• Title/Summary/Keyword: Ice Storage System

Search Result 173, Processing Time 0.028 seconds

Study on the Performance Testing of the Closed Ice Thermal Energy Storage System using Screw Capsules (스크류 캡슐형 밀폐식 빙축열시스템의 성능시험에 관한 연구)

  • Kim, Kyung-Hwan
    • Journal of the Korean Solar Energy Society
    • /
    • v.26 no.4
    • /
    • pp.39-45
    • /
    • 2006
  • The decrease in the summer peak electric load in our country is very important. The government has arranged and implemented a lot of support policies and statutes to decrease the peak electric load. And the ice thermal energy storage system is known as one of the alternatives. The purpose of this paper is to evaluate the efficiency and thermal characteristics of the closed ice thermal energy storage system using screw capsules. The measured thermal energy storage density is about 18.4 USRT-h/m3 (=232.9 MJ/m3), which is higher than 13.0 USRT-h/m3 (=164.6 MJ/m3), a low criterion of normal performance. And The efficiency of the discharging process and the total energy utilization is 96.2% and 2028.4 kcal/kWh respectively.

A study on the Operating Characteristics of the Capsule-type Ice Storage System (캡슐형 빙축열 시스템의 운전특성에 관한 연구)

  • Kim, Kyung-Hwan;Cho, Sung-Woo;Choi, Jeong-Min;Ha, Suk-Young
    • Proceedings of the SAREK Conference
    • /
    • 2005.11a
    • /
    • pp.199-204
    • /
    • 2005
  • The decrease of summer peak electric load of our country is very important. The government is arranging a lot of support policies and statutes. etc. to decrease of peak electric load. And ice storage system is known as one of the alternatives. The purpose of this study is to collect basic data for operating characteristics to plan the most suitable operation of capsule-type ice storage system. The storaging tank is designed to take charge 40% of total cooling load in building, In operation condition the storage tank took charge 50%. Coefficient Of Performance of daily screw refrigerator is around 4.

  • PDF

Flow pattern analysis and a study on formation of slurry ice in the reversing flow (역전 유동층 내의 유동해석 및 슬러리아이스 생성에 관한 연구)

  • Oh, Cheol;Choi, Young-Gyu
    • Proceedings of the Korean Society of Marine Engineers Conference
    • /
    • 2011.06a
    • /
    • pp.202-202
    • /
    • 2011
  • Thermal energy storage(TES) cooling system using cheaper electricity of off-peak time has been applied to relief a significant portion of the peak demand of electricity during the daytime in summer. Slurry ice type thermal energy storage cooling system is one kind of more efficient ice-thermal energy storage cooling system than Ice-on-Coil type or Encapsulated type TES cooling system, even though, which are more popular TES system. This study is experimented to observe flow pattern and formation of slurry ice in reversing flow to improve efficiency of heat transfer between fluid and freezing tube.

  • PDF

Ice-slurry Generation of Ice Thermal Energy Storage System using Ultrasonic Vibration (초음파 진동을 이용한 빙축열 시스템의 아이스 슬러리 생성 연구)

  • Byon, Sung-Kwang;Gong, Chun-Su;Kim, Nam Woong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.2
    • /
    • pp.578-584
    • /
    • 2013
  • Ice slurry that is a mixture of fine ice crystals and liquid water is a widely used working fluid in the ice thermal energy storage system due to its flowability and large latent heat of fusion. Generally ice slurry is made from supercooled water. But the excessive supercooling causes the water to freeze even worse to block the pipe. Additionally large degree of supercooling of water degrades the efficiency of the ice thermal energy storage system. Therefore the effective method to control the phase change from supercooled water to ice slurry is needed. In this paper we experimentally studied a novel method to generate the ice slurry from the supercooled water using the ultrasonic vibration. It was found that the cavitation impact of supercooled water by ultrasonic vibration can help the generation of ice slurry.

A Study on Formation of Slurry Ice by using the Reversing Flow in a Bundle of Tube (역전 유동층을 이용한 관군 내에서의 슬러리아이스 생성에 관한 연구)

  • Oh, Cheol;Choi, Young-Gyu
    • Journal of Navigation and Port Research
    • /
    • v.35 no.5
    • /
    • pp.365-370
    • /
    • 2011
  • The ice-thermal energy storage cooling system has been applied to relief a significant portion of the peak demand of electricity during the daytime in summer. Slurry ice type system is one kind of ice-thermal storage cooling system utilizing cheaper off-peak electricity. This study is experimented to observe an influence of experimental conditions on production characteristics of slurry ice by using reversing flow, which is putting reversing material into test section to disturb ice adhesion. At this experiment, poly propylene ball of dimeter 10 mm was used as reversing material, and ethylene glycol-water solution of 20wt% concentration was used as flow material. The experimental apparatus was constructed of the slurry ice making and storage tank(test section), the brine tank, pumps for ethylene glycol-water solution and brine circulating, a mass flow-meter, data logger for fluid temperature measuring. The experiments were carried out under various conditions, with volumetric flow rate, ball filling rate and air filling rate.

Experimental Study on The Running Characteristics of Showcase Using Cold Storage System (과냉각 축냉시스템을 적용한 쇼케이스의 운전 특성에 대한 실험적 연구)

  • Lee, Dong-Won;Kim, Jeongbae
    • Journal of the Korean Solar Energy Society
    • /
    • v.32 no.6
    • /
    • pp.22-28
    • /
    • 2012
  • The purpose of this study was to show how tomaintain high efficiency and to use reasonably when being applied the cold-heat storage systems to the showcase. An experimental study was performed to manufacture the showcase system in a laboratory. Comparing the result at general operation condition with that of the new condition using ice storage system, this study showed the effects of the refrigerant sub-cooling, and with using inverter. Using ice storage system, the ice making process was operated during midnight being not needed the cooling of the showcase through the continuous running of the condenser unit. And then, the refrigerant was sub-cooled using the stored cold-heat after being discharged from the air cooling condenser during the day time. Through the experiments, the load transfer rate for the showcase using inverter and ice storage was estimated about 30.0%. And showed that the total power consumption of the showcase with inverter could be reduced about 37% than that of the showcase without inverter.

An Experimental Study on tee Heat Transfer Enhancement Effect of the Coil Fins for Ice Storage System (빙축열 시스템에서의 코일 휜의 열전달 촉진 효과에 관한 실험적 연구)

  • 성병호;이분희;임광빈;김철주
    • Proceedings of the Korea Society for Energy Engineering kosee Conference
    • /
    • 2004.05a
    • /
    • pp.219-224
    • /
    • 2004
  • The present study was to investigate the heat transfer enhancement effect of coil wire fins in an ice storage system. For the two cases of tubes with internal brine flows, a finned tube with coil wires on its outer surface and a smooth tube, the rates of ice layer were tested and compared for both the icing processes. The coil fins were made of a stainless steel wire with a dia. of 2.0(mm), and the coil had an outer dia. of 10(mm) and a helix angle of 60($^{\circ}$). The experimental results showed that the coil fins could substantially reduce the thermal resistance of the ice layer, and enhance the heat flow rates between the water in the storage tank and the brine. The ice storing time was found to be shortened by 13(%) for the coil fins to get the same amount of ice layer that was built on the smooth tube wall for 10 hours of operation when the same thermal conditions were provided.

  • PDF

Effect of supercooling and cooling rate on a continuous ice slurry formation using a plate heat exchanger (판형 열교환기에서 유동 과냉도 및 냉각속도가 연속제빙에 미치는 영향)

  • Lee, Dong-Gyu;Peck, Jong-Hyun;Hong, Hi-Ki;Kang, Chae-Dong
    • Proceedings of the SAREK Conference
    • /
    • 2006.06a
    • /
    • pp.138-143
    • /
    • 2006
  • The peculiarity of ice slurry, such as liquidity, high heat transfer rate and easy storage can also find to supercooled type dynamic ice storage system(DISS) which is one of the DISS. However, in order to accomplish continuous ice formation in the system without mechanical moving parts, supercooled aqueous solutionshould be formed stable through cooling heat exchanger and be dissoluted in storage tank. In previous research, the time of ice slurry increased as the pressure of the cooling heat exchanger(PHX) increased. In this study, a cooling experiment of an ethylene glycol 7mass% solution was performed with various inlet temperature of the PHX, which has constant brine inlet temperature of $-7^{\circ}C$. The temperature in the storage tank maintained to freezing point of the solution. At results, the time of ice slurry formation increased as the supercooling degree decreased and the cooling rate increased.

  • PDF

Modelling of Thermal Discharge Performance for Ice-on-coil Type Ice-Storage Tank (관외착빙형 빙축열조의 방열성능 모델링)

  • Lee, Sang-Ryoul;Lee, Kyoung-Ho;Choi, Byoung-Youn;Han, Seong-Ho
    • Proceedings of the KSME Conference
    • /
    • 2001.06d
    • /
    • pp.280-285
    • /
    • 2001
  • This paper presents a modelling of thermal discharge performance for a static ice-on-coil ice-storage tank. Through the present study, discharging characteristics were examined with the existing results of theoretical and numerical heat transfer analyses. Also, an experiment was conducted to obtain a real set of discharge performance. The thermal effectiveness, the ratio of the actual heat transfer rate to the maximum possible heat transfer rate, decreased when the stored energy decreased during discharging period. And the effectiveness increased as the coolant flow rate through the storage increased, of which increasing rate decreased abruptly near the maximum and the minimum stored energy. An empirical correlation was obtained from the experimental and the numerical analysis data.

  • PDF

The Study on Improvement in Subcooling of TMA Clathrate for PCM in Ice Storage System (빙축열시스템 PCM용 TMA-포접화합물의 과냉도 개선에 대한 연구)

  • Kim, J.H.;Chung, N.K.;Kim, C.O.
    • Proceedings of the KSME Conference
    • /
    • 2003.04a
    • /
    • pp.1663-1666
    • /
    • 2003
  • TMA clathrate that is used by PCM of ice storage system in this research creates hydrate crystallization at higher temperature than pure water, and application is expected as PCM because having comparative big dormant temperature without phase separation phenomenon. In case this research uses TMA clathrate by PCM, choose admixture by purpose to control or remove subcooling of TMA clathrate and evaluated experimentally. Subcooling is improved and can expect contraction of freezing machine running time and increase of coefficient of performance as that add admixture to TMA clathrate conclusively. Also, may supply thermal storage system that apply low temperature potential heat thermal storage material that subcooling is improved more extensively laying stress on medium size building and small size building, can expect allowance through localization of ice storage system.

  • PDF