• Title/Summary/Keyword: Image Diagnosis

Search Result 1,396, Processing Time 0.032 seconds

Image Quality Evaluation according to X-ray Source Arrangement Type and the Number of Projections in a s-IGDT System (s-IGDT 시스템의 X-선원 배열 형태 및 투영상 개수에 따른 영상 화질 평가에 관한 연구)

  • Lee, Dahye;Nam, KiBok;Lee, Seungwan
    • Journal of radiological science and technology
    • /
    • v.45 no.2
    • /
    • pp.117-125
    • /
    • 2022
  • Although stationary inverse-geometry digital tomosynthesis (s-IGDT) is able to reduce motion artifacts, image acquisition time and radiation dose, the image quality of the s-IGDT is degraded due to the truncations arisen in projections. Therefore, the effects of geometric and image acquisition conditions in the s-IGDT should be analyzed for improving the image quality and clinical applicability of the s-IGDT system. In this study, the s-IGDT images were obtained with the various X-ray source arrangement types and the various number of projections. The resolution and noise characteristics of the obtained s-IGDT images were evaluated, and the characteristics were compared with those of the conventional DT images. The s-IGDT system using linear X-ray source arrangement and 40 projections maximized the image characteristics of resolution and noise, and the corresponding system was superior to the conventional DT system in terms of image resolution. In conclusion, we expect that the s-IGDT system can be used for providing medical images in diagnosis.

Development of Dental Medical Image Processing SW using Open Source Library (오픈 소스를 이용한 치과 의료영상처리 SW 개발)

  • Jongjin, Park
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.23 no.1
    • /
    • pp.59-64
    • /
    • 2023
  • With the recent development of IT technology, medical image processing technology is also widely used in the dental field, and the treatment effect is enhanced by using 3D data such as CT. In this paper, open source libraries such as ITK and VTK are introduced to develop dental medical image processing software, and how to use them to develop dental medical image processing software centering on 3D CBCT. In ITK, basic algorithms for medical image processing are implemented, so the image processing pipeline can be quickly implemented, and the desired algorithm can be easily implemented as a filter by the developer. The developed algorithm is linked with VTK to implement the visualization function. The developed SW can be used for dental diagnosis and treatment that overcomes the limitations of 2D images..

Evaluation on the Usefulness of Ultrasound Image Speckle Reduction Using Total Variation Denoising (TVD) Method in Laplacian Pyramid (라플라시안 피라미드 기반 총변동 잡음제거 기법을 이용한 초음파 영상 스펙클 제거 유용성 평가)

  • Moon, J.H.;Choi, D.H.;Lee, S.Y.;Tae, Ki-Sik
    • Journal of Biomedical Engineering Research
    • /
    • v.37 no.4
    • /
    • pp.140-146
    • /
    • 2016
  • The ultrasound imaging in medical diagnosis has become a popular modality because of its safe, noninvasive, portable, relatively inexpensive, and provides a real-time image formation. However, usefulness of ultrasound imaging is at times limited due to the presence of signal-dependent noise like as speckle. Therefore, noise reduction is very important, as various types of noise generated limits the effectiveness of medical image diagnosis. This paper introduces a speckle noise reduce algorithm using total variation denoising (TVD) in Laplacian pyramid. With this method, speckle is removed by TVD of bandpass ultrasound images in Laplacian pyramid domain. For TVD in each pyramid layer, a ${\lambda}$ is selected by trial-and-error method. The visual comparison of despeckled 'in vivo' ultrasound images from pancreas shows that the proposed method could effectively preserve edges and detailed structures while thoroughly suppressing speckle. For a Simulated B-mode image, contrast-to-noise-ratio (CNR) and signal-to-noise-ratio (SNR) were obtained like 4.65 dB and 14.11 dB, respectively. The results show that the proposed method can conduct better than some of the existing methods in terms of the CNR and the SNR.

Mobile Computed Tomography : Three Year Clinical Experience in Korea

  • Jeon, Jin Sue;Lee, Sang Hyung;Son, Young-Je;Yang, Hee-Jin;Chung, Young Seob;Jung, Hee-Won
    • Journal of Korean Neurosurgical Society
    • /
    • v.53 no.1
    • /
    • pp.39-42
    • /
    • 2013
  • Objective : Obtaining real-time image is essential for neurosurgeons to minimize invasion of normal brain tissue and to prompt diagnosis of intracranial event. The aim of this study was to report our three-year experience with a mobile computed tomography (mCT) for intraoperative and bedside scanning. Methods : A total of 357 mCT (297 patients) scans from January 2009 to December 2011 in single institution were reviewed. After excluding postoperative routine follow-up, 202 mCT were included for analysis. Their medical records such as diagnosis, clinical application, impact on decision making, times, image quality and radiologic findings were assessed. Results : Two-hundred-two mCT scans were performed in the operation room (n=192, 95%) or intensive care unit (ICU) (n=10, 5%). Regarding intraoperative images, extent of resection of tumor (n=55, 27.2%), degree of hematoma removal (n=42, 20.8%), confirmation of catheter placement (n=91, 45.0%) and monitoring unexpected complications (n=4, 2.0%) were evaluated. A total of 14 additional procedures were introduced after confirmation of residual tumor (n=7, 50%), hematoma (n=2, 14.3%), malpositioned catheter (n=3, 21.4%) and newly developed intracranial events (n=2, 14.3%). Every image was obtained within 15 minutes and image quality was sufficient for interpretation. Conclusion : mCT is feasible for prompt intraoperative and ICU monitoring with enhanced diagnostic certainty, safety and efficiency.

Comparison of the observer reliability of cranial anatomic landmarks based on cephalometric radiograph and three-dimensional computed tomography scans (삼차원 전산화단층촬영사진과 측모두부 방사선규격사진의 계측자에 따른 계측오차에 대한 비교분석)

  • Kim, Jae-Young;Lee, Dong-Keun;Lee, Sang-Han
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.36 no.4
    • /
    • pp.262-269
    • /
    • 2010
  • Introduction: Accurate diagnosis and treatment planning are very important for orthognathic surgery. A small error in diagnosis can cause postoperative functional and esthetic problems. Pre-existing 2-dimensional (D) chephalogram analysis has a high likelihood of error due to its intrinsic and extrinsic problems. A cephalogram can also be inaccurate due to the limited anatomic points, superimposition of the image, and the considerable time and effort required. Recently, an improvement in technology and popularization of computed tomography (CT) provides patients with 3-D computer based cephalometric analysis, which complements traditional analysis in many ways. However, the results are affected by the experience and the subject of the investigator. Materials and Methods: The effects of the sources human error in 2-D cephalogram analysis and 3-D computerized tomography cephalometric analysis were compared using Simplant CMF program. From 2008 Jan to 2009 June, patients who had undergone CT, cephalo AP, lat were investigated. Results: 1. In the 3 D and 2 D images, 10 out of 93 variables (10.4%) and 11 out 44 variables (25%), respectively, showed a significant difference. 2. Landmarks that showed a significant difference in the 2 D image were the points frequently superimposed anatomically. 3. Go Po Orb landmarks, which showed a significant difference in the 3 D images, were found to be the artificial points for analysis in the 2 D image, and in the current definition, these points cannot be used for reproducibility in the 3 D image. Conclusion: Generally, 3-D CT images provide more precise identification of the traditional cephalometric landmark. Greater variability of certain landmarks in the mediolateral direction is probably related to the inadequate definition of the landmarks in the third dimension.

Correlation Analysis between HIVD of L-spine MRI and Digital Infrared Thermal Image (DITI) on the Patients of LBP Who Visit Korean Medicine Hospital (한방병원에 요통, 하지방사통으로 내원한 환자 236명에서 MRI상 추간판 탈출증과 적외선 체열 검사(DITI)와의 연관성 분석)

  • Kim, Gil-Hwan;Kwon, Ok-Jun;Joo, Young-Kuk;Song, Seung-Bae;Kim, Doo-Ri;Choi, Young-Jun;Shin, Soo-Ji
    • Journal of Korean Medicine Rehabilitation
    • /
    • v.27 no.3
    • /
    • pp.107-115
    • /
    • 2017
  • Objectives This study is planned to classify correlation between HIVD of L-spine MRI and Digital Infrared Thermal Image (DITI). Methods We measured the temperature of both leg whose 120 men and 116 women patients with lumbar pain in Bucheon Jaseng Korean Medicine Hospital. And We use Magnetic Resonance Imaging (MRI) for classifying the patients who has lumbar intervertebral disc or not. Results 1) There was no statistical relation between difference of both leg's temperature and gender (p>0.05). 2) There was meaningful statistical relation between difference of both leg's temperature and age (p<0.05). 3) There was meaningful statistical relation between direction of HIVD of L-spine and direction of temperature reduction. 4) There was meaningful statistical relation between the severity of HIVD of L5/S1 and degree of temperature reduction. But there was no statistical relation between the severity of HIVD of L3/4, L4/5 and degree of temperature reduction. Conclusions We can use Digital Infrared thermal image (DITI) on low back pain patients for diagnosis. But we should not use DITI alone. DITI has limit in diagnosis.

The Characteristics of UV Generation and Aging Materials in According to Surface Discharge (연면방전에 의한 폴리머애자의 자외선 발생과 열화특성)

  • Shong, Kil-Mok;Bang, Sun-Bae;Kim, Chong-Min;Kim, Young-Seok;Jung, Jin-Su
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.9
    • /
    • pp.1606-1611
    • /
    • 2008
  • Recently, The diagnosis techniques of electric facilities are developed on live line. This paper describes the discharge characteristics of polymer insulator(EPDM A type). Keeping the facilities in good working order, the goal of this paper will provide the information to enable user to easily judge conditions of facilities on the spot. The performance of polymer insulator is assessed from the KS C IEC 60270 and CEA LWIWG-01(96)(Tracking Wheel Test). As the results, UV generation patterns of polymer insulator grow like a jellyfish shape follow the ramping voltage. Discharging UVs are detected at about 31.25% of breakdown voltage. Just then, dimension of UV image is about $0.84cm^{2}$. The dimension of max. UV image is about $297.4cm^{2}$ at $160kV(V_{bd})$. The position of UV generation due to surface discharge of polymer insulator is the center of insulator in the early, then moved the ground side and the last, UV image moved through the junction part of source side. Surface of aged polymer insulator is cracked and faded due to arc. UV absorption spectrum of polymer insulator are appeared the C-H bond of scissoring vib. at $1014cm^{-1}$ and C=O bond of recombination structure. Also, recombined UV absorption peak such as C-H, N-H, and O-H is detected at the $3321cm^{-1}$. Through the paper, there are inspection data which are the relations between surface discharge of polymer insulator and UV detecting image.

Convergence of the Image Evaluation by BI-RADS Classification in Accordance with Algorithms in DR Mammography (디지털 유방촬영술에서 BI-RADS의 구분에 따른 알고리즘별 영상의 융복합적 평가)

  • Lee, Mi-Hwa
    • Journal of Digital Convergence
    • /
    • v.13 no.9
    • /
    • pp.489-495
    • /
    • 2015
  • Image availability evaluated by the degree of agreement and sensitive using the process improve visualization according to the Algorithm modification in Image Post-Processing. Reliability measured by the Breast Imaging Reporting and Data System. 172 patients visit same period divided by BI-RADS, category five stages, and contents of breast parenchyma into Calcification, Nodule and Mass. Evaluated the TE/PV image reliability, visualization sensitive, agreement of diagnosis. Convergence analysis was an in various fields. According to the result of this research, PV has higher sensitive and accuracy about lesions than TE visual and there is a difference insensitive by contents of breast parenchyma. Therefore, practical use of Algorithm Modification(Tissue Equalization: TE, Premium View: PV) is expected to improve more accurate, useful diagnosis, which has not been easy until now.

Extraction of Transverse Abdominis Muscle form Ultrasonographic Images (초음파 영상에서 복횡근 근육 추출)

  • Kim, Kwang-Baek
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.22 no.3
    • /
    • pp.341-346
    • /
    • 2012
  • In rehabilitation where ultrasonographic diagnosis is not popular, it could be subjective by medical expert's experience. Thus, it is necessary to develop an objective automative procedure in ultrasonic image analysis. A disadvantage of existing automative analytic procedure in musculoskeletal system is to designate an incorrect muscle area when the figure of fascia is vague. In this study, we propose a new procedure to extract more accurate muscle area in abdomen ultrasonic image for that purpose. After removing unnecessary noise from input image, we apply End-in Search algorithm to enhance the contrast between fascia and muscle area. Then after extracting initial muscle area by Up-Down search, we trace the fascia area with a mask based on morphological and directional information. By this tracing of mask movements, we can emphasize the fascia area to extract more accurate muscle area in result. This new procedure is proven to be more effective than existing methods in experiment using convex ultrasound images that are used in real world rehabilitation diagnosis.

The Research on Compression Image Quality of Full Field Digital Mammography on PACS Environment (PACS환경에서 Full Field Digital Mammography 영상의 압축 화질평가에 관한 연구)

  • Jeong, Jaeho;Kim, Eunsoo
    • Journal of the Korean Society of Radiology
    • /
    • v.8 no.4
    • /
    • pp.147-153
    • /
    • 2014
  • We tried to assessment about characteristics of image through quantitative evaluation method and qualitative evaluation method in Full Field Digital Mammography. It satisfied an approval standard of ten score regardless of compression ratio measuring detection score after compressing and appling an algorithm of JPEG2000 orJPEG compression targeting ACR accreditation phantom. Also, it was apparent that when we selected and compressed the image of real fine lesion and measured a change of diagnosis ability magnifing over 50 percent after compressing over 20:1 ratio, it had a strong influence on diagnosis ability. We realized that the difference between the original image according to compression ratio measuring a quantitative evaluation which is PSNR,RMSE,MAE and SSIM was relatively allowable.