• 제목/요약/키워드: Ignition Cause

검색결과 142건 처리시간 0.02초

Mixer-type LPG차량에서 엔진역화에 의한 차량 파손에 관한 연구 (A Study on the Damage by Engine Backfire in the Mixer-type LPG Vehicles)

  • 전광수;최성은;진영욱;정진은
    • 대한안전경영과학회:학술대회논문집
    • /
    • 대한안전경영과학회 2009년도 추계학술대회
    • /
    • pp.223-229
    • /
    • 2009
  • The engine backfire leading to the damage to the intake system is observed in the mixer-type LPG engines. The hot spot flowing back into the intake manifold from the engine cylinder during the valve overlap period is known to give rise to the backfire. This backfire is known to be the main cause of the abrupt stop of the vehicle leading to the accidents on the streets. In this study, the cylinder pressure buildup at the later stage of combustion due to the prolonged burning is presumed to be the main cause of the backflow leading to the backfire. This is experimentally observed by creating the engine misfire using the ill-conditioned ignition systems.

  • PDF

화재 실험을 통한 에어컨 실내기의 화염확산에 관한 현상학적 연구 (A Phenomenological Study on the Flame Spread of Air Conditioner Indoor unit by Fire Tests)

  • 최승복;이승훈;최민기;최돈묵
    • 한국화재소방학회논문지
    • /
    • 제27권6호
    • /
    • pp.89-96
    • /
    • 2013
  • 본 연구의 목적은 연소 실험을 통하여 에어컨 실내기의 화염확산에 관한 형상을 관찰하여 화재원인 및 발화지점을 확인하기 위함이다. 본 실험은 화염이 주변으로부터 에어컨 상단에 옮겨 붙는다는 것을 가정하여 실내기 상단을 n-햅탄을 적신 천으로 착화시켰으며, 동일한 조건으로 2회의 반복실험을 하였다. 착화 후 559 s와 734 s 사이에 실내기와 연결된 냉매관이 파열되면서 내부에 충입되어 있던 냉매와 함께 윤활유가 커다란 폭음을 내며 고온 고압의 화염이 급격히 분출되었으며 연소 잔류물을 확인한 결과, 증발기 일부와 모터, 금속함 등을 제외한 대부분은 소실되었다. 에어컨 자체에서 발화되었을 경우와 외부 화염에 의해 소훼되었을 경우 배선의 합선흔적 위치는 유사하였다. 따라서 연소 잔류물의 형상만으로 발화원인과 지점을 특정 짖는 것은 불확실하다는 것을 확인하였다.

열분석 실험에 의한 화약류 폐기물의 화재원인분석에 관한 연구 (Study on the Fire Cause Analysis for Explosives Waste by Thermal Analysis Experiment)

  • Koh, Jae-Sun
    • 한국재난정보학회 논문집
    • /
    • 제14권1호
    • /
    • pp.89-100
    • /
    • 2018
  • 지정(특수)폐기물로 처리되어야 할 폭발성 폐기물이 일반폐기물 처리장에 잘못 반입되어 폐기물 처리과정에서 폭발사고로 이어졌을 때 많은 인명과 재산피해가 수반되므로 향후 폐기물 배출업체는 처리에 적합 가능한 처리시설로 폐기물을 처리하여야 한다. 본론에서 언급한 바와 같이 화약류 포장재 폐기물(고체부타디엔)의 착화재연실험에서 모두 발화위험성이 확인되었고, 작은 점화원에도 쉽게 착화되어 급속하고 폭발적으로 연소되는 형태를 나타냄을 알 수 있었다. 특히 폐기물처리장에서의 화약류 포장재에 의한 화재 폭발사고 사례와 같이 화약류 포장재 폐기물이 소각폐기물처리장에 대량으로 반입되어 유기화합물 폐기물과 혼재되어 있을 때는 상호 산화반응과 열분해 등으로 가연성, 산화성 가스가 발생되어 스파크 등 점화원에 의해 착화되며 순간적으로 폭발로 이어지는 개연성이 있음을 확인 할 수 있었다. 본연구가 화재현장에서의 현장 감식에 있어서 작은 참고자료가 되었으면 하는 바람과 과학적인 발화원인 판정으로 소방기관이 화재조사 전문기관으로서 대외적인 공신력을 인정받고 신뢰성 향상에 기여하는 계기가 되기를 기대한다.

타올에 흡착된 반건성유인 옥수수유의 자연발화에 대한 실험적 연구 (Experimental Study on the Spontaneous Ignition of Corn Oil Adsorbed on Towels)

  • 김경수;최유정;유삼열;정필훈;최재욱
    • 한국재난정보학회 논문집
    • /
    • 제18권3호
    • /
    • pp.574-580
    • /
    • 2022
  • 연구목적: 옥수수유는 반건성유로서 불건성유보다 이중결합의 수가 많고 산소와 결합하기 쉬우므로 자연발화의 조건이 충족되면 적은 양으로도 가연성 물질에 흡착될 경우에는 자연발화가 쉽게 발생된다. 또한 최근 자연발화의 원인 중 산화열에 의해 기름이 묻은 헝겊 등에 의한 사고가 늘어나고 있다. 그러므로 65℃에서 타올의 매수와 옥수수유의 양에 따른 자연발화의 특성을 파악하고자 한다. 연구방법: 실험온도를 65℃로 설정한 후 타올 한 장당 25ml, 50ml, 75ml에 해당하는 옥수수유를 분사시킨 후 시료의 중심 온도가 설정된 온도보다 상승하고, 타올이 연소로 인해 탈 경우에는 발화로 판정하였으며, 시료의 중심 온도가 설정된 온도와 유사할 경우에는 비발화로 판정하였다. 연구결과: 옥수수유를 타올 한 장 당 25ml씩 골고루 분포시킨 후 실험을 한 결과 타올이 5장 일 때는 비발화되었으며, 타올이 10장, 15장일 때는 발화되었다. 또한 옥수수유를 타올 한 장 당 50ml, 75ml씩 사용하여 실험한 결과 타올이 5장, 10장, 15장일 때 자연발화가 발생되었다. 결론: 옥수수유가 적은 양으로도 자연발화의 조건을 충족하면 화재가 발생할 수 있다.

산불영향에 따른 송전용 폴리머애자의 특성 (The Influence of Forest Fire on the Characteristics of Polymer Insulator for Transmission Lines)

  • 이동일;정용운;유근양;최인혁
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제54권3호
    • /
    • pp.127-131
    • /
    • 2005
  • Big fire such as mountain fire may cause the prevention of the functions of the overhead cables and insulators, which may affect the operation of the transmission lines. In the worst case, this kind of disaster may have a huge effect on the whole industry of a country. However, the study on the effect of the mountain fire on the transmission line is very rare. Therefore, in order to understand the effect of the mountain fire on the polymeric insulator for transmission lines, the author observed the deformation of the sheds of the polymeric insulators and the change of the discs of the porcelain insulators under fire, varying the ignition time using the artificial ignition testing equipment which simulates the mountain fire, and investigated the electrical and mechanical characteristics of the insulators after the ignition test. For the test, the miniature insulators made of polymeric material and porcelain have been utilized. As the result, the following conclusions were obtained. First, the porcelain insulator was degraded in electrical characteristics when the insulator was subjected to the fire for approximately 5 minutes; whereas, the polymeric insulator was not degraded though there were some damage on its sheds. Second, after 20 minute exposure to the fire, the polymeric insulator lost a lot of parts of sheds, but the electrical characteristics was lowered by around $20\%$, but the porcelain insulators were electrically degraded by more than $80\%$.

스타트모터 B단자 절연파괴 화재사례에 대한 실험적 연구 (A experimental Study on Insulation Breaking Fire Case of Starter Motor B Terminal)

  • 우승우;박정만;현병수;남정우;박우식;김진표;조영진;고재모;박남규
    • 한국안전학회지
    • /
    • 제34권5호
    • /
    • pp.55-62
    • /
    • 2019
  • In this paper, we introduce a case of a fire accident during parking of a large truck that is repeatedly occurring. The shape and location of the combustion and electrical singularity commonly found in other vehicle fire accidents could limit the starter motor as the ignition section. In addition, it was possible to confirm the electrical melting singularity that could act as a cause of ignition between the start motor B terminal and the start motor enclosure. By combining the above investigations and investigations, it was possible to estimate the electric fire expressed from insulation breaking of the starter motor B terminal, and by using the renewable starter motor comparison product mounted on the fire vehicle, an experiment was performed to reproduce the ignition process from the starter motor under specific conditions. So. It is hoped that this will raise awareness about vehicle fires, which can lead to large fires or casualties, share the risks of using starter motors for regeneration, and help in the rapid and accurate investigation of similar vehicle fires in the future.

수소기관의 이상점화에 의한 역화발생 (Backfire Occurrence by Abnormal Electric Discharge in Hydrogen Fueled Engine)

  • 김윤영;류태호;이종태
    • 한국수소및신에너지학회논문집
    • /
    • 제13권1호
    • /
    • pp.65-73
    • /
    • 2002
  • Because of low flame ion density in hydrogen-air mixture, many residual electric energy could be existed in the ignition system of hydrogen engine, If these residual energy discharged abnormally during intake stroke, it may be the cause of backfire occurrence which is serious problem in development of hydrogen fueled engine but unsolved in spite of many concerned research on it. In this study, the possibility of backfire occurrence by abnormal electric discharge and countermeasure of that were investigated by using the experimental single cylinder hydrogen fueled engine with two types of ignition system. The results show that abnormal electric discharge appeared in low load with low ion density and then results in back fire occurrence, It is also seen that countermeasure method installing larger earth resistance in high tension code is effective to control abnormal electric discharge.

유동층 건조설비에 있어서 분진의 정전기 위험성에 관한 실험적 연구 (Experimental Study on Electrostatic Hazards of Powder in Fluidized Bed)

  • 문균태;정재희;최광석
    • 한국안전학회지
    • /
    • 제25권4호
    • /
    • pp.19-24
    • /
    • 2010
  • A large amount of electrostatic charges is often generated on polymer powders in fluidized bed and thereby may lead to electrostatic problems. In this study, to evaluate electrostatic hazards of powder in fluidized bed, the electric field(E[v/m]) and the charge amount(q[c/g]) during fluidizing were monitored. We also investigated the Minimum Ignition Energy(MIE [J]) of sample powder used in fluidized bed with the Hartman vertical-tube apparatus. The batch-type fluidized bed system and 2kg as Polypropylene(PP) resin powders were used in the experiments. The following results were obtained: (1) Even when a safe margin of several times was considered, the values of E obtained with PP powder in this paper did not exceed 3 to 5kV/cm, at which an incendiary electrostatic discharge could occur. (2) the ave. q was -0.26${\mu}$C/g during fluidizing. This value was high enough to cause electrostatic agglomeration and adhesion. (3) the entrained PP powder in upper column due to fluidizing could be ignited by electrostatic discharges of 71mJ.

B-KNO3 점화제의 가속 노화 특성 연구 (A Study on Acceleration Aging Characteristics of B-KNO3 Igniter)

  • 백종규;류병태;권미라
    • Korean Chemical Engineering Research
    • /
    • 제52권2호
    • /
    • pp.166-174
    • /
    • 2014
  • 본 연구에서는 점화제로 사용되는 $B-KNO_3$의 가속노화 실험에 따른 특성변화를 고찰하였다. 점화제는 보관 방법이나 보관기간에 따라 점화 효율이 저하되는 경향이 있으며 안정된 사용을 위해서는 이에 대한 명확한 이해가 필요하다. 따라서 노화에 대한 원인 규명을 위해 가속화 시험 시편의 미세구조와 결정구조 및 열분석을 수행하였으며 점화 특성에 끼치는 영향성을 규명하고자 하였다. 산화제로 첨가된 $KNO_3$의 결정구조를 분석함으로써 노화에 끼치는 산화제 영향을 해석하였다. 결론적으로 산화제의 결정구조가 안정한 구조로 변화되었으며 활성화 에너지변화에 영향을 끼쳤다.

Zr과 ZrNi로 구성된 고체연료의 노화 연구 Part 2: 화학반응식 추출 및 성능모사 (Aging of Solid Fuels Composed of Zr and ZrNi Part 2: Kinetics Extraction for Full Simulation)

  • 한병헌;박윤식;;류재용;여재익
    • 한국추진공학회지
    • /
    • 제24권2호
    • /
    • pp.14-27
    • /
    • 2020
  • 본 연구는 점화제와 지연제에 대한 시차 주사 열량 측정법을 통하여 반응 속도식 및 발열량을 추출하여 노화에 따른 반응 특성을 분석하기 위한 정밀 수치계산을 수행하였다. 연소 실험을 수행하여 수분이 관여된 노화에서 점화제와 지연제에서 명확한 연소 중단을 확인하였다. 이 결과를 수치계산과 비교하여 노화가 점화제와 지연제 전반에 성능 감소 및 오작동 요인으로 작용됨을 확인하였다.