• Title/Summary/Keyword: Id3

Search Result 974, Processing Time 0.037 seconds

Evaluation of success criteria for temporomandibular joint arthrocentesis

  • Yilmaz, Onur;Candirli, Celal;Balaban, Emre;Demirkol, Mehmet
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.45 no.1
    • /
    • pp.15-20
    • /
    • 2019
  • Objectives: The aim of this study was to use four sets of success criteria to evaluate the outcomes of arthrocentesis treatment with hyaluronic acid injection in patients with internal derangement (ID) of the temporomandibular joint (TMJ). Materials and Methods: The study included 40 patients diagnosed with unilateral Wilkes stage III TMJ dysfunction. Clinical parameters, including maximum mouth opening (MMO) and pain during function, were evaluated preoperatively, 6 months, and 1 year after TMJ arthrocentesis. Outcomes were assessed and compared using four sets of success criteria from the following: the American Association of Oral and Maxillofacial Surgeons (AAOMS; MMO ${\geq}35mm$ and visual analogue scale [VAS] score ${\leq}3$), Murakami et al.'s criteria (MMO >38 mm and VAS score <2), Emshoff and Rudisch criteria (MMO ${\geq}35mm$ and >50% pain reduction), and patient self-reports (self-evaluation of treatment as successful or unsuccessful). Results: Significant improvements in MMO and pain reduction during function were observed between the preoperative period and 6 months and 1 year postoperatively (P<0.01). The success rates of treatment determined using AAOMS (52.5%), Emshoff and Rudisch criteria (57.5%), and self-reported patient criteria (40.0%) were similar. Application of the Murakami et al. criteria reported the lowest success rate (12.5%). Conclusion: The AAOMS and Emshoff and Rudisch criteria are consistent with patient expectations and can be used to assess treatment efficacy.

Investigation of Structural Change of DLC Coating during Frictional Wear by Raman Spectroscopy (라만 분광법을 활용한 마모 중 DLC 코팅의 구조적 변화 조사)

  • Kim, Song-Hee;Jang, Jae Cheol
    • Journal of the Korean institute of surface engineering
    • /
    • v.52 no.1
    • /
    • pp.16-22
    • /
    • 2019
  • The structural change of DLC coatings during long-term wear test and dicing test under the low loading condition was investigated. DLC coatings were applied for the precision injection molds of a modified SNCM steel for the extension of life and the micro-diamond blades for the high cutting efficiency and the increase in life. A ball-on-disc wear tests in the mold steel and a dicing tests in the micro-diamond blades were conducted to understand degradation of DLC coatings. The degradation of DLC coatings for the injection mold steel and the micro-diamond blades during the wear and dicing tests were studied with Raman Spectroscopy. Raman peaks were divided two bands(D band and G band) to study the degradation process of DLC structure. By the wear test, polished condition of wear marks were observed to be maintained until 10 hrs of wear test period is given, but small striation marks appeared in 20 hours wear test. It was observed that $I_D/I_G$ ratios changed as the degradation of DLC coatings is proceeded during the wear tests and the dicing tests. It is suggested that the change in $I_D/I_G$ value possibly reflected from the composition of $sp^2$ and $sp^3$ bondings in DLC layers relevant to the change in mechanical and physical property.

A Dilute-and-Shoot LC-MS/MS Method for Screening of 43 Cardiovascular Drugs in Human Urine

  • Pham, Thuy-Vy;Lee, Gunhee;Mai, Xuan-Lan;Le, Thi-Anh-Tuyet;Nguyen, Thi Ngoc Van;Hong, Jongki;Kim, Kyeong Ho
    • Mass Spectrometry Letters
    • /
    • v.12 no.1
    • /
    • pp.1-10
    • /
    • 2021
  • A simple, specific, and economical LC-MS/MS method was investigated for the screening of 43 prescribed antihypertensive and related drugs in human urine. The urine samples were simply prepared by diluting and mixing with internal standard before directly introduced to the LC-MS/MS system, which is fast, straightforward, and cost-effective. Fractional factorial, Box-Behnken, and I-optimal design were applied to screen and optimize the mass spectrometric and chromatographic factors. The analysis was carried out on a triple quadrupole mass spectrometer system utilizing multiple reaction monitoring with positive and negative electrospray ionization method. Chromatographic separation was performed on a Thermo Scientific Accucore RP-MS column (50 × 3.0 mm ID., 2.6 ㎛) using two separate gradient elution programs established with the same mobile phases. Chromatographic separation was performed within 12 min. The optimal method was validated based on FDA guideline. The results indicated that the assay was specific, reproducible, and sensitive with the limit of detection from 0.1 to 50.0 ㎍/L. The method was linear for all analytes with coefficient of determination ranging from 0.9870 to 0.9981. The intra-assay precision was from 1.44 to 19.87% and the inter-assay precision was between 2.69 and 18.54% with the recovery rate ranges from 84.54 to 119.78% for all drugs measured. All analytes in urine samples were stable for 24 h at 25℃, and for 2 weeks at -60℃. The developed method improves on currently existing methods by including larger number of cardiovascular medications and better sensitivity of 12 analytes.

PARKING GUIDE AND MANAGEMENT SYSTEM WITH RFID AND WIRELESS SENSOR NETWORK

  • Gue Hun Kim;Seung Yong Lee;Joong Hyun Choi;Youngmi Kwon
    • International conference on construction engineering and project management
    • /
    • 2009.05a
    • /
    • pp.1278-1282
    • /
    • 2009
  • In apartment type of housing, if resident's vehicle is registered in central control office and RFID TAG is issued, identification can be recognized from the time of entrance into parking lot and intelligent parking guide system can be activated based on the residents' profile. Parking Guide System leads a vehicle to the available parking space which is closest to the entrance gate of the vehicle's owner. And when residents forget where they parked their cars, they can query to the Parking Guide and Management System and get responses about the location. For the correct operation of this system, it is necessary to find out where the residents' cars have parked in real time and which lot is available for parking of other cars. RFID is very fancy solution for this system. RFID reader gathers the ID information in RFID TAGs in parked cars and updates the DB up to date. But, when non-residents' cars are parked inside apartment, RFID reader cannot identify them nor know the exact empty/occupied status of parking spaces because they don't react to RFID reader's query. So for the exact detection of empty/occupied status, we suggest the combined use of ultrasonic sensors and RFID. We designed a tree topology with intermediate data aggregators. The depth of tree is normally more than 3 from root (central office) to leaves (individual parking lots). The depth of 2 in tree topology brings about the bottleneck in communication and maintenance. We also designed the information fields used in RFID networks and Sensor Networks.

  • PDF

A Study on CVE Improvement Plans to improve Cloud Service Security (클라우드 서비스 보안성 향상을 위한 CVE 개선 방안 연구)

  • Kim Taekyung;Jung Sungmin
    • Journal of Korea Society of Digital Industry and Information Management
    • /
    • v.19 no.2
    • /
    • pp.39-46
    • /
    • 2023
  • The rise in popularity of cloud services has brought about a heightened concern for security in the field of cloud computing. As a response, governments have implemented CSAP(Cloud Security Assurance Program) to ensure the security of these services. However, despite such measures, the emergence of various security vulnerabilities persists, resulting in incidents related to cloud security breaches. To address this, the utilization of Common Vulnerabilities and Exposures (CVE) has been proposed as a means to facilitate the sharing of vulnerability information across different domains. Nevertheless, the unique characteristics of cloud services present challenges in assigning CVE IDs to the diverse range of vulnerabilities within the cloud environment. In this study, we analyzed how CVE can be effectively employed to enhance cloud security. The assignment of a CVE ID is contingent upon the fulfillment of three rules in the Counting Decision and five rules in the Inclusion Decision. Notably, the third rule in the Inclusion Decision, INC3, clashes with the nature of cloud services, resulting in obstacles in assigning CVE IDs to various cloud vulnerabilities. To tackle this issue, we suggest the appointment of designated individuals who would be responsible for overseeing specific areas of cloud services, thereby enabling the issuance of CVE IDs. This proposed approach aims to overcome the challenges associated with the unique characteristics of cloud services and ensure the seamless sharing of vulnerability information. Information sharing regarding vulnerabilities is crucial in the field of security, and by incorporating cloud vulnerabilities into the CVE system, this method can contribute to enhancing the security of cloud services.

Forced Flow Dryout Heat Flux in Heat Generating Debris Bed (열을 발생하는 Debris층에서의 강제대류 Dryout 열유속)

  • Cha, Jong-Hee;Chung, Moon-Ki
    • Nuclear Engineering and Technology
    • /
    • v.18 no.4
    • /
    • pp.273-280
    • /
    • 1986
  • The purpose of this study is to obtain the experimental data of the forced flow dryout heat flux in a heat generating debris bed which simulates the degraded nuclear reactor core after severe accident. An experimental investigation has been conducted of dryout heat flux in an inductively heated bed of steel particles with upward forced flow rising coolant circulation system under atmospheric pressure. The present observations were mainly focused on the effects of coolant mass flux, particle size, bed height, and coolant subcooling on the dryout heat flux The data were obtained when carbon steel particles in the size distribution 1.5, 2.5, 3.0 and 4.0 mm were placed in a 55 mm ID Pyrex glass column and inductively heated by passing radio frequency current through a multiturn work coil encircling the column. Distilled water was supplied with variation of mass flux from 0 to 3.5 kg/$\textrm{cm}^2$ s as a coolant in the tests, while the bed height was selected as 55 mm and 110 mm. Inlet temperature of coolant varied by 2$0^{\circ}C$ and 8$0^{\circ}C$. The principal results of the tests are: (1) Dryout heat flux increases with increase of upward forcing mass flux and particle size; (2) The dryout heat flux at the zero mass flux obviously depends on the Particle size as Previous studies; (3) The forced flow dryout heat flux in the shallow bed is somewhat higher than that in the deep bed,

  • PDF

Production of Monoclonal Antibody against Escherichia coli O157:H7 and Development of Enzyme Linked Immunosorbent Assay (Escherichia coli O157:H7의 단크론성 항체 생산과 효소면역분석법의 개발)

  • Ryu, Hee-Jeong;Kim, Jeong-Sook;Kim, Kyeong-Yeol;Nam, Bo-Ram;Nam, Min-Ji;Shim, Won-Bo;Kim, Nam-Soo;Cho, Yong-Jin;Chung, Duck-Hwa
    • Korean Journal of Food Science and Technology
    • /
    • v.42 no.3
    • /
    • pp.329-334
    • /
    • 2010
  • Escherichia coli O157:H7 causes hemolytic uremic syndrome and hemorrhagic colitis in humans. The objectives of this study were to produce monoclonal antibody(MAb) against E. coli O157:H7 and to develop an enzyme linked immunosorbent assay(ELISA) for the rapid detection of E. coli O157:H7 in agri-stockbreeding. The characterization of MAb produced from hybridoma cell (HKEC 4G8-5) was validated by ELISA and Western blot. The produced MAb was specific to E. coli O157:H7 and showed weak cross-reaction to Staphylococcus aureus. The detection limit of ELISA based on 4G8-5 MAb was $10^5\;cell/mL$. Although the ELISA could not detect E. coli O157:H7 in the meat and sprout samples inoculated with $1{\times}10^1\;cell$/10 g without enrichment, the same samples after enrichment for 6 hr were confirmed to be positive by ELISA. These results indicated that the ELISA combined with short enrichment (6 hr) is useful tool for rapid screening of E. coli O157:H7 in various samples.

Studies on the Interactions of $M_1-,M_2-receptors$ with Nicotinic Receptors in Rabbit Sympathetic Ganglia (가토 교감신경절에서 무스카린성 수용체 아형과 니코틴성 수용체의 상호작용에 대한 연구)

  • Kim, Jong-Keun;Rhu, Choon-Sik;Kang, Sam-Suk
    • The Korean Journal of Pharmacology
    • /
    • v.28 no.2
    • /
    • pp.171-179
    • /
    • 1992
  • Effects of a $M_1$ receptor antagonist, pirenzepine, a $M_2$ receptor antagonist, AF-DX116, and a nicotinic receptor antagonist, mecamylamine on the pressor responses to preganglionic sympathetic nerve stimulation (PNS) and McN-A-343 and DMPP in spinal (pithed) rabbits were investigated, in order to elucidate a functional role of $M_1$, $M_2$ and nicotinic receptors in ganglionic transmission. Pirenzepine and AF-DX116 selectively inhibited the McN-A-343-induced pressor response in chlorisondamine-treated rabbit and the BCh-induced bradycardia, respectively. Electrical stimulations of preganglionic sympathetic outflow at T8 level produced increases in blood pressure. Pirenzepine $(3\;{\mu}g/kg)$ significantly inhibited the PNS-induced pressor response and the degree of inhibition was not changed by increasing the doses to $100\;{\mu}g/kg$. AF-DX116 $(100\;{\mu}g/kg)$ had no effect on the PNS-induced pressor response. Mecamylamine inhibited the PNS-induced pressor response in a dose-dependent manner. The inhibitory action of mecamylamine was significantly augmented by combined-treatment with pirenzepine $(30\;{\mu}g/kg)$ but AF-DX116 $(100\;{\mu}g/kg)$ did not affect the inhibitory action of mecamylamine. McN-A-343 and DMPP elicited pressor response in the spinal rabbit. Pirenzepine and AF-DX116 dose-dependently inhibited the McN-A-343-induced pressor response but they did not affect DMPP-induced pressor response. Mecamylamine inhibited both pressor responses induced by McN-A-343 and DMPP. These results suggest that not only nicotinic receptors but also $M_1$ receptors play a facilitatory role in ganglionic transmission but $M_2$ receptors do not contribute the transmission in spinal (pithed) rabbits.

  • PDF

A Study on the Synthesis, Labeling and Its Biodistribution of Estradiol Derivatives (에스트라디올 유도체의 합성, 표지 및 체내동태에 관한 연구)

  • Kim, Sang-Wook;Yang, Seung-Dae;Suh, Yong-Sup;Chun, Kwon-Soo;Ahn, Soon-Hyuk;Lim, Soo-Jung;Choi, Chang-Woon;Lim, Sang-Moo;Kim, Young-Soon;Yu, Kook-Hyun
    • The Korean Journal of Nuclear Medicine
    • /
    • v.34 no.5
    • /
    • pp.403-409
    • /
    • 2000
  • Objectives: Due to the heterogeneous receptor distribution and changes of receptor status over time, the biochemical measurement of estrogen receptor status of biopsy specimens is not sufficient to diagnose breast cancer. As a result, I-123 labeled estradiols have been applied for the diagnosis. The purpose of this study was to develop a suitable radioligand for imaging estrogen receptor-positive human breast tumors. Methods: Among the various estradiol derivatives, $17{\alpha}-[^{123}I]$iodovinyl estradiol ($[^{123}I]$IVE) has been prepared from $17{\alpha}$-ethynyl estradiol. Labeling of $E-17{\alpha}-[^{123}I]$iodovinyl estradiol (E-$[^{123}I]$IVE) was carried out using peracetic acid with $[^{123}I]NaI\;and\;Z-[^{123}I]IVE$ labelling was archived using chloamine-T/HCl solution with $[^{123}I]$NaI. Labeling yield was determined by silica thin-layer chromatography (TLC) and radiochemical purity was measured by high performance liquid chromatography (HPLC). The biodistribution of E-$[^{123}I]$IVE was measured in immature female rats at 60 min, 120 min and 300 min after injection. Results: The labeling yield of two isomers was 92% and 94% ($E-[^{123}I]IVE\;and\;Z-[^{123}I]IVE$, respectively). The radiochemical purity was more than 98% after purification. The highest uptake was observed at 120 min in uterus (3.11% ID/g for E-$[^{123}I]$IVE). Conclusion: These results suggest the possibility of using E-$[^{123}I]$IVE as an imaging agent for the evaluation of the evaluation of the presence of estrogen receptor in patients with breast cancer.

  • PDF

Comparison of Direct-labeling Method of Antibody with $^{99m}Tc$ and $^{188}Re$ (농양이식백서에서 $^{99m}Tc,\;^{188}Re$ 직접표지항체의 비교)

  • Choi, Tae-Hyun;Lim, Sang-Moo;Choi, Chang-Woon;Woo, Kwang-Sun;Chung, Wee-Sup;Lim, Soo-Jeong
    • The Korean Journal of Nuclear Medicine
    • /
    • v.33 no.1
    • /
    • pp.84-93
    • /
    • 1999
  • Purpose: We investigated the direct labeling method of antibody with $^{99m}Tc$ and $^{188}Re$ and examined the stability and function of these labeled compounds in in vitro and in vivo. Materials and Methods: Disulfide bond of nonspecific human IgG was reduced to -SH group by 2-mercaptoethanol. Stannous ion was used to reduce $^{99m}Tc$ and $^{188}Re$. The stability of $^{99m}Tc$-IgG and $^{188}Re$-IgG was estimated upto 24 hrs. Biodistribution was evaluated in abscess bearing rats at 4 and 24 hr post-injection of $^{99m}Tc$ or $^{188}Re$ labeled IgG. Results: The number of -SH group per reduced IgG molecule was 2.34. The labeling yield of $^{99m}Tc$-IgG and $^{188}Re$-IgG were 90% and 95%, respectively The stability of $^{99m}Tc$-IgG at 1, 4, 6 and 24 hr was 91%, 83%, 78%, 7% and that of $^{188}Re$-IgG at 1, 4, 16 and 24 hr was 94%, 80%, 47%, 42%, respectively. At 4 hr post-injection of $^{99m}Tc$-IgG, high uptake was found on kidney, blood, stomach and abscess ($9.42{\pm}0.68,\;1.43{\pm}0.24,\;0.86{\pm}0.18,\;0.72{\pm}0.10$ %ID/g, respectively). The uptakes at 24 hr were kidney, abscess,.itomach, and blood in descending order. In case of $^{188}Re$-lgG, high uptake at 4 hr post injection appeared on kidney, blood, abscess and stomach ($3.92{\pm}0.62,\;1.32{\pm}0.08,\;0.88{\pm}0.01,\;0.26{\pm}0.06$, respectively). The uptakes at 24 hr were kidney, abscess, blood and stomach in descending order. The abscess to blood uptake ratio of $^{99m}Tc$-IgG was 0.5 at 4 hr and 2.02 at 24 hr and that of $^{188}Re$-IgG was 0.67 and 1.29. Conclusion: $^{99m}Tc$-IgG and $^{188}Re$-IgG canbe labeled efficiently with direct labeling method. However, $^{99m}Tc$-IgG and $^{188}Re$-IgG, labeled with direct method, was unstable. Further study is needed to enhance the stability of the antibody labeling.

  • PDF