• Title/Summary/Keyword: Image Integration(CI)

Search Result 8, Processing Time 0.026 seconds

CI Strategy for a Tourism Image Improvement at Chung-buk Cho-jeong (충북 초정리 관광 이미지 개선을 위한 CI 전략)

  • Lee, Yk-Su
    • The Journal of the Korea Contents Association
    • /
    • v.10 no.2
    • /
    • pp.444-451
    • /
    • 2010
  • The purpose of this study is about becomes the foundation which establishes the area image integrated strategy the area image and the major factor of the Cho-jeong. For a study result area image integration the considered seriously was self-combustion and creativity, according to demographics quality the possibility of knowing the fact that partially is difference of recognition. This will lead and for an area image integration from and will be natural to use the delegation of a district resources, the image integrated strategy which is discriminated must be established and the possibility.

A Study on corporate identity of hotel industy (호텔기업의 CI에 관한 연구)

  • Choi, Woong
    • Journal of Applied Tourism Food and Beverage Management and Research
    • /
    • v.9
    • /
    • pp.303-320
    • /
    • 1998
  • Today the corporate environment is changing rapidly in a standpoint of politics, economics, society and technology environment. So corporates need a management strategy in another point of view. As a new menagement strategy it is introduced corporate culture. The corporate culture should be built with the core of CI, in order to be adapted to peripheral circumstances of the company. The purpose of this thesis is to contribute to manage the systematic management of corporate image by inquiring into corporate identity. Through the research of the deluxe hotels in seoul it is tried to find hotel CI-concept. As a result, the knowledge level of hotel managers is a little low and considered simply as the modification of basic elements and development of a visual idenification system. The emphasis must be on the coordination and integration to create a desired coroporate image and to communicate this image created for the target audience in a systematic and unified mannr.

  • PDF

Classifier Integration Model for Image Classification (영상 분류를 위한 분류기 통합모델)

  • Park, Dong-Chul
    • Journal of the Institute of Electronics Engineers of Korea CI
    • /
    • v.49 no.2
    • /
    • pp.96-102
    • /
    • 2012
  • An advanced form of the Partitioned Feature-based Classifier with Expertise Table(PFC-ET) is proposed in this paper. As is the case with the PFC-ET, the proposed classifier model, called Classifier Integration Model(CIM), does not use the entire feature vectors extracted from the original data in a concatenated form to classify each datum, but rather uses groups of features related to each feature vector separately. The proposed CIM utilizes a proportion of selected cluster members instead of the expertise table in PFC-ET to minimize the error in confusion table. The proposed CIM is applied to the classification problem on two data sets, Caltech data set and collected terrain data sets. When compared with PFC model and PFC-ET model. the proposed CIM shows improvements in terms of classification accuracy and post processing efforts.

Image Identification Plan for SeJong-City Presidential Archives (세종시 대통령기록관 상설전시 연출을 위한 색채·전시사인 계획)

  • Lee, In-Ho;Lee, Heung-Wu;Kyung, Byung-Pyo;Ryu, Seuc-Ho
    • Journal of the Korea Convergence Society
    • /
    • v.9 no.12
    • /
    • pp.169-174
    • /
    • 2018
  • The museum, run by the archives, should show historical facts about the president through objective records that are not fully evaluated. The wartime atmosphere should maintain solemnity to highlight the evidential value of records about history, but include an interesting element that allows visitors to come comfortably. It would be possible to accommodate 360 viewers at the same time, and it would be an option to limit the number of visitors considering the operation of weekend events and the donor honor hall. In this study, we established and presented an image integration plan centered on the color plan and the signature plan. Although the real image integration plan is a case study that starts with symbols and logos and is conducted through an integrated and systematic system through the basic design and application design system, it is considered to be a meaningful study in terms of practical use.

A Study on Numeral Speech Recognition Using Integration of Speech and Visual Parameters under Noisy Environments (잡음환경에서 음성-영상 정보의 통합 처리를 사용한 숫자음 인식에 관한 연구)

  • Lee, Sang-Won;Park, In-Jung
    • Journal of the Institute of Electronics Engineers of Korea CI
    • /
    • v.38 no.3
    • /
    • pp.61-67
    • /
    • 2001
  • In this paper, a method that apply LP algorithm to image for speech recognition is suggested, using both speech and image information for recogniton of korean numeral speech. The input speech signal is pre-emphasized with parameter value 0.95, analyzed for B th LP coefficients using Hamming window, autocorrelation and Levinson-Durbin algorithm. Also, a gray image signal is analyzed for 2-dimensional LP coefficients using autocorrelation and Levinson-Durbin algorithm like speech. These parameters are used for input parameters of neural network using back-propagation algorithm. The recognition experiment was carried out at each noise level, three numeral speechs, '3','5', and '9' were enhanced. Thus, in case of recognizing speech with 2-dimensional LP parameters, it results in a high recognition rate, a low parameter size, and a simple algorithm with no additional feature extraction algorithm.

  • PDF

A Design and Implementation of MINI-PACS Employing the DICOM Converter on Web Environment (웹 상에서 DICOM 변환기를 이용한 MINI-PACS 설계 및 구현)

  • Ji, Youn-Sang;Rhee, Kang-Hyeon;Chung, Il-Yong;Lee, Sung-Joo
    • Journal of the Institute of Electronics Engineers of Korea CI
    • /
    • v.38 no.4
    • /
    • pp.39-49
    • /
    • 2001
  • Application of information system to hospital would bring innovative improvement on efficiency of business management and provide high quality services toward patients as well as the retrenchment of operating funds. PACS(Picture Archiving and Communication System) including X-ray film that manages the medical image information effectively, has drawn considerable attention to essential structural elements to the sophisticated information system for hospital. PACS system should be connected to the network after making a form of standard medical image file from different style of image information obtained from various medical instruments. In this paper, to solve this problem, we construct Mini-PACS that converts the form of Non-DICOM file to the form of standard file by designing the DICOM converter. This system is designed to be managed under Web environment. Comparing with the existed Mini-PACSs, consisting of the client and server module, our system is designed and implemented with integration of these functions in order to be strongly combine strongly between system.

  • PDF

The Usability Evaluation of Application that is Developed the Dynamic Kidney Phantom System in Nuclear Medicine

  • Kim, Jae-Hyun;Lee, Juyoung;Park, Hoon-Hee
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.16 no.2
    • /
    • pp.15-24
    • /
    • 2014
  • Currently commercially available phantom can reproduce and evaluate only a static situation, the study is incomplete research on phantom and system which is can confirmed functional situation in the kidney by time through dynamic phantom and blood flow velocity, various difference according to the amount of radioactive. Therefore, through this study, it has produced the dynamic kidney phantom to reproduce images through the dynamic flow of the kidney, it desires to evaluate the usefulness of nuclear medicine imaging. The production of the kidney phantom was fabricated based on the normal adult kidney, in order to reproduce the dynamic situation based on the fabricated kidney phantom, in this study it was applied the volume pump that can adjust the speed of blood flow, so it can be integrated continuously radioactive isotopes in the kidney by using 99mTc-pertechnate. Used the radioactive isotope was supplied through the two pump. It was confirmed the changes according to the infusion rate, radioactive isotopes and the different injection speeds on the left and right, analysis of the acquired images was done by drawn five times ROI in order to check the reproducibility of each on the front and rear of the kidney and bladder. Depending on the speed of injection, radioisotope was a lot of integrated and emissions up when adjusting the pressure of the pump as 30 stroke, it was the least integrated and emissions up when adjusting as 40 stroke. The integration of the left & right kidney was not reached in the amount of the highest when adjusting as 10 stroke. In the changes according to the amount of the radioactive isotope, 0.6 mCi(22.2 MBq), 0.8 mCi (29.6 MBq)was showed up similar tendency but, in the result of the injection 0.8 mCi, it was showed up counts close to double of 0.6 mCi. In the result of the differently injection speed of the left & right kidney, as a result of different conditions that injection speed was 20 stroke through left kidney phantom, the injection speed was 30 stroke through right kidney phantom, it was enough difference in the resulting image can be easily distinguished with the naked eye. Through this study, the results showed that the dynamic kidney phantom system is able to similarly reproduce renogram in the actual clinical. Especially, the depicted over time for the flow to be excreted through the kidney into the bladder was adequately reproduce, it is expected to be utilized as basic data to check the quality of the dynamic images. In addition, it is considered to help in the field of functional imaging and quality control.

  • PDF

Development of Dynamic Kidney Phantom System and its Evaluation of Usability of Application in Nuclear Medicine (핵의학 동적 신장팬텀시스템 개발 적용의 유용성 평가)

  • Park, Hoon-Hee;Lee, Juyoung;Kim, Sang-Wook;Lyu, Kwang Yeul;Jin, Gye Hwan
    • Journal of radiological science and technology
    • /
    • v.36 no.1
    • /
    • pp.49-55
    • /
    • 2013
  • Currently, commercially available phantom can reproduce and evaluate only a static situation, the study is incomplete research on phantom and system which is can confirmed functional situation in the kidney by time through dynamic phantom and blood flow velocity, various difference according to the amount of radioactive. Therefore, through this study, it has produced the dynamic kidney phantom to reproduce images through the dynamic flow of the kidney, it desires to evaluate the usefulness of nuclear medicine imaging. The production of the kidney phantom was fabricated based on the normal adult kidney, in order to reproduce the dynamic situation based on the fabricated kidney phantom, in this study, it was applied the volume pump that can adjust the speed of blood flow, so it can be integrated continuously radioactive isotopes in the kidney by using $^{99m}Tc$-pertechnate. Used the radioactive isotope was supplied through the two pump. It was confirmed the changes according to the infusion rate, radioactive isotopes and the different injection speeds on the left and right, analysis of the acquired images was done by drawn five times ROI in order to check the reproducibility of each on the front and rear of the kidney and bladder. Depending on the speed of injection, radioisotope was a lot of integrated and emissions up when adjusting the pressure of the pump as 30 stroke, it was the least integrated and emissions up when adjusting as 40 stroke. The integration of the left & right kidney was not reached in the amount of the highest when adjusting as 10 stroke. In the changes according to the amount of the radioactive isotope, 0.6 mCi(22.2 MBq), 0.8 mCi (29.6 MBq)was showed up similar tendency but, in the result of the different injection 0.8 mCi, it was showed up counts close to double of 0.6 mCi. In the result of the differently injection speed of the left & right kidney, as a result of different conditions that injection speed was 20 stroke through left kidney phantom, the injection speed was 30 stroke through right kidney phantom, it was enough difference in the resulting image can be easily distinguished with the naked eye. Through this study, the results showed that the dynamic kidney phantom system is able to similarly reproduce renogram in the actual clinical practice. Especially, the depicted over time for the flow to be excreted through the kidney into the bladder was adequately reproduce, it is expected to be utilized as basic data to check the quality of the dynamic images. In addition, it is considered to help in the field of functional imaging and quality control.