• 제목/요약/키워드: IS6110

검색결과 531건 처리시간 0.027초

바닥면이 움직이는 이차원 채널 내 액적의 특성 연구 (Study on Characteristics of a Droplet in Two-dimensional Channel with Moving Bottom Wall)

  • 김형락;윤현식;정해권;하만영
    • 설비공학논문집
    • /
    • 제23권2호
    • /
    • pp.103-110
    • /
    • 2011
  • A two-dimensional immiscible droplet deformation phenomena on moving wall in a channel has been investigated by using lattice Boltzmann method involving two-phase model. The dependence of the deformation of the droplet with different sizes on the contact angle and the velocity of bottom wall has studied. When the bottom wall starts to move, the deformation of the droplet occurs. For the largest bottom wall velocity, eventually, the deformation of the droplet is classified into the three patterns according to the contact angle.

관 단면형상 변화에 따른 열전달 특성에 관한 수치해석적 연구 (Numerical Study for Heat Transfer Characteristics Varying Cross-Sectional Shape of a Tube)

  • 박훈채;최항석;김석준
    • 설비공학논문집
    • /
    • 제24권7호
    • /
    • pp.560-566
    • /
    • 2012
  • Numerical study has been carried out to investigate heat transfer and pressure drop characteristics for streamlined shape tubes. The flow and thermal fields are investigated with varying diameter ratio of the tube ranging from 0.4 to 2.5 and Reynolds number ranging from 10,000 to 30,000. The results show that heat transfer per unit fan power is maximum at $D_2/D_1=0.8$. Furthermore, the heat transfer per unit fan power of streamlined shape tubes was compared with circular tube. The heat transfer per unit fan power of streamlined shape tube was larger than that of circular tube.

공동주택 바닥복사 난방시스템의 GRNN 제어 적용에 관한 연구 (A Study on GRNN Control Strategies for Floor Radiant Heating System in Residential Apartments)

  • 송재엽;안병천
    • 설비공학논문집
    • /
    • 제24권12호
    • /
    • pp.830-836
    • /
    • 2012
  • In this study, the effects of heating control methods on heating control performance and energy consumption in the floor radiant heating control system of residential apartments were research by computer simulation. A general regression neural network(GRNN) control method for reducing indoor temperature overshoot and saving energy in floor radiant heating system is suggested. The GRNN control method shows good responses in comparison with the conventional and outdoor reset control methods for improving indoor thermal environment and reducing energy consumption.

로터리 제습기의 일반 해석 모델 (Development of a General Analytical Model for Desiccant Wheels)

  • 김동선;이대영
    • 설비공학논문집
    • /
    • 제25권2호
    • /
    • pp.109-118
    • /
    • 2013
  • The absence of a simple and general analytical model has been a problem in the design and analysis of desiccant-assisted air-conditioning systems. In this study, such an analytical model has been developed based on the approximate integral solution of the coupled transient ordinary differential equations for the heat and mass transfer processes in a desiccant wheel. It turned out that the initial conditions should be determined by the solution of four linear algebraic equations including the heat and mass transfer equations for the air flow as well as the energy and mass conservation equations for the desiccant bed. It is also shown that time-averaged exit air temperature and humidity relations could be given in terms of the heat and mass transfer effectiveness.

MSP 기법을 적용한 고분자 전해질 연료전지 가스확산층의 포로시메트리 연구 (Porometric Study on the Gas Diffusion Layer in PEMFCs Using Method of Standard Porosimetry)

  • 이용택
    • 설비공학논문집
    • /
    • 제25권2호
    • /
    • pp.64-69
    • /
    • 2013
  • The structure of pore network of gas diffusion layers (GDLs) in PEMFCs plays a critical role in determining the transport phenomena of reaction gas as well as generated water. In addition, the interactive characteristics between water and surface of pore are no less important than the structural characteristics of pore network. In this study, porometric investigation is conducted for two kinds of GDL using method of standard porosimetry which enable to distinguish hydrophobic pores from hydrophilic pores of GDLs. The porosity of TGPH-120 decreases by 6% by adding 30 wt.% of PTFE, but the porosity of hydrophilic pores decreases by 12%. The relation of $p_c-S_{nw}$ varies with the addition of PTFE, especially at low $p_c$.

금속소재의 고변형률 영역 유동응력선도 평가 (Evaluation of Flow Stress of Metal up to High Strain)

  • 이상곤;이인규;이성윤;이성민;정명식
    • 소성∙가공
    • /
    • 제29권6호
    • /
    • pp.316-322
    • /
    • 2020
  • The flow stress curve is usually determined via uniaxial tensile or simple compression test. However, the flow stress curve up to high strain cannot be obtained using these two tests. This study presents a simple method for obtaining the flow stress curve up to high strain via FE analysis, a simple compression test, and an indentation test. In order to draw the flow stress curve up to high strain, the indentation test was carried out with the pre-stained specimen using the simple compression test. The flow stress curve of Al6110 was evaluated up to high strain using the proposed method, and the result was compared with the flow stress curve of the uniaxial tensile test of the initial material.

가스터빈 열병합발전소 성능저하 분석에 관한 연구 (A Study on Performance Degradation Analysis of Gas Turbine Combined Heat and Power Plant)

  • 김홍주;김병헌;오병수
    • 설비공학논문집
    • /
    • 제28권6호
    • /
    • pp.248-255
    • /
    • 2016
  • In this study, the degree of performance changes between the guaranteed performance and the performance after a certain operating start time is calculated by using the performance test of gas turbine CHP. The reason of the performance degradation will then be analysed. For some results of the CHP plant performance tests the comprehensive electric power output was 8,380 kW lower than the guaranteed performance, and the gas turbine's output was reduced to about 250 kW whenever ambient temperatures rose to $1^{\circ}C$. Also, causes of the performance degradation of gas turbines are ambient temperature rise, temperature aging and air compressor's efficiency drop.

주거용 건물 지열원 멀티 히트펌프시스템의 지열순환펌프 가변유량제어에 관한 실증연구 (An Experimental Study on Variable-Speed Control of an Ground-Water Circulation Pump for a Ground Source Multi-Heat Pump System)

  • 송수원
    • 설비공학논문집
    • /
    • 제25권8호
    • /
    • pp.443-449
    • /
    • 2013
  • The purpose of this study is to propose an enhanced variable-speed control method of ground-water circulation pumps using inlet and outlet ground-water temperature difference and analyze its effect for the ground source multi-heat pump system installed in a single-family house. As a result, it has shown to significantly reduce the electricity use of ground-water circulation pump and improve overall system Coefficient of Performance (COP) due to the proposed variable-speed control under partial load conditions after oversized and inefficient single-speed pump retrofit.

Polymerase Chain Reaction (PCR)을 이용한 결핵의 진단에 관한 연구 (Application of Polymerase Chain Reaction (PCR) to the Diagnosis of Tuberculosis)

  • 김호중;김영환;한성구;심영수;김건열;한용철
    • Tuberculosis and Respiratory Diseases
    • /
    • 제39권6호
    • /
    • pp.517-525
    • /
    • 1992
  • 연구배경 : 1985년 Saiki등에 의해, 특정한 DNA를 연속적으로 복제할 수 있는 방법인 polymerase chain reaction (PCR)이 개발된 이래, PCR은 검체내에 극미량으로 존재하고 있는 병원체의 진단에 큰 도움을 줄 것으로 기대되었다. 결핵균의 진단방법중, 도말염색 방법은 감수성이 낮아서 문제가 되고 있으며, 배양은 감수성은 높으나 기간이 오래 걸려서 임상적으로 도움을 주지 못하는 경우가 많다. 이에 저자들은 Mycobacterium tuberculosis의 특이 단백질인 65 kD mycobacterial antigen을 encoding하는 2520 base pair DNA중, 383 base pair DNA를 이용한 PCR과 IS6110 fragment의 일부인 123 base pair DNA를 이용한 PCR을 시행하여, 이의 감수성과 특이도를 알아보고 폐결핵 환자의 객담을 검체로한 결핵의 조기진단 방법을 개발하고자 하였다. 방법 : M. tuberculosis (H37Rv, H37Ra), M. avium, M. intracellulare, M. scrofulaceum 균주와 환자의 객담에서 DNA를 추출하여, 383 base pair DNA 양끝의 20 base pair DNA primer (TB-1, -2)와 IS6110 fragment 일부의 DNA 양끝의 20 base pair DNA primer (Sal I-1, -2) 로 PCR을 시행하였으며, 전기 영동후 자외선 발광으로 확인하였다. 결과 : 1) Ethidium bromide 염색후 발광경하에서, Mycobacterium tuberculosis (H37Rv, H37Ra)와 Mycobacterium bovis는 TB-1, -2 primer와 Sal I-1, -2 primer를 이용한 PCR에서 모두 양성을 보였고 Mycobacter intracellulare와 Mycobacterium scrofulaceum은 TB-1, -2 primer를 이용한 PCR에서만 양성을 보였다. 2) Southern Blot 분석에는 두쌍의 primer 모두에서 Mycobacterium tuberculosis (H37Rv, H37Ra)와 Mycobactgerium bovis만이 양성을 나타내었으며 Mycobacterium intracellulare 와 Mycobacterium scrofulaceum은 음성을 나타내었다. 3) Mycobacterium tuberculosis (H37Rv)를 순차적으로 희석하여 시행한 PCR에서 두쌍의 primer 모두에서 Mycobacterium 균 1개체에 해 당되는 1 fg DNA까지 양성을 나타내었다. 4) 임상적으로 진단받은 결핵환자의 시행한, Sal I-1, -2 primer를 이용한 PCR에서 도말 검경 양성군의 객담 29예중 28예인 96.6%에서 양성을 나타내었으며, 도말 정경 음성-배양 양성군에서는 5예중 4예(80.0%), 그리고 도말 검경 음성-배양 음성군에서는 26예중 6예(23.1%)가 양성을 나타내었고 음성 대조군 검체 16예에서 2예(12.5%)에서 양성을 나타내였다. 결론 : 이상의 결과로, PCR은 객담에서의 결핵균의 진단에 있어, 배양과 견줄 수 있는 특이도와 예민도를 보이고 있어, 특정한 경우 진단에 도움을 줄 수 있을 것으로 기대되며, 추후 방법의 개선을 위한 연구가 계속 필요할 것으로 사료된다.

  • PDF

초고층 건물 아트리움 공간에서의 제연구획에 따른 시뮬레이션 연구 (Simulation Study of Smoke Control Accordance with Zoning in the Atrium Space of High-rise Buildings)

  • 류형규;배상환;이병석
    • 설비공학논문집
    • /
    • 제26권7호
    • /
    • pp.335-342
    • /
    • 2014
  • The big issue in fire and life safety protection in atriums is that hot smoke can spread vertically via the atrium openings, and impact atrium floors remote from the fire. Three different strategies to provide fire and life safety protection for atrium space were evaluated in this study, using the FDS model. Strategy A is the atrium protection approach addressed in the Korean Building Fire Protection Code, where atria are required to be enclosed with fire shutters from the $2^{nd}$ floor to the atrium top, and the ground floor is allowed to open to the atrium; in this case, no smoke control is required. Strategy B is the atrium protection approach, with smoke control provided in accordance with NFPA 92B; in this case, no atrium floor is enclosed. Strategy C is the atrium protection approach, in which some of the upper atrium floors are enclosed (the case of the top atrium floor being enclosed is evaluated in this study), and atrium smoke control is also provided to protect the lower atrium floors.