• 제목/요약/키워드: ISO 5660-1

검색결과 109건 처리시간 0.026초

국내 유용 건축자재용 수입 목재의 연소특성에 관한 연구 - 북미 산재(Douglas-fir, Western Red cedar)와 아프리카 산재 (Makore, Padauk, Bubinga)를 중심으로 - (A Study on the Combustion Characteristics of Useful Imported Wood for Building Materials - Focusing on the North American species (Douglas-fir, Western Red cedar) and African species(Makore, Padauk, Bubinga) -)

  • 서현정;백종규;이민철
    • 한국안전학회지
    • /
    • 제32권3호
    • /
    • pp.8-14
    • /
    • 2017
  • This study examined the combustion and thermal characteristics of imported woods for building materials in Korea. Wooden specimens were confirmed by a cone calorimeter according to the KS F ISO 5660-1 standard. The combustion properties of the wooden specimens were measured in terms of the heat release rate (HRR), total heat released (THR), mass lose rate (MLR), and ignition time (time to ignition; TTI). The optical microscope was used for determine the anatomical characteristics of wood pit and structure. Also, the thermal properties were measured by thermogravimetric analysis (TGA) to determine the thermal stability of wooden specimens. The result of this experiment would be useful for fundamentals of guiding the combustion properties and thermal stability using wood application.

실내사용 목재의 연소 특성 분석(I) (Combustion Properties of Woods for Indoor Use (I))

  • 손동원;강석구
    • Journal of the Korean Wood Science and Technology
    • /
    • 제42권6호
    • /
    • pp.675-681
    • /
    • 2014
  • 최근 친환경 재료에 대한 국민들의 관심이 높아지면서 실내사용목재의 이용도 증가하고 있다. 본 연구는 실내사용 목재의 내화성 부여를 위한 기초자료로 활용될 수 있는 열특성 분석에 그 목적이 있다. 열방출률과 열방출량, 가스발생량, 중량감소 등의 연소성질을 열중량 분석(TGA) 및 콘칼로리미터(KS F ISO 5660-1)의 방법으로 분석하였다. 분석결과 목재의 재질적 특성은 연소적 특성으로 발현되었으며, 열적성질과 연소가스 발생량과의 관계는 상관관계가 높게 나타났다. 탄화층 형성에 의한 연소억제 효과도 수종에 따라 현저한 차이를 보였다. 총열방출량과 중량감소량은 상관관계가 높게 나타났다. 점화시간과 총열방출량 등의 자료는 목재의 내화성능부여 등의 기초 자료로서 매우 중요하리라 판단되었다.

실물화재 실험을 통한 난연 EPS샌드위치패널의 난연성능 평가 (The Study on Brilliant Performance Appraisal of The EPS Sandwhich Pannel Leads an Actual Fire Test)

  • 최기영;김병선;오재훈;박선영;박효석;문종욱
    • 한국화재소방학회:학술대회논문집
    • /
    • 한국화재소방학회 2011년도 추계학술논문발표회 논문집
    • /
    • pp.57-60
    • /
    • 2011
  • EPS패널의 열방출율과 가스유해성에 대한 연구는 꾸준히 진행되어왔다. 그러나 그 동안의 시험 결과는 KSF ISO 5660-1(콘칼로리미터) 시험규정에 의한 소형시편을 이용한 것으로 난연제의 과다투입 또는 심재의 변형이 쉬워 결과를 신뢰하기 힘들고 실제 생산되는 크기의 샌드위치패널의 난연성능을 판단하기 힘들다. 따라서, 보다 정확한 실물화재시험의 필요성이 요구되고 있다. 난연 EPS샌드위치패널과 일반EPS샌드위치패널의 실물화재 실험결과 난연EPS샌드위치패널은 기타재료의 샌드위치패널과 열방출율, 연기발생율, 부분별 온도분포, 플래시오버등과 같은 난연성능이 EPS샌드위치패널과 우레탄폼패널보다 우수하며, 글라스울과 비슷한 성능을 나태내는 것을 확인 할 수 있다. 그래서 시공성, 경제성 등의 EPS샌드위치패널의 장점을 그대로 유지하며 난연제의 코팅법을 통해 우수한 난연성능을 확보하였다.

  • PDF

암모늄염으로 처리된 리기다 소나무의 연소성질 (Combustion Characteristics of Pinus Rigida Treated by Ammonium Salts)

  • 진의;정영진
    • 한국화재소방학회:학술대회논문집
    • /
    • 한국화재소방학회 2010년도 춘계학술논문발표회 논문집
    • /
    • pp.403-407
    • /
    • 2010
  • 건축 구조재료로 사용되는 소나무의 화재조건을 알아보기 위하여 콘칼로리미터(ISO 5660-1)를 이용하여 연소성질을 분석하였다. 자연 건조된 소나무에 $(NH_4)_2SO_4$, $NH_4H_2PO_4$, $(NH_4)_2HPO_4$ 등의 암모늄염을 이용하여 난연성을 부가하였다. 소나무의 함수율은 10.2%였으며 초기 열방출 곡선은 $(NH_4)_2HPO_4$인 경우 완만하게 증가하였으며 가장 좋은 난연성을 보였다. $HRR_{peak}$ 값은 무처리된 경우 $217\;kW/m^2$, $(NH_4)_2SO_4$, $NH_4H_2PO_4$, $(NH_4)_2HPO_4$인 경우에는 각각 $190\;kW/m^2$, $188\;kW/m^2$, $166\;kW/m^2$로 나타났다. 즉 $(NH_4)_2HPO_4$로 처리된 경우 23.5%의 감소현상이 관찰되었다. $HRR_{peak}$ 도달 시간은 무처리된 시험편(290s) 및 $(NH_4)_2SO_4$, $NH_4H_2PO_4$, $(NH_4)_2HPO_4$으로 처리된 시험편은 각각 298s, 263s, 313s로 나타났다. 연기 발생속도는 사용한 암모늄염 중 $(NH_4)_2SO_4$로 처리된 시험편이 가장 작게 관찰되어 저발연성 감연제 역할을 하는 것으로 판단된다.

  • PDF

필로티 구조물의 화재위험성 분석 및 현장조사에 관한 연구 (A Study on the Analysis of Fire Risk and Field Survey for FilottI Structures)

  • 한지우;이병흔;진승현;권영진
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2018년도 춘계 학술논문 발표대회
    • /
    • pp.45-46
    • /
    • 2018
  • The fire at the pilotis parking lot shows the fire propagation paths that are propagated to the ceiling materials and insulation materials and propagated through the external walls. In addition, there is a high risk of fire caused by vehicles with high combustion loads spreading throughout the parking lot. In particular, the omission of the ceiling materials at the parking lot in recent fire cases has contributed to the spread of the fire. In this study, the combustion performance of the ceiling materials between the insulation material and the vehicle is considered to prevent fire from spreading. Based on field research, the type of ceiling material used in the piloti structure showed that SMC ceiling materials have the highest percentage. Combustion performance test (KS F ISO 5660-1) was carried out on the SMC ceiling materials and the AL ceiling materials to review the fire safety of the ceiling finish based on the field investigation. The results of the test showed that the SMC ceiling materials has a THR 28.973[MJ/㎡] and peek HRR 273.93 [kW/㎡], while the AL ceiling material has a THR 0.584[MJ/㎡] and peek HRR 15.215[kW/㎡].

  • PDF

건축용 내장재의 연소 특성에 관한 연구 (A Study on the Combustion Characteristic of Building Materials)

  • 송재용;사승훈;남정우;김진표;박종택
    • 한국안전학회지
    • /
    • 제26권3호
    • /
    • pp.23-28
    • /
    • 2011
  • This paper studied combustion characteristics of the building materials such as polyurethane-foam, sponge type sound-absorbing materials and styrofoam. To estimate of the combustion characteristics, we carried out combustion experiment of the building materials. And then to evaluate the suitability of the building materials, we measured heat release rate(HRR) and smoke density(Ds) of polyurethane-foam, sponge type sound-absorbing materials and styrofoam using by a cone-calorimeter. From the combustion experimental results, the general type sound-absorbing materials (GSAM) and styrofoam were rapid burned simultaneously with ignition and the incombustibility type sound-absorbing materials(ISAM) and polyurethane-foam had all gone out simultaneously with ignition. Measured results of HRR and Ds were not satisfied KS F ISO 5660-1 and IMO FTP Code, from the results, the polyurethane-foam, the sponge type sound-absorbing material and the styrofoam were ill-suited for using building interior materials.

퍼즐매트의 연소속도에 관한 연구 (A Study on the Burning Rate of Puzzle Mats)

  • 박형주
    • 한국안전학회지
    • /
    • 제23권6호
    • /
    • pp.84-90
    • /
    • 2008
  • The mass loss rate and heat release rate of puzzle mats were analysed using variable external irradiation level. Five samples of puzzle mat were tested in this study : Type A, B, C, D and E. Type A, B and C are all general grades whereas Type D and E are both Flame retardant grades. Incident heat fluxs of $25kW/m^2$, $35kW/m^2$, $50kW/m^2$ and $70kW/m^2$ were selected for these experiments. All samples were tested in the horizontal orientation and were wrapped in a single layer of aluminum foil. Each sample was nominally 20mm thick and 100mm square. The combustion heat and mass loss rate were carried out from Oxygen bomb calorimeter and mass loss calorimeter according to ISO 5660-1 respectively. Heat release rates were calculated using the equation ${\dot{Q}}=A_f{\dot{m}}"_X{\Delta}H_c=0.75A_f{\dot{m}}"{\Delta}H_c$. where $A_f$ is the horizontal burning area of the sample, $\dot{m}"$ is mass loss rate per unit area, ${\Delta}H_c$ is complete heat of combustion and 0.75 is combustion efficiency.

콘칼로리미터와 적외선분광계(FTIR)를 이용한 폼블럭의 연소특성에 대한 실험적 연구 (A Study on the Fire Characterization of Foam block using Cone-calorimeter and FTIR)

  • 한봉훈;서동호;권영희;민세홍
    • 한국화재소방학회논문지
    • /
    • 제31권6호
    • /
    • pp.23-32
    • /
    • 2017
  • 폼블럭은 셀프 인테리어 용품으로 새롭게 유행하고 있는 건축마감재로 폴리에틸렌을 주성분으로 하여 제조되고 있어 화재에 취약할 것으로 판단된다. 시중에 판매되고 있는 폼블럭 2종(일반, 난연)을 KS F ISO 5660-1(연소성능시험)의 기준에 따라 화재시 발생되는 연소특성을 파악하였다. 또한 적외선분광계(FTIR)를 이용하여 시편의 연소로 발생하는 가스중 대표적 독성가스를 측정한 후 기존의 독성모델에 적용하였다. 콘칼로리미터 시험 결과 2종의 시편 모두 복사열 차단장치를 제거하자마자 인화 및 불꽃연소가 시작되어, 화재시 화염의 급속한 전파 요인이 될 수 있음을 확인하였으며, 적외선분광계를 통한 연소가스 분석 결과, 일반적인 연소가스인 이산화탄소와 일산화탄소뿐만 아니라 인체에 심각한 위해를 주는 아크롤레인, 암모니아 및 시안화수소 등이 다량 검출되었다. 본 연구를 통해 폼블럭 제품은 착화성과 발열량이 높으며 유해가스가 다량 방출될 수 있음을 실험을 통해 확인하였다. 따라서 폼불럭 사용에 따른 재료의 연소특성, 즉 착화성 저감, 최대 열방출률 제한 및 주요 유해가스의 농도를 제한하는 기준마련도 시급히 요구된다.

경년열화 기간에 따른 원자력발전소용 비안전등급 케이블의 연소특성 분석 (Combustion Characteristics Analysis of a Non-class 1E Cable for Nuclear Power Plants according to Aging Period)

  • 김민호;이석희;이민철;이상규;이주은
    • 한국안전학회지
    • /
    • 제35권5호
    • /
    • pp.22-29
    • /
    • 2020
  • In this study, combustion and smoke release characteristics of a non-class 1E cable for nuclear power plants were investigated according to aging period. The aging was reproduced through an accelerated aging method for interval of 10 years :10, 20, 30 and 40 year, which was applied the Arrhenius equation. The cable was subjected to accelerated aging. In order to understand combustion and smoke release characteristics, the cone calorimeter test was performed according to the standard code of KS F ISO 5660-1. Heat release rate, mass loss rate, average rate of heat emission and smoke production rate were examined through cone calorimeter test. Fire performance index, fire growth index and smoke factor were derived from test results for the comparison of quantitative fire risk. When comparing the fire performance index and the fire growth index, the early fire risk tends to decrease as aging progresses, which might be attributed from the fact that the volatile substances of cables were evaporated. However, when comparing the heat release rate, average rate of heat emission and mass loss rate, which represent the mid and late periods of the fire risk, the values of accelerated aging cables were much higher than those of non-aged cable, which signifies the unstable formation of the char layer resulted in the change in the performance of flame retardants. In addition, the results from the smoke characteristics show that the accelerated aging cables were lager than the non-aged cables in terms of overall fire risk. These results can be used as baseline data when assessing fire risk of cables and establishing fire safety code for nuclear power plants.

건축용 바닥재의 외부복사열에 의한 화재위험성 비교 연구 (A Study on the Fire Risk Comparison of Building Flooring Materials by External Heat Flux)

  • 박영주;김영탁
    • 한국안전학회지
    • /
    • 제32권5호
    • /
    • pp.20-24
    • /
    • 2017
  • In this study, we have performed the Cone Calorimeter test in accordance with ISO 5660-1 to check the combustion characteristics of building flooring materials. The fire risk of these materials were evaluated by construction code, KFI criteria and standards of flame retardant performance. When samples exposed to external heat flux, all samples consumed a lot of Oxygen for a long time. So heat release from sample burning continued so long. And also all samples produced so much smoke. Even though a few samples were satisfied with only peak heat release rate criteria, all 8 samples were not satisfied with criteria of peak heat release rate and total heat released together. The results of 5 min total heat released were $15.9MJ/m^2{\sim}5.9MJ/m^2$. It menas the results are more than 2~6 times higher than the criteria. The results of 10 min total heat released were $30.1MJ/m^2{\sim}100.8MJ/m^2$. It means the results are more than 3~12 times higher than the criteria. 6 of 8 samples were not satisfied with Dm.corr.(corrected maximum smoke density) criteria. The building flooring materials which we used for this test ignited very fast and the burning continued so long. It means these samples are susceptible to fire.