• Title/Summary/Keyword: IR-29

Search Result 376, Processing Time 0.026 seconds

A Study on High Speed Laser Welding by using Scanner and Industrial Robot (스캐너와 산업용 로봇을 이용한 고속 레이저 용접에 관한 연구)

  • Kang, Hee-Shin;Suh, Jeong;Kim, Jong-Su;Kim, Jeng-O;Cho, Taik-Dong
    • Proceedings of the KWS Conference
    • /
    • 2009.11a
    • /
    • pp.29-29
    • /
    • 2009
  • On this research, laser welding technology for manufacturing automobile body is studied. Laser welding technology is one of the important technologies used in the manufacturing of lighter, safer automotive bodies at a high level of productivity; the leading automotive manufacturers have replaced spot welding with laser welding in the process of car body assembly. Korean auto manufacturers are developing and applying the laser welding technology using a high output power Nd:YAG laser and a 6-axes industrial robot. On the other hand, the robot-based remote laser welding system was equipped with a long focal laser scanner system in robotic end effect. Laser system, robot system, and scanner system are used for realizing the high speed laser welding system. The remote laser welding system and industrial robotic system are used to consist of robot-based remote laser welding system. The robot-based remote laser welding system is flexible and able to improve laser welding speed compared with traditional welding as spot welding and laser welding. The robot-based remote laser systems used in this study were Trumpf's 4kW Nd:YAG laser (HL4006D) and IPG's 1.6kW Fiber laser (YLR-1600), while the robot systems were of ABB's IRB6400R (payload:120kg) and Hyundai Heavy Industry's HX130-02 (payload:130kg). In addition, a study of quality evaluation and monitoring technology for the remote laser welding was conducted. The welding joints of steel plate and steel plate coated with zinc were butt and lapped joints. The quality testing of the laser welding was conducted by observing the shape of the beads on the plate and the cross-section of the welded parts, analyzing the results of mechanical tension test, and monitoring the plasma intensity and temperature by using UV and IR detectors. Over the past years, Trumf's 4kW Nd:YAG laser and ABB's IRB6400R robot system was used. Nowadays, the new laser source, robot and laser scanner system are used to increase the processing speed and to improve the efficiency of processes. This paper proposes the robot-based remote laser welding system as a means of resolving the limited welding speed and accuracy of conventional laser welding systems.

  • PDF

Electrochemical Analysis of CuxCo3-xO4 Catalyst for Oxygen Evolution Reaction Prepared by Sol-Gel Method (Sol-Gel법을 이용한 CuxCo3-xO4 산소 발생 촉매의 합성 및 전기화학 특성 분석)

  • Park, Yoo Sei;Jung, Changwook;Kim, Chiho;Koo, Taewoo;Seok, Changgyu;Kwon, Ilyeong;Kim, Yangdo
    • Korean Journal of Materials Research
    • /
    • v.29 no.2
    • /
    • pp.92-96
    • /
    • 2019
  • Transition metal oxide is widely used as a water electrolysis catalyst to substitute for a noble metal catalyst such as $IrO_2$ and $RuO_2$. In this study, the sol-gel method is used to synthesize the $Cu_xCo_{3-x}O_4$ catalyst for the oxygen evolution reaction (OER),. The CuxCo3-xO4 is synthesized at various calcination temperatures from $250^{\circ}C$ to $400^{\circ}C$ for 4 h. The $Cu_xCo_{3-x}O_4$ synthesized at $300^{\circ}C$ has a perfect spinel structure without residues of the precursor and secondary phases, such as CuO. The particle size of $Cu_xCo_{3-x}O_4$ increases with an increase in calcination temperature. Amongst all the samples studied, $Cu_xCo_{3-x}O_4$, which is synthesized at 300?, has the highest activity for the OER. Its onset potential for the OER is 370 mV and the overpotential at $10mA/cm^2$ is 438 mV. The tafel slope of $Cu_xCo_{3-x}O_4$ synthesized at $300^{\circ}C$ has a low value of 58 mV/dec. These results are mainly explained by the increase in the available active surface area of the $Cu_xCo_{3-x}O_4$ catalyst.

Nickel Catalysts Supported on Ash-Free Coal for Steam Reforming of Toluene (무회분탄에 분산된 니켈 촉매의 톨루엔 수증기 개질)

  • PRISCILLA, LIA;KIM, SOOHYUN;YOO, JIHO;CHOI, HOKYUNG;RHIM, YOUNGJOON;LIM, JEONGHWAN;KIM, SANGDO;CHUN, DONGHYUK;LEE, SIHYUN
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.29 no.6
    • /
    • pp.559-569
    • /
    • 2018
  • Catalytic supports made of carbon have many advantages, such as high coking resistance, tailorable pore and surface structures, and ease of recycling of waste catalysts. Moreover, they do not require pre-reduction. In this study, ash-free coal (AFC) was obtained by the thermal extraction of carbonaceous components from raw coal and its performance as a carbon catalytic support was compared with that of well-known activated carbon (AC). Nickel was dispersed on the carbon supports and the resulting catalysts were applied to the steam reforming of toluene (SRT), a model compound of biomass tar. Interestingly, nickel catalysts dispersed on AFC, which has a very small surface area (${\sim}0.13m^2/g$), showed higher activity than those dispersed on AC, which has a large surface area ($1,173A/cm^2$). X-ray diffraction (XRD) analysis showed that the particle size of nickel deposited on AFC was smaller than that deposited on AC, with the average values on AFC ${\approx}11nm$ and on AC ${\approx}23nm$. This proved that heteroatomic functional groups in AFC, such as carboxyls, can provide ion-exchange or adsorption sites for the nano-scale dispersion of nickel. In addition, the pore structure, surface morphology, chemical composition, and chemical state of the prepared catalysts were analyzed using Brunauer-Emmett-Taylor (BET) analysis, transmission electron microscopy (TEM), scanning electron microscopy (SEM), x-ray diffraction (XRD), Fourier-transform infrared (FT-IR) spectroscopy, and temperature-programmed reduction (TPR).

Application of PLA/PBAT Composite Films Containing Calcined Oyster Shell Powder for Antimicrobial Packaging (소성 처리된 굴 패각을 활용한 PLA/PBAT 복합필름의 항균 포장재 적용 연구)

  • Yena Oh;Kitae Park;Jongchul Seo
    • KOREAN JOURNAL OF PACKAGING SCIENCE & TECHNOLOGY
    • /
    • v.29 no.2
    • /
    • pp.79-86
    • /
    • 2023
  • In this study, poly(lactic acid) (PLA) and Poly(butylene-adipate-co-terephthalate) (PBAT) composite films containing calcined oyster shell powder (OSP) were evaluated for the applicability of antimicrobial packaging. PLA/PBAT-OSP composite films were prepared using twin-screw extruder. The OSP composite was incorporated into PLA/PBAT blend with different ratios (0, 1, 3, 5 and 10%) and the effect of OSP in the PLA/PBAT matrix was evaluated. The PLA/PBAT-OSP composite films were evaluated for properties using FT-IR, SEM, TGA, DSC, UTM, UV-vis, and Contact angle, as well as antimicrobial property was examined according to ISO 22196 - Antimicrobial Plastic Test. As OSP was added, it showed high antimicrobial activities for both Gram-positive (Staphylococcus aureus) and Gram-negative (Escherichia coli) bacteria. On the other hand, it was found that mechanical properties decreased as OSP was added. For the application of PLA/PBAT-OSP composite films as an antimicrobial packaging material, it is necessary to improve the dispersibility of OSP in the PLA/PBAT composite films and their physical properties at the same time.

Properties of the High and Low Molecule of the Proteoglycan Extracted from Ganoderma lucidum IY009 (Ganoderma lucidum IY009 배양균사체 유래 단백다당류의 저분자와 고분자 분획의 특성)

  • Baek, Seong-Jin;Kim, Yong-Seuk;Chun, Uck-Han;Lee, Eun-Sook;Lee, June-Woo
    • The Korean Journal of Mycology
    • /
    • v.29 no.1
    • /
    • pp.1-8
    • /
    • 2001
  • To examine the structural properties of the proteoglycan (GMPG, Ganoderma lucidum mycelial proteoglycan) obtained from mycelia in Ganoderma lucidum IY009, we obtained the low and high molecular proteoglycan by ultrafiltration and sepharose CL-4B column chromatography. The physicochemical properties of these fractions were as follows. When the proteoglycan separated by ultrafiltration and sepharose CL-4B column chromatography, its was not fractionated completely. The molecular weight of high molecular proteoglycan by the gel column chromatography (CH) was 250 kD and 2,000 kD, and low molecular proteoglycan was 12kD. The total carbohydrate was consisted of 75.7% (UH) and 96.7% (CH), and the low fraction was 72.7% (UL) and 87.1% (CL), respectively. The sugar of high and low molecular proteoglycan composed of glucose, mannose, fructose, galactose, xylose, ribose and arabinose. Glucose contents of all fraction were ranged from $46.9%{\sim}82.4%$ of the total sugar and the ratio of ${\alpha}$\;and\;{\beta}-glucose$ was $0.84{\sim}1.14$, and its indicated the proteoglycan to be ${\beta}-glucan$. Amino acids pattern showed that the fractions contained a large amount of aspartie acid, glutamic acid, alanine and leucine. These fractions showed the characteristics of IR absorption for ${\beta}-glucan$ at $890\;cm^{-1}\;and\;^{13}C-NMR$ spectroscopy showed the presence of the ${\beta}-1,3-glucan$ and a ${\beta}-1,6-glucan$.

  • PDF

Pyrolysis Characteristics of CCL(Copper Clad Laminate) Based Paper/Phenolic Resin Composites (종이/페놀수지가 주성분인 동박적층판(Copper Clad Laminate)의 열분해 특성)

  • Song, Jae-Hun;Kim, Seung-Do;Ahn, Hyun-Cheol;Kim, Gyung-Soo;Kim, Sang-Bum;Jung, Jae-Sung;Gong, Sung-Ho;Cho, Young-Gae
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.29 no.9
    • /
    • pp.1013-1019
    • /
    • 2007
  • Electronic wastes have increased tremendously. However, any reliable treatment methodologies have rarely been established. Electronic wastes have posed serious disposal problem due to their physico-chemical stability. This paper investigated the application possibility of pyrolysis for the purpose of recycling the p-CCL(phenol based Copper Clad Laminate). Thermogravimetric analysis(TGA) was used to investigate the thermal decomposition pattern of p-CCL. We elucidated the characteristics of pyrolysis by-products at operating temperatures of 280, 350 and $600^{\circ}C$. GC/MS and FT-IR were used to characterize the liquid by-products along with general characterization methods such as Ultimate Analysis, Proximate Analysis and Heating Value, whereas general characterization methods were only introduced for the solid by-products. At a heating rate of $5^{\circ}C$/min, TGA curves exhibited three decomposition stages: (1) low-temperature decomposition region$(<280^{\circ}C)$, (2) medium temperature region$(280\sim350^{\circ}C)$ and (3) high-temperature region$(>350^{\circ}C)$. The major compounds of liquid by-products at low- and medium-temperatures were accounted for by water and phenol, whereas branched phenols and furans were major compounds at high-temperatures. As the temperature increases, volatile quantities decreased but the fixed carbon increased. High heating values of solid by-products($7,400\sim7,600$ kcal/kg) would suggest that the solid by-products could be applicable as fuel. In addition, high fixed carbon but low ash content of the solid by-products offered an implication that they are capable of being upgradable for adsorbent after applying appropriate activating process.

Measurement of Rectal Rodiation dose in the Patients with Uterine Cervix fencer using In Vivo Dosimetry(Diode Detector) (자궁경부암 환자에서 In vivo dosimetry(Diode detector)를 이용할 직장선량의 측정)

  • Kim, Sung-Kee;Kim, Wan-Sun
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.16 no.1
    • /
    • pp.29-37
    • /
    • 2004
  • Purpose : A rectum and a bladder should be carefully considered in order to decrease side effects when HDR patient of uterine cervix cancer. Generally speaking, the value of dosimeter at a rectum and a bladder only depends on the value of a planning equipment, while some analyses of the value of dosimetry at rectum with TLD has been reported Or the contrary, it is hardly to find a report with in vivo dosimetry(diode detector). On this thesis, we would like to suggest the following. When a patient of uterine cervix cancer is in therapy, it is helpful to put a diode detector inside of a rectum in order to measure the rectal dose Based upon the result of the dosimetry, the result can be used as basic data at decreasing side effects. Materials and Methods : Six patients of uterine cervix cancer(four with tandem and ovoid, one with cylinder, and the other one with tandem and cylinder) who had been irradiated with HDR. Ir-192 totally 28 times from February 2003 to June 2003. We irradiated twice in the same distant spots with anterior film and lateral film whenever we measured with a diode detector. Then we did planning and compared each film. Results : The result of the measurement 4 patients with a diode detector is the following. The average and deviation from 3 patients with tandem and ovoid were $274.1{\pm}13.4cGy$, from 1 patient with tandem and ovoid were $126.1{\pm}7.2cGy$, from 1 patient with cylinder were $99.7{\pm}7.1cGy$, and from 1 patient with tandem and cylinder were $77.7{\pm}11.5cGy$. Conclusion : It is difficult to predict how the side effect of a rectum since the result of measurement with a diode detector depends on the state of a rectum. According to the result of the study, it is effective to use a TLD or an in vivo dosimetry and measure a rectum in order to consider the side effect. It is very necessary to decrease the amount of irradiation by controlling properly the duration of the irradiation and gauze packing, and by using shield equipments especially when side effects can be expected.

  • PDF

Preliminary Results of Concurrent Chemotherapy and Radiation Therapy using High-dose-rate Brachytherapy for Cervical Cancer (자궁경부암에 항암화학요법과 동시 병용요법으로 외부 방사선조사와 고선량률 강내조사의 예비적 치료 결과)

  • Lee, Kyung-Ja;Lee, Ji-Hye;Lee, Re-Na;Suh, Hyun-Suk
    • Radiation Oncology Journal
    • /
    • v.24 no.3
    • /
    • pp.171-178
    • /
    • 2006
  • [ $\underline{Purpose}$ ]: To determine the efficacy and safety of concurrent chemotherapy and radiation therapy with high-dose-rate brachytherapy for cervical cancer. $\underline{Materials\;and\;Methods}$: From January 2001 to December 2002, 30 patients with cervical cancer were treated with concurrent chemotherapy (cisplatin and 5-FU) and definitive radiation therapy. The median age was 58 (range $34{\sim}74$) year old. The pathology of the biopsy sections was squamous cell carcinoma in 29 patients and one was adenocarcinoma. The distribution to FIGO staging system was as follows: stage IB, 7 (23%); IIA, 3 (10%); IIB, 12 (40%); IIIA, 3 (10%); IIIB, 5 (17%). All patients received pelvic external beam irradiation (EBRT) to a total dose of $45{\sim}50.4\;Gy$ (median: 50.4 Gy) over $5{\sim}5.5$ weeks. Ir-192 HDR intracavitary brachytherapy (ICBT) was given after a total dose of 41.4 Gy. HDR-ICBT was performed twice a week, with a fraction point A dose of 4 Gy and median dose to point A was 28 Gy (range: $16{\sim}32\;Gy$) in 7 fractions. The median cumulative biologic effective dose (BED) at point A (EBRT+ICBT) was $88\;Gy_{10}$ (range: $77{\sim}94\;Gy_{10}$). The median cumulative BED at ICRU 38 reference point (EBRT+ICBT) was $131\;Gy_3$ (range: $122{\sim}140\;Gy_3$) at point A, $109\;Gy_3$ (range: $88{\sim}125\;Gy_3$) at the rectum and $111\;Gy_3$ (range: $91{\sim}123\;Gy_3$) at the urinary bladder. Cisplatin ($60\;mg/m^2$) and 5-FU ($1,000\;mg/m^2$) was administered intravenously at 3 weeks interval from the first day of radiation for median 5 (range: $2{\sim}6$) cycles. The assessment was performed at 1 month after completion of radiation therapy by clinical examination and CT scan. The median follow-up time was 36 months (range: $8{\sim}50$ months). $\underline{: The complete response rate after concurrent chemoradiation therapy was 93.3%. The 3-yr actuarial pelvic control rate was 87% and 3-yr actuarial overall survival and disease-free survival rate was 93% and 87%, respectively. The local failure rate was 13% and distant metastatic rate was 3.3%. The crude rate of minor hematologic complications (RTOG grade 1-2) occurred in 3 patients (10%) and one patient had suffered from severe leukopenia (RTOG grade 4) during concurrent treatment. Acute minor enterocolitis (RTOG grade 1-2) occurred in 11 patients (37%) and one patient (3%) was suffered from colon perforation during radiation therapy. Late colitis of RTOG grade 1 occurred in 5 patients (15%). Acute cystitis of RTOG grade 1 occurred in 12 patients (40%) and late cystitis of RTOG grade 2 occurred in one patient (3%). No treatment related death was seen. $\underline{Conclusion}$: The results of this study suggest that the concurrent chemoradiation therapy with HDR brachytherapy could be accepted as an effective and safe treatment for cervical cancer.

Magnetic Tunnel Junctions with AlN and AlO Barriers

  • Yoon, Tae-Sick;Yoshimura, Satoru;Tsunoda, Masakiyo;Takahashi, Migaku;Park, Bum-Chan;Lee, Young-Woo;Li, Ying;Kim, Chong-Oh
    • Journal of Magnetics
    • /
    • v.9 no.1
    • /
    • pp.17-22
    • /
    • 2004
  • We studied the magnetotransport properties of tunnel junctions with AlO and AlN barriers fabricated using microwave-excited plasma. The plasma nitridation process provided wider controllability than the plasma oxidization for the formation of MTJs with ultra-thin insulating layer, because of the slow nitriding rate of metal Al layers, comparing with the oxidizing rate of them. High tunnel magnetoresistance (TMR) ratios of 49 and 44% with respective resistance-area product $(R{\times}A) of 3 {\times} 10^4 and 6 {\times} 10^3 {\Omega}{\mu}m^2$ were obtained in the Co-Fe/Al-N/Co-Fe MTJs. We conclude that AlN is a hopeful barrier material to realize MTJs with high TMR ratio and low $R{\times}A$ for high performance MRAM cells. In addition, in order to clarify the annealing temperature dependence of TMR, the local transport properties were measured for Ta $50{\AA} /Cu 200 {\AA}/Ta 50 {\AA}/Ni_{76}Fe_{24} 20 {\AA}/Cu 50 {\AA}/Mn_{75}Ir_{25} 100 {\AA}/Co_{71}Fe_{29} 40 {\AA}/Al-O$ junction with $d_{Al}= 8 {\AA} and P_{O2}{\times}t_{0X}/ = 8.4 {\times} 10^4$ at various temperatures. The current histogram statistically calculated from the electrical current image was well in accord with the fitting result considering the Gaussian distribution and Fowler-Nordheim equation. After annealing at $340^{\circ}C$, where the TMR ratio of the corresponding MTJ had the maximum value of 44%, the average barrier height increased to 1.12 eV and its standard deviation decreased to 0.1 eV. The increase of TMR ratio after annealing could be well explained by the enhancement of the average barrier height and the reduction of its fluctuation.

Preparation of PEG-Folate-graft-Polyethylenimine as a Gene Carrier (유전자 전달체로서 폴리(에틸렌 글리콜) 및 폴레이트로 수식된 폴리(에틸렌 이민)의 합성)

  • Seo Dong Hoan;Kim Seon Hwa;Khang GilSon;Chi Sang Cheol;Shin Byung Cheol;Kim Moon Suk
    • Polymer(Korea)
    • /
    • v.29 no.2
    • /
    • pp.135-139
    • /
    • 2005
  • In this study, poly(ethylene imine) (PEI) modified by methoxypoly(ethylene glycol) (mPEG) and folate as a gene carrier was synthesized to decrease cytotoxicity and to improve in vivo targeting. mPEG was modified by glutaric anhydride (GA) to endow carboxylic end group, followed by the activation reaction with EDC (N-ethyl-N'-(3-dimethyl-aminopropyl) carbodiimide) and NHS (N-hydroxysuccinimide). The activated carboxylic end group of mPEG was reacted with the amines of PEI to give mPEG graft PEI. The mPEG-folate-graft-PEI was synthesized by the reaction of mPEG-PEI with folate pre-activated by EDC/NHS. The obtained copolymers were characterized by $^1H-NMR$ and FT-IR. Gel retardation assay and fluorescence measurement indicated that DNA formed the complexes with the synthesized copolymers above N/P charge ratio 2. The size of complexes was ranging from 100 nm to 300 m. In conclusion, we confirmed that the synthesized copolymer have the possibility as a DNA carrier.