• Title/Summary/Keyword: Identical image

Search Result 198, Processing Time 0.023 seconds

Experimental Study on the Soot Formation Characteristics of Alkane-based Single Fuel Droplet (알케인계 단일 연료 액적의 Soot 생성 특성에 관한 실험적 연구)

  • Lim, Young Chan;Suh, Hyun Kyu
    • Journal of ILASS-Korea
    • /
    • v.22 no.2
    • /
    • pp.80-86
    • /
    • 2017
  • The soot formation characteristics of various alkane-based single fuel droplets were studied in this work. Also, This study was performed to provide the database of the soot behavior and formation of alkane-based single fuel droplet. The experimental conditions were set to 1.0 atm of ambient pressure ($P_{amb}$), 21% of oxygen concentration ($O_2$) and 79% of nitrogen concentration ($N_2$). Combustion and soot formation of single fuel droplet was visualized by visualization system with high speed camera. At the same time, ambient pressure, oxygen concentration and nitrogen concentration were maintained by ambient condition control system. Soot formation characteristics was analyzed and compared on the basis of intensity ratio ($I/I_0$) of background image. The results of toluene fuel droplet showed the largest soot generation. Soot volume fraction ($f_v$) was almost the same under the identical fuel types regardless of various initial droplet diameter ($d_0$) since thermophoretic flux was not much changed under the same ambient conditions.

The Visual Optical illusion effect study of Lip Make-up (입술 메이크업의 시각적 착시 효과 연구)

  • Ha, Sun-Ok;Cho, Koh-Mi
    • Journal of Fashion Business
    • /
    • v.12 no.1
    • /
    • pp.164-172
    • /
    • 2008
  • A face is the place where individuals can first give their images visually. This chapter presents how 'Visual optical illusion' works in applying makeup and how to differentiate the direction, location and shape of Lip in the aspect of physiognomy. For this study, employed were five types of face shape produced by Photoshop program. The best-matched facial shape was examined through a questionnaire research after applying the optical illusion of Lip to the five types of face shape. The results were revealed to be identical to ones presented in make-up teaching materials. In conclusion, it was found that well-matched shape and size of Lip could make some changes in the facial impression, changing the face shape into oval shape. The facial line can be modified and supplemented by reshaping such facial parts as the Lip, producing well-balanced facial shape. Consequently, make-up was proved to be one of the methods which can be used to create social and psychological effect which can make a favorable facial impression and individuality, natural impression and image making depending on different purposes, taking advantage of optical illusion effect.

Three-Dimensional Metal Complex Host with Alternating Arrangement of the Occupied and Vacant Channels. The Crystal Structure of Cd(NH₂CH(CH₃)CH₂NH₂)Ni(CN)₄· 0.25G (G=$CH_3C_6H_5, p-(CH_3)_2C_6H_4$)

  • 박기민;이욱;Toschitake Iwamoto
    • Bulletin of the Korean Chemical Society
    • /
    • v.17 no.10
    • /
    • pp.919-924
    • /
    • 1996
  • Crystal structure of two inclusion compounds Cd(pn)Ni(CN)4·0.25G (G=toluene and p-xylene, pn=1,2-diaminopropane) have been determined from single-crystal X-ray diffraction data; toluene clathrate: monoclinic P21/n, a=13.838(6), b=26.893(5), c= 7.543(5) Å, γ=90.92(3)°, Z=4, R=0.0616; p-xylene clathrate: monoclinic P21/n, a=13.895(2), b=26.900(3), c=7.613(1) Å, γ=91.06(1)°, Z=4, R=0.0486. The host structures determined for toluene- and pxylene-guest clathrates are substantially identical to the U-type structures observed for the straight chain aliphatic-guest clathrates. However, the alternating arrangement of occupied channels with the guest molecules and vacant channels appears in the host structure. The non-centrosymmetric toluene molecules are distributed about the inversion center to give an image like p-xylene molecule. The guests, toluene and p-xylene, prefer the U-type channel, favoring the interaction between the π-electrons of the aromatic ring and the pn-amino groups to hold the aromatic ring vertical to the cyanometallate meshes.

Adaptive Block Watermarking Based on JPEG2000 DWT (JPEG2000 DWT에 기반한 적응형 블록 워터마킹 구현)

  • Lim, Se-Yoon;Choi, Jun-Rim
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.44 no.11
    • /
    • pp.101-108
    • /
    • 2007
  • In this paper, we propose and verify an adaptive block watermarking algorithm based on JPEG2000 DWT, which determines watermarking for the original image by two scaling factors in order to overcome image degradation and blocking problem at the edge. Adaptive block watermarking algorithm uses 2 scaling factors, one is calculated by the ratio of present block average to the next block average, and the other is calculated by the ratio of total LL subband average to each block average. Signals of adaptive block watermark are obtained from an original image by itself and the strength of watermark is automatically controlled by image characters. Instead of conventional methods using identical intensity of a watermark, the proposed method uses adaptive watermark with different intensity controlled by each block. Thus, an adaptive block watermark improves the visuality of images by 4$\sim$14dB and it is robust against attacks such as filtering, JPEG2000 compression, resizing and cropping. Also we implemented the algorithm in ASIC using Hynix 0.25${\mu}m$ CMOS technology to integrate it in JPEG2000 codec chip.

Understanding on MR Perfusion Imaging Using First Pass Technique in Moyamoya Diseases (Moyamoya 질환에서 1차 통과기법을 이용한 자기공명관류영상의 이해)

  • Ryu, Young-Hwan;Goo, Eun-Hoe;Jung, Jae-Eun;Dong, Kyung-Rae;Choi, Sung-Hyun;Lee, Jae-Seung
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.12 no.1
    • /
    • pp.27-31
    • /
    • 2010
  • The purpose of this study was to investigated the usefulness of MR perfusion image comparing with SPECT image. A total of pediatric 30 patients(average age : 7.8) with Moyamoya disease were performed MR Perfusion with 32 channel body coil at 3T from March 01, 2010 to June 10, 2010. The MRI sequences and parameters were as followed : gradient Echo-planar imaging(EPI), TR/TE : 2000ms/50ms, FA : $90^{\circ}$, FOV : $240{\times}240$, Matrix : $128{\times}128$, Thickness : 5mm, Gap : 1.5mm. Images were obtained contrast agent administrated at a rate of 1mL/sec after scan start 10s with a total of slice 1000 images(50 phase/1 slice). It was measured with visual color image and digitize data using MRDx software(IDL version 6.2) and also, it was compared of measurement with values of normal and abnormal ratio to analyze hemodynamic change, and a comparison between perfusion MR with technique using Warm Color at SPECT examination. On MR perfusion examination, the color images from abnormal region to the red collar with rCBV(relative cerebral blood volume) and rCBF(relative cerebral blood flow) caused by increase cerebral blood flow with brain vascular occlusion in surrounding collateral circulation advancement, the blood speed relatively was depicted slowly with blue in MTT(Mean Transit Time) and TTP(Time to Peak) images. The region which was visible abnormally from MR perfusion examination visually were detected as comparison with the same SPECT examination region, would be able to confirm the identical results in MMD(Moyamoya disease)judgments. Hymo-dynamic change in MR perfusion examination produced by increase and delay cerebral blood flow. This change with digitize data and being color imaging makes enable to distinguish between normal and abnormal area. Relatively, MR perfusion examination compared with SPECT examination could bring an excellent image with spatial resolution without radiation expose.

  • PDF

The Factors Associated with Weight Control Experiences among Adolescents - Based on Self-esteem, Body-cathexis, Attitudes toward the Body, Anthropometric Characteristics and Perceptions of Body Shape - (일부 청소년의 체중조절과 관련된 요인에 관한 연구 -자아존중감, 신체만족도 및 중요도, 신체적 특성과 체형에 대한 인식을 중심으로-)

  • 허은실;강현진;이경혜
    • Korean Journal of Community Nutrition
    • /
    • v.8 no.5
    • /
    • pp.658-666
    • /
    • 2003
  • This study was carried out to investigate among adolescents (total=729) the relationship between their self-esteem, body-cathexis, their attitudes toward the importance of their bodies, their anthropometric characteristics, their perceptions of their body shapes and their experiences with weight control. The results are summarized as follows: The mean values for self-esteem and body-cathexis were generally low, but these values were significantly higher among boys than girls (p<0.01-0.001). However the mean values for their attitudes toward the importance of their bodies were relatively high and were significantly higher among girls than boys (p<0.01). The mean values for Percent Ideal Body Weight (PIBW) and Body Mass Index (BMI) were normal and no significant differences between the genders were observed. The distribution of the PIBW and the BMI values showed a higher rate for normal weights among the girls and a higher rate for underweightedness and obesity among the boys (p<0.01). With regard to their perception of their body image, among the boys, their current figures were almost identical with their idea of an ideal figure, but among the girls, their idea of an ideal figure was thinner than their current figure. The girls were more dissatisfied with their own body image than the boys (p<0.001). Fifty-four percent of the subjects had previous weight control experience, and the girls had significantly more experience than the boys (p<0.001). Their main reason for practising weight control was to lose weight (65.3%) Those who had more weight control experience had lower satisfaction with their body shapes, higher PIBW, higher BMIs or currently had fatter figures. Their standard image of their figures was influenced by TV (40.3%) and friends (36.9%). There was a weakly positive correlation between their self-esteem and their satisfaction with their body shapes, and a weakly negative correlation between their satisfaction with their body shapes and their attitudes toward the importance of their bodies. These results suggest the necessity for an educational program for adolescents as to foster a positive body image. Such a program should consider psychological factors such as self-esteem, satisfaction with body shape and attitudes toward the importance of the body.

A Study on the Pixel-Paralled Image Processing System for Image Smoothing (영상 평활화를 위한 화소-병렬 영상처리 시스템에 관한 연구)

  • Kim, Hyun-Gi;Yi, Cheon-Hee
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.39 no.11
    • /
    • pp.24-32
    • /
    • 2002
  • In this paper we implemented various image processing filtering using the format converter. This design method is based on realized the large processor-per-pixel array by integrated circuit technology. These two types of integrated structure are can be classify associative parallel processor and parallel process DRAM(or SRAM) cell. Layout pitch of one-bit-wide logic is identical memory cell pitch to array high density PEs in integrate structure. This format converter design has control path implementation efficiently, and can be utilize the high technology without complicated controller hardware. Sequence of array instruction are generated by host computer before process start, and instructions are saved on unit controller. Host computer is executed the pixel-parallel operation starting at saved instructions after processing start. As a result, we obtained three result that 1)simple smoothing suppresses higher spatial frequencies, reducing noise but also blurring edges, 2) a smoothing and segmentation process reduces noise while preserving sharp edges, and 3) median filtering, like smoothing and segmentation, may be applied to reduce image noise. Median filtering eliminates spikes while maintaining sharp edges and preserving monotonic variations in pixel values.

Content-Based Image Retrieval of Chest CT with Convolutional Neural Network for Diffuse Interstitial Lung Disease: Performance Assessment in Three Major Idiopathic Interstitial Pneumonias

  • Hye Jeon Hwang;Joon Beom Seo;Sang Min Lee;Eun Young Kim;Beomhee Park;Hyun-Jin Bae;Namkug Kim
    • Korean Journal of Radiology
    • /
    • v.22 no.2
    • /
    • pp.281-290
    • /
    • 2021
  • Objective: To assess the performance of content-based image retrieval (CBIR) of chest CT for diffuse interstitial lung disease (DILD). Materials and Methods: The database was comprised by 246 pairs of chest CTs (initial and follow-up CTs within two years) from 246 patients with usual interstitial pneumonia (UIP, n = 100), nonspecific interstitial pneumonia (NSIP, n = 101), and cryptogenic organic pneumonia (COP, n = 45). Sixty cases (30-UIP, 20-NSIP, and 10-COP) were selected as the queries. The CBIR retrieved five similar CTs as a query from the database by comparing six image patterns (honeycombing, reticular opacity, emphysema, ground-glass opacity, consolidation and normal lung) of DILD, which were automatically quantified and classified by a convolutional neural network. We assessed the rates of retrieving the same pairs of query CTs, and the number of CTs with the same disease class as query CTs in top 1-5 retrievals. Chest radiologists evaluated the similarity between retrieved CTs and queries using a 5-scale grading system (5-almost identical; 4-same disease; 3-likelihood of same disease is half; 2-likely different; and 1-different disease). Results: The rate of retrieving the same pairs of query CTs in top 1 retrieval was 61.7% (37/60) and in top 1-5 retrievals was 81.7% (49/60). The CBIR retrieved the same pairs of query CTs more in UIP compared to NSIP and COP (p = 0.008 and 0.002). On average, it retrieved 4.17 of five similar CTs from the same disease class. Radiologists rated 71.3% to 73.0% of the retrieved CTs with a similarity score of 4 or 5. Conclusion: The proposed CBIR system showed good performance for retrieving chest CTs showing similar patterns for DILD.

Adaptive Image Rescaling for Weakly Contrast-Enhanced Lesions in Dedicated Breast CT: A Phantom Study (약하게 조영증강된 병변의 유방 전용 CT 영상의 대조도 개선을 위한 적응적 영상 재조정 방법: 팬텀 연구)

  • Bitbyeol Kim;Ho Kyung Kim;Jinsung Kim;Yongkan Ki;Ji Hyeon Joo;Hosang Jeon;Dahl Park;Wontaek Kim;Jiho Nam;Dong Hyeon Kim
    • Journal of the Korean Society of Radiology
    • /
    • v.82 no.6
    • /
    • pp.1477-1492
    • /
    • 2021
  • Purpose Dedicated breast CT is an emerging volumetric X-ray imaging modality for diagnosis that does not require any painful breast compression. To improve the detection rate of weakly enhanced lesions, an adaptive image rescaling (AIR) technique was proposed. Materials and Methods Two disks containing five identical holes and five holes of different diameters were scanned using 60/100 kVp to obtain single-energy CT (SECT), dual-energy CT (DECT), and AIR images. A piece of pork was also scanned as a subclinical trial. The image quality was evaluated using image contrast and contrast-to-noise ratio (CNR). The difference of imaging performances was confirmed using student's t test. Results Total mean image contrast of AIR (0.70) reached 74.5% of that of DECT (0.94) and was higher than that of SECT (0.22) by 318.2%. Total mean CNR of AIR (5.08) was 35.5% of that of SECT (14.30) and was higher than that of DECT (2.28) by 222.8%. A similar trend was observed in the subclinical study. Conclusion The results demonstrated superior image contrast of AIR over SECT, and its higher overall image quality compared to DECT with half the exposure. Therefore, AIR seems to have the potential to improve the detectability of lesions with dedicated breast CT.

Change of Dose Exposure and Improvement of Image Quality by Additional Filtration in Mammography (유방촬영용장치 부가필터에 따른 선량변화 및 화질개선)

  • Cho, Woo Il;Kim, Young Kuen;Lee, Gil Dong
    • Journal of Radiation Protection and Research
    • /
    • v.38 no.2
    • /
    • pp.78-90
    • /
    • 2013
  • Recently, the interest on exposure to radiation is rising. The radiation exposure of mammography is higher in absorbed dose than of X-ray, therefore unnecessary exposure needs to be reduced, and higher image quality is needed. Generally, ray quality of the radiation imaging is an important factor that determines image quality and the amount of ray exposure, and they are affected by tube voltage and added filter. The X-ray energy that is exposed from mammography device is generally a continuous spectrum, which includes low energy that has minute influence on the image quality, and high energy that hinders contrast on image. Currently, molybdenum (Mo) and rhodium (Rh) are the most used added filters for mammography device, and they are used differently according to the energy region of X-ray. This study aims to find out the degree of reduction in exposure dose according to the thickness of aluminum (Al), and to study the changes in image quality and dose when the added filter plates that are made with niobium (Nb) or zirconium (Zr) are used, other than molybdenum (Mo) and rhodium (Rh), the two most used added filters that have similar atomic number and K-absorption regions as Nb and Zr. In this study, single-added filters of molybdenum (Mo), niobium (Nb), and zirconium (Zr) are used, and in some cases, Aluminum (Al) is combined with the single filters. In this case, image quality is considered to be improved depending on the type of added filters, and by using Aluminum (Al) filter together with the others, unnecessary X-ray of low energy would be absorbed, therefore the dose is expected to decrease without any influence when the concentration level becomes identical.