• Title/Summary/Keyword: ISO 규격

Search Result 451, Processing Time 0.042 seconds

A Study on Improvement of Barrier Free Door Standard (Barrier Free 출입문 규격기준 개선에 관한 연구)

  • Kim, In-Bae;Kim, Won-pil
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.23 no.4
    • /
    • pp.7-15
    • /
    • 2017
  • Purpose: The Korean government has implemented a Barrier Free Certification System since 2008 to create a secure and convenient environment for the socially disadvantaged. The drastic increase in the number of BF-certification facilities is expected due to the revision of the system and increasing the number of certification institutions. An analysis of individual evaluation items needs to be made for the BF-Certification with public confidence. Method: Korean standard, International Standard(ISO/FDIS 21542, 2011), German Standard(DIN 18040-1, 2010), Austrian Standard(${\ddot{O}}NORM$ B 1600, 2017) and Swiss Standard(Norm SIA 500 / SN 521 500, 2009) were investigated and analyzed. A comprehensive improvement plan is proposed by comparing details of the aforementioned standards and the evaluation items of BF-Certification. Results: Many problems arise in applying existing Barrier-free standards due to changes in population structure, environmental change and the use of powered wheelchairs. International standards are being improved to solve these problems. The korean standards also require improving of the Barrier Free Law and Certification System, which reflect these trends. In korean cases, standards such as the size of the doors (width and height), the Unobstructed Manoeuvring Space and Clear Space at the Latch side of the Door are required to improve standards in accordance with international standards. In addition, the expression of laws and evaluation items of BF-Certification should be clearly defined. And the application of visual contrast standards for the enhancement of perceptions presented in international standards should be considered. Implication: Barrier Free related legal standards and evaluation items of BF-Certification that are used in Korea are required to be revised in consideration of social and environmental changes. Comprehensive improvements should be made through detailed review.

A Sturdy on the Deployment Strategy of Communication Environment for Adopting the International Standards between ITS Center and Roadside Equipment (국제 표준에 부합하는 ITS 센터-노변장치간 통신환경 구축 방안 연구)

  • Lee, Sang-Hyun;Son, Seung-Neo;Cho, Yong-Sung;Lee, Choul-Ki
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.11 no.4
    • /
    • pp.34-50
    • /
    • 2012
  • This study set out to define a communication environment between an ITS center and field device required to be introduced in the nation in order to guarantee the interoperability, compatibility, and global competitiveness of communication between them in the nation. It also aimed to establish technical and policy plans for its introduction, develop an emulator for information exchange, and apply VMS by way of showing an example, thus testing its validity. First, a standard environment for information exchange between an ITS center and field device required to be introduced in the nation was defined as a dual protocol between DATEX and SNMP. The study also proposed a message definition system including meta-attribution definition and OID introduction. The study then suggested technical and policy plans for its introduction including securing enough feasibility with feedback through a model project of standard introduction, offering education and promotions for the standard in advance, providing methods to introduce and systematically manage OID, developing a hardware standard proper for the information exchange standard, and setting up an integrated management system to introduce a dual protocol.

Evaluation of the radiopacity and cytotoxicity of resinous root canal sealers (레진계 근관충전실러의 방사선 불투과성 및 세포 독성에 대한 평가)

  • Kim, Chang-Kyu;Ryu, Hyun-Wook;Chang, Hoon-Sang;Lee, Byung-Do;Min, Kyung-San;Hong, Chan-Ui
    • Restorative Dentistry and Endodontics
    • /
    • v.32 no.5
    • /
    • pp.419-425
    • /
    • 2007
  • The aim of this study was to evaluate the radiopacity and cytotoxicity of three resin-based (AH 26, EZ fill and AD Seal), a zinc oxide-eugenol-based (ZOB Seal), and a calcium hydroxide-based (Sealapex) root canal sealers. Specimens, 10 mm in diameter and 1 mm in thickness, were radiographed simultaneously with an aluminum step wedge using occlusal films, according to ISO 6876/2001 standards. Radiographs were digitized, and the radiopacity of sealers was compared to the different thicknesses of the aluminum step wedge, using the Scion image software. Using the 3-(4,5-dimethylthiazol-2-yl)-2,5-diphenyltetrazolium bromide (MTT) assay, the cytotoxicity of each material was determined in immortalized human periodontal ligament (IPDL) cells. The results demonstrated that EZ fill was the most radiopaque sealer, while Sealapex was the least radiopaque (p < 0.05). AH 26, AD Seal and ZOB Seal presented intermediate radiopacity values. All the materials evaluated, except for Sealapex, presented the minimum radiopacity required by ISO standards. The cell viabilities of resin-based root canal sealers were statistically higher than that of other type of root canal sealers through the all experimental time. Further, EZ fill showed statistically lower cell viability in 24 and 48 hours compared to AD Seal and in 72 hours compared to all other resin-based root canal sealers. However, there was no correlation between the radiopacity and cytotoxicity of three resin-based root canals sealers (p > 0.05). These results indicate that resin-based root canal sealer is more biocompatible and has advantage in terms of radiopacity.

Evaluation of Flexural Properties of Indirect Gum-Shade Composite Resin for Esthetic Improvement (심미성 향상을 위한 간접수복용 Gum-Shade 복합레진의 굽힘 특성 평가)

  • Im, Yong-Woon;Hwang, Seong-Sig
    • Journal of dental hygiene science
    • /
    • v.15 no.4
    • /
    • pp.407-412
    • /
    • 2015
  • This study investigated flexural properties of indirect Gum-shade composite resins for esthetic improvement. The material utilized in this study was Crea.lign, Twiny flow and Twiny paste (TP). Ten specimens were fabricated with a dimension of $25{\times}2{\times}2mm$ according to the ISO 4049. After fabrications, specimens were stored in the distilled water for 24 hours at the temperature of $37^{\circ}C$. Three-point bending test was performed in universal testing machine (Instron 3344; Instron, USA) at a crosshead speed of 1 mm/min until the failure occurred. TP exhibited a higher flexural strength (FS) and flexural modulus (FM) compared to the flowable materials. There were significant differences among the three materials in FS and FM. However, there was no significant difference in work of fracture (WOF) in all tested materials (p>0.05). In Weibull analysis, TP showed the greatest Weibull modulus which means a higher reliability of the materials. Also, Gum-shade composite resins revealed a strong correlation in all flexural properties. There was a positive correlation in FS-FM ($r^2=0.99$) and a negative correlation between FS-WOF and FM-WOF ($r^2>0.97$). Therefore, this confirmed that flexural property was important for mechanical behavior evaluation and useful information. To addition, this improved among mechanical properties correlation of materials as important factor.

Implementation of Improved Frame Slotted ALOHA Algorithm for Fast Tag Collection in an Active RFID System (고속 태그 수집을 위한 개선된 능동형 RFID 시스템용 프레임 Slotted ALOHA 알고리즘 구현)

  • Kim, Ji-Tae;Kang, Byeong-Gwon;Lee, Kang-Won
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.39B no.9
    • /
    • pp.598-605
    • /
    • 2014
  • In this paper, we suggest a modified slotted ALOHA algorithm for fast tag collection in active RFID system and implement the reader and tag operation using CC2530 chip of Texas Instruments Co. to prove the performance of the proposed algorithm. In the present international standard related with active RFID including ISO/IEC 18000-7 the reader sends sleep command to each tag after successful obtaining tag's information. Meanwhile, in this paper, the tags decide to sleep after checking the second command from the reader resulting in enormously decreased tag collection time. We tested the proposed algorithm with 30 tags over the range of 0-3m and the results showed that the tag collection process was completed in 400msec at average. And 30 tags are collected in one second with 99.7% and the collection rate is 100% in 2m distance between reader and tag. The collection rates are 99.94% and 99.7% for distance 2.5m and 3m, respectively. The average collection rate is 99.91% over all range and it is concluded that the proposed algorithm is enough to apply to real fields.

A Study for Application of Standard and Performance Test According to Purpose and Subject of Respiratory Medical Device (호흡보조의료기기의 사용목적 및 대상에 따른 규격적용 방안 및 성능에 관한 연구)

  • Park, Junhyun;Ho, YeJi;Lee, Duck Hee;Choi, Jaesoon
    • Journal of Biomedical Engineering Research
    • /
    • v.40 no.5
    • /
    • pp.215-221
    • /
    • 2019
  • The respiratory medical device is a medical device that delivers optimal oxygen or a certain amount of humidification to a patient by delivering artificial respiration to a patient through a machine when the patient has lost the ability to breathe spontaneously. These include respirators for use in chronic obstructive pulmonary disease and anesthesia or emergency situations, and positive airway pressure devices for treating sleep apnea, and as the population of COPD (chronic obstructive pulmonary disease) and elderly people worldwide surge, the market for the respiratory medical devices it is getting bigger. As the demand for both airway pressure devices, there is a problem that the ventilator standard is applied because the reference standard has not been established. Therefore, the boundaries between the items are blurred due to the purpose, intended use, and method of use overlapping similar items in a respiratory medical device. In addition, for both airway pressure devices, there is a problem that the ventilator standard is applied because the reference standard has not been established. Therefore, in this study, we propose clear classification criteria for the respiratory medical devices according to the purpose, intended use, and method of use and provide safety and performance evaluation guidelines for those items to help quality control of the medical devices. And to contribute to the rapid regulating and improvement of public health. This study investigated the safety and performance test methods through the principles of the respiratory medical device, national and international standards, domestic and international licensing status, and related literature surveys. The results of this study are derived from the safety and performance test items in the individual ventilator(ISO 80601-2-72), the International Standard for positive airway pressure device (ISO 80601-2-70), The safety and performance of humidifiers (ISO 80601-2-74) and the safety evaluation items related to home healthcare environment (IEC 60601-1-11), In addition, after reviewing the guidelines drawn up through expert consultation bodies including manufacturers and importers, certified test inspection institutions, academia, etc., the final guidelines were established through revision and supplementation. Therefore, in this study, we propose guidelines for evaluating the safety and performance of the respiratory medical device in accordance with growing technology development.

Reviewing the Operation of the Navy Safety Management System and Its Direction (해군 안전관리체계 운영에 대한 검토 및 발전 방향 고찰)

  • Jeongwoo Han;Kijae Kim;Wonyoung Lee;Kyoshik Park
    • Journal of the Society of Disaster Information
    • /
    • v.19 no.4
    • /
    • pp.859-868
    • /
    • 2023
  • Purpose: In order to enhance safety, the Korea Navy is making efforts to introduce a safety and health management system and to develop a risk assessment system, while safety accidents keeps occurring. A development plan was proposed through an inspection of the Safety Management System(SMS). Method: To diagnose the Korea Navy's safety management system, changes in the safety environment, documentation system, and safety and health management system operation were reviewed, points to be improved were found, and improvement directions were derived. Result: There is a need for an SMS standard that can present the Korea Navy's safety policy and safety management direction, and a safety program that provides guidelines for implementing it in a standardized manner. To this end, we were able to confirm the feasibility of linking the requirements of the US Navy's SMS and the international standard ISO 45001 standard together with the Korea Navy's safety management system. Conclusion: The Korea Navy's safety management system needs to clearly present safety policies and standards, and have public confidence and effectiveness in safety work through a standard program that can implement them, and for this, the development of a Navy SMS is necessary.

자동차 전자파

  • 성현수;신승현;문진동;한종철
    • The Proceeding of the Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.5 no.4
    • /
    • pp.83-93
    • /
    • 1994
  • 1886년 고트리브 다이믈러와 칼 벤즈가 가솔린 자동차를 개발한 이후 100여년이 지난 지금 자동차는 비약적으로 진보, 발전하여 현대 산업사회와 개인의 생활에 있어 산업운송수단과 이동수단으 로서 필요불가결하게 되어 밀접한 관계를 갖고 있다. 우리나라 자동차 공업의 역사는 자동차가 사회적, 경제적 효용에 따라 그 생산과 보유대수가 날이 갈수록 증가 일로에 있으며, 자동차의 생산대수는 전세 계에서 년간 약 50,606천대('94년)로서 중요한 국가 기간 산업으로 자리하고 있다. 한편 전기, 전자공업의 발전에 따른 자동차의 Car Electronics가 많이 채용되게 됨에 따라 현재의 자 동차에는 대부분이 전자제어 System으로 구성되어 있다. 최근에는 Micro Processor를 이용한 전자부품이 많이 사용되어 전자파에 대한 문제가 다양하게 발생 하고 있다. 예를 들면 미국 캘리포니아주에서 전자점화제어장치와 연료분사 장치를 설치한 구미의 자동 차가 주행중 28MHz, 28W의 아마추어 무선을 탑제한 자동차가 통과할 때 엔진이 고르지 못한 보고가 있 었고, 화학섬유로된 옷을 착용한 전자부품이 다른 부품에 영향을 주는 사례가 맣아지고 있다. 따라서 자동차에는 여러가지의 전장품, 전자기기를 탑재하기 때문에 자동차 자체에서 발생하는 것과 외부로 부터 받는 전자장해 EMI(Electromagnetic Interference), EMS(Electromagnetic Susceptibility) 가 문제로 되어 자동차 및 부품 maker에 의한 EMC(Electromagnetic Compatibility) 평가의 중요성이 고조되고 있다. 차제무전기, 차제무전기, Car-Radio는잡음방해를 많이 받기도 하지만, 잡음원이 되기 도 한다. 또한 Engine 제어, 차속제어, Brake 제어등에 이용되는 전자제품은 방해에 의한 오동작 또는 파괴가 발생하여 주행기능, 안전성에 문제가 야기되지 않도록 해야 한다. 이러한 전자기 환경은 모두 RF(Radio Frequence)와 자동차에서의 전자파 장해 문제의 원이 될 수 있다. 자동차 및 그 부품의 전자기 방해에 관한 규격화는 1987년부터 괄목할 만하게 진행되어 이에 따른 규제 움직임이 IEC(International Electrotechnical Commission: 국제전기기술위원회) 산하의 하부기 구인 CISPR(International Special Committeeon Radio Interference: 국제 무선 장해 특별위원회)가 전자기 방해파에 대한 측정법 통일안을 제안 하였고, ISO(International Standardization Organiza- tion: 국제표준화 기구) 가운데 TC 22/SC3가 자동차의 전장품에 대한 장해를 논의히고 있다. 특히, 자동차의 EMC에 관한 국가 규격은 국제 규격에서 저술한 바와 같이 특별히 규정된 것이 없고 VDE(Verband Deutscher Elektrotechniker: 서독전기기술 협회)와 SAE(Society of Automotive Engi- neers: 자동차 기술자 협회)에서 비교적 활발하고 Jaso(Japanese Automobile Standards Organization: 일본 자동차 표준협회)에서 많이 진행중에 있다. 본 고에서는 자동차의 전자제어에 따른 잡음 발생 요인과 전자파 간섭 관련 자동차 규격과 시험평가 방법에 대해 간단히 소개 하였다.

  • PDF

Design of an authentication protocol for secure electronic seals (안전한 전자봉인을 위한 인증 프로토콜 설계)

  • Park Seongsoo;Lee Mun-Kyu;Kim Dong Kyue;Park Kunsoo;Kim Howon;Chung Kyoil
    • Proceedings of the Korean Information Science Society Conference
    • /
    • 2005.11a
    • /
    • pp.982-984
    • /
    • 2005
  • 최근 국제물류에서 화물 컨테이너의 운송을 보다 안전하고 효율적으로 관리하기 위하여 수출입절차 규제가 강화되고, 도난, 밀매, 테러 등의 범죄를 예방하기 위한 새로운 정책과 기술이 도입되고 있다. 특히, 빠르게 실용화가 진행되고 있는, RFID 기술을 사용한 무선인식 전자봉인(e-seal)은 기존의 기계적 봉인장치를 대체함으로써 컨테이너 운송의 안전성을 보장하고, 선적 및 하선 절차의 효율을 높인다. 수년간 e-seal의 ISO 국제표준화가 진행되어 왔으며. 최근 e-seal의 데이터 보호에 대한 표준화가 진행 중이다. 본 논문에서는 e-seal의 실질적인 사용 환경과 기존의 명령어 표준규격을 고려하여 안전한 e-seal을 위한 새로운 명령어들을 설계하고 EAP를 응용하여 e-seal과 리더기간의 상호 인증 프로토콜을 제시한다. 그리고 이를 다시 효율적으로 개선하여 e-seal에 적합한 상호 인증 프로토콜을 제시한다.

  • PDF

A performance study and IC implementation of high-speed distributed-multimedia shared medium access control protocol(part II:integrated circuit design for HCR protocol) (고속 분산 멀티미디어 서비스를 위한 공유매체 접속제어 프로토콜의 성능분석 및 집적회로 구현 (II부:HCR 프로토콜용 집적회로 설계))

  • 강선무;이종필;송호준;김대영
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.22 no.10
    • /
    • pp.2282-2291
    • /
    • 1997
  • This paper describes an IC design for the HCR protocol which is designed to accomodata both real and non-real time data for high-speed multimedia services. The designed HCR IC is perfectly compatible with the conventional ATM IC's and physical layer IC's. The standard UTOPIA interface is adopted. Simulation results show that the proposed HCR IC operates very well according to the priority and the quota state of the real and non-real time data. The proposed HCR IC can be merged into the conventional ATM IC's without any modification and will be useful for multimedia service applications.

  • PDF