• Title/Summary/Keyword: Images of Seoul

Search Result 2,118, Processing Time 0.028 seconds

Performance Evaluation of Radiochromic Films and Dosimetry CheckTM for Patient-specific QA in Helical Tomotherapy (나선형 토모테라피 방사선치료의 환자별 품질관리를 위한 라디오크로믹 필름 및 Dosimetry CheckTM의 성능평가)

  • Park, Su Yeon;Chae, Moon Ki;Lim, Jun Teak;Kwon, Dong Yeol;Kim, Hak Joon;Chung, Eun Ah;Kim, Jong Sik
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.32
    • /
    • pp.93-109
    • /
    • 2020
  • Purpose: The radiochromic film (Gafchromic EBT3, Ashland Advanced Materials, USA) and 3-dimensional analysis system dosimetry checkTM (DC, MathResolutions, USA) were evaluated for patient-specific quality assurance (QA) of helical tomotherapy. Materials and Methods: Depending on the tumors' positions, three types of targets, which are the abdominal tumor (130.6㎤), retroperitoneal tumor (849.0㎤), and the whole abdominal metastasis tumor (3131.0㎤) applied to the humanoid phantom (Anderson Rando Phantom, USA). We established a total of 12 comparative treatment plans by the four geometric conditions of the beam irradiation, which are the different field widths (FW) of 2.5-cm, 5.0-cm, and pitches of 0.287, 0.43. Ionization measurements (1D) with EBT3 by inserting the cheese phantom (2D) were compared to DC measurements of the 3D dose reconstruction on CT images from beam fluence log information. For the clinical feasibility evaluation of the DC, dose reconstruction has been performed using the same cheese phantom with the EBT3 method. Recalculated dose distributions revealed the dose error information during the actual irradiation on the same CT images quantitatively compared to the treatment plan. The Thread effect, which might appear in the Helical Tomotherapy, was analyzed by ripple amplitude (%). We also performed gamma index analysis (DD: 3mm/ DTA: 3%, pass threshold limit: 95%) for pattern check of the dose distribution. Results: Ripple amplitude measurement resulted in the highest average of 23.1% in the peritoneum tumor. In the radiochromic film analysis, the absolute dose was on average 0.9±0.4%, and gamma index analysis was on average 96.4±2.2% (Passing rate: >95%), which could be limited to the large target sizes such as the whole abdominal metastasis tumor. In the DC analysis with the humanoid phantom for FW of 5.0-cm, the three regions' average was 91.8±6.4% in the 2D and 3D plan. The three planes (axial, coronal, and sagittal) and dose profile could be analyzed with the entire peritoneum tumor and the whole abdominal metastasis target, with planned dose distributions. The dose errors based on the dose-volume histogram in the DC evaluations increased depending on FW and pitch. Conclusion: The DC method could implement a dose error analysis on the 3D patient image data by the measured beam fluence log information only without any dosimetry tools for patient-specific quality assurance. Also, there may be no limit to apply for the tumor location and size; therefore, the DC could be useful in patient-specific QAl during the treatment of Helical Tomotherapy of large and irregular tumors.

Evaluation of Image Quality Based on Time of Flight in PET/CT (PET/CT에서 재구성 프로그램의 성능 평가)

  • Lim, Jung Jin;Yoon, Seok Hwan;Kim, Jong Pil;Nam Koong, Sik;Shin, Seong Hwa;Yoon, Sang Hyeok;Kim, Yeong Seok;Lee, Hyeong Jin;Lee, Hong Jae;Kim, Jin Eui;Woo, Jae Ryong
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.16 no.2
    • /
    • pp.110-114
    • /
    • 2012
  • Purpose : PET/CT is widely used for early checking up of cancer and following up of pre and post operation. Image reconstruction method is advanced with mechanical function. We want to evaluate image quality of each reconstruction program based on time of flight (TOF). Materials and Methods : After acquiring phantom images during 2 minutes with Gemini TF (Philips, USA), Biograph mCT (Siemens, USA) and Discovery 690 (GE, USA), we reconstructed image applied to Astonish TF (Philips, USA), ultraHD PET (Siemens, USA), Sharp IR (GE, USA) and not applied. inside of Flangeless Esser PET phantom (Data Spectrum corp., USA) was filled with $^{18}F$-FDG 1.11 kBq/ml (30 Ci/ml) and 4 hot inserts (8. 12. 16. 25 mm) were filled with 8.88 kBq/ml (240 ${\mu}Ci/ml$) the ratio of background activity and hot inserts activity was 1 : 8. Inside of triple line phantom (Data Spectrum corp., USA) was filled with $^{18}F$-FDG 37 MBq/ml (1 mCi). Three of lines were filled with 0.37 MBq (100 ${\mu}Ci$). Contrast ratio and background variability were acquired from reconstruction image used Flangeless Esser PET phantom and resolution was acquired from reconstruction image used triple line phantom. Results : The contrast ratio of image which was not applied to Astonish TF was 8.69, 12.28, 19.31, 25.80% in phantom lid of which size was 8, 12, 16, 25 mm and it which was applied to Astonish TF was 6.24, 13.24, 19.55, 27.60%. It which was not applied to ultraHD PET was 4.94, 12.68, 22.09, 30.14%, it which was applied to ultraHD PET was 4.76, 13.23, 23.72, 31.65%. It which was not applied to SharpIR was 13.18, 17.44, 28.76, 34.67%, it which was applied to SharpIR was 13.15, 18.32, 30.33, 35.73%. The background variability of image which was not applied to Astonish TF was 5.51, 5.42, 7.13, 6.28%. it which was applied to Astonish TF was 7.81, 7.94, 6.40 6.28%. It which was not applied to ultraHD PET was 6.46, 6.63, 5.33, 5.21%, it which was applied to ultraHD PET was 6.08, 6.08, 4.45, 4.58%. It which was not applied to SharpIR was 5.93, 4.82, 4.45, 5.09%, it which was applied to SharpIR was 4.80, 3.92, 3.63, 4.50%. The resolution of phantom line of which location was upper, center, right, which was not applied to Astonish TF was 10.77, 11.54, 9.34 mm it which was applied to Astonish TF was 9.54, 8.90, 8.88 mm. It which was not applied to ultraHD PET was 7.84, 6.95, 8.32 mm, it which was applied to ultraHD PET was 7.51, 6.66, 8.27 mm. It which was not applied to SharpIR was 9.35, 8.69, 8.99, it which was applied to SharpIR was 9.88, 9.18, 9.00 mm. Conclusion : Image quality was advanced generally while reconstruction program which is based on time of flight was used. Futhermore difference of result compared each manufacture reconstruction program showed up, however this is caused by specification of instrument of each manufacture and difference of reconstruction algorithm. Therefore we need further examination to find out appropriate reconstruction condition while using reconstruction program used for advance of image quality.

  • PDF

$^{99m}Tc-DTPA$ Galactosyl Human Serum Albumin Scintigyaphy in Mushiroom Poisoning Patient : Comparison with Liver Ultrasonography (버섯 중독 환자에서의 $^{99m}Tc-galactosyl$ human serum albumin (GSA) scintigraphy 소견 : 간초음파 소견과의 비교)

  • Jeong, Shin-Young;Lee, Jea-Tae;Bae, Jin-Ho;Chun, Kyung-Ah;Ahn, Byeong-Cheol;Kang, Young-Mo;Jeong, Jae-Min;Lee, Kyu-Bo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.37 no.4
    • /
    • pp.254-259
    • /
    • 2003
  • $^{99m}Tc-galactosyl$ human serum albumin (Tc-GSA) is a radiopharmaceutical that binds to asialoglycoprotein receptors, which are specifically present in the hepatocyte membrane. Because these receptors are decreased in hepatic parenchymal damage, the degree of Tc-GSA accumulation in the liver correlates with findings of liver function test. Hepatic images were performed with Tc-GSA in patients with acute hepatic dysfunction by Amantia Subjunquillea poisoning, and compared with these of liver ultrasonography (USG). Tc-GSA (185 MBq, 3 mg of GSA) was injected intravenously, and dynamic images were recorded for 30 minutes. Time-activity curves for the heart and liver were generated from regions of interest for the whole liver and precordium. Degree of hepatic uptake and clearance rate of Tc-GSA were generated by visual interpretation and semiquantitative analysis parameters (receptor index : LHL15 and index of blood clearance : HH15). Visual assessment of GSA scintigraphy revealed mildly decreased liver uptake in all of subjects. The mean LHL15 and HH15 were 0.886 and 0.621, graded as mild dysfunction in 2, and mild to moderate dysfunction in 1 subject. In contrast, liver USG showed no remarkable changes of hepatic parenchyme. Tc-GSA scintigraphy was considered as a useful imaging modality in the assessment of the hepatic dysfunction.

The Usability Evaluation of the Usefulness of Bismuth Shields in PET/CT Examination (PET/CT 검사에서 비스무스(bismuth) 차폐체의 적용에 따른 유용성 평가)

  • Park, Hoon-Hee;Lee, Juyoung;Kim, Ji-Hyeon;Nam, Kun-Sik;Lyu, Kwang-Yeul;Lee, Tae Soo
    • Journal of radiological science and technology
    • /
    • v.37 no.1
    • /
    • pp.49-56
    • /
    • 2014
  • Recently with CT developed, various studies for reduction of exposure dose is underway. Study of bismuth shields in these studies is actively underway, and has already been applied in the clinical. However, the application of the PET/CT examination was not activated. Therefore, through this study, depending on the application of bismuth shields in the PET/CT examination, we identify the quality of the image and the impact on the Standard Uptake Value (SUV). In this study, to apply to the shielding of the breast, by using the bismuth shields that contains 0.06 mm Pb ingredients, was applied to the PET/CT GEMINI TF 64 (Philips Healthcare, Cleveland, USA). Phantom experiments using the NEMA IEC Body Phantom, images were acquired according to the presence or absence of bismuth shields apply. Also, When applying, images were obtained by varying the spacing 0, 1, 2 cm each image set to the interest range in the depth of the phantom by using EBW-NM ver.1.0. When image of the PET Emission acquires, the SUV was in increased depending on the use of bismuth shields, difference in the depth to the surface from deep in the phantom increasingly SUV increased (P<0.005). Also, when using shields, as the more gab decreased, SUV is more increased (P<0.005). Through this study, PET/CT examination by using of bismuth shields which is used as purpose of reduction dose. When using shields, the difference of SUV resulting from the application of bismuth shields exist and that difference when gab is decrease and surface is wider. Therefore, setting spacing of shield should be considered, if considering the reduction of the variation of SUV and image quality, disease of deep organs should be a priority rather than superficial organ disease. Use of bismuth shielding factor considering the standard clinical examination, decrease unnecessary exposure can be expected to be considered.

A Functional MRI Study on the Brain Activation Associated with Mental Calculation (기능적 자기공명영상을 이용한 수리연산의 대뇌 활성화에 관한 연구)

  • Choi Dae Seob;Na Dong Gyu;Kim Sam Soo;Cho Jae Min;Park Eui Dong;Chung Sung Hoon;Ryoo Jae Wook
    • Investigative Magnetic Resonance Imaging
    • /
    • v.9 no.1
    • /
    • pp.16-23
    • /
    • 2005
  • Purpose : In order to investigate the functional brain anatomy associated with mental calculation, functional magnetic resonance imaging was performed. Materials and Methods : In six normal right handed subjects, functional MR images were obtained using a 1.57 MR scanner and the EPI BOLD technique. The study included experiment I and experiment II. Each experiment consisted of five resting and four activation periods with each period of 30 seconds. During the activation period of both experiment I and II, calculation equations[an example: $(4+5)\times8=72$] were presented and the subjects were instructed to decide true or false of them. During the resting period of experiment I, the subjects were instructed to visually fixate on a crosshair. During the resting period of experiment II, two diagrams (an example: $(\bullet,\;\blacksquare)$)were presented and the subjects were instructed to decide they are same or not. For the post-processing of images, the SPM program was used, with the threshold of significance set at p<0.00001. The activated areas during the tasks were assessed. Results : In experiment 1, the inferior frontal gyrus, prefrontal cortex, promoter area, supplementary motor area, and intraparietal sulcus including superior parietal cortex were activated bilaterally. Although these areas were also activated in experiment II, the activated signals in the right frontal and parietal lobes were lessened. Conclusion : The left inferior frontal gyrus and prefrontal cortex and bilateral intraparietal sulci were activated during mental calculation. The right frontal and parietal lobes might be related to attention and decision making.

  • PDF

THE PRELIMINARY STUDY OF THE QUANTITATIVE MORPHOLOGIC ANALYSIS USING MRI OF THE LATERAL VENTRICLE IN EARLY-ONSET PSYCHOTIC DISORDER (조기 발병한 정신증적 장애에서 자기공명영상을 이용한 측뇌실에 대한 구조적인 예비연구)

  • Lee, Youn-Hee;Kang, Min-Hee;Kim, Chul-Eung;Bae, Jae-Nam;Hong, Kang-E;Lee, Jeong-Seop
    • Journal of the Korean Academy of Child and Adolescent Psychiatry
    • /
    • v.12 no.2
    • /
    • pp.256-262
    • /
    • 2001
  • Objective:The enlargement of the lateral ventricle is well established finding in adult-onset schizophrenia, but in the patients with early-onset psychotic disorder(EOPD) is still controversal. To identify structural abnormalities of the lateral ventricle in patients with EOPD and difference of the brain developmental course in EOPD group, planimetrical assessment of the lateral ventricle was conducted by means of retrospective quantitative neuroimaging. Methods:The brain MR images of 14 patients with EOPD(mean age $14.0{\pm}2.1$ years) who met the DSM-III-R diagnostic criteria for schizophrenia and bipolar disorder and 24 control subjects with simple headache(mean age $10.0{\pm}2.1$ years) were collected. Single best view for the lateral ventricle, one axial slice was selected for analysis. MR images were redigitalized with flatbed scanner and data were analyzed with NIH IMAGE software. Results:In the patients with EOPD, there were significant correlations between aging and lateral ventricular sizes and between aging and ventricular brain ratio(VBR). The statistical significance of normal asymmetry of the lateral ventricle was not observed for the EOPD group. The EOPD group had larger lateral ventricular sizes and VBR than control group, but these results were not statistically significant. Conclusion:These findings suggest that the brain abnormalities in patients with EOPD progress from the earlier course of the disorders and the course of brain development in EOPD group is different from control group.

  • PDF

A Study on Precision of 3D Spatial Model of a Highly Dense Urban Area based on Drone Images (드론영상 기반 고밀 도심지의 3차원 공간모형의 정밀도에 관한 연구)

  • Choi, Yeon Woo;Yoon, Hye Won;Choo, Mi Jin;Yoon, Dong Keun
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.40 no.2
    • /
    • pp.69-77
    • /
    • 2022
  • The 3D spatial model is an analysis framework for solving urban problems and is used in various fields such as urban planning, environment, land and housing management, and disaster simulation. The utilization of drones that can capture 3D images in a short time at a low cost is increasing for the construction of 3D spatial model. In terms of building a virtual city and utilizing simulation modules, high location accuracy of aerial survey and precision of 3D spatial model function as important factors, so a method to increase the accuracy has been proposed. This study analyzed location accuracy of aerial survey and precision of 3D spatial model by each condition of aerial survey for urban areas where buildings are densely located. We selected Daerim 2-dong, Yeongdeungpo-gu, Seoul as a target area and applied shooting angle, shooting altitude, and overlap rate as conditions for the aerial survey. In this study, we calculated the location accuracy of aerial survey by analyzing the difference between an actual survey value of CPs and a predicted value of 3D spatial Model. Also, We calculated the precision of 3D spatial Model by analyzing the difference between the position of Point cloud and the 3D spatial Model (3D Mesh). As a result of this study, the location accuracy tended to be high at a relatively high rate of overlap, but the higher the rate of overlap, the lower the precision of 3D spatial model and the higher the shooting angle, the higher precision. Also, there was no significant relationship with precision. In terms of baseline-height ratio, the precision tended to be improved as the baseline-height ratio increased.

The Usability Evaluation According to the Application of Bismuth Shields in PET/CT Examination (PET/CT 검사에서 비스무스(bismuth) 차폐체의 적용에 따른 유용성 평가)

  • Nam-Kung, Sik;Kim, Ji Hyeon;Lee, Ju young;Park, Hoon Hee
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.17 no.1
    • /
    • pp.36-42
    • /
    • 2013
  • Purpose: Recently with CT developed, various studies for reduction of exposure dose is underway. Study of bismuth shields in these studies is actively underway, and has already been applied in the clinical. However, the application of the PET/CT examination was not activated. Therefore, through this study, depending on the application of bismuth shields in the PET/CT examination, we want to identify the quality of the image and the impact on the SUV. Materials and Methods: In this study, to apply to the shielding of the breast, by using the bismuth shields that contains 0.06 mmPb ingredients, was applied to the PET/CT GEMINI TF 64 (Philips Healthcare, Cleveland, USA). Phantom experiments using the NEMA IEC Body Phantom, images were acquired according to the presence or absence of bismuth shields apply. Also, When applying, images were obtained by varying the spacing 0, 1, 2 cm each image set to the interest range in the depth of the phantom by using EBW-NM ver.1.0. Results: When image of the PET Emission acquires, the SUV was in increased depending on the use of bismuth shields, difference in the depth to the surface from deep in the phantom increasingly SUV increased (P<0.005). Also, when using shields, as the more gab decreased, SUV is more increased (P<0.005). Conclusion: Through this study, PET/CT examination by using of bismuth shields which is used as purpose of reduction dose be considered. When using shields, the difference of SUV resulting from the application of bismuth shields exist and that difference is more decreased as gab of shields and surface is wider. Therefore, setting spacing of shield should be considered, if considering the reduction of the variation of SUV and image quality, disease of deep or other organs should be a priority rather than superficial disease. Through this study, when applying identified to clinical examination, the reduction of unnecessary exposure is considered.

  • PDF

Development of tracer concentration analysis method using drone-based spatio-temporal hyperspectral image and RGB image (드론기반 시공간 초분광영상 및 RGB영상을 활용한 추적자 농도분석 기법 개발)

  • Gwon, Yeonghwa;Kim, Dongsu;You, Hojun;Han, Eunjin;Kwon, Siyoon;Kim, Youngdo
    • Journal of Korea Water Resources Association
    • /
    • v.55 no.8
    • /
    • pp.623-634
    • /
    • 2022
  • Due to river maintenance projects such as the creation of hydrophilic areas around rivers and the Four Rivers Project, the flow characteristics of rivers are continuously changing, and the risk of water quality accidents due to the inflow of various pollutants is increasing. In the event of a water quality accident, it is necessary to minimize the effect on the downstream side by predicting the concentration and arrival time of pollutants in consideration of the flow characteristics of the river. In order to track the behavior of these pollutants, it is necessary to calculate the diffusion coefficient and dispersion coefficient for each section of the river. Among them, the dispersion coefficient is used to analyze the diffusion range of soluble pollutants. Existing experimental research cases for tracking the behavior of pollutants require a lot of manpower and cost, and it is difficult to obtain spatially high-resolution data due to limited equipment operation. Recently, research on tracking contaminants using RGB drones has been conducted, but RGB images also have a limitation in that spectral information is limitedly collected. In this study, to supplement the limitations of existing studies, a hyperspectral sensor was mounted on a remote sensing platform using a drone to collect temporally and spatially higher-resolution data than conventional contact measurement. Using the collected spatio-temporal hyperspectral images, the tracer concentration was calculated and the transverse dispersion coefficient was derived. It is expected that by overcoming the limitations of the drone platform through future research and upgrading the dispersion coefficient calculation technology, it will be possible to detect various pollutants leaking into the water system, and to detect changes in various water quality items and river factors.

Objects and Landscape Characteristics of Japanese Apricot(Prunus mume) Appreciation through the Poem Titles (매화시제(梅花詩題)를 통해 본 매화 완상(玩賞)의 대상과 경관 특성)

  • So, Hyun-Su;Lim, Eui-Je
    • Journal of the Korean Institute of Traditional Landscape Architecture
    • /
    • v.31 no.4
    • /
    • pp.84-94
    • /
    • 2013
  • This study scrutinizes the titles of serial poems on Japanese Apricot, which have lucid characters on season and time changes, having been appreciated and recited by the scholars in the Choseon Dynasty era and analyses the records of Zhang zi(1153~1235), a writer in Song(宋) Dynasty in China, having presented the objects harmonizing perfectly with Japanese Apricot. The results of this study categorizes the objects of Japanese Apricot appreciation and establishes the landscape characteristics on Japanese Apricot appreciation affiliated with as follows. First, the objects of Japanese Apricot appreciation are categorized into 'form of blossoms', 'natural feature(景物)', 'place of tree planting', 'the picturesque scene(景色)' and 'behavior'. Second, the scholars regarded the single trees whose branches are grotesque as the objects of appreciation and enjoyed them. They preferred white and single petal Japanese Apricot and admired red Japanese Apricot which has Taoism images. Third, they admired pines and camelias which represent fidelity and strength and valued Japanese Apricot with cranes which remind themselves of solitary scholars. Fourth, they appreciated the images of Japanese Apricot reflected on the water, and the poetically inspiring atmosphere where the trees are planted by the window. Fifth, the moon and snow were crucial weather conditions for appreciating. cold weather and time from night to dawn were ideally suited for enjoying. Sixth, they enjoyed blossoms in various fashions like bottling(甁梅), potting(盆梅), green-housing(龕梅), searching(龕梅) and black-and-white painting(墨梅) with a view to seeing blossoms earlier than the usual flowering time. Moreover, they used paper drapes, bead curtains, mirrors and ice lamps for active appreciation. They also listened to the sound of Piri(wind) and Geomungo(string), played go and drew tea with noble and elegant beauties when they enjoyed Japanese Apricot. The scholars influenced by the neo-Confucianism, which contemplates the objects, attached the specific sentiments like memories, grieves, dreams and farewells to Japanese Apricot and appreciated them. As stated above the scholars enjoyed the landscape including the picturesque scene like climate-weather, time-season and human behaviors not to mention the physical beauty of Japanese Apricot themselves and objects in company with Japanese Apricot including animals and plants.