• Title/Summary/Keyword: Image Tracing

Search Result 242, Processing Time 0.026 seconds

A Study on Indoor Propagation Modeling using Patch Scattering Model (패치산란모델을 이용한 실내 전파모델링에 관한 연구)

  • 석우찬;김진웅;석재호;임재우;윤영중
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.12 no.5
    • /
    • pp.722-733
    • /
    • 2001
  • In this paper, we proposed the image-based 3D ray-tracing indoor propagation model using patch scattering model which can calculate the scattering phenomenon of the indoor structures. A patch scattering model for modeling indoor structures defines a scattering phenomenon by using RCS(Radar Cross Section) about rectangular patch without complex calculation, for example generating image antennas about each indoor structures. RCS is simply defined as a ratio of scattering power to incident power, and we use bistatic PCS which is simplified numerically by Physical Optics. Also, a simple indoor compensation factor is defined as empirical constant from measured data instead of complex numerical expression because basic patch scattering model cannot include important multipath components, so we san use patch scattering model in indoor environment using indoor compensation factor.

  • PDF

A STUDY ON SIMULATION OF THE MANDIBULAR MOVEMENT OF THE PATIENTS WITH TEMPOROMANDIBULAR JOINT DISORDER (측두하악 장애환자의 하악 운동 Simulation에 관한 연구)

  • Park, Sang-Yoon;Kang, Dong-Wan;Kay, Kee-Sung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.29 no.2
    • /
    • pp.161-175
    • /
    • 1991
  • To understand the biomechanics of the mandibular movement of the patients with T.M.J. disorder, it is necessary to analyze the mandibular movement by the least moving points of instantaneous center of rotation on computer screen. In this study, two subjects without T.M.J. disorder and with normal occlusion and few patients with T.M.J. disorder were selected for obtaining the processing data. The habitual opening and dosing movements were recorded by image recognition system of video and computer and then the mandibular movement and the least moving point were analyzed using computer program for image anaysis of specialized points. The results obtained were as follows: 1. The least moving points of control group during opening and dosing were dose to the mandibular foramen, but in the test group there were differences between two positions of the least moving points during opening and closing. 2. The variations of the least moving point were in the range of $0.02\sim0.05cm$ of X-coordinate and $0.07\sim0.10cm$ of Y-coordinate for control group, whereas in the range of $0.05\sim0.30cm$ of X-coordinate and $0.08\sim1.65cm$ of Y-coordinate for test group. 3. The index of variation during opening and dosing movements was shown in $0.8\sim1.0$ for the control group and in $0.56\sim2.6$ for the test group. 4. After the treatment of the test group No. 4 by occlusal splint the least moving point was dose to the mandibular foramen and the index of variation was changed from 25 to 05. 5. The tracing shape of the least moving point in the test group represented the irregularities compared to the control group. 6. The mandibular opening and dosing movements were simulated on the computer screen following the movement of the least moving point of instantaneous center of rotation.

  • PDF

Fast Implementations of Projector-Backprojector Pairs for Iterative Tomographic Reconstruction (반복법을 사용한 단층영상 재구성을 위한 투사기 및 역투사기의 고속 구현)

  • 김수미;이수진;김용호
    • Journal of Biomedical Engineering Research
    • /
    • v.24 no.5
    • /
    • pp.473-480
    • /
    • 2003
  • Iterative reconstruction methods have played a prominent role in emission computed tomography due to their remarkable advantages over the conventional filtered backprojection method. However, since iterative reconstructions typically are comprised of repeatedly projecting and backprojecting the data, the computational load required for reconstructing an image depends highly on the performance of the projector-backprojector pair used in the algorithm. In this work we compare quantitative performance of representative methods for implementing projector-backprojector pairs. To reduce the overall cost for the projection-backprojection operations for each method, we investigate how previously computed results can be reused so that the number of redundant calculations can be minimized. Our experimental results demonstrate that the ray tracing method not only outperforms other methods in computation time, but also provides improved reconstructions with good accuracy.

Forward-Looking Ultrasound Imaging Transducer : I. Analysis and Design (전향 초음파 영상 트랜스듀서 : I. 해석 및 설계)

  • Lee, Chan-Kil
    • The Journal of the Acoustical Society of Korea
    • /
    • v.14 no.2E
    • /
    • pp.73-86
    • /
    • 1995
  • The transducer section of the forward-looking ultrasound imaging catheter (FLUIC) consists of a circular piezoelectric element as a vibrator and a conical acoustic mirror as a perfect reflector. A small diameter piezoelectric transducer element is mounted on the side of a catheter's rotating shaft. The unique design of FLUIC provides the capability to form a two-dimensional image of a cross-section of vessel in front of the catheter, which is lacking in the present generation of intravascular ultrasound (IVUS) transducers, as well as a conventional side view image. The mirror configuration for the transducer section of the FLUIC is designed using an approximated ray tracing techniques. The diffraction transfer function approach [1] developed for the field prediction from primary sources is generalized and extended to predict the secondary diffraction characterstics from an acoustic mirror. The extended model is verified by simulation and experiment through a simple plane reflector and employed to analyzed the field characteristics of a FLUIC.

  • PDF

FABRICATION AND ALIGNMENT OF PARTS OF THE KASINICS OFFNER SYSTEM (KASINICS 오프닝 광학계의 부품 가공 및 정렬)

  • Mok, Seung-Won;Lee, Sung-Ho;Yuk, In-Soo;Park, Young-Sik;Jin, Ho;Han, Jeong-Yeo;Moon, Bong-Kon;Cha, Sang-Mok;Kim, Geon-Hee;Im, Myung-Shin
    • Publications of The Korean Astronomical Society
    • /
    • v.21 no.2
    • /
    • pp.43-49
    • /
    • 2006
  • The KASINICS (KASI Near Infrared Camera System) is a ground-based Near-Infrared (NIR) imaging instrument developed by the Korea Astronomy and Space Science Institute (KASI). In this paper, we report the test results of the KASINICS camera optics system which is comprised of a 1-1 Offner relay. We measure that the surface RMS fluctuations of the Offner mirrors are at the level of $10^{-1}-10^{-2}$ of the target wavelengths, showing that the mirrors are sufficiently smooth for NIR observations. The alignment of the Offner optics system has been checked too. Our ray-tracing simulations find that the image quality should not degrade more than the pixel size of the KASINICS ($40{\mu}m$), if a de-centering or a tilt of the Offner mirrors are within 5mm, or $2.5^{\circ}$. Our measurement shows that the de-centering or the tilt of the Offner mirrors are less than 1 mm or $0.5^{\circ}$, assuring that the KASINICS image quality are not affected by the alignment errors. We have also measured that the optics resolution is $20{\mu}m$ and it does not degrade more than 10% over the detector surface area of 14.3 mm ${/times}$ 14.3mm. Overall, we conclude that the KASINICS optics system satisfies the design requirements for NIR imaging observations.

A vision-based system for dynamic displacement measurement of long-span bridges: algorithm and verification

  • Ye, X.W.;Ni, Y.Q.;Wai, T.T.;Wong, K.Y.;Zhang, X.M.;Xu, F.
    • Smart Structures and Systems
    • /
    • v.12 no.3_4
    • /
    • pp.363-379
    • /
    • 2013
  • Dynamic displacement of structures is an important index for in-service structural condition and behavior assessment, but accurate measurement of structural displacement for large-scale civil structures such as long-span bridges still remains as a challenging task. In this paper, a vision-based dynamic displacement measurement system with the use of digital image processing technology is developed, which is featured by its distinctive characteristics in non-contact, long-distance, and high-precision structural displacement measurement. The hardware of this system is mainly composed of a high-resolution industrial CCD (charge-coupled-device) digital camera and an extended-range zoom lens. Through continuously tracing and identifying a target on the structure, the structural displacement is derived through cross-correlation analysis between the predefined pattern and the captured digital images with the aid of a pattern matching algorithm. To validate the developed system, MTS tests of sinusoidal motions under different vibration frequencies and amplitudes and shaking table tests with different excitations (the El-Centro earthquake wave and a sinusoidal motion) are carried out. Additionally, in-situ verification experiments are performed to measure the mid-span vertical displacement of the suspension Tsing Ma Bridge in the operational condition and the cable-stayed Stonecutters Bridge during loading tests. The obtained results show that the developed system exhibits an excellent capability in real-time measurement of structural displacement and can serve as a good complement to the traditional sensors.

Implementation of Preceding Vehicle Break-Lamp Detection System using Selective Attention Model and YOLO (선택적 주의집중 모델과 YOLO를 이용한 선행 차량 정지등 검출 시스템 구현)

  • Lee, Woo-Beom
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.22 no.2
    • /
    • pp.85-90
    • /
    • 2021
  • A ADAS(Advanced Driver Assistance System) for the safe driving is an important area in autonumous car. Specially, a ADAS software using an image sensors attached in previous car is low in building cost, and utilizes for various purpose. A algorithm for detecting the break-lamp from the tail-lamp of preceding vehicle is proposed in this paper. This method can perceive the driving condition of preceding vehicle. Proposed method uses the YOLO techinicque that has a excellent performance in object tracing from real scene, and extracts the intensity variable region of break-lamp from HSV image of detected vehicle ROI(Region Of Interest). After detecting the candidate region of break-lamp, each isolated region is labeled. The break-lamp region is detected finally by using the proposed selective-attention model that percieves the shape-similarity of labeled candidate region. In order to evaluate the performance of the preceding vehicle break-lamp detection system implemented in this paper, we applied our system to the various driving images. As a results, implemented system showed successful results.

Automatic Boundary Detection of Carotid Intima-Media based on Multiresolution Snake (다해상도 스네이크를 통한 경동맥 내막-중막 경계선 자동추출)

  • Lee, Yu-Bu;Choi, Yoo-Joo;Kim, Myoung-Hee
    • The KIPS Transactions:PartA
    • /
    • v.14A no.2
    • /
    • pp.77-84
    • /
    • 2007
  • The intima media thickness(IMT) of the carotid artery from B mode ultrasound images has recently been proposed as the most useful index of individual atherosclerosis and can be used to predict major cardiovascular events. Ultrasonic measurements of the IMT are conventionally obtained by manually tracing interfaces between tissue layers. The drawbacks of this method are the inter and intra observer variability and its inefficiency. In this paper, we present a multiresolution snake method combined with the dynamic programming, which overcomes the various noises and sensitivity to initialization of conventional snake. First, an image pyramid is constructed using the Gaussian pyramid that maintains global edge information with smoothing in the images, and then the boundaries are automatically detected in the lowest resolution level by minimizing a cost function based on dynamic programming. The cost function includes cost terms which are representing image features and geometrical continuity of the vessel interfaces. Since the detected boundaries are selected as initial contour of the snake for the next level, this automated approach solves the problem of the initialization. Moreover, the proposed snake improves the problem of converging th the local minima by defining the external energy based on multiple image features. In this paper, our method has been validated by computing the correlation between manual and automatic measurements. This automated detection method has obtained more accurate and reproducible results than conventional edge detection by considering multiple image features.

Introduction of Hindfoot Coronal Alignment View (후족부 관상면 배열 영상에 대한 고안)

  • Moon, Il-Bong;Jeon, Ju-Seob;Yoon, Kang-Cheol;Choi, Nam-Kil;Kim, Seung-Kook
    • Journal of radiological science and technology
    • /
    • v.29 no.4
    • /
    • pp.225-228
    • /
    • 2006
  • Purpose: Accurate clinical evaluation of the alignment of the calcaneus relative to the tibia in the coronal plane is essential in the evaluation and treatment of hindfoot pathologic condition. Previously described standard anteroposterior, lateral, and oblique radiographic methods of the foot or ankle do not demonstrate alignment of the tibia relation to the calcaneus in the coronal plane. The purpose of this study was to introduce hindfoot coronal alignment view. Material : 1) Both feet were imaged simultaneously on an elevated, radiolucent foot stand equipment. 2) Both feet stood on a radiolucent platform with equal weight on both feet. 3) Both feet are located foot axis longitudinal perpendicular to the platform. 4) Silhouette tracing around both feet are made, and line is then drawn to bisect the silhouette of the second toe and the outline of the heel. 5) The x-ray beam is angled down approximately $15^{\circ} to $20^{\circ} Result : 1) This image described tibial axis and medial, lateral tuberosity of calcaneus. 2) Calcaneus do not rotated. 3) The view is showed by talotibial joint space. Conclusion: Although computed tomographic and magnetic resonance imaging techniques are capable of demonstrating coronal hindfoot alignment, they lack usefulness in most clinical situations because the foot is imaged in a non-weight bearing position. But hindfoot coronal alignment view is obtained for evaluating position changing of inversion, eversion of the hindfoot and varus, valgus deformity of calcaneus.

  • PDF

Study on the Selection of the Basin Characteristics Parameters in River Basin Using Satellite Images and GIS (위성영상(衛星映像)과 GIS를 이용한 하천유역(河川流域)의 유역특성인자(流域特性因子) 추출(抽出)추출 관한 연구(硏究))

  • Jo, Myung-Hee;Ahn, Seung-Seop
    • Journal of the Korean association of regional geographers
    • /
    • v.4 no.1
    • /
    • pp.121-134
    • /
    • 1998
  • In this study, the satellite images and the GIS technique are used to select the basin characteristics parameters as the basis of water resources management of river basin. The study area is Geum-ho river basin and the hydrologic characteristics data are computed through the database of the basin characteristics parameters classified by subjects with 35 maps correspond to the study basin of 1:25,000 scale as the basic map. As the result, the drawing up of land use map through satellite image processing that provides the quantitative informations for the land is very efficient to analysis the extensive land use information of the basin, and exact analysis of mass surface data is possible and the feasibility of statistic computation between spatial subjects as it superpose on other subject map is ascertained. It is thought also that the analysis of the basin characteristics data can be utilized very effectively for the basin management and the analysis of basin surface area, once it is expressed numerically for database, since the superposition analysis with different subject map and the correlative analysis with the property data are possible although the tracing process of each subject in the basic map is not efficient. Especially, modification and renewal of the data for the change of land surface become easy, therefore more rapid and exact selection of the basin characteristics data and the construction of more efficient basin management plan are possible.

  • PDF