• Title/Summary/Keyword: Illuminance measurement

Search Result 82, Processing Time 0.025 seconds

Automation of Roadway Lighting Illuminance Measurement

  • BAO, Jieyi;HU, Xiaoqiang;JIANG, Yi;LI, Shuo
    • International conference on construction engineering and project management
    • /
    • 2022.06a
    • /
    • pp.705-711
    • /
    • 2022
  • Roadway lighting is an integral element of a highway system. Luminaires on roadways provide viewing conditions for drivers and pedestrians during nighttime in order to improve safety. It is time-consuming and labor-intensive to manually measure roadway illuminance at predetermined spots with a handheld illuminance meter. To improve the efficiency of illuminance measurement, a remote-control electrical cart and a drone were utilized to carry an illuminance meter for the measurements. The measurements were performed on the marked grid points along the pavement. To measure the illuminance manually, one person measures illuminance at each grid point with the handheld meter and another person records the illuminance value. To measure the illuminance with the remote-control cart, the illuminance meter is attached to the cart and it measures illuminance values continuously as the cart moves along the grid lines. With the drone, the meter records the illuminance continuously as the drone carries the meter and flies along the grid line. Because the drone can fly at different heights, the measurements can be done at different altitudes. The illuminance measurements using the cart and the drone are described in detail and compared with manual measurements in this paper. It is shown through this study that automated measurements can greatly improve the efficiency of roadway illuminance data measurements.

  • PDF

The Method of Improvement by Illuminance Measurement of the CT Scan Room in a General Hospital Radiology (종합병원 영상의학과 CT 검사실의 조도 측정에 의한 향상 방안)

  • Kweon, Dae-Cheol;Yang, Sung-Hwan;Kang, Young-Sig
    • Journal of the Korean Institute of Plant Engineering
    • /
    • v.23 no.4
    • /
    • pp.51-56
    • /
    • 2018
  • Computed tomography (CT) scan room in the department of radiology is very necessary to maintain pleasant and proper illuminance to relieve fatigue and inconvenience because it affects the work environment to the radiologist. Accordingly, this paper describes the method for measurement of illuminance that exposed to an environmental elements in a CT scan room of the hospital. Therefore, the purpose of this paper is to propose an optimal environment of CT scan room based on the measurement of illuminance. In addition, the 5 point method by KS C7612 was applied to measure the illuminance with illuminometer (Unfors xi light probe) in the CT scan room. In result of this paper, minimum value and maximum value of illuminance in the CT scan room was measured 212.7 lux and 354.8 lux, respectively. The illuminance of CT scan room was lower than KS A 3011. Finally, the work environment in CT scan room should provide higher illuminance for the comfortable environment of radiologists and patients.

Validation of a Daylight Measurement System Using the CIE Guide of Recommended Practice of Daylight Measurement (CIE 권장가이드를 이용한 자연채광 기후요소 측정시스템의 유효성 검증)

  • Kong, Hyo Joo;Lee, Jong Soo;Kim, Gon;Yun, Geun Young;Kim, Jeong Tai
    • KIEAE Journal
    • /
    • v.10 no.6
    • /
    • pp.41-46
    • /
    • 2010
  • This study is to validate the K University daylight measurement system according to the CIE guide of recommended practice of daylight measurement. In this study global irradiance, illuminance, direct normal illuminance, diffuse irradiance, illuminance and vertical illuminances(North, West, South, East) were measured and compared in accordance with the CIE quality control test. Field monitoring was conducted from 1st August to 15th August 2010. Results for the CIE tests 1 to 4 showed an accuracy of 100%. This indicates that the K University daylight measurement system is reliable and the measurement data would be useful for further daylight researches.

Measurement and Computing Method of the Average Illuminance in Residential Areas (공동주택의 조도측정 및 평균조도 산출방법)

  • Joo, Keun-Tak;Choi, An-Seop
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.20 no.5
    • /
    • pp.1-8
    • /
    • 2006
  • The Five Point Method of KS and Four Point Method of IES are generally used to measure and compute the average illuminance in residential areas. Such methods of measurement should be used exactly according to the characteristics of the space and activities. Therefore, this study evaluated computation methods of the average illuminance in terms of comparing the measured values with simulated ones. The Five Point Method of KS is very closed to evaluate task illuminancefor appreciating activities at the center while the Four Point Method of IES is very closed to a concept of the average illuminance over the space excluding the possible maximum and minimum illuminance values.

Automatic measurement of a Isolux diagram (등조도 곡선의 자동화 측정)

  • 권영혜;장우진
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 1989.10a
    • /
    • pp.31-36
    • /
    • 1989
  • Low-cost and automated isolux diagram measurement system are investigated. The system is constructed with illuminance measurement array, analog multiplexer, A/D converter and 16-bit microcomputer. The experimental results show good agreement with the measured illuminance values. Decreasing the measure-spacing, the more accurate diagram can be obtained.

  • PDF

Hybrid Illumination System Design based on Illuminance Uniformity for Surface Inspection (표면 검사를 위한 조도 균제도 기반 하이브리드 조명계 설계)

  • Cho, Eun Deok;Kim, Gyung Bum
    • Journal of the Semiconductor & Display Technology
    • /
    • v.18 no.3
    • /
    • pp.60-65
    • /
    • 2019
  • In this paper, the hybrid illumination system for effectively detecting surface defects in steel plate with lowcontrast, non-uniformity and featureless is designed based on illuminance uniformity. First of all, characteristics of steel plate defects were considered and typical inspection illumination system is implemented. Optimum illumination parameters for uniformly illuminating an inspection area in the typical illumination system are selected based on the illuminance uniformity and illuminance distribution measurement. The illuminance uniformity and illuminance distribution are measured using an illuminometer based on the arduino. Through illuminance distribution analysis of the typical illumination, an hybrid illumination is designed by fusing bi-directional illumination and coaxial illumination. The hybrid illumination showed higher uniformity ratio and illuminance distribution than the typical illuminations. The hybrid illumination system showed the ability to uniformly illuminate the entire inspection region of steel plate surface.

Development of 2 Division Illuminance Measurement Mobile Systems (차량을 이용한 2분할 조도측정시스템의 개발)

  • Jo, Deok-Soo;Lee, Chang-Mo;Jung, Seung-Gyun;Seok, Doe-Il;Kim, Hoon
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.22 no.1
    • /
    • pp.1-6
    • /
    • 2008
  • It is important to grasp the accurate lighting level for appropriate maintenance of the road lighting equipment. It is developed 2 division illuminance measurement systems. This system has a small size and no need to block the way and achieves the speedy measurement and high accuracy data in automatically measurement. As a result, this system can save expense and time to measure roadway lighting.

An Analysis for the Night illuminance Affected on Light Environments and Weather Conditions (광환경과 기상조건에 따른 야간조도 영향 분석)

  • Lee, Jaewon;Park, Inchun;Choi, Cheolmin;Kim, Young-chul
    • Journal of the Korean Society for Aviation and Aeronautics
    • /
    • v.24 no.1
    • /
    • pp.25-32
    • /
    • 2016
  • This study deals with the light environments and weather conditions affecting to the night illuminance over the Korean peninsula. The experiment was executed to analyze the effects on the illuminance at separate sites(Gyeryong and Pilseung) considering the different light environments. The analysis was applied to illuminance measurement from the lightmeter, which was developed for the IYA(International Year of Astronomy) 2009, in order to observe the illuminance of areal networks. The weather observations, such as the cloud cover and visibility, were used to understand the quantitative influence of the illuminance to the selected sites. The results show that the illuminance measurements are significantly different from data of the operational illuminance prediction model which simply applies extinction effect for the illuminance. It shows that these differences are caused by the light environments and weather conditions for each site. Therefore, it can be confirmed that the night illuminance is the output of interaction with the characteristics of light for luminous sources.

A Study on the Illuminance Measurement and Improvement of Public Libraries in Daegu City (공공도서관 조도분석 및 개선방안 연구 - 대구지역을 중심으로 -)

  • Yoon, Hee-Yoon
    • Journal of Korean Library and Information Science Society
    • /
    • v.48 no.4
    • /
    • pp.1-20
    • /
    • 2017
  • The most important identity of public library is local public goods that guarantee access and use of knowledge and information of local residents. To justify this, the library must create an optimal lighting environment. Particularly, since the perception rate of information through vision is over 80%, it is necessary to secure proper illuminance. This study measured the illuminance level of public libraries in Daegu. Based on the results, this study suggested a desirable illuminance level for each space and proposed plans to secure and maintain proper illuminance(prospective revision of the KS A 3011, setting the illuminance range for each space of the local government, replacing the existing lighting fixtures with LED, enhance supervision of lighting management, establishment of basic principles for proper lighting and detailed plans for each space of the library, investigation and reflection on users' complaints and satisfaction, etc.)

The Actual State and Evaluation of Artificial Lighting on Coffee Houses Using Study Place around University (학습공간으로 이용되는 대학주변 커피전문점의 조명 실태 및 평가)

  • Choe, Sol-ji;Choi, Yoon-Jung
    • KIEAE Journal
    • /
    • v.11 no.6
    • /
    • pp.53-62
    • /
    • 2011
  • This study aimed at suggesting improvement of lighting environment of the coffee house using study place. To this end, a series of field investigation was conducted in four possible target coffee houses around university. The field measurement included measurement of general illuminance and tabletop illuminance, observing illumination condition, and status of artificial lighting. Also, on-site questionnaire survey was administrated to 80 users of field measurement targets about using characteristics of coffee house and user's subjective response on light environment. The results are summarized as follows: (1) According to questionnaire survey, most of users checked 'learning (study and reading)' in 'purpose of coffee house using', and 'slightly dark' was checked most in each subjective response (brightness on general space and on tabletop at daytime/night); (2) as results of measurements on general illuminance and on tabletop illuminance during daytime, only one coffee house was suitable for standard; (3) as results of measurements on illuminance during night, all target coffee houses were not met the standard; (4) as results of uniformity ratios, almost uniformities of general illuminance were not met the standard except one case. The common problems of lighting environment of coffee house were analyzed as lack of daylight illumination e.g. having low amount of sunshine from skylight, un-uniformity of insolation by floor plan and absence of window blind, and un-uniformity of artificial luminous intensity e.g. lack of the number or brightness of artificial lighting, using the indirect lighting, using only local lighting, and non-uniform arrangement of artificial lighting.