• Title/Summary/Keyword: Image Transformation

Search Result 1,071, Processing Time 0.025 seconds

Formation of YSZ Coatings Deposited by Suspension Vacuum Plasma Spraying (서스펜션 진공 플라즈마 용사법을 통한 YSZ 코팅의 형성)

  • Yoo, Yeon Woo;Byon, Eungsun
    • Journal of the Korean institute of surface engineering
    • /
    • v.50 no.6
    • /
    • pp.460-464
    • /
    • 2017
  • As increasing thermal efficiency of the gas turbine, the performance improvement of thermal barrier coatings is also becoming important. Ytrria stabilized zirconia(YSZ) is the most popular materials for ceramic top coating because of its low thermal conductivity. In order to enhance the performance of thermal barrier coatings for hot sections in the gas turbine, suspension plasma spraying was developed in order to feed nano-sized powders. YSZ coatings formed by suspension plasma spraying showed better performance than YSZ coatings due to its exclusive microstructure. In this research, two YSZ coatings were deposited by suspension vacuum plasma spraying at 400 mbar and 250 mbar. Microstructures of YSZ coatings were analyzed by scanning electron image(SEM) on each spraying conditions, respectively. Crystalline structure transformation was not detected by X-ray diffraction. Thermal conductivity of suspension vacuum plasma sprayed YSZ coatings were measured by laser flash analysis. Thermal conductivity of suspension vacuum plasma sprayed YSZ coatings containing horizontally oriented nano-sized pores and vertical cracks showed $0.6-1.0W/m{\cdot}K$, similar to thermal conductivity of YSZ coatings formed by atmospheric plasma spraying.

Robust Watermarking in Medical Images Using by Polar Transformation (의료영상에서 Polar 변환을 적용한 강인한 워터마킹 기법)

  • 남기철;박무훈
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.8 no.2
    • /
    • pp.379-385
    • /
    • 2004
  • Medical images are being managed more by PACS in general medical institutions. It is important to protect patients from being invaded their privacy related to the images. It is also necessary to confirm the ownership, the right of property of the medical images and notice whether the data are modified. In this paper, we propose a robust watermarking against RST attacks in medical images on the PACS. The proposed scheme modifies and improves Log-Polar Mapping and Fourier Mellin Transform in order to realize and recover serious image degradation and watermark data loss caused by the conversion between cartesian coordinate and log-polar coordinate. We used the radius and theta Look Up Table to solve the realization of the Fourier Mellin Transform, and inserted a watermark into 2D-DFT magnitudes using Spread Spectrum. Experimental results shows that this method are robust to rotation attack.

A Novel Adaptive Histogram Equalization based on Histogram Matching (히스토그램 매칭에 기반한 적응적 히스토그램 균등화)

  • Min, Byong-Seok
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.7 no.6
    • /
    • pp.1231-1236
    • /
    • 2006
  • The contrast control of images with narrow dynamic range is a simple method among enhancement methods for low intensity of image. Histogram equalization is the most common method for this purpose, which stretches the dynamic range of intensity Conventional methods would fail to enhance images with extremely dark and bright regions, because of not considering the shape of histogram. In this paper, we propose a novel adaptive histogram equalization based on histogram matching with multiple Gaussian transformation function. As a result, output images with a couple of peaks of histogram could be improved and the details such as edges in dark regions could be appeared better than conventional method subjectively.

  • PDF

Thermal Expansion Coefficient Measurement of STS430 at High Temperature by In-plane ESPI (In-plane ESPI를 이용한 고온에서 STS430의 열팽창계수 측정)

  • 김경석;강기수;장호섭
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.21 no.11
    • /
    • pp.69-74
    • /
    • 2004
  • This paper presents ESPI system for the measurement of thermal expansion coefficient of STS430 up to 1,00$0^{\circ}C$ . Existing methods, strain gauge and moire have the limitation of contact to object and do not supply the coefficient up to 80$0^{\circ}C$ . There needs to measure the data up to 80$0^{\circ}C$, because heat resistant materials have high melting temperature up to 1,000'E In previous studies related to thermal strain analysis, the quantitative results have not reported by ESPI at high temperature, yet. In-plane ESPI and vacuum chamber for the reduction of air turbulence and oxidation are designed for the measurement of the coefficient up to 1,00$0^{\circ}C$ and speckle correlation fringe pattern images are processed by commercial image filtering tool-smoothing, thinning and enhancement- to obtain quantitative results, which is compared with references data. The comparison shows two data are agreed within 4.1% blow $600^{\circ}C$ however, there is some difference up to $600^{\circ}C$. Also, the incremental ratio of the coefficient is changed up to 80$0^{\circ}C$ . The reason is the phase transformation of STS430 probably begins at 80$0^{\circ}C$

Face Recognition Using Modified Two-Dimensional PCA (변형된 이차원 PCA를 이용한 얼굴 인식)

  • Kim Young-Gil;Song Young-Jun;Chang Un-Dong;Kim Dong-Woo;Ahn Jae-Hyeong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.6 no.4
    • /
    • pp.291-295
    • /
    • 2005
  • In this paper, we propose a face recognition method using modified 2-D PCA. While the previous PCA method computes the covariance matrix by using one dimensional vectors, the 2-D PCA method computes the covariance matrix by directly using direct two dimensional image, and extracts the feature vectors by solving eigenvalue problem. The proposed method recognizes the faces by applying the modified 2-D PCA to face images and it gets linear transformation matrix using two covariance matrices. The experimental results indicates that the proposed method improved about $1\%$ and achieved more stability in recognition rate than conventional 2-D PCA.

  • PDF

Realization for Moving Object Sensing and Path Tracking System using Stereo Line CCDs (스테레오 라인 CCD를 이용한 이동객체감지 및 경로추적 시스템 구현)

  • Ryu, Kwang-Ryol;Kim, Young-Bin
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.12 no.11
    • /
    • pp.2050-2056
    • /
    • 2008
  • A realization for moving object sensing and tracking system in two dimensional plane using stereo line CCDs and lighting source is presented in this paper. The system is realized that instead of processing camera images directly, two line CCD sensor and input line image is used to measure two dimensional distance by comparing the brightness on line CCDs. The algorithms are used the moving object sensing, path tracking and coordinate converting method. To ensure the effective detection of moving path, a detection algorithm to evaluate the reliability of each measured distance is developed. The realized system results are that the performance of moving object recognizing shows 5mm resolution, and enables to track a moving path of object per looms period.

A giant trichoblastic carcinoma

  • Lee, Joon Seok;Kwon, Joon Hyun;Jung, Gyu Sik;Lee, Jeong Woo;Yang, Jung Dug;Chung, Ho Yun;Cho, Byung Chae;Choi, Kang Young
    • Archives of Craniofacial Surgery
    • /
    • v.19 no.4
    • /
    • pp.275-278
    • /
    • 2018
  • Trichoblastic carcinoma usually occurs as a malignant transformation of the trichoblastoma, but is very rare. A 25-year-old man was admitted with trichoblastoma in the nuchal area with frequent recurrences since birth. The preoperative neck magnetic resonance image revealed lobulated soft tissue lesions involving superficial fascia and infiltrating into both proximal trapezius muscles. In our department, wide excision and reconstruction with a free anterolateral thigh flap were performed. Histological examination revealed skin adnexal carcinoma, originating from the hair follicles, consistent with trichoblastic carcinoma. There was no palpable mass 5 years postoperatively, and there was no recurrence on follow-up positron emission tomography-computed tomography. Trichoblastic carcinomas are rare and difficult to diagnose, but histopathological findings include atypical basaloid keratinocytes with crowded, hyperchromatic nuclei, and increased mitotic activity. The presence of hypercellular stroma is a criterion for distinguishing trichoblastic carcinoma from basal cell carcinoma. A rare giant trichoblastic carcinoma was reported, which was the biggest one in the literature.

Real-time geometry identification of moving ships by computer vision techniques in bridge area

  • Li, Shunlong;Guo, Yapeng;Xu, Yang;Li, Zhonglong
    • Smart Structures and Systems
    • /
    • v.23 no.4
    • /
    • pp.359-371
    • /
    • 2019
  • As part of a structural health monitoring system, the relative geometric relationship between a ship and bridge has been recognized as important for bridge authorities and ship owners to avoid ship-bridge collision. This study proposes a novel computer vision method for the real-time geometric parameter identification of moving ships based on a single shot multibox detector (SSD) by using transfer learning techniques and monocular vision. The identification framework consists of ship detection (coarse scale) and geometric parameter calculation (fine scale) modules. For the ship detection, the SSD, which is a deep learning algorithm, was employed and fine-tuned by ship image samples downloaded from the Internet to obtain the rectangle regions of interest in the coarse scale. Subsequently, for the geometric parameter calculation, an accurate ship contour is created using morphological operations within the saturation channel in hue, saturation, and value color space. Furthermore, a local coordinate system was constructed using projective geometry transformation to calculate the geometric parameters of ships, such as width, length, height, localization, and velocity. The application of the proposed method to in situ video images, obtained from cameras set on the girder of the Wuhan Yangtze River Bridge above the shipping channel, confirmed the efficiency, accuracy, and effectiveness of the proposed method.

Deformation estimation of truss bridges using two-stage optimization from cameras

  • Jau-Yu Chou;Chia-Ming Chang
    • Smart Structures and Systems
    • /
    • v.31 no.4
    • /
    • pp.409-419
    • /
    • 2023
  • Structural integrity can be accessed from dynamic deformations of structures. Moreover, dynamic deformations can be acquired from non-contact sensors such as video cameras. Kanade-Lucas-Tomasi (KLT) algorithm is one of the commonly used methods for motion tracking. However, averaging throughout the extracted features would induce bias in the measurement. In addition, pixel-wise measurements can be converted to physical units through camera intrinsic. Still, the depth information is unreachable without prior knowledge of the space information. The assigned homogeneous coordinates would then mismatch manually selected feature points, resulting in measurement errors during coordinate transformation. In this study, a two-stage optimization method for video-based measurements is proposed. The manually selected feature points are first optimized by minimizing the errors compared with the homogeneous coordinate. Then, the optimized points are utilized for the KLT algorithm to extract displacements through inverse projection. Two additional criteria are employed to eliminate outliers from KLT, resulting in more reliable displacement responses. The second-stage optimization subsequently fine-tunes the geometry of the selected coordinates. The optimization process also considers the number of interpolation points at different depths of an image to reduce the effect of out-of-plane motions. As a result, the proposed method is numerically investigated by using a truss bridge as a physics-based graphic model (PBGM) to extract high-accuracy displacements from recorded videos under various capturing angles and structural conditions.

Application of RTI to Improve Image Clarity of a Trace Fossil Cochlichnus Found from the Jinju and Haman Formations

  • Sangho Won;Dal-Yong Kong
    • Economic and Environmental Geology
    • /
    • v.56 no.4
    • /
    • pp.397-408
    • /
    • 2023
  • A total of 64 specimens of trace fossils were collected from the Jinju Formation of the construction site of Jinju Aviation Industrial Complex, and from the Haman Formation of Namhae Gain-ri fossil site. The fossils are continuously and regularly meandering sine-curve in shape. The fossil varies in morphology: width between 0.2 and 5.6 mm, wavelength between 1.5 and 28 mm, and amplitude between 0.9 and 7.9 mm; the Jinju specimens are commonly wider than the Haman ones. The ratio of wavelength to amplitude is more or less regular regardless of width of the specimen, and the linear correlation of the ratios shows that the Jinju specimens fit better than the Haman specimens. Taking all morphometric parameters, specimens in all size ranges are temporarily identified as ichnospecies Cochlichnus anguineus. In order to obtain more distinct and clearer images of Cochlichnus, we selected two specimens and applied a new imaging technology RTI. For photography of the trace fossils, 50 to 80 images were taken per set with photometric lighting close to the surface and horizontally. RTI technology clearly showed that the images of tiny fossils were improved: the surface contrast become sharper and messy and unnecessary information disappeared. Currently, RTI technology is used in many fields including preservation of cultural properties and archaeology. As a consequence, we hope to apply this technique to the field of paleontology, especially to the study of trace fossils of very small size.