• 제목/요약/키워드: Image Enhancement

검색결과 1,424건 처리시간 0.031초

Cerebral Aspergillosis with Multiple Enhancing Nodules in the Right Cerebral Hemisphere in the Immune-Competent Patient

  • Lee, Gwang-Jun;Jung, Tae-Young;Choi, Seong-Min;Jung, Min-Young
    • Journal of Korean Neurosurgical Society
    • /
    • 제53권5호
    • /
    • pp.312-315
    • /
    • 2013
  • Aspergillosis in the central nervous system (CNS) is a very rare disease in immune-competent patients. There was a case of a healthy man without a history of immune-compromised disease who had invasive aspergillosis with unusual radiologic findings. A 48-year-old healthy man with diabetes mellitus, presented with complaints of blurred vision that persisted for one month. Brain magnetic resonance imaging (MRI) showed multiple nodular enhancing lesions on the right cerebral hemisphere. The diffusion image appeared in a high-signal intensity in these areas. Cerebrospinal fluid examination did not show any infection signs. An open biopsy was done and intraoperative findings showed grayish inflammatory and necrotic tissue without a definitive mass lesion. The pathologic result was a brain abscess caused by fungal infection, morphologically aspergillus. Antifungal agents (Amphotericin B, Ambisome and Voriconazole) were used for treatment for 3 months. The visual symptoms improved. There was no recurrence or abscess pocket, but the remaining focal enhanced lesions were visible in the right temporal and occipital area at a one year follow-up MRI. This immune-competent patient showed multiple enhancing CNS aspergillosis in the cerebral hemisphere, which had a good outcome with antifungal agents.

인쇄 속도 향상과 화질 개선을 위한 잉크젯 프린터 헤드의 액적 분사 신호 타이밍 제어 (A Jet Strobe Signal Timing Control of Ink Jet Printer Head for Enhancement of Printing Speed and Quality)

  • 조영완
    • 한국정보통신학회논문지
    • /
    • 제15권8호
    • /
    • pp.1727-1734
    • /
    • 2011
  • 본 논문에서는 잉크젯 프린터의 고품질 인쇄 및 인쇄 속도 향상을 위하여 헤드 노즐로부터 분사된 잉크 액적의 위치 제어 정밀도를 향상할 수 있는 방법을 제안한다. 샤프트를 따라 이동하고 있는 캐리지에 탑재된 잉크젯 프린터 헤드의 노즐로부터 분사 신호에 동기되어 분사된 액적의 운동 방정식을 수립하고 이로부터 액적이 용지에 도달하는 궤적을 모델링하여 탄착지점을 예측함으로써 분사 액적을 원하는 지점에 정확하게 탄착시키도록 액적 분사 신호의 타이밍을 제어하는 방법을 제안한다. 캐리지의 위치 신호와의 단순 동기에 기반을 둔 기존의 분사 제어 방법에 비해 본 논문에서 제안하는 방법은 이동하는 캐리지의 속도를 고려하여 분사 타이밍을 보상하므로 캐리지의 속도 변동에 대해서도 보다 정확한 위치 제어가 가능하여 고품질 인쇄를 구현할 수 있을 뿐만 아니라 방향 전환을 위한 가감속 구간에서도 프린팅을 가능하게 하므로 동일한 인쇄 영역에 대해서 캐리지의 이동 경로가 짧아져 인쇄 속도를 향상시킬 수 있다.

라이트필드 초해상도와 블러 제거의 동시 수행을 위한 적대적 신경망 모델 (Adversarial Framework for Joint Light Field Super-resolution and Deblurring)

  • 조나단 사무엘;백형선;박인규
    • 방송공학회논문지
    • /
    • 제25권5호
    • /
    • pp.672-684
    • /
    • 2020
  • 시차 기반 영상처리에 대한 연구들이 증가함에 따라 저해상도 및 모션 블러된 라이트필드 영상을 복원하는 연구는 필수적이 되었다. 이러한 기법들은 라이트필드 영상 향상 과정으로 알려져 있으나 두 개 이상의 문제를 동시에 해결하는 기존의 연구는 거의 존재하지 않는다. 본 논문에서는 라이트필드 공간 영역 초해상도 복원과 모션 블러 제거를 동시 수행하는 프레임워크를 제안한다. 특히, 저해상도 및 6-DOF 모션 블러된 라이트필드 데이터셋으로 훈련하는 간단한 네트워크를 생성한다. 또한 성능을 향상하기 위해 생성적 적대 신경망의 지역 영역 최적화 기법을 제안하였다. 제안한 프레임워크는 정량적, 정성적 측정을 통해 평가하고 기존의 state-of-the-art 기법들과 비교하여 우수한 성능을 나타냄을 보인다.

적응적 휘도 감소를 이용한 OLED 패널의 저전력 디스플레이 방법 및 하드웨어 구현 (Hardware Implementation of Low-power Display Method for OLED Panel using Adaptive Luminance Decreasing)

  • 조호상;최대성;서인석;강봉순
    • 한국정보통신학회논문지
    • /
    • 제17권7호
    • /
    • pp.1702-1708
    • /
    • 2013
  • OLED(Organic Light-Emitting Diode)는 LCD와 달리 자체발광 특성 때문에 흰색을 표현할 때에는 R,G,B 소자가 모두 발광하여야 하므로 전력소비가 상대적으로 커지게 되는 문제점이 있다. 본 논문은 OLED 패널을 사용한 기기의 저전력 디스플레이 방법 및 하드웨어 구현에 관한 것이다. 입력 이미지의 휘도 정보를 기반으로 하여 실시간으로 화소 별 휘도 변환 값을 생성하여 적응적 휘도 조절 방법과 색도 축소 알고리즘의 기본 개념을 사용하여 새로운 색상보정 알고리즘을 사용하여 OLED 패널의 저전력 디스플레이 방법을 제안한다. 기존의 방법과 비교함으로써 제안한 방법의 성능을 확인한 결과 최대 48.43%의 전류 감소를 확인하였다. 최종적으로 제안된 알고리즘은 Verilog HDL로 하드웨어를 구현하였으며, OpenCV와 Window 프로그램을 사용하여 소프트웨어적으로 알고리즘을 검증하였다.

2차원 리샘플링에 기반한 광선추적법의 속도 향상 기법 (Speed Enhancement Technique for Ray Casting using 2D Resampling)

  • 이래경;임인성
    • 한국정보과학회논문지:시스템및이론
    • /
    • 제27권8호
    • /
    • pp.691-700
    • /
    • 2000
  • 볼륨 데이타에 대한 팔진트리와 같은 계층 자료구조를 사용하는 광선 추적법은 모든 광선이 계층구조를 순회하는 것으로 인한 중복된 계산을 포함하고 있으며, 좋은 화질의 영상을 얻기 위한 3차원 보간으로 인하여 많은 계산 비용을 요구한다. 본 논문은 볼륨 데이타의 계층구조에 대한 중복된 방문을 피하고, 오직 한 번만 계층구조를 방문하면서 효과적으로 광선의 리샘플링 지점을 결정하여 색상과 투병도를 구하는 볼륨 렌더링 알고리듬을 제안한다. 이 방법은 물체 순서로 광선 추적법을 수행하면서, 각 복셀 주위에서의 리샘플링 지점을 점진적으로 찾아가면서 각 슬라이스 상에서의 2차원 보간에 기반을 둔 리샘플링을 수행한다. 또한 물체 순서 렌더링에서는 조기 광선 종결과 같은 최적화 기법을 구현하기 힘든데, 영상공간에서의 동적 자료구조를 이용하여 이를 효과적으로 해결하였다 본 논문이 제안한 방법은 구현하기 쉽고 속도 향상을 위하여 추가적으로 요구되는 메모리가 매우 적기 때문에 광선 추적법과 쉬어 와핑 방법 사이의 성능 차이를 메워주는 효과적인 방법으로 사용될 수 있을 것이다.

  • PDF

비글견의 간 CT 혈관조영상에서의 Iopamidol과 Iopromide, Iohexol 조명제의 비교실험 (A Comparison of Iopamidol with Iopromide and Iohexol Contrast Media in Hepatic CT Angiography in Beagle Dogs)

  • 정유철;임창윤;김경민;이성옥;정주현;장진화;오선경;송경진;윤정희;최민철
    • 한국임상수의학회지
    • /
    • 제23권2호
    • /
    • pp.129-132
    • /
    • 2006
  • The purpose of this paper was to compare the clinical efficacy of iopamidol and iopromide, iohexol nonionic contrast media in terms of their image quality in Beagle dogs with hepatic CT angiography and their application in veterinary clinics. With 9 Beagle dogs, contrast media of iopamidol (pamiray-$300^(R)$) and iopromide (ultravist-$300^(R)$, iohexol (omnipaque-$300^(R)$) were induced intravenously (600 mg I/kg, BW) and CT angiography was done under general anesthesia. CT scan included scout, pre-contrast and cine examinations. During CT angiography, peak HU (Hounsfield unit) and peak time were examined on each site (ROI; region of interest) of the aorta, caudal vena cava, potral vein and liver parenchyma. Any side effects were also examined. After experiments, it was found that there were no significant changes of HU and maximal enhancing time of each ROIs of aorta, caudal vena cava, portal vein and liver parenchyma between these contrast media. And any side effects were not noted. So it is concluded that iopamidol has similiar contrast enhancement like as iopromide and iohexol in hepatic angiography and and it is thought to be useful for evaluation of the abdominal organs by CT scan in veterinary clinics.

멀티캐스트 화상회의를 위한 3-D 음향시스템 설계 (Design of a Three Dimensional Audio System for Multicast Conferencing)

  • 김영오;고대식
    • 한국통신학회논문지
    • /
    • 제25권1B호
    • /
    • pp.71-76
    • /
    • 2000
  • 다수의 참여자가 존재하는 멀티미디어 화상회의 시스템에서, 참여자의 얼굴은 화상을 통하여 쉽게 구별할 수 있지만, 음성의 경우는 모든 참여자의 음성이 1차원적으로 처리되기 때문에 참여자의 구분이 어렵고 공간적인 실감을 느끼지 못한다. 본 논문에서는 HRTF(Head Realted Transfer Function: 머리전달 함수)와 거리감 재생 기법을 이용한 3-D 음향재현 시스템을 구현하고, 멀티캐스트 화상회의 시스템의 적절한 화자 배치를 연구분석하였다. 고도각과 수평각을 이용한 청취실험결과, 수평각이 고도각에 비하여 양호한 방향감 구별 인지도를 보였으며, 특히 4명의 참여자가 존재하는 화상회의 시스템의 경우 $10^{\circ}$, 90$^{\circ}$, 270$^{\circ}$, 350$^{\circ}$의 HRTF를 이용한 공간배치가 효율적인 것을 확인하였다. 끝으로 5인 이상의 참여자가 존재하는 경우와 현실감의 개선을 위하여 거리감이 이용될 수 있음을 제안한다.

  • PDF

의료영상의 화질개선을 위한 프랙탈 영상 부호화 (Fractal Image Coding for Improve the Quality of Medical Images)

  • 박재홍;박철우;양원석
    • 한국방사선학회논문지
    • /
    • 제8권1호
    • /
    • pp.19-26
    • /
    • 2014
  • 본 논문에서는 프랙탈 부호화시 변환식의 계수를 찾는 과정에서 블럭의 탐색영역을 줄이기 위해 탐색영역인 도메인 블럭의 특성을 화소의 밝기의 평균에 의한 클래스와 분산에 의한 클래스로 분류하여 리스트를 구성한 후 레인지 블럭과 같은 클래스를 가지는 도메인 블럭만 검색하도록 하면서 도메인 블록 탐색시 1차 허용 오차 한계값을 제어하여 리스트 탐색시 RMS값에 일정 허용오차 이내의 값을 가지면 리스트를 끝까지 탐색하지 않고 변환값을 결정하도록 하여 부호화 시간을 향상시켰다. 또한 퀴드트리 분할법으로 레인지 블럭의 크기를 가변시켜 변환($w_i$)의 수를 줄임으로서 압축효율을 높이고 도메인 레인지 블럭의 크기에 따라 탐색 영역의 탐색 밀도와 허용오차를 변화시켰을 때 화질 개선 여부를 검토하였다. 제안된 방법으로 부호화한 결과 부호화 시간은 허용오차의 범위에 따라 향상되며 압축효과는 높아 졌고 PSNR값은 다소 떨어졌으나 거의 무시할 수 있을 정도의 변화가 있었다.

뇌종양 확산강조영상에서 High B-value의 유용성 평가 (Usefulness of the High B-value DWI in Brain Tumors)

  • 김진태;변재후;박용성;이래곤;황선광
    • 대한디지털의료영상학회논문지
    • /
    • 제17권1호
    • /
    • pp.33-41
    • /
    • 2015
  • This study attempts to examine the clinical usefulness of High b-value DWI (diffusion weighted imaging) for brain tumors with an edema. Subjects were seven patients selected from 65 patients who received an MRI scan for suspected encephalopathy and confirmed diagnosis at our hospital from February to July 2015 (male: 7, average age : 66 years old). As test equipment, 3.0T MR System (ACHIEVA Release, Philips, Best, The Netherlands) and 8Channel SENSE Head Coill were used. DWI checks on the use of the variable TR 5460ms, TE 132ms, Slice Thickness 4mm, gap 1mm, Slice number 29 is, 3D T1WI is TR 8.4ms, TE 3.9ms, matrix size $240{\times}240$, Slice can set 180 piecesIt was. b value of 0, 1,000, 2,000 s/mm2 with DWI acquisition and 3D T1WI enhancement five minutes after the Slice Thickness 3mm, gap 0mm to reconstruct the upper face axis (MPR TRA CE) was. As for the experiment, in b-value 1,000 and 2,000 images, SNR and the lesion at the lesion site and CNR in the normal site opposite to the lesion are measured. WW(window width) and WL(window level) are made equal in MRICro software, and the volume of the lesion is measured from each of b-value and MPR TRA CE image. Using SPSS ver. 1.8.0.0 Mann Whitney-test was analyzed for SNR and CNR, while Kruskal-Wallis test was analyzed for volume.

  • PDF

DCE 3D Breast MRI 검사 시 30 sec 이내에 혈류 역학적 정보에 대한 연구 : Experienced Reports (A study on Hemo-Dynamic information Within 30 seconds in DCE 3D Breast MRI : Experienced Reports)

  • 구은회
    • 대한디지털의료영상학회논문지
    • /
    • 제16권1호
    • /
    • pp.27-33
    • /
    • 2014
  • The purpose of this study evaluated the hemo-dynamic information within 30 seconds clinically in 3D breast MRI. From January to March 2014, A total of 40 people were examined at 1.5 Tesla(Philips, Medical System, Achieva, The Netherlands) MRI equipments using 16 channel SENSE breast coil. The imaging parameters on vibrant are fellow as: $TR/TE/FA^{\circ}$/Matrix size/Slice thickness/Slab($5ms/2ms/10^{\circ}/180{\times}139{\times}2mm/80$). This study used a Gadovist and injected it with injection speed of 4 ml /sec by auto injector with 15 ml saline flushing. Firstly, for the delay time study, it divided three different delay time from immediately, 20 seconds, and 30 seconds. In quantitative analysis, the ROI signal intensities of tumor and surrounding tissues were measured retrospectively. In qualitative analysis, the image quality was scored from 1 to 5 point by one experienced radiological technologists as a visual test. The significance level of each delay time was evaluated with a one-way ANOVA(p<0.05). In the visual test, score levels on 30 seconds delay time was a little bit higher than others(p<0.05). The signal intensity of the tumor were $1445{\pm}360$, $1410{\pm}320$, $1510{\pm}415$ on immediately, 20 seconds, and 30 seconds and score levels were $4.18{\pm}0.85$, $3.54{\pm}0.94$, $4.45{\pm}0.74$(p<0.05). The data on immediate images showed better results than that others(p<0.05). Conclusively, Although it has been high scored in 30sec delay time for visual test in order to avoid failure in 20second, 30seconds delay time after contrast media administration, we recommend that the DCE 3D breast MRI commence immediately.

  • PDF