• Title/Summary/Keyword: Image Transfer

Search Result 944, Processing Time 0.031 seconds

Study on the Resolution Characteristics by Using Magnetic Resonance Imaging 3.0T (3.0T 자기공명영상을 이용한 해상력 특성에 대한 연구)

  • Min, Jung-Whan;Jeong, Hoi-Woun;Han, Ji-Hyun;Lee, Si-Nae;Han, Song-Yi;Kim, Ki-Won;Kim, Hyun-Soo;Son, Jin-Hyun
    • Journal of radiological science and technology
    • /
    • v.43 no.4
    • /
    • pp.251-257
    • /
    • 2020
  • This study was purpose to quantitative evaluation of edge method of modulation transfer function(MTF) and physical image characteristics of by obtain the optimal edge image by using magnetic resonance imaging(MRI). The MRI equipment was used (MAGNETOM Vida 3.0T MRI, Siemense healthcare system, Germany) and the head/neck matrix shim MR coil were 20 channels(elements) receive coil. The MTF results of showed the best value of 0.294 based on the T2 Nyquist frequency of 1.0 mm-1. The MTF results of showed that the T1 image is 0.160, the T1 CE image is 0.250, T1 Conca2 image is 0.043, and the T1 CE (Concatenation) Conca2 image is 0.190. The T2 image highest quantitatively value for MTF. The physical image characteristics of this study were to that can be used efficiently of the MRI and to present the quantitative evaluation method and physical image characteristics of 3.0T MRI.

3D Modeling of a Fabric based on its 3D Microstructure Image and Application of the Model of the Numerical Simulation of Heat Transfer

  • Lee, Hyojeong;Lee, Heeran;Eom, Ran-i;Lee, Yejin
    • Journal of Fashion Business
    • /
    • v.20 no.3
    • /
    • pp.30-42
    • /
    • 2016
  • The objective of this study was to perform 3D solid modeling from 3D scanned surface images of cotton and silk in order to calculate the thermal heat transfer responses using numerical simulations. Continuing from the previous methodology, which provided 3D surface data for a fabric through optical measurements of the fabric microstructure, a simplified 3D solid model, containing a defined unit cell, pattern unit and fabric structure, was prepared. The loft method was used for 3D solid-model generation, and heat transfer calculations, made for the fabric, were then carried out using the 3D solid model. As a result, comprehensive protocols for 3D solid-model generation were established based on the optical measurements of real fabric samples. This method provides an effective means of using 3D information for building 3D models of actual fabrics and applying the model in numerical simulations. The developed process can be used as the basis for other analogous research areas to investigate the physical characteristics of any fabrics.

A Study of Multi-Channel Video Transfer System with EBCOT (EBCOT를 이용한 다 채널 영상 전송 시스템에 대한 연구)

  • 추연학;김영민
    • Journal of Korea Multimedia Society
    • /
    • v.4 no.1
    • /
    • pp.75-81
    • /
    • 2001
  • A EBCOT(Embedded Block Coding with Optimized Truncation) is image compression codec using in JPEG2000, currently the new standard for still image coding. this paper proposes multi-channel video transfer system with EBCOT using a single codec to transfer video to difference band-width channel. This parer testify that compression rate of EBCOT higher than ordinary VLC using RLC and Huffman codec and apply EBCOT to JPEG structure. this structure increases parallelism and error resilience using black coding method. finally it looks into difficult to apply MPEG structure to multi channel video transfer system, and proposes solution using EBCOT.

  • PDF

Theory of High Resolution TEM Image Formation: Coherence (1) (TEM 관련 이론해설 (6): 투과전자현미경의 고분해능 영상이론: 결맞음 (1))

  • Lee, Hwack-Joo
    • Applied Microscopy
    • /
    • v.35 no.3
    • /
    • pp.105-112
    • /
    • 2005
  • In this review, the important ideas of coherence theory are introduced. The transfer function and damping envelopes of the microscope due to temporal and spatial coherence are described. The passbands and the condition of Scherzer focus are also disscussed in associated with the resolution of transmission electron microscope.

Heat Transfer Characteristics of a Slot Jet and Circular Jets Impinging on a Flat Surface (벽면에 충돌하는 슬롯형 제트와 원형 제트의 열전달 효과 비교)

  • Kim, Hui-Hyun;Kim, Dae-Seong;Yoon, Soon-Hyun
    • Proceedings of the KSME Conference
    • /
    • 2001.06d
    • /
    • pp.540-545
    • /
    • 2001
  • An experimental study was conducted to compare the heat transfer characteristics of an impinging slot jet and three kinds of impinging circular jets. Thermochromic liquid crystal with an image processing system was employed to measure the temperature of impinging wall where constant heat flux condition was applied. The distribution of convective heat transfer coefficients were then evaluated for eight nozzle-to-surface distance settings for each jet cases. The cooling effect was linearly proportional to the number of nozzles for circular jet cases at the same nozzle exit speed. However, the heat transfer under constant volume flow rate was the most at single circular jet. It was concluded that the overall convective heat transfer was better at the circular jets than the slot jet.

  • PDF

Comparison Study of the Modulation Transfer Function of a Prototype a-Se based Flat Panel Detector with Conventional Speed Class 400 Film/screen System (비정질 셀레늄을 이용한 직접방식의 디지털 방사선 검출기와 X-ray film과의 MTF측정을 통한 영상 질(quality) 비교평가에 관한 연구)

  • Park, Jang-Yong;Park, Ji-Koon;Kang, Sang-Sik;Moon, Chi-Woong;Lee, Hyung-Won;Nam, Sang-Hee
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.40 no.3
    • /
    • pp.163-171
    • /
    • 2003
  • To evaluate the performance of the digital radiography(DR) system developed in our group, the modulation transfer function(MTF) was measured and compared with that of an analog X- ray detector, film/screen system. The DR system has an amorphous selenium(a-Se) layer vacuum-evaporated on a TFT flat panel detector. The speed class 400 film/screen (Fuji) system has been being used in the clinical field as analog X-ray detectors. Both the square wave and slit method were used to evaluate their MTF. The square method was applied to both film/screen and the DR system. The slit method, however, was applied to only DR system. The full-width half maximum resolution of film/screen was 357${\mu}{\textrm}{m}$(1.4 lp/mm at 50% spatial frequency), and the resolution of DR was limited to 200${\mu}{\textrm}{m}$(2.5 lp/mm at 30%). These results indicate the measured resolution limitations approximate to the pixel pitch, 139 ${\mu}{\textrm}{m}$ of TFT. The MTF of DR is higher than that of film/screen by the factor of 1.785. It is proved that our a-Se based DR system has potential usefulness in the clinical field.

NIIRS ESTIMATION USING THE GENERAL IMAGE-QUALITY EQUATION FOR MONITORING IMAGE DEGRADATION

  • Kim, Dong-Wook;Kim, Tae-Jung;Kim, Hee-Seob
    • Proceedings of the KSRS Conference
    • /
    • 2008.10a
    • /
    • pp.53-56
    • /
    • 2008
  • Generally, the quality of satellite images is expressed by GSD (Ground Sample Distance), MTF (Modulation Transfer Function) and SNR (Signal to Noise Ratio). However, these factors are technology-oriented and do not explain interpretability of satellite images. We need a standardized index which shows standard of interpretability. In this study, we estimated NIIRS (National Imagery Interpretability Rating Scale) through the GIQE (General Image Quality Equation) which is able to judge image interpretability with the standardized index. Traditionally, NIIRS has been determined manually by specialized image analysts. We used the GIQE in order to reduce inefficiency and high costs cause by manual interpretation and to produce accurate NIIRS. For monitoring image degradation, we estimated GIQE physical parameters from image analysis and carried out time series analysis about the quality of the KOMPSAT-1 images. On all of the tests, we were able to identify the image degradation due to the changing time. This indicates that NIIRS derived from GIQE will be used for image degradation indicator.

  • PDF

Quality Evaluation of Drone Image using Siemens star (Siemens star를 이용한 드론 영상의 품질 평가)

  • Lee, Jae One;Sung, Sang Min;Back, Ki Suk;Yun, Bu Yeol
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.40 no.3
    • /
    • pp.217-226
    • /
    • 2022
  • In the view of the application of high-precision spatial information production, UAV (Umanned Aerial Vehicle)-Photogrammetry has a problem in that it lacks specific procedures and detailed regulations for quantitative quality verification methods or certification of captured images. In addition, test tools for UAV image quality assessment use only the GSD (Ground Sample Distance), not MTF (Modulation Transfer Function), which reflects image resolution and contrast at the same time. This fact makes often the quality of UAV image inferior to that of manned aerial image. We performed MTF and GSD analysis simultaneously using a siemens star to confirm the necessity of MTF analysis in UAV image quality assessment. The analyzing results of UAV images taken with different payload and sensors show that there is a big difference in σMTF values, representing image resolution and the degree of contrast, but slightly different in GSD. It concluded that the MTF analysis is a more objective and reliable analysis method than just the GSD analysis method, and high-quality drone images can only be obtained when the operator make images after judging the proper selection the sensor performance, image overlaps, and payload type. However, the results of this study are derived from analyzing only images acquired by limited sensors and imaging conditions. It is therefore expected that more objective and reliable results will be obtained if continuous research is conducted by accumulating various experimental data in related fields in the future.

Recognition and Visualization of Crack on Concrete Wall using Deep Learning and Transfer Learning (딥러닝과 전이학습을 이용한 콘크리트 균열 인식 및 시각화)

  • Lee, Sang-Ik;Yang, Gyeong-Mo;Lee, Jemyung;Lee, Jong-Hyuk;Jeong, Yeong-Joon;Lee, Jun-Gu;Choi, Won
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.61 no.3
    • /
    • pp.55-65
    • /
    • 2019
  • Although crack on concrete exists from its early formation, crack requires attention as it affects stiffness of structure and can lead demolition of structure as it grows. Detecting cracks on concrete is needed to take action prior to performance degradation of structure, and deep learning can be utilized for it. In this study, transfer learning, one of the deep learning techniques, was used to detect the crack, as the amount of crack's image data was limited. Pre-trained Inception-v3 was applied as a base model for the transfer learning. Web scrapping was utilized to fetch images of concrete wall with or without crack from web. In the recognition of crack, image post-process including changing size or removing color were applied. In the visualization of crack, source images divided into 30px, 50px or 100px size were used as input data, and different numbers of input data per category were applied for each case. With the results of visualized crack image, false positive and false negative errors were examined. Highest accuracy for the recognizing crack was achieved when the source images were adjusted into 224px size under gray-scale. In visualization, the result using 50 data per category under 100px interval size showed the smallest error. With regard to the false positive error, the best result was obtained using 400 data per category, and regarding to the false negative error, the case using 50 data per category showed the best result.

Development of Image Quality Evaluation Program for Digital Diagnostic Radiography (디지털진단의료영상 화질평가 프로그램 개발)

  • Kang, Bo-Sun
    • Journal of the Korean Society of Radiology
    • /
    • v.2 no.2
    • /
    • pp.5-10
    • /
    • 2008
  • Most of the diagnostic medical radiography are rapidly replaced by digital imaging systems recently. Although with the current transition of analog to digital most of the exposure conditions and parameters are still on the basis of film-screen analog system. Moreover the evaluation of acquired digital radiographic image is not fulfilled normally because of the difficulties in handling the digital raw data. The user friendly windows program for the evaluations of digital radiographic image was developed on the MatLab platform. The program has functions for the calculation of the contrast profile, NPS(noise power spectrum), MTF(modulation transfer function), and NEQ(noise equivalent quanta).

  • PDF