A Quantitative Study of the Quality of Deconvolved Wide-field Microscopy Images as Function of Empirical Three-dimensional Point Spread Functions |
Adur, Javier
(Microscopy Laboratory Applied to Molecular and Cellular Studies, School of Engineering, National University of Entre Rios)
Vicente, Nathalie (Microscopy Laboratory Applied to Molecular and Cellular Studies, School of Engineering, National University of Entre Rios) Diaz-Zamboni, Javier (Microscopy Laboratory Applied to Molecular and Cellular Studies, School of Engineering, National University of Entre Rios) Izaguirre, Maria Fernanda (Microscopy Laboratory Applied to Molecular and Cellular Studies, School of Engineering, National University of Entre Rios) Casco, Victor Hugo (Microscopy Laboratory Applied to Molecular and Cellular Studies, School of Engineering, National University of Entre Rios) |
1 | N. B. Vicente, J. E. Diaz-Zamboni, J. F. Adur, M. F. Izaguirre, C. D. Galetto, and V. H. Casco, "Development of a semiautomatic algorithm for deconvolution and quantification of three-dimensional microscopy images," A. Microscópia 19, 328-336 (2010). |
2 | X. Lai, Z. Lin, E. S. Ward, and R. J. Ober, "Noise suppression of point spread functions and its influence on deconvolution of three-dimensional fluorescence microscopy image sets," J. Microsc. 217, 93-108 (2005). DOI ScienceOn |
3 | A. Marian, F. Charriere, T. Colomb, F. Montfort, J. Kuhn, P. Marquet, and C. Depeursinge, "On the complex threedimensional amplitude point spread function of lenses and microscope objectives: theoretical aspects, simulations and measurements by digital holography," J. Microsc. 225, 156-169 (2007). DOI ScienceOn |
4 | J. F. Adur, "Determinación de las propiedades ópticas de un sistema de epifluorescencia y su utilización en estudios de microscopía cuantitativa 3D," Biomedical Engineer Magister Thesis, Faculty of Engineering-Bioengineering, Entre Ríos National University, Argentina (2006). |
5 | S. Shin and Y. Yu, "Three-dimensional information and refractive index measurement using a dual-wavelength digital holographic microscope," J. Opt. Soc. Korea 13, 173-177 (2009). DOI ScienceOn |
6 | B. Lee, N. Shin, K. Jeong, M. J. Park, B. G. Kim, J. H. Yoo, D. G. Kim, K. H. Yun, K. Lee, K. H. Kim, D. K. Kim, and S. H. Park, "Nondestructive optical measurement of refractive-index profile of graded-index lenses," J. Opt. Soc. Korea 13, 468-471 (2009). 과학기술학회마을 DOI ScienceOn |
7 | Y. Urata, S. J. Parmelee, D. A. Agard, and J. W. Sedat, "A three-dimensional structural dissection of Drosophila polytene chromosomes," J. Cell. Biol. 2, 279-295 (1995). |
8 | T. C. Wei, D. H. Shin, and B. G. Lee, "Resolution-enhanced reconstruction of 3D object using depth-reversed elemental images for partially occluded object recognition," J. Opt. Soc. Korea 13, 139-145 (2009). DOI ScienceOn |
9 | A. Diaspro, F. Federici, and M. Robello, "Influence of refractive-index mismatch in high-resolution threedimensional confocal microscopy," Appl. Opt. 41, 685-690 (2002). DOI |
10 | J. W. Shaevitz and D. A. Fletcher, "Enhanced three-dimensional deconvolution microscopy using a measured depth-varying point-spread function," J. Opt. Soc. Am. A 24, 2622-2627 (2007). DOI ScienceOn |
11 | W. A. Carrington, K. E. Fogarty, and F. S. Fay, "3D fluorescence imaging of single cells using image restoration," in Noninvasive Techniques in Cell Biology, K. Foskett and S. Grinstein, eds. (Wiley-Liss, New York, USA, 1990). |
12 | H. Wei and J. Zhongliang, "Evaluation of focus measures in multi-focus image fusion," Pattern Recog. Lett. 28, 493-500 (2007). DOI ScienceOn |
13 | J. Adur and J. Schlegel, "Design, development and construction of an advance micrometric system for microscopes," Bioengineering Degree Thesis, Faculty of Engineering- Bioengineering, Entre Ríos National University, Argentina (1997). |
14 | J. E. Diaz-Zamboni, "Software to users of desconvolution digital microscopy," Bioengineering Degree Thesis, Faculty of Engineering-Bioengineering, Entre Ríos National University, Argentina (2004). |
15 | K. L. Gosner, "A simplified table for stanging anuran embryos and larval with noter on identification," Herpetologica 16, 183-190 (1960). |
16 | M. F. Izaguirre, D. Larrea, J. F. Adur, J. E. Diaz-Zamboni, N. B. Vicente, C. D. Galetto, and V. H. Casco, "E-cadherin role in epithelial architecture maintenance," Cell. Commun. Adhes. 2, 1-12 (2010). |
17 | S. Grgic, M. Grgic, and M. Mrak, "Reliability of objective picture quality measures," J. Elect. Engineering 55, 3-10 (2004). |
18 | Y. Yao, B. R. Abidi, and M. A. Abidi, "Extreme zoom surveillance: system design and image restoration," J. Multimedia 2, 20-31 (2007). |
19 | K. R. Castleman, Digital Image Processing (Prentice Hall, New Jersey, USA, 1996), Chapter 9. |
20 | C. Preza and J. Conchello, "Image estimation accounting for point-spread function depth variation in threedimensional fluorescence microscopy," Proc. SPIE 4964, 135-142 (2003). DOI |
21 | Y. Hiraoka, J. W. Sedat, and D. A. Agard, "Determination of three-dimensional imaging properties of a light microscope system. Partial confocal behavior in epifluorescence microscopy," Biophys. J. 57, 325-333 (1990). DOI ScienceOn |
22 | J. A. Conchello and J. W. Lichtman, "Optical sectioning microscopy," Nat. Methods 12, 920-931 (2005). |
23 | J. C. McNally, T. Karpova, J. Cooper, and J. A. Conchello, "Three-dimensional imaging by deconvolution microscopy," Methods 19, 373-385 (1999). DOI ScienceOn |
24 | P. Sarder and A. Nehorai, "Deconvolution methods for 3D fluorescence microscopy images," IEEE Sig. Proc. Mag. 23, 32-45 (2006). DOI ScienceOn |
25 | S. F. Gibson and F. Lanni, "Experimental test of an analytical model of aberration in an oil-immersion objective lens used in three-dimensional light microscopy," J. Opt. Soc. Am. A 1, 154-166 (1992). |
26 | M. Abramowitz, K. R. Spring, H. E. Keller, and M. W. Davidson, "Basic principles of microscope objectives," Biotechniques 33, 772-781 (2002). |
27 | J. B. Pawley, Handbook of Biological Confocal Microscopy (Springer Press, New York, USA, 1995), Chapter 7. |
28 | J. B. Pawley, Handbook of Biological Confocal Microscopy (Springer Press, New York, USA, 1995), Chapter 20. |
29 | J. B. Sibarita, "Deconvolution microscopy," Adv. Biochem. Eng. Biotechnol. 95, 201-243 (2005). |
30 | J. G. McNally, C. Preza, J. A. Conchello, and L. J. Jr. Thomas, "Artifacts in computational optical-sectioning microscopy," J. Opt. Soc. Am. A 11, 1056-1067 (1994). DOI ScienceOn |
31 | B. A. Scalettar, J. R. Swedlow, J. W. Sedat, and D. A. Agard, "Dispersion, aberration and deconvolution in multi-wavelength fluorescence images," J. Microsc. 1, 50-60 (1996). |
32 | D. Agard, "Optical sectioning microscopy: cellular architecture in three dimensions," Annu. Rev. Biophys. Bioeng. 13, 191-219 (1984). DOI |
33 | M. Kozubek, "Theoretical versus experimental resolution in optical microscopy," Microsc. Res. Tech. 2, 157-166 (2001). |