• Title/Summary/Keyword: IS6110

Search Result 531, Processing Time 0.026 seconds

A Study on Performance Test and Fabrication of Vacuum Glazing with Numerical Analysis (수치해석을 통한 진공유리 제작 및 성능실험에 관한 연구)

  • Hwang, Il Sun;Lee, Young Lim
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.25 no.6
    • /
    • pp.303-309
    • /
    • 2013
  • For air-tight modern buildings, secondary damage is likely to occur due to condensation in the relatively high heat-transmission windows since water vapor is not easy to discharge. Therefore, in this study, condensation performance of vacuum glazing was numerically analysed, compared with that of ordinary glass and confirmed experimentally by three sheets of vacuum glazing manufactured. The results show that the heat transmission coefficient of the vacuum glazing whose internal pressure is $10^{-3}$ torr was as low as about $5.7W/m^2{\cdot}K$. Thus, the condensation performance as well as the adiabatic performance was greatly improved compared to that of the ordinary glass.

LCC Analysis of Residential Dehumidifying Air Conditioning System using Thin Separation Membrane (분리막을 이용한 주거용 제습공조시스템의 LCC 분석)

  • Jung, Yong-Ho;Park, Seong-Ryong
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.30 no.1
    • /
    • pp.10-16
    • /
    • 2018
  • The climate of summer in Korea is quite hot and humid. Many studies have been carried out to reduce the energy required for operating a dehumidifier. The dehumidifier is mainly connected to the cooling system since it operates in the summer. Conventional dehumidification methods often require additional cooling and energy for dehumidification. In this study, a system for increasing the efficiency by applying a membrane was analyzed. Its energy saving effect was analyzed when it was applied to residential buildings. Economic efficiency was also evaluated. As a result of this study, 9.0% energy savings were achieved for residential buildings. The investment recovery period was 28.9 years. Such long investment recovery period was because the initial investment cost was excessive and annual energy saving only appeared in the summer.

Feasibility of the Defrost Control by Photoelectric Technology via Comparison with the Temperature Differential Defrosting Method (온도차 감지 제상법과의 비교를 통한 광센서 제상법의 타당성 검증을 위한 연구)

  • Jeon, Chang-Duk;Kim, Dong-Seon
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.26 no.9
    • /
    • pp.434-440
    • /
    • 2014
  • Experiments were performed to verify if performance and characteristic curves obtained from the temperature differential defrosting method, where surface temperature is measured to judge defrosting condition, can be reproduced by the photoelectric technology where defrosting condition is judged by photoelectric sensors. The output voltage of a phototransistor and heating capacity, power consumption, and surface temperature of the outdoor heat exchanger are compared. The results showed that the photoelectric sensors can be used as a defrost control device. On-off control timings in temperature differential defrosting method are in good agreement with those predicted by the high and low threshold output voltages of the photoelectric sensor.

Improvement Plan of Mechanical System in Construction Industry Production Process (기계설비산업의 생산체계 선진화방안)

  • Park, Jong-Il;Park, Ryul
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.23 no.6
    • /
    • pp.470-476
    • /
    • 2011
  • The aim of this paper is improvement plan of mechanical field construct production system in Korea construction industry market. Recently Korea's construction production system is changing rapidly. While change, mechanical system construction field must prepare proper system for construction production system and later mechanical construction work will give order directly. Through this study the author will show the improved mechanical field construct production system and it can useful future construction industry production system in Korea.

Experimental Study of the Relationship between Weight Variation and Thermal Conductivity in Polyurethane Foam (단열재의 무게변화와 열전도도와의 상관관계에 관한 실험적 연구)

  • Lee, Hyo-Jin
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.27 no.5
    • /
    • pp.241-246
    • /
    • 2015
  • Cellular foamed insulation such as polyurethane foam ages and degrades the thermal conductivity. Aging of foam is a result from the diffusion of gases, initially consisting of $CO_2$ but eventually replaced by air from the environment. The variation of the cell gas content with time is primarily influenced by the increase of thermal conductivity of the cellular foam. The weight of foam also changes as the gas diffuses and exchanges. In this study, a weight measurement method has been proposed to evaluate the effective diffusion coefficients of $CO_2$ and Air, $D_{CO2}=7.08504E-11$ and $D_{air}=4.86086E-12$, respectively and are compared with the gas analysis method.

The Evaluation of Work Noise in Tunnel under Construction (터널 내 작업소음 평가)

  • Yun, Chang-Yeon
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.26 no.3
    • /
    • pp.103-107
    • /
    • 2014
  • To assess a various of workplace noise environment in the tunnel construction site, the measurement is performed while tunnel constructing work. This study focuses on the sound attenuation according to the sound frequency characteristics and the distance from various works in the tunnel. Also, the noise distribution while blasting work is measured according to distance in this study. In addition, the boring processing, muck treatment, and tunnel lining by distance are measured for the noise distributions.

A Study for Optimization the Ventilation Performance of the Computer Room (전산실의 환기성능 최적화를 위한 연구)

  • Kwon, Yong-Il
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.27 no.2
    • /
    • pp.57-62
    • /
    • 2015
  • The objective of the present study is to identify the ventilation problems and to suggest the optimal ventilation system to save energy and to improve IAQ in the computer rooms, which annually performs the cooling operation by the server with the highly thermal load. Numerical results on the temperature and local mean age are presented along with some of the discharge velocities. Results show many interesting aspects of airflow patterns affecting the ventilation performances, according to the discharge velocity of the supply diffuser installed in the bottom surfaces between the servers. As the results, 2.5 m/s of the optimal discharge velocity is needed in order to improve the ventilation performance.

Heat Transfer Characteristics of Heat Exchange Module for a Water Tube Type Modular Boiler (모듈형 수관식 보일러를 위한 열교환 모듈의 열전달 특성)

  • Ahn, Joon;Kim, Jong-Jin;Kang, Sae-Byul
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.24 no.3
    • /
    • pp.265-270
    • /
    • 2012
  • A finned tube type heat exchange module has been proposed for a multi-burner water tube boiler. Fin density and length increase in streamwise direction to equalize the evaporation for each module, which makes it difficult to apply conventional bulk design procedure. The design program has been improved by updating data for every row of tubes along the flow. A numerical simulation has been also conducted to evaluate the effect of inlet conditions and validated with experiment. The heat transfer of the first row has been underpredicted by the conventional Zhukauskas correlation, since the acceleration of the flow due to the blockage is not fully inflected. The fin tip temperature is also underpredicted by Bessel solution, because of the interaction with neighboring fins.

A Study on Correlation of Outdoor Environmental Condition about Cooling Load (냉방부하에 영향을 미치는 외기 환경조건의 상관관계에 관한 연구)

  • Lee, Je-Myo
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.24 no.11
    • /
    • pp.759-766
    • /
    • 2012
  • To estimate the cooling load for the following day, outdoor temperature and humidity are needed in hourly base. But the meteorological administration forecasts only maximum and minimum temperature. New methodology is proposed for predicting hourly outdoor temperature and humidity by using the forecasted maximum and minimum temperature. The correlations for normalized outdoor temperature and specific humidity has been derived from the weather data for five years at Seoul, Daejeon and Pusan. The correlations for normalized temperature are independent of date, while the correlations for specific humidity are linearly dependent on date. The predicted results show fairly good agreement with the measured data. The prediction program is also developed for hourly outdoor dry bulb temperature, specific humidity, dew point, relative humidity, enthalpy and specific volume.

Thermal Structural Analysis of Steam Trap Bimetal Valve (스팀 트랩 바이메탈 밸브의 열 구조해석)

  • Kim, Dong Hwan;Kim, Dong Hyun;Ryu, Gyeong Joong
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.24 no.11
    • /
    • pp.799-805
    • /
    • 2012
  • In this study, structural thermal analyses for steam trap valve considering contact boundary condition have been conducted for high temperature and pressure conditions using nonlinear finite element method. Full steam trap model also including regulator and housing structures is considered in order to accurately simulate the complex valve mechanism and investigate thermal stress levels, and structural behaviors of core structural parts. It is typically shown that the present computational approach can give very useful results for design engineers so that the operating performance and structural safety of the steam trap valve can be verified in the design process.