• Title/Summary/Keyword: Image quality indicator

Search Result 41, Processing Time 0.029 seconds

Comparison of Non-Destructive Testing Images using $^{192}Ir$ and $^{75}Se$ with Computed Radiography System (Computed Radiography 시스템에 $^{192}Ir$$^{75}Se$ 동위원소를 적용하여 촬영한 비파괴검사 영상 비교)

  • Kang, Sang-Mook;Chol, Chang-Il;Lee, Seung-Kyu;Park, Sang-Ki;Kim, Yong-Kyun
    • Journal of Radiation Protection and Research
    • /
    • v.35 no.1
    • /
    • pp.26-33
    • /
    • 2010
  • A computed Radiography (CR) system by use of reusable Image Plate (IP) offers a convenient and reliable way to replace a conventional film-screen system for NDT (non-destructive testing) field. The quality of a radiography to detect a defect of welded objects depends on the procedure embracing several factors such as measurement conditions, image plate type/class, radiation energy, radiation type, and source to image plate distance. Also, the ability of images to detect a flaw reduces with increasing object thickness. In the study, the properties of gamma ray source were summarized for NDT field and inspection images of CR image system manufactured by FUJI were acquired using $^{75}Se$ and $^{192}Ir$ with welded objects. We analyzed the gray scale of hole defect image by using XCAP image processing program and calculated the image contrast and SNR in definition. Also the sesitivities of image quality indicator(IQI) were calculated for hot and cooling tube image of $^{75}Se$ and $^{192}Ir$.

Indicator Elimination for Locally Adaptive Scheme Using Data Hiding Technique

  • Chang, Hon-Hang;Chou, Yung-Chen;Shih, Timothy K.
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.8 no.12
    • /
    • pp.4624-4642
    • /
    • 2014
  • Image compression is a popular research issue that focuses on the problems of reducing the size of multimedia files. Vector Quantization (VQ) is a well-known lossy compression method which can significantly reduce the size of a digital image while maintaining acceptable visual quality. A locally adaptive scheme (LAS) was proposed to improve the compression rate of VQ in 1997. However, a LAS needs extra indicators to indicate the sources, consequently the compression rate of LAS will be affected. In this paper, we propose a novel method to eliminate the LAS indicators and so improve the compression rate. The proposed method uses the concept of data hiding to conceal the indicators, thus further improving the compression rate of LAS. From experimental results, it is clearly demonstrated that the proposed method can actually eliminate the extra indicators while successfully improving the compression rate of the LAS.

A Case Study of Application of Exposure Index in Computed Radiography by Using Human Chest Phantom (인체 흉부 모형 팬텀을 이용한 컴퓨터방사선영상에서 노출지수의 적용 사례 연구)

  • Jeong, Hoi-Woun;Min, Jung-Whan
    • Journal of radiological science and technology
    • /
    • v.41 no.6
    • /
    • pp.533-538
    • /
    • 2018
  • As the use of digital radiographic system has been expanded, there are some concerns an increase about in patient of radiation dose. Therefore, International Electro-technical Commission (IEC) has been proposed a standard foe exposure index (EI). In this study, the EI was measured on human chest model using computed radiography (CR). Radiation quality used RQA5 of IEC62494-1. After acquiring the chest anterior posterior image (Chest AP) by using the phantom, the EI was obtained by applying the system response. In this study, we have analyzed the images with the detector size (Full filed ROI) and the optimized image (Fit filed ROI). The EI increased proportionally with radiation dose increase. Due to the discrete increase in pixel value, the EI showed an exponential increase. The discrete increase in noise equivalent quanta (NEQ) resulted in a discrete increase in the EI. The EI of the two images used in this study increased with increasing NEQ but showed different increments. For the measurement of the EI, IEC standards must be followed. The EI should be used as an index to evaluate the image quality for quality control of X-ray image rather than as an indicator of exposure dose. When calculating the EI, the system response should be applied depending on whether or not the grid is used. The size of the field should be obtained by including only the necessary parts.

Implementation of Wavelet Transform based Image Fusion and JPEG2000 using MAD Order Statistics for Multi-Image (MAD 순서통계량을 이용한 웨이블렛 변환기반 다중영상의 영상융합 및 JPEG2000 보드 구현)

  • Lee, Cheeol
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.17 no.11
    • /
    • pp.2636-2644
    • /
    • 2013
  • This paper is proposed a wavelet-based the order statistics MAD(Median Absolute Deviation) method of image fusion of Multi-image contaminated with visible image and infrared image. also The method of compared and defined the threshold the wavelet coefficients using MAD of the wavelet coefficients of the detail subbands was proposed to effectively fusion which of selected the high quality image of the two images. The existed fusion rule may be possible to get the distorted fusion image especially by the distortion in the relation between the pixel and indicator of two images in the existed fusion rules. In order to complement the disadvantage, the threshold of the proposed method sets up the image statistic and excludes the distortion. The hardware design is used FPGA of Xilinx and DSP system for the image fusion and compressed encoding of the proposed algorithm. Therefore the proposed method is totally verified by comparing with the several other multi-image and the proposed image fusion.

Estimating the Spatial Distribution of Satellite Image Classification Error Using Index of Spatial Distribution (공간분포지표를 이용한 위성영상 분류오차의 공간적 분포 평가)

  • 이병길;김용일;어양담
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.17 no.2
    • /
    • pp.129-136
    • /
    • 1999
  • The quality of image classification results is not always uniform over entire image. Thus, this study proposes the concept of ISDd (Index of Spatial Distribution by distance) and ISDs (ISD by scatteredness) for the evaluation of unevenness of result quality, and spatial distribution of satellite image classification errors. The ISDd is indexed mean distance of misclassified pixels and the ISDs is statistical indicator of scatteredness of misclassified pixels. In this study, the ISDd and the ISDs are calculated and evaluated for some satellite images, then misclassified area is extracted and the reasons of misclassification are examined. As the result of this study, using both the ISDd and the ISDs, the basis of decision on adoption/rejection of classification results is offered at sub-image level by evaluation of the local aggregation of misclassified pixels. Using Index of Spatial Distribution. as well as overall classification accuracy, users can understand the spatial distribution of misclassified pixels, and can have the additional criterion of the judgement on suitability and reliability of classification results.

  • PDF

Selection of mAs with Using Table Strap in Computed Tomography Scan (전산화단층촬영 시 환자 고정 밴드를 이용한 선량의 선택)

  • Lee, Young-Hyen;An, Hyeong-Theck
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.13 no.2
    • /
    • pp.63-69
    • /
    • 2011
  • Table strapis patient fixture for securing the patient movements and falls. if it designed to measure the abdominal circumference and used as an indicator of dose selection at CT scan. it will prevent the overexposure of dose without degradation of image quality and efficiently manage dose of each type of body to technician to deal with CT. First, in order to compare the dose used in CT image and qualitative characteristics. reference image is obtained by examining the abdominal phantom in same conditions with the hospital 120 kVp, 200 mAs, D-Dom (Dynamic Dose Of Modulation). SNR, PSNR, RMSE, MAE, CTDIvol of CT images are compared with reference image. for comparing with reference image, the image that Umbilicus level image of Abdomen CT is stored in the PACS were used. For comparison, the top 12 o'clock portion of the air drawn from the same ROI was measured. CTDIvol, mAs, etc. In order to analyze the characteristics of the image, by measuring the length of the umbilicus circumference, pattern of the dose was analyzed. by using the analyzed perimeter and dose information, To be identified visually, fixed band that scale marked were produced. Use them, If the length of circumference of less than 60 cm 100 mAs, Case of 61~80 cm 120 mAs, Case of 80~100 cm 150 mAs, more than 100 cm 200 mAs, dose selection based on the perimeter, the image was applied. by compare analyzed with the Reference Image, image quality was assessed. by compare with existing tests that equally 200 mAs applied, How much was confirmed that the dose reduction. 1. Depending on the Abdominal circumference, the average PSNR(dB) of the image that differently dose applied was 45.794. 2. Comparing with existing test. the dose of scan that adjusted the mAs depending on the circumference was decreased about 40%. SNR and PSNR of the image that obtained by adjusting the standard mAs based on dose modulation were not much different. Therefore, By choosing a low mAs. dose reduction can be obtained. and the dose selection method that measured Abdominal circumference using a fixed band can protect the overexposure and uniformly apply dose of each type of body to technician to deal with CT.

  • PDF

A Quantitative Study of the Quality of Deconvolved Wide-field Microscopy Images as Function of Empirical Three-dimensional Point Spread Functions

  • Adur, Javier;Vicente, Nathalie;Diaz-Zamboni, Javier;Izaguirre, Maria Fernanda;Casco, Victor Hugo
    • Journal of the Optical Society of Korea
    • /
    • v.15 no.3
    • /
    • pp.252-263
    • /
    • 2011
  • In this work, for the first time, the quality of restoration in wide-field microscopy images after deconvolution was analyzed as a function of different Point Spread Functions using one deconvolution method, on a specimen of known size and on a biological specimen. The empirical Point Spread Function determination can significantly depend on the numerical aperture, refractive index of the embedding medium, refractive index of the immersion oil and cover slip thickness. The influence of all of these factors is shown in the same article and using the same microscope. We have found that the best deconvolution results are obtained when the empirical PSF utilized is obtained under the same conditions as the specimen. We also demonstrated that it is very important to quantitatively check the process' outcome using several quality indicators: Full-Width at Half-Maximum, Contrast-to-Noise Ratio, Signal-to-Noise Ratio and a Tenengrad-based function. We detected a significant improvement when using an indicator to measure the focus of the whole stack. Therefore, to qualitatively determinate the best deconvolved image between different conditions, one approach that we are pursuing is to use Tenengrad-based function indicators in images obtained using a wide-field microscope.

Development of Evaluation Indicators for Industrialization of Local Cuisine (향토음식의 산업화가치 평가를 위한 지표 개발 연구)

  • Choe, Jeong-Sook;Park, Han-Sik;Park, Seung-Hyun;Lee, Jin-Young;Kang, Min-Sook
    • Journal of the Korean Society of Food Culture
    • /
    • v.27 no.3
    • /
    • pp.233-239
    • /
    • 2012
  • The purpose of this study was to develop an evaluation indicator for the industrialization of local cuisine. We conducted a literature study, interviews with experts, and a Delphi survey. The resulting evaluation indicator was divided into four groups and nine sub-groups. The four groups were locality, taste and functionality, industrial base, and business value. The nine sub-groups were traditionality, regionality, eating quality, nutrition and functionality, condition of development, technological level, rights and policy, marketability, and ripple effects. Also 22 items were created as indicators for evaluating classes ; historicity, sustainability, rarity, awareness of local resident, the number of similar restaurant, appearance, taste, nutritional balance, health functionality, availability of raw materials, suitability of environmental exchange of market, standardization of recipe, simplification of recipe, storability, intellectual property rights, government's policy, appropriacy of price, popularization, possibility of franchise, globalization, improvement of local image, vitalization of local economy. The four most important classes corresponded to one of the four groups. These classes were sustainability, taste, state (local autonomy) policy, vitalization of local economy. The implications of this study are that the possibility of industrializing the local cuisine of each region can be evaluated and applied. Moreover, these indicators could promote the discovery of local cuisines, support planning for the commercialization of local cuisine.

A Delphi Approach to the Development of an Integrated Performance Measurement and Management Model for a Car Assembler

  • Shawyun, Teay
    • Industrial Engineering and Management Systems
    • /
    • v.7 no.3
    • /
    • pp.214-227
    • /
    • 2008
  • Today's dynamic competitiveness requires an organization to improve its performance measurement and management. Quality Management Systems (QMS) abound, the main ones being: ISO series, Malcolm Baldridge National Quality Award (MBNQA), European Forum for Quality Management (EFQM), Six Sigma Business Scorecard and the Balanced Scorecard. Based on the literature, the IPMMM (Integrated Performance Measurement and Management Model) identified 7 key synthesized factors: leadership, strategy management and policy, customer and market, learning and growth, partnership and resources, internal processes and business results that are employed to investigate the key performance indicators of a car assembler using the Delphi methodology. In the 2 rounds of Delphi panels consisting of 20 senior management personnel, the $1^{st}$ round of 198 indicators in the IPMMM yielded 90 indicators. The $2^{nd}$ round yielded 43 performance indicators with 18 rated as critical based on the % assigned in the $1^{st}$ and $2^{nd}$ priority rating of "very important factor" and "key performance indicator" that must be ranked high on both of the priorities. The very critical indicators appeared to be: defect percentage and first time capability (tie in $1^{st}$ place) and revenue, goal setting, customer satisfaction index, on-time delivery, brand image, return on investment, Claim Occurrence Ratio, and debt being ranked from $3^{rd}$ to $10^{th}$. It can be surmised that an organization can identify and develop an appropriate set of performance indicators through the Delphi methodology and implement and manage them based on the Balanced Scorecard.

Correlation between Head Movement Data and Virtual Reality Content Immersion (헤드 무브먼트 데이터와 가상현실 콘텐츠 몰입도 상관관계)

  • Kim, Jungho;Yoo, Taekyung
    • Journal of Broadcast Engineering
    • /
    • v.26 no.5
    • /
    • pp.500-507
    • /
    • 2021
  • The virtual reality industry has an opportunity to take another leap forward with the surge in demand for non-face-to-face content and interest in the metaverse after Covid-19. Therefore, in order to popularize virtual reality content along with this trend, high-quality content production and storytelling research suitable for the characteristics of virtual reality should be continuously conducted. In order for content to which virtual reality characteristics are applied to be effectively produced through user feedback, a quantitative index that can evaluate the content is needed. In this study, the process of viewing virtual reality contents was analyzed and head movement was set as a quantitative indicator. Afterwards, the experimenter watched five animations and analyzed the correlation between recorded head movement information and immersion. As a result of the analysis, high immersion was shown when the head movement speed was relatively slow, and it was found that the head movement speed can be used significantly as an index indicating the degree of content immersion. The result derived in this way can be used as a quantitative indicator that can verify the validity of the storytelling method applied after the prototype is produced when the creator creates virtual reality content. This method can improve the quality of content by quickly identifying the problems of the proposed storytelling method and suggesting a better method. This study aims to contribute to the production of high-quality virtual reality content and the popularization of virtual reality content as a basic research to analyze immersion based on the quantitative indicator of head movement speed.