• Title/Summary/Keyword: Image Acquisition

Search Result 1,309, Processing Time 0.026 seconds

The Study of Acquisition Signal Distortion due to Edge Effect in Direct Digital Radiography System

  • Cho, Jin-Wook;Choi, Jang-Yong;Mun, Chi-Woona;Lee, Hyung-Won;Nam, Sang-Hee
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2001.10a
    • /
    • pp.179.1-179
    • /
    • 2001
  • Successive image contrast enhancement was used to direct digital radiography system. This system was accurately required acquisition signal in each pixel. But, applied high electric field in a-Se thin film for x-ray conversion layer was caused to acquisition signal distortion, then bring low image contrast. The purpose of this study was to reduce the signal distortion, carried out different electrode size.

  • PDF

DEVELOPMENT OF ROI PROCESSING SYSTEM USING QUICK LOOK IMAGE

  • Ahn, Sang-Il;Kim, Tae-Hoon;Kim, Tae-Young;Koo, In-Hoi
    • Proceedings of the KSRS Conference
    • /
    • 2007.10a
    • /
    • pp.526-529
    • /
    • 2007
  • Due to its inherent feature of high-resolution satellite, there is strong need in some specific area to minimize the processing time required to get a standard image on hand from downlink signal acquisition. However, in general image processing system, it takes considerable time to get image data up to certain level from raw data acquisition because the huge amount of data is dealt sequentially as input data. This paper introduces the high-speed image processing system which generates the image data only for the area selected by user. To achieve the high speed performance, this system includes Quick Look Image display function with sampling, ROI selection function, Image Line Index function, and Distributed processing function. The developed RPS was applied to KOMPSAT-2 320Mbps downlink channel and its effectiveness was successfully demonstrated. This feature to provide the image product very quickly is expected to promote the application of high resolution satellite image.

  • PDF

A study on a development of a measurement technique for diffusion of oil spill in the ocean (디지털 화상처리에 의한 해양유출기름확산 계측기법개발에 관한 연구)

  • 이중우;김기철;강신영;도덕희
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 1998.10a
    • /
    • pp.211-221
    • /
    • 1998
  • A digital image processing technique which is able to get the velocity vector distribution of a surface of the spilled oil in the ocean without contacting the flow itself. This technique is based upon the PIV(Particle Imaging Velocimetry) technique and its system mainly consists of a high sensitive camera, a CCD camera, an image grabber, and a host computer in which an image processing algorithm is adopted for velocity vector acquisition. For the acquisition of the advective velocity vector of floating matters on the ocean, a new multi-frame tracking algorithm is proposed, and for the acquisition of the diffusion velocity vector distribution of the spilt oil onto the water surface, a high sensitive gray-level cross-correlation algorithm is proposed.

  • PDF

The Automatic Detection of Inner Boundary on EBCT Images for Airway (기도에 대한 EBCT 영상에서의 내벽 윤곽선 자동검출)

  • 김명남;조진호
    • Journal of Korea Multimedia Society
    • /
    • v.6 no.6
    • /
    • pp.991-999
    • /
    • 2003
  • In this paper, we proposed image acquisition techniques that can reflect anatomical airway information lot breath change by EBCT Also, we proposed new method to detect automatically boundary of inner airway for acquired slice images using this image acquisition technology. We confirmed that new method detects boundary of inner airway effectively through computer simulation that apply image data about each slice position of airway. And, we could see change for cross section area of inner airway by time change. Therefore, we think that proposed method can utilize on quantitative analysis in clinical field.

  • PDF

Performance Improvement Technique of Long-range Target Information Acquisition for Airborne IR Camera

  • Yang, Hyun-Jin
    • Journal of the Korea Society of Computer and Information
    • /
    • v.22 no.7
    • /
    • pp.39-45
    • /
    • 2017
  • In this paper, we propose three compensation methods to solve problems in high-resolution airborne infrared camera and to improve long-range target information acquisition performance. First, image motion and temporal noise reduction technique which is caused by atmospheric turbulence. Second, thermal blurring image correction technique by imperfect performance of NUC(Non Uniformity Correction) or raising the internal temperature of the camera. Finally, DRC(Dynamic Range Compression) and flicker removing technique of 14bits HDR(High Dynamic Range) infrared image. Through this study, we designed techniques to improve the acquisition performance of long-range target information of high-resolution airborne infrared camera, and compared and analyzed the performance improvement result with implemented images.

Implementation of Image Monitoring system using High Speed Camera for Overhead Contact Wire (고속 카메라를 이용한 전차선 형상 검측 시스템 구현)

  • Cho, Hyeon-Young;Kwon, Sam-Young;Lee, Ki-Won;Park, Hyun-June;Na, Hae-Kyoung;Ko, Byeong-Hun;Park, Young
    • Proceedings of the KSR Conference
    • /
    • 2006.11b
    • /
    • pp.1483-1487
    • /
    • 2006
  • In electric railway, image monitoring using high speed camera provides reliable, timely information of wear and geometry status, important in taking decisions for overhead contact wire maintenance. The contribution of this research is the development of a simple real-time monitoring system for use in measurement subsystem of contact wire and geometry of overhead contact wire in electric railway. The system has been consists of a high speed CMOS camera with resolution $1024{\times}1280$ pixels, line type laser source and PC-based image acquisition system with PCI Express slot. Vision acquisition software have been used in application programming interface for image acquisition, display, and storage with a frequency of sampling of 500 acquisitions per second.

  • PDF

A Study on a Development of a Measurement Technique for Diffusion of Oil Spill in the Ocean (디지털 화상처리에 의한 해양유출기름확산 계측기법개발에 관한 연구)

  • 이중우;강신영;도덕희;김기철
    • Journal of Korean Port Research
    • /
    • v.12 no.2
    • /
    • pp.291-302
    • /
    • 1998
  • A digital image processing technique which is able to be used for getting the velocity vector distribution of a surface of the spilt oil in the ocean without contacting the flow itself. This technique is based upon the PIV(Particle Imaging Velocimetry) technique and its system mainly consists of a high sensitive camera, a CCD camera, an image grabber, and a host computer in which an image processing algorithm is adopted for velocity vector acquisition. For the acquisition of the advective velocity vector of floating matters on the ocean, a new multi-frame tracking algorithm is proposed, and for the acquisition of the diffusion velocity vector distribution of the spilt oil onto the water surface, a high sensitive gray-level cross-correlation algorithm is proposed.

  • PDF

Effect of Metals used in Orthopedic on Magnetic Resonance Imaging I (정형보철용 금속이 자기공명영상에 미치는 영향 I)

  • Kim, Hyeong-Gyun;Choi, Seong-Dae
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.11 no.4
    • /
    • pp.46-50
    • /
    • 2012
  • Stainless steel and titanium used for orthopedic prosthetic metal, magnetic resonance imaging was measured quantitatively the extent of distortion. Based on reading tests at varying metal magnetic resonance imaging (MRI) were investigated. To two image acquisition conditions for having three metal bodies mutually quantitative it compared analyzed the image of cross direction and the image of lengthwise. As for the distortion of the magnetic resonance image, as for the distortion of image it became small in the order of Clip, Strainless and Titanium. In addition, with T1WI and T2WI which are image acquisition condition T2WI the distortion of image became small. As for the distortion of the image by the metal, you could see the distortion of image in elliptical shape, the metal a bigger image distortion appeared in many parts. If clinical doctor has the condition of the same operation, use the Titanium material, it can, raising the diagnostic value of magnetic resonance image inspection after the operating from Stainless.

Data Acquisition System Design and Implementation of Cargo System Using a Large Output X-ray (고출력 X-선을 이용한 대형화물 검색시스템의 Data Acquisition System 설계 및 구현)

  • Yoo, Sun-Won;Kim, In-Su;Kim, Bong-Su;Yi, Yun
    • Proceedings of the IEEK Conference
    • /
    • 2002.06e
    • /
    • pp.223-226
    • /
    • 2002
  • Data Acquisition System of Cargo System using a large output X-ray in harbors is usually composed of Detector, Analog Board, Digital Board, Master Board, Backplane Board and Image Construction System. In this paper we have made an image of material in container-box with Data Acquisition System and studied mainly a configuration method and principle to each part of Data acquisition system.

  • PDF

A Study on characteristics of Image Information Acquisition of Indoor Space (실내공간의 이미지 정보획득 특성에 관한 연구)

  • Kim, Jong-Ha;Choi, Gae-Young
    • Korean Institute of Interior Design Journal
    • /
    • v.20 no.1
    • /
    • pp.138-145
    • /
    • 2011
  • This study analyzed the time to understand the space and the contents of information to be memorized in the indoor space. Understanding the space and examining the memory will not only provide the basic data on which visual activities occur in user's perceiving the designed space but also expand the activity range of interior designer. The summary of the study results is as follows: First, with respect to gender difference, the results showed that males grasped the space in a relatively shorter time. Females showed more concentrated distribution range than males. Second, as for the proper time by accumulative sum across time, the results showed that it increased continuously until V time zone(120~150 seconds), it decreased rapidly after the V zone, which indicated that the proper gazing time for the indoor space as the target of this study is less than 150 seconds(effective gazing time). Third, in terms of efficiency of information acquisition, the results suggested that "60~90 seconds" are the effective time for acquiring the greatest amount of information. Fourth, regarding the information acquisition method, males were approximately 4.1%~0.1% lower in the evaluation through phrase and image. The evaluation of subjects through phrase than image was connected to more accurate information acquisition.