Objective: The presence of coagulative necrosis (CN) in clear cell renal cell carcinoma (ccRCC) indicates a poor prognosis, while the absence of CN indicates a good prognosis. The purpose of this study was to build and validate a radiomics signature based on preoperative CT imaging data to estimate CN status in ccRCC. Materials and Methods: Altogether, 105 patients with pathologically confirmed ccRCC were retrospectively enrolled in this study and then divided into training (n = 72) and validation (n = 33) sets. Thereafter, 385 radiomics features were extracted from the three-dimensional volumes of interest of each tumor, and 10 traditional features were assessed by two experienced radiologists using triple-phase CT-enhanced images. A multivariate logistic regression algorithm was used to build the radiomics score and traditional predictors in the training set, and their performance was assessed and then tested in the validation set. The radiomics signature to distinguish CN status was then developed by incorporating the radiomics score and the selected traditional predictors. The receiver operating characteristic (ROC) curve was plotted to evaluate the predictive performance. Results: The area under the ROC curve (AUC) of the radiomics score, which consisted of 7 radiomics features, was 0.855 in the training set and 0.885 in the validation set. The AUC of the traditional predictor, which consisted of 2 traditional features, was 0.843 in the training set and 0.858 in the validation set. The radiomics signature showed the best performance with an AUC of 0.942 in the training set, which was then confirmed with an AUC of 0.969 in the validation set. Conclusion: The CT-based radiomics signature that incorporated radiomics and traditional features has the potential to be used as a non-invasive tool for preoperative prediction of CN in ccRCC.