• Title/Summary/Keyword: IT System

Search Result 103,800, Processing Time 0.126 seconds

The Structure of Korean Radiation Oncology in 1997 (국내 병원 별 방사선치료의 진료 구조 현황(1997년 현황을 중심으로 한 선진국과의 비교 구))

  • Kim Mi Sook;Yoo Seoung Yul;Cho Chul Koo;Yoo Hyung Jun;Yang Kwang Mo;Je Young Hoon;Lee Dong Hun;Lee Dong Han;Kim Do Jun
    • Radiation Oncology Journal
    • /
    • v.17 no.2
    • /
    • pp.172-178
    • /
    • 1999
  • Purpose : To measure the basic structural characteristics of radiation oncology facilities in Korea during 1997 and to compare personnel, equipments and patient loads between Korea and developed countries. Methods and Materials : Mail serveys we conducted in 1998 and data on treatment machines, personnel and peformed new patients were collected. Responses were obtained from the 100 percent of facilities. The consensus data of the whole country were summarized using Microsoft Excel program. Results: In Korea during 1997, 42 facilities delivered megavoltage radiation theraphy with 71 treatment machines, 100 radiation oncologists, 26 medical physicist, 205 technologists and 19,773 new patients. Eighty nine percent of facilities in Korea had linear accelators at least 6 MeV maximum photon energy. Ninety five percent of facilities had simulators while five percent of facilities had no simulator, Ninety one percent of facilities had computer planning systems and eighty three percent of facilities reported that they had a written quality assurance program. Thirty six percent of facilities had only one radiation oncologist and thirty eight percent of facilities had no medical physicists. The median of the distribution of annual patients load of a facility, patients load per a machine, patients load per a radiation oncologist, patients load per a therapist and therapists per a machine in Korea were 348 patients per a year, 263 patients per a machine, 171 patients per a radiation oncologist, 81 patients per a therapist, and 3 therapists per a machine respectively. Conclusions : The whole scale of the radiation oncology departments in Korea was smaller than Japan and USA in population ratio regard. In case of hardware level like linear accelerators, simulators and computer planning systems, there was no big differences between Korea and USA. The patients loads of radiation oncologists and therapists had no significant differences as compared with USA. However, it was desirable to consider the part time system in USA because there were a lot of hospitals which did not employ medical physicists.

  • PDF

Long-Term Observation of Temperature in the Coastal Waters Adjacent to the Wolsung Nuclear Power Plant (월성 원자력 발전소 주변 해역의 장기간 수온관측)

  • Chung, Jong-Yul;Kang, Hyoun-Woo;Shin, Young-Jae;Kim, Kye-Young;Jun, Ho-Kyung
    • The Sea:JOURNAL OF THE KOREAN SOCIETY OF OCEANOGRAPHY
    • /
    • v.3 no.4
    • /
    • pp.183-192
    • /
    • 1998
  • The long-term observation of temperature in the coastal waters adjacent to the Wolsung Nuclear Power Plant has been carried out from November 10, 1996 to August 22, 1997, for approximately 280 days using a real-time temperature measurement buoy system. The sea-surface temperature was measured at every 10 minute using 10 buoys. The vertical structure of temperature was investigated near the outlet of the plant with two thermistor chains equipped with 10 sensors at 1 m interval The monthly averaged temperature was the lowest with spatial average of $12.8^{\circ}C$ in February and was the highest in August with spatial average of $19.6^{\circ}C$. The extremely low temperature was frequently observed between June and August, which seems to be the consequence of the intrusion of cold water near the southeastern coast of Korea. Distributions of the daily and hourly averaged temperature show that the highest temperature always occurred near the outlet of the plant and the warm-water patch moved along the north-south direction with the semidiurnal period. The semidiurnal fluctuation of temperature was also observed near the surface of the vertical profiles. The spectral analysis of temperature between February and April 1997 shows that the semidiurnal components prevailed near the outlet. It is likely that the semidiurnal components were due to the prevailing semidiurnal tide in this region. In August 1997, the diurnal components were dominant at the surface water of all stations except Station 12, which suggests that the warm water from the outlet of the plant has less effects in summer on the surrounding waters than the strong solar radiation.

  • PDF

Design of Ultrasonic Nebulizer for Inhalation Toxicology Study of Cadmium with Application of Engineering Methodology and Performance Evaluation with Light-Scattering Photometer (공학적 기법을 응용한 카드뮴의 흡입독성 연구를 위한 초음파 네뷸라이져의 설계 그리고 광산란 광도계를 이용한 성능평가)

  • Jeung Jae Yeal;Milton Donald K.;Kim Tae Hyeung;Lee Jong Young;Chong Myoung Soo;Ko Kwang Jae;Kim Sang Duck;Kang Sung Ho;Song Young Sun;Lee Ki Nam
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.16 no.3
    • /
    • pp.464-471
    • /
    • 2002
  • Author applied several engineering methodologies to classical ultrasonic nebulizer to cope with it's demerits. After several trials and errors, we got the several meaningful results. To evaluate the modified ultrasonic nebulizer for inhalation toxicology of cadmium, author used light-scattering photometer. This paper is the one part of inhalation exposure systems for inhalation toxicology study of cadmium. According to the testing conditions, source temperature 50℃ and inlet-duct band temperature 150℃, aerosol generation results for sodium chloride and cadmium chloride were as followings: Coefficients of variation(CV) of sodium chloride and cadmium chloride for repeated trials were 3.38 and 4.77 for 10g, 2.47 and 5.02 for 5g, and 4.70 and 2.98 for 2.5g. All the CVs were within 10% of acceptance variability. Count Per Minute(CPM) changes of NaCl and CdCl₂ for 5 repeated trials were similar. CPM ratios of CdCl₂/NaCl were 1.13 for 10g, 0.76 for 5g, and 1.06 for 2.5g. Relative aerosol generation of cadmium chloride to sodium chloride was the highest in 10g. Efficiency increases of 24.50% for 5g NaCl, 14.91 % for 2.5g NaCl, and 16.48% for 2.5g CdCl₂ with respect to theoretical efficiency were observed but 0.04% efficiency decrease was observed in 5g CdC₂. According to the modifications of source temperature(20, 50, 70℃) and inlet-duct band temperature(20, 50, 100, 150, 200℃), aerosol generation results for NaCl and CdCl₂ were as followings: CPM trends for each quantity excepting 10g NaCl in inlet-duct band temperature 200℃ were similar, and the highest CPM was observed in source temperature 70℃ to each inlet-duct band temperature. The highest CPMs to 10, 5, and 2.5g NaCl were observed in source temperature 70℃ and inlet-duct band temperature 20℃. Aerosol generation of cadmium chloride was increased with the higher source temperature, excepting inlet-duct band temperature 200℃. The highest CPMs for 10, 5, and 2.5g CdCl₂ were observed in source temperature 70℃ and inlet-duct band temperature 20℃, and this trend was similar to NaCl aerosol generation The highest CPMs for 10, 5, and 2.5g CdCl₂ were observed in source temperature 70℃ and inlet-duct band temperature 20℃, and this result was similar to NaCl aerosol generation. Observed efficiencies of 5 and 2.5g NaCl were similar to ifs theoretical efficiency but -3.08% efficiency decrease of 5g CdCl₂, 17.47% efficiency increase of 2.5g CdCl₂ were observed. CPM ratio of CdCl₂/NaCl of 10g was different to 5 and 2.5g, and 2.5g ratio was higher than 5g ratio. In conclusion, to get maximum aerosol generation for NaCl and CdCl₂ will be the conditions that set the appropriate inlet-duct band temperature for each materials and increase the source temperature. Sodium chloride can be used to evaluate the performance and predict the concentration for cadmium aerosol in aerosol generator and inhalation exposure system.

Comparison of Radiologic Parameters between Weight Bearing Affected Both Ankle and Single Ankle in Ankle Exam (체중부하 상태의 족관절 검사시 양측 족관절 동시 검사와 편측 족관절 검사의 방사선학적 비교)

  • Cha, Sangyoung;Shin, Jaehan;Choi, Namgil
    • Journal of the Korean Society of Radiology
    • /
    • v.10 no.8
    • /
    • pp.603-610
    • /
    • 2016
  • This study was performed to analyze the results of radiologic parameters compared both leg weight bearing position to single leg weight bearing position in ankle osteoarthritis. Between January 2016 and June 2016, 25 patients (50 ankles) who visited our Hospital to treat ankle pain. In radiographic assessment, We masured tibial anterior surface angle(TAS), tibial medial malleolar angle(TMM), talar tilting angle(TT), joint space width(JSW), tibiotalar joint space, fibulotalar joint space of ankle as radiologic parameters. On the right leg of the both leg weight bearing position, TAS was $87.24^{\circ}$, TT was $6.44^{\circ}$, TMM was $26.76^{\circ}$, fibulotalar joint space was 0.98mm. Right leg of the single leg weight bearing position, TAS was $88.93^{\circ}$, TT was $2.41^{\circ}$, TMM was $19.77^{\circ}$, fibulotalar joint space was 1.6mm. And then, on the left leg of the both leg weight bearing position, TAS was $87.25^{\circ}$, TT was $5.71^{\circ}$, TMM was $23.92^{\circ}$, fibulotalar joint space was 1.22 mm and left leg of the single weight bearing position, TAS was 88.75, TT was $3.19^{\circ}$, TMM $21.45^{\circ}$, fibulotalar joint space was 1.22 mm. There are unsimilarity between measure values of TAS and tibiotalar joint space. As the result of test of weight bearing ankle study, it would be more exact to examine to measure one side in the first time rather than both to conclude on accurate measurement.

A Mutual P3P Methodology for Privacy Preserving Context-Aware Systems Development (프라이버시 보호 상황인식 시스템 개발을 위한 쌍방향 P3P 방법론)

  • Kwon, Oh-Byung
    • Asia pacific journal of information systems
    • /
    • v.18 no.1
    • /
    • pp.145-162
    • /
    • 2008
  • One of the big concerns in e-society is privacy issue. In special, in developing robust ubiquitous smart space and corresponding services, user profile and preference are collected by the service providers. Privacy issue would be more critical in context-aware services simply because most of the context data themselves are private information: user's current location, current schedule, friends nearby and even her/his health data. To realize the potential of ubiquitous smart space, the systems embedded in the space should corporate personal privacy preferences. When the users invoke a set of services, they are asked to allow the service providers or smart space to make use of personal information which is related to privacy concerns. For this reason, the users unhappily provide the personal information or even deny to get served. On the other side, service provider needs personal information as rich as possible with minimal personal information to discern royal and trustworthy customers and those who are not. It would be desirable to enlarge the allowable personal information complying with the service provider's request, whereas minimizing service provider's requiring personal information which is not allowed to be submitted and user's submitting information which is of no value to the service provider. In special, if any personal information required by the service provider is not allowed, service will not be provided to the user. P3P (Platform for Privacy Preferences) has been regarded as one of the promising alternatives to preserve the personal information in the course of electronic transactions. However, P3P mainly focuses on preserving the buyers' personal information. From time to time, the service provider's business data should be protected from the unintended usage from the buyers. Moreover, even though the user's privacy preference could depend on the context happened to the user, legacy P3P does not handle the contextual change of privacy preferences. Hence, the purpose of this paper is to propose a mutual P3P-based negotiation mechanism. To do so, service provider's privacy concern is considered as well as the users'. User's privacy policy on the service provider's information also should be informed to the service providers before the service begins. Second, privacy policy is contextually designed according to the user's current context because the nomadic user's privacy concern structure may be altered contextually. Hence, the methodology includes mutual privacy policy and personalization. Overall framework of the mechanism and new code of ethics is described in section 2. Pervasive platform for mutual P3P considers user type and context field, which involves current activity, location, social context, objects nearby and physical environments. Our mutual P3P includes the privacy preference not only for the buyers but also the sellers, that is, service providers. Negotiation methodology for mutual P3P is proposed in section 3. Based on the fact that privacy concern occurs when there are needs for information access and at the same time those for information hiding. Our mechanism was implemented based on an actual shopping mall to increase the feasibility of the idea proposed in this paper. A shopping service is assumed as a context-aware service, and data groups for the service are enumerated. The privacy policy for each data group is represented as APPEL format. To examine the performance of the example service, in section 4, simulation approach is adopted in this paper. For the simulation, five data elements are considered: $\cdot$ UserID $\cdot$ User preference $\cdot$ Phone number $\cdot$ Home address $\cdot$ Product information $\cdot$ Service profile. For the negotiation, reputation is selected as a strategic value. Then the following cases are compared: $\cdot$ Legacy P3P is considered $\cdot$ Mutual P3P is considered without strategic value $\cdot$ Mutual P3P is considered with strategic value. The simulation results show that mutual P3P outperforms legacy P3P. Moreover, we could conclude that when mutual P3P is considered with strategic value, performance was better than that of mutual P3P is considered without strategic value in terms of service safety.

Video Assisted Thoracoscopic Sympathetic Ramus Clipping in Essential Hyperhidrosis -Cadaver Fitting Test and Clinical Application (다한증 환자에서 클립을 이용한 교감신경 교통가지 차단술 -사체 연구 및 임상적용-)

  • Lee, Sung-Ho;Cho, Seong-Joon;Jung, Jae-Seung;Kim, Tae-Sik;Son, Ho-Sung;Sun, Kyung;Kim, Kwang-Taik;Kim, Hyoung-Mook
    • Journal of Chest Surgery
    • /
    • v.36 no.8
    • /
    • pp.595-601
    • /
    • 2003
  • Background: It has been known that the most effective treatment method of hyperhidrosis is video-assisted thoracoscopic sympathetic nerve block. Postoperative compensatory hyperhidrosis and anhidrosis are major factors that decrease the postoperative satisfaction. Although sympathetic rami have been selectively blocked to decrease the complications, technical difficulties and excessive bleeding have prevented the universal application. Material and Method: Three pre-fixative cadavers were dissected before clinical application. Bilateral sympathetic chains were exposed in supine position after the whole anterior chest wall was removed. Second and third sympathetic rami were blocked using clips. After the sympathetic chains including ganglia were removed, we evaluated the extents of rami block. Twenty-five patients were subjected to the clinical application. Surgeries were performed in semi-fowlers position under general anesthesia and bilateral ventilation. 2 mm thoracoscopy and 5 mm trocar were intro-duced through third and fourth intercostal space, respectively. Second and third sympathetic rami were blocked using thoracoscopic clips. The postoperative complications, satisfaction, and compensatory hyperhidrosis rate were evaluated retrospectively. Result: Sympathetic rami were completely blocked in cadaver dissection study Hyper-hidrosis symptom was improved in all patients without operative complication. Operative time was shorter than that of traditional ramicotomy. All patients, except four, were satisfied with postoperative palmar hyperhidrosis. Com-pensatory hyperhidrosis was more severely happened in fifteen patients (60%). The remaining six patients had no complaint. Two patients had a minimal degree of gustatory hyperhidrosis. Conclusion: This operative method had shorter operative time and less complication rate, compared with traditional ramicotomy Operative success rate was similar to the traditional syrnpathicotorny; lower extent and occurrence rate of compensatory hyperhidrosis. The thoracic sympathetic rami clipping was suggested as an alternative method for treatment of palmar hyperhidrosis.

Radiopharmceutical Factors in the Prepartion of $^{99m}Tc-HMPAO$ Images of the Brain (뇌스캔용 $^{99m}Tc-HM-PAO$의 방사성 동위원소표지에 영향을 미치는 인자에 대한 연구)

  • Yeom, Mi-Kyoung;Kim, Sang-Eun;Lee, Dong-Soo;Chung, June-Key;Lee, Myung-Chul;Koh, Chang-Soon
    • The Korean Journal of Nuclear Medicine
    • /
    • v.25 no.1
    • /
    • pp.117-121
    • /
    • 1991
  • Technetium-99m-hexamethylpropyleneamine oxime $(^{99m}Tc-HM-PAO)$ is a neutral-lipophilic chelate which is used for scanning cerebral blood flow. The labeling efficiencies of $^{99m}Tc-HM-PAO$ is known to be sensitive to the amount of pertechnetate added and the quality of the pertechnetate. Because of these factors, the manufacture recommends that HM-PAO kits be reconstituted with a maximum of 30 mCi pertechnetate which was eluted <4 hr earlier from a generator which had been eluted < 24 hr previously. So we measured the labelling efficiencies and the decomposition rate constant according to the amount of pertechnetate added, the volume of pertechnette added, and generator in-growth time. We used the 3-system chromatographic methods (paper & ITLC-SG chromatography) which analyzed the labelling efficiencies of the $^{99m}Tc-HM-PAO$. There was no significant difference in labelling efficiencies between variable pertechnetate acitvities added. ($39.9{\pm}4.9\;mCi:\;87.8{\pm}5.1\;(%)$, $60.8{\pm}5.0\;mCi:\;90.7{\pm}2.2\;(%)$, $79.0{\pm}6.0\;mCi:\;86.8{\pm}3.9\;(%)$, $106.6{\pm}11.6\;mCi:\;87.7{\pm}1.2\;(%)$, p>0.05) No significant difference in labelling efficiencies were found between pertechnetate of 4ml and 5ml. (4ml : $89.1{\pm}3.2(%)$, 5ml: $87.3{\pm}4.0(%)$, p>0.05). There was no difference between 1-6 and 10-48 hr of generator in-growth time. (1-6 hr: $87.8{\pm}4.0(%)$, 10-48 hr: $89.6{\pm}1.6(%)$, p>0.05) The mean value of decomposition rate constant was $0.196{\pm}0.097\;(hr^{-1})$, and there were no difference according to the amount of pertecnetate added and the volume of pertecnetate added, ($39.9{\pm}4.9\;mCi:\;0.208{\pm}0.059\;(hr^{-1})$, $60.8{\pm}5.0\;mCi:\;0.191{\pm}0.100\;(hr^{-1})$ $79.0{\pm}6.0\;mCi:\;0.192{\pm}0.118\;(hr^{-1})$, $106.6{\pm}11.6\;mCi:\;0.212{\pm}0.030\;(hr^{-1})$, p>0.05, 4 ml: $0.200{\pm}0.074\;(hr^{-1})$, Sml: $0.193{\pm}0.115\;(hr^{-1})$, p>0.05). In the case of using the first eluate, the labelling efficiency of $^{99m}Tc-HM-PAO$ W3S 82.1%. These data suggest that there were no significant alteration in labelling efficiency of $^{99m}Tc-HM-PAO$ according to the considerable range of pertechnetate activities and volume added, and generator in-growth time. Also, it was shown that one vial of HM-PAO kit supplied the $^{99m}Tc-HM-PAO$ which was used for 3-4 patients.

  • PDF

The Evaluation of Usefulness of Wide Beam Reconstruction Method on Segmental Perfusion and Regional Wall Motion in Myocardial Perfusion SPECT (심근관류 SPECT의 분절별 관류 및 국소벽 운동에서 Wide Beam Reconstruction기법의 유용성 평가)

  • Seong, Yong-Joon;Kim, Tae-Yeob;Moon, Il-Sang;Cho, Seong-Wook;Woo, Jae-Ryong
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.15 no.1
    • /
    • pp.51-57
    • /
    • 2011
  • Purpose: The aim of this study is to identify clinical usefulness of Wide Beam Reconstruction (WBR) which is called Xpress.cardiac$^{TM}$ to confirm the agreement between segmental perfusion and regional wall motion in myocardium compared to conventional OSEM method. Materials and Methods: Subjects were separated two groups. First group was composed of 20 normal control group. Second group was composed of 10 patients (abnormal group) who had coronary artery disease. Subjects underwent myocardial perfusion SPECT ($^{201}Tl$ rest and $^{99m}Tc$-MIBI stress). Image acquisition and reconstruction were that rest stage was each step per 30, 15 seconds and stress stage was each step per 25, 13 seconds, OSEM and WBR methods were applied. Segmental perfusion and regional wall motion were applied 20-segment model of QPS, QGS algorithm in AutoQuant. Status of perfusion was composed of 5 point scoring system (0=normal, 1=mild, 2=moderate, 3=severe hypokinesia, 4=dyskinesia). Status of regional wall motion was also composed of 5 point scoring (0=normal, 1=mild, 2=moderate, 3=severe hypokinesia, 4=dyskinesia). We evaluated the agreement between conventional OSEM and WBR through automatic quantification value. Results: The agreement of rest segmental perfusion between conventional OSEM and WBR in normal patients was 99% (396/400, k=0.662, p<0.0001) and one of rest regional wall motion was 83.8% (335/400, k=0.283), the agreement of stress segmental perfusion was 95.8%(383/400, k=0.656), one of stress regional wall motion was 87.3% (349/400, k=0.390). The match rate of rest segmental perfusion in abnormal patients was 83% (166/200, k=0.605, p<0.0001) and one of rest regional wall motion was 55.5% (111/200, k=0.385), the agreement of stress segmental perfusion was 79.5% (159/200, k=0.682), one of stress regional wall motion was 63.5% (127/200, k=0.486). Conclusion: Compared to conventional OSEM, WBR method had a good agreement of segmental perfusion in myocardium in normal and abnormal groups. However regional wall motion showed meaningful low agreement. Although WBR offers high resolution and contrast ratio, it is not useful method for gated myocardial perfusion SPECT.

  • PDF

Anti-inflammatory Effects of Purpurogallin Carboxylic Acid, An Oxidation Product of Gallic Acid in Fermented Tea (발효차중의 미량 성분인 gallic acid 산화물 purpurogallin carboxylic acid의 항염증 효과)

  • Jhoo, Jin-Woo
    • Korean Journal of Food Science and Technology
    • /
    • v.40 no.6
    • /
    • pp.707-711
    • /
    • 2008
  • The principal objective of the current study was to isolate a purpurogallin derivative as an oxidation product from gallic acid, in an effort to assess the anti-inflammatory effects of this compound. Purpurogallin derivative is known to be the one of the oxidation products of gallic acid. This compound has been identified as a minor chemical component in fermented tea products. It has been previously demonstrated that theaflavins, the oxidation products of catechins found in fermented tea products, exert profound antioxidant and anti-inflammatory effects. However, the biological activities of a minor chemical component in fermented teas have yet to be evaluated. Purpurogallin carboxylic acid (PCA) was identified as a major oxidation product of gallic acid from a peroxidase/hydrogen peroxide oxidation model system. The identity of the PCA was verified by $^{1}H$ NMR, $^{13}C$ NMR and MS techniques. PCA treatment significantly suppressed the generation of pro-inflammatory mediators including nitric oxide and IL-6 in lipopolysaccharide (LPS)-stimulated RAW264.7 murine macrophages. According to the nitrite assay, PCA 100, 75, and $50{\mu}g/mL$ treatment dose-dependently inhibited NO production by 57.6, 41.5, and 21.8%, respectively, in LPS-stimulated RAW264.7 murine macrophage cells. Moreover, IL-6 production was inhibited to a significant degree with PCA treatment of 100 and $75{\mu}g/mL$ at 43.1 and 23.9%, respectively. PCA treatment also significantly suppressed $PGE_2$ production at levels of 100 and $75{\mu}g/mL$. These results showed that PCA exerts inhibitory effects on the production of inflammatory mediators.

Patient-related Barriiers to Pain Management in General Population (일반인의 통증관리 장애정도)

  • Yoo, Yang-Sook;Choe, Sang-Ok;Cho, Young-Yi;Koh, Su-Jin;Hor, Soo-Jin;Jeon, Ji-In;Kwon, So-Hi
    • Journal of Hospice and Palliative Care
    • /
    • v.10 no.4
    • /
    • pp.184-189
    • /
    • 2007
  • Purpose: This study was to explore barriers to effective pain management in general population. Methods: Total 163 Participants completed the Barrier Questionnaire-II (BQ-II), a 27-item on a six point scale, from May to June in 2007. BQ-II consisted of four subscales which were 1) physical effects (PE) addressing beliefs that side effects of analgesics are inevitable and concerns about tolerance, fatalism (Fa) addressing fatalistic beliefs about cancer pain and its management, Communication (Co) addressing the beliefs of 'good patient' and concerns of distracting physician from underlying disease, and harmful effects (HE) addressing fear of addiction and harmful effect to immune system of pain medicine. Results: The BQ-II total had an internal consistency of 0.877 in this study. HE was the biggest barrier (3.03) followed by PE (2.73), Fa (2.15), and Co (1.71). Items appeared as great concerns were 'there is a danger of becoming addicted to pain medication'(3.58), 'using pain medicine blocks your ability to know if you have any new pain' (3.18), 'pain medicine is very addictive' (3.09), 'when you use pain medicine your body becomes used to its effects and pretty soon it won't work any more' (3.09), and 'drowsiness from pain medicine is difficult to control' (3.09). Only 12 respondents (7.4%) reported that they took any type of pain education, however, those who took pain education represented significantly lower barriers to pain management than who did not (P=.029). Conclusion: This result suggests the strategies for public education to surmount cancer pain.

  • PDF